• Title/Summary/Keyword: 지진성능평가

Search Result 729, Processing Time 0.031 seconds

Seismic Performance Evaluation of Unreinforced Masonry Buildings By Using a Three-Step Procedure (3단계 절차를 이용한 비보강 조적조 건물의 내진성능평가)

  • Kim, Tae-Wan;Min, Chan-Gi;Lee, Hui-Man
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.57-64
    • /
    • 2011
  • In this study, a seismic performance evaluation of unreinforced masonry buildings was conducted based on a revised draft of the outline of the seismic performance evaluation of existing buildings. The procedure of the performance evaluation is composed of three-steps, which are a preliminary evaluation, a first-level detailed evaluation, and a second-level detailed evaluation, where evaluation is conservatively conducted in the beginning and then more detailed evaluations are gradually conducted. For the study, ten two-story unreinforced masonry buildings were selected and evaluated using the three-step evaluation. The result showed that the performance levels between the preliminary and the first-level detailed evaluations were reversed, which is different from the intent of the procedure. Therefore, in the near future, the problems in each evaluation step that are presented in the results of this study need to be refined.

Probabilistic Safety Analysis for Seismic Performance Evaluation of Bridges -Focused on Fragility Analysis using Capacity Spectrum Method- (교량의 내진성능 평가를 위한 확률적 지진안전성 분석 - 역량스펙트럼법을 이용한 지진취약도 분석을 중심으로-)

  • 이진학;김상훈
    • Computational Structural Engineering
    • /
    • v.17 no.2
    • /
    • pp.31-41
    • /
    • 2004
  • 몇 일 전 필자는 대전에 위치한 한 연구소에 근무하고 계신 분으로부터 지진취약도 분석에 관한 문의 전화를 받았다. 그분의 대학 후배가 지진취약도에 대한 연구를 하고 싶다는 내용이었다. 최근 필자는 그분 외에도 다른 분들과 함께 지진취약도 분석 및 이를 확장한 바람에 의한, 혹은 홍수에 의한 구조물의 확률적 안전성 분석에 관한 논의를 하곤 하였다. 현재까지 국내에서는 구조물의 취약도 분석에 대한 연구가 그다지 활발하지 않으나, 이에 대한 관심은 지속적으로 증가할 것으로 보여진다. 지진취약도를 한마디로 요약하면, "임의의 크기를 갖는 지진이 발생하였을 때, 구조물에 어느 규모 이상의 손상이 발생할 확률"을 의미하는 것으로, 구조물의 확률적 지진안전성으로 부를 수 있다. 예를 들어, "최대지반가속도가 0.1g인 지진이 발생하였을 때, 해당 구조물에 보수를 요하는 수준 이상의 손상이 발생할 확률이 30%이다"와 같은 정보를 지진취약도 곡선으로부터 읽을 수 있다. (중략)

Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment (내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가)

  • Chung, Lan;Lee, Joung-Woo;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.721-728
    • /
    • 2006
  • Earthquakes are reported thai building structures have been colossal damaged, but before 1988 designed structures which were not applicate seismic design code have no seismic performance. Especially, for the apartment structures were indicated that it have no resist wall element of earthquake before 1988 designed structures. We have to evaluate for seismic performance this structures, therefore it will be retrofitted for seismic index sufficient structures. We performed seismic performance evaluation for model structures by MIDAS which is general structure analysis software. In this study, it was performed shaking table test to evaluate model structure which is reinforcement concrete and 5 floors for seismic performance index. We made specimens by similar's law and tested shaking table test. In the shaking table test it is not performed prototype model test because of space and equipment condition. So we had made scale-down model for 1/5 by similar's law. That's why it needs for the evaluation of performance. However, it is not possible to do an experiment of prototype owing to the shortage of space and the limit of an experimental instrument in the shaking table test. Then, modeling and reducing the part of prototype do the experiment. In this experiment a shaking table test is done and seismic performance of model structures is evaluated by using similitude laws for scale down specimen. As a result it is proved that non-seismic design structures need to retrofit since seismic performance shows life safe grade in 0.12g of an earthquake.

Earthquake Damage Assessment of Reinforced Concrete School Buildings in Korea (국내 철근콘크리트 학교건물의 지진피해율 분포에 관한 연구)

  • Jeon, Kyeong-Joo;Wi, Jeong-Du;Lee, Kang-Seok;Hwang, Ki-Tae;Yoon, Seok-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.117-118
    • /
    • 2010
  • In this study, seismic capacities of reinforced concrete school buildings in S, G and J provinces(korea) are evaluated based on the rapid-screening method proposed in the previous research(Ref.1). And also, slight, medium and severe earthquake damage ratios, estimated in terms of ground acceleration levels(0.1g~0.25g), are also assessed herein.

  • PDF

KALIMER 원자로구조물의 면진성능 및 내진여유도 평가

  • Yoo, Bong;Koo, Kyung-Hoe;Lee, Jae-Han
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.683-689
    • /
    • 1996
  • 본 논문의 목적은 현재 국내에서 개념설계중인 KALIMER(Korea Advanced LIquid MEtal Reactor) 원자로구조물에 대한 면진성능과 내진여유도를 평가하여 이들 성능을 향상시킬 수 있는 주요 설계변경 부위를 검토하는 것이다. 이를 위하여 ANSYS 범용 유한요소해석코드를 이용하여 원자로구조물에 대한 3차원 유한요소해석모델을 작성하고 이로부터 집중질량 스프링으로 이루어진 지진해석모델을 개발하여 지진해석을 수행하였다. KALIMER 원자로 구조물에 대한 내진평가결과 내진능력(Seismic Capability)은 0.35g로 나타났으며 이는 Reactor Vessel Liner, Separation Plate그리고 Support Barrel의 연결부위의 수직 강성을 증가시키는 설계변경을 통하여 크게 향상될 수 있는 것으로 나타났다.

  • PDF

Seismic Performance Evaluation of Base-Isolated Multi-Story Piping System (지진격리된 복층구조 파이핑 시스템의 내진성능평가)

  • Jeon, Jun-Tai;Ryu, Yong-Hee;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.311-313
    • /
    • 2016
  • 본 연구는 지진격리장치가 적용된 파이핑 시스템에서 빌딩과 같은 구조요소의 상호작용에 의한 동적 거동을 분석하고자 기존 복층구조 파이핑 시스템과 빌딩시스템에 triple friction pendulum이 적용된 격리장치를 적용 하였다. 파이핑 시스템의 시간이력해석에 의한 동적거동 평가를 위해 OpenSees를 이용하여 지진격리된 빌딩 및 파이핑시스템의 수치해석모델을 구축하였으며, 또한 파이핑시스템의 경우 ceiling system and supporting system 등과 같은 요소로 구분하여 유한요소모델을 구축하였다. 결과적으로 지진격리장치가 적용된 빌딩-파이핑 시스템의 경우 각층의 drift 및 변위가 일정한 반면 비 적용된 시스템의 경우 층 가속도에 의한 구조물의 변위가 빌딩층에 따라 상당히 증가함을 볼 수 있다.

  • PDF

Seismic Risk Assessment of Bridges Using Fragility Analysis (지진취약도분석을 통한 교량의 지진위험도 평가)

  • Yi, Jin-Hak;Youn, Jin-Yeong;Yun, Chung-Bang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.6 s.40
    • /
    • pp.31-43
    • /
    • 2004
  • Seismic risk assessment of bridge is presented using fragility curves which represent the probability of damage of a structure virsus the peak ground acceleration. In theseismic fragility analysis, the structural damage is defined using the rotational ductility at the base of the bridge pier, which is obtained through nonlinear dynamic analysis for various input earthquakes. For the assessment of seismic risk of bridge, peak ground accelerations are obatined for various return periods from the seismic hazard map of Korea, which enables to calculate the probability density function of peak ground acceleration. Combining the probability density function of peak ground acceleration and the seismic fragility analysis, seismic risk assessment is performed. In this study, seismic fragility analysis is developed as a function of not the surface motion which the bridge actually suffers, but the rock outcrop motion which the aseismic design code is defined on, so that further analysis for the seismic hazard assessment may become available. Besides, the effects of the friction pot bearings and the friction pendulum bearings on the seismic fragility and risk analysis are examined. Lastly, three regions in Korea are considered and compared in the seismic risk assessment.

Seismic Performance Evaluation of RC Structure Strengthened by Steel Grid Shear Wall using Nonlinear Static Analysis (비탄성 정적해석을 이용한 격자강판 전단벽 보강 RC구조물의 내진성능평가)

  • Park, Jung Woo;Lee, Jae Uk;Park, Jin Young;Lee, Young Hak;Kim, Heecheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.6
    • /
    • pp.455-462
    • /
    • 2013
  • The effects of earthquakes can be devastating especially to existing structures that are not based on earthquake resistant design. This study proposes a steel grid shear wall that can provide a sufficient lateral resistance and can be used as a seismic retrofit method. The pushover analysis was performed on RC structure with and without the proposed steel grid shear wall. Obtain the performance point that the target structure for seismic loads applied to evaluate the response and performance levels. The capacity spectrum at performance point is nearly elastic range, so satisfied the performance objectives(LS level). And response modification factor(R factor) were calculated from the pushover analysis. The R factor approach is currently implemented to reflect inelastic ductile behavior of the structures and to reduce elastic spectral demands from earthquakes to the design level. The R factor increases from 2.17 to 3.25 was higher than the design criteria. As a result, according to reinforcement by steel grid shear wall, strength, stiffness, and ductility of the low-rise RC structure has been appropriately improved.

Seismic Evaluation of the Existing RC Piers (기존 철근콘크리트 교각의 내진성평가)

  • 전귀현;이지훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.155-168
    • /
    • 1998
  • In this paper, the structural properties of the existing reinforced concrete(RC) piers are surveyed and the major factors influencing the member strength and deformation capacity are identified. Also a seismic evaluation procedure of RC piers is presented. The factors controlling the member strength are the applied axial load, the reinforcement ratio and yield strength of longitudinal rebar for flexural strength, and the transverse reinforcement for shear strength. Member deformation capacity largely depends on transverse reinforcement ratio and anchor detail, and splice location of longitudinal reinforcement. The above structural detail should be investigated for the detail seismic evaluation of RC piers. The most of existing RC piers have inadequate transverse reinforcement anchor details and the splices of longitudinal reinforcement in the pier bottom where plastic hinges are formed after yielding. Therefore the deformation capacity is not enough for the ductile flexural behavior of the RC piers. The presented evaluation procedure can be used for the rational decisions as to seismic retrofitting of the existing RC piers.

  • PDF

Assessment of the Seismic Capacity of Structure Using Pseudodynamic Test (유사동적 실험법을 이용한 구조물의 내진 성능 평가)

  • 김대곤;김대영;안재현;박칠림
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.49-57
    • /
    • 1997
  • It is necessary to conduct researches about seismic design and analysis to protect various structures from earthquakes which are one of the most destructive natural disaster to human civilization. To assess the seismic capacity of structure, not only analytical but also experimental researches are important. Currently, pseudodynamic test known as computer-actuator on-line test is one of the available test methods to assess seismic capacity of structure without using shaking table. In this paper seismic capacity of simple one-degree of freedom structure was estimated by pseudodynamic test. Good agreement between the experimental and analytical results was obtained. Better results would be obtained when more sophisticated measuring and controlling instruments are available.

  • PDF