• Title/Summary/Keyword: 지진성능평가

Search Result 729, Processing Time 0.027 seconds

Evaluation of Response Modification Factors for Steel Moment Frame Buildings Subjected to Seismic Loads (지진 하중을 받는 철골 모멘트 골조 빌딩에 대한 반응수정계수의 평가)

  • Lee, Kihak;Woo, Sungwoo
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.585-596
    • /
    • 2006
  • This study focuses on the seismic behavior of 3-, 9-, and 20-story steel moment resisting frame (MRF) structures designed in accordance with the 2000 International Building Code using different Response Modification factors (R factors), i.e., 8, 9, 10, 11, and 12. For a detailed case study, 30 different structures were evaluated for 20 ground motions representing the hazard level, which is equal to a 2% probability in 50 years (2% in 50 years). The results showed that the current R factors provide conservative designs for the 3- and 9-story buildings for the Collapse Prevention performance objective. the 20-story buildings, which were designed without using the minimum requirement of spectral acceleration CS prescribed in IBC 2000, did not satisfy the seismic performance for Collapse Prevention performance.

Feasibility Study of Seismic Probabilistic Risk Assessment for Multi-unit NPP with Seismic Failure Correlation (다수기의 확률론적 지진안전성 평가를 위한 지진손상 상관계수의 적용)

  • Eem, Seunghyun;Kwag, Shinyoung;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.319-325
    • /
    • 2021
  • The 2011 East Japan Earthquake caused accidents at a number of nuclear power plants in Fukushima, highlighting the need for a study on the seismic safety of multiple NPP (Nuclear Power Plant) units. In the case of nuclear power plants built on a site that shows a similar seismic response, there is at least a correlation between the seismic damage of structures, systems, and components (SSCs) of nuclear power plants. In this study, a probabilistic seismic safety assessment was performed for the loss of essential power events of twin units. To derive an appropriate seismic damage correlation coefficient, a probabilistic seismic response analysis was performed. Using the external event mensuration system program, we analyzed the seismic fragility and seismic risk by composing a failure tree of multiple loss of essential power events. Additionally, a comparative analysis was performed considering the seismic damage correlation between SSCs as completely independent and completely dependent.

Development of Isolators (Laminated Rubber Bearing) for the Seismic Isolation of LNG Storage Tanks (LNG 저장 탱크의 지진방지를 위한 면진베어링(LRB)의 개발)

  • 유춘화;김두훈;이동근;김남식;정우정
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.116-121
    • /
    • 1994
  • 지금까지 대형 구조물에 널리 사용되고 있는 Base Isolator는 특히, 지진하중에 대하여 상부 구조물의 지반분리(base isolation)을 이용한 지진제어를 목적으로 하기 때문에 Seismic Isolator라 한다. 일반적으로 면진베어링에는 LRB(Laminated Rubber Bearing) 방식과 R-FBI(resilient-friction base isolator) 방식으로 크게 나눌 수 있다. LRB 방식은 가장 널리 사용되는 면진베어링으로써 방진고무를 주된 재료로 하고 수직강성을 보강하기 위하여 steel plate를 조합하여 제작하며, 초기강성 및 에너지 소산능력을 증가시키기 위하여 단면중앙에 납(lead plug)를 삽입하기도 한다. R-FBI 방식은 방진고무 적층판 내부에 미끄럼판을 가지고 있으므로 LRB 방식에 비하여 더 큰 수평변위를 발생시킬 수 있다. 이번에 설계 제작한 면진베어링은 LNG 저장탱크의 Seismic Isolation을 목적으로 적용대상의 사양에 맞추어 설계 제작하고 성능평가 시험을 수행하여 LNG 저장탱크, 원자로, 대형 건축물등 지진으로부터 보호되어야 하는 대형구조물의 방진재로 적용할 수 있는가를 평가하고자 한다. 본 논문에서는 제작된 면진베어링의 설계를 검증하고 방진고무(HDR)재료의 물리적 특성시험, 축소모델에 의한 정적, 동적시험을 통하여 시험방법을 소개하고 이러한 시험결과를 기초로 하여 면진베어리의 성능을 평가하였으며, 면진베어링의 온도변화, 외부 수직하중의 변화등에 따른 특성변화와 LNG 저장탱크와 면진베어링의 체결방법에 따른 시험으로 체결방법을 검증하였으며, 대상물의 사양에 적합한가를 고찰하였다.

  • PDF

Dynamic Response of Seismically Isolated High-Story Buildings according to Earthquake Records (지진기록 사용에 따른 고층 면진건물의 동적 응답)

  • Lee, Hyun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.643-651
    • /
    • 2008
  • The purpose of this study is to evaluate seismic capacity of seismically isolated building according to the earthquake motion record selection method. To analyze the seismic behavior, 20-story building is designed, which has base isolation system. The using earthquake motion record were selected by two categories. The one is a proposed earthquake record according to soil type and response spectrum shape, and the other is a well known earthquake events such as El Centro (1940). The time history analysis results of base isolation buildings be induced difference results according to each ground motion records. Therefore detailed guidelines for the ground motion records selection method must be prepared. And the response of isolation story displacement and shear force show good seismic performance in consideration of the proposed earthquake records.

Seismic Response Analysis and Performance Evaluation of Wind-Designed Concentrically Braced Steel Highrise Buildings under Moderate Seismicity (중진대의 지진환경하에서 내풍설계된 초고층 철골조 중심가새골조의 지진응답해석 및 내진성능평가)

  • Lee, Cheol-Ho;Kim, Seon-Woong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.33-42
    • /
    • 2005
  • Even in moderate to low seismic regions like Korean peninsular where wind loading usually governs the structural design of a tall builidng, the probable structural impact of the 500-year design basis earthquake (DBE) or the 2400-year maximum credible earthquake (MCE) on the selected structural system should be considered at least in finalizing the design. In this study, seismic performance evaluation was conducted for concentrically braced steel highrise buildings that were only designed for wind by following the assumed domestic design practice. It was found that wind-designed concentrically braced steel highrise buildings possess significantly increased elastic seimsic capacity due to the system overstrength resulting from the wind-serviceability criterion and the width-to-thickness ratio limits on steel members. The strength demand-to-strength capacity study based on the response spectrum analysis revealed that, due to the system overstrength factors mentioned above, wind-designed concentrically braced steel highrise buildings having a slenderness ratio of larger than six can withstand elastically even the maximum credible earthquake at the performance level of immediate occupancy.

Evaluation of Seismic Performance for Building Structures by Hysteresis Model of Elements (부재의 이력모델에 따른 건축구조물의 내진성능 평가)

  • Han, Duck-Jeon;Ko, Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.4
    • /
    • pp.73-80
    • /
    • 2009
  • It is very important that predict the inelastic seismic behavior exactly for seismic performance evaluation of a building in the performance based seismic design. But, it is difficulty that predict the building behavior of actual and exact in simplified load-deformation relation of structural material and members. In this study, system ductility and story ductility capacity of building structure used to the Backbone hinge Model are estimated and compared considering the characteristics of load-deformation relation of structural material and members. Analyses results, bilinear hinge model has lower system ductility and story ductility demands than those of backbone hinge model.

  • PDF

Hybrid Control Strategies for Seismic Protection of Benchmark Cable-Stayed Bridges (지진하중을 받는 벤치마크 사장교를 위한 복합제어 기법)

  • Park, Kyu-Sik;Jung, Hyung-Jo;Lee, Chong-Heon;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.435-442
    • /
    • 2002
  • 본 연구에서는 사장교의 제어기법 개발을 위한 구조물로 제공되는 벤치마크(benchmark) 사장교에 대해 복합제어 기법을 적용하였다. 이 벤치마크 문제에서는 2003년 완공 예정으로 미국 Missouri 주에 건설 중인 Cape Girardeau 교를 대상 구조물로 고려하였다. Cape Girardeau 교는 New Madrid 지진구역에 위치하고, Mississippi 강을 횡단하는 주요 교량이라는 점 때문에 설계단계에서부터 내진 문제에 대하여 자세하게 고려되었다. 상세 설계도면을 기반으로 하여 교량의 전체적인 거동 특성을 정확하게 나타낼 수 있는 3차원 모델이 만들어졌고, 사장교의 제어 성능에 관련된 평가 기준이 수립되었다. 본 연구에서 사용한 복합제어 기법이란 지진하중으로 인해 구조물에 발생되는 하중을 줄이기 위한 수동제어 기법과 상판변위와 같은 구조물의 응답을 추가적으로 제어하기 위한 능동제어 기법이 결합된 제어방법이다. 수동제어 장치로는 현재 일반적으로 많이 사용되고 있는 납고무받침(lead rubber bearing)을 사용하였다. 능동제어 방법에는 $H_2$/LQG 제어 알고리듬(algorithm)을 사용하였다. 수치해석 결과 제안방법의 성능은 수동제어 방법에 비해 매우 효과적이며, 능동제어 방법에 비해서는 좀더 좋은 제어성능을 나타내었다. 또한, 복합제어 방법은 수동제어 부분 때문에 능동제어 방법에 비해 좀더 신뢰할 수 있는 제어 방법이다. 따라서 제안된 제어방법은 지진하중을 받는 사장교의 제어를 위해 효과적으로 사용될 수 있다.

  • PDF

Development of System-level Seismic Fragility Methodology for Probabilistic Seismic Performance Evaluation of Steel Composite Box Girder Bridges (강상자형 합성거더교의 확률론적 내진성능 평가를 위한 시스템-수준 지진취약도 방법의 개발)

  • Sina Kong;Yeeun Kim;Jiho Moon;Jong-Keol Song
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.3
    • /
    • pp.173-184
    • /
    • 2023
  • Presently, the general seismic fragility evaluation method for a bridge system composed of member elements with different nonlinear behaviors against strong earthquakes has been to evaluate at the element-level. This study aims to develop a system-level seismic fragility evaluation method that represents a structural system. Because the seismic behavior of bridges is generally divided into transverse and longitudinal directions, this study evaluated the system-level seismic fragility in both directions separately. The element-level seismic fragility evaluation in the longitudinal direction was performed for piers, bridge bearings, pounding, abutments, and unseating. Because pounding, abutment, and unseating do not affect the transverse directional damages, the element-level seismic fragility evaluation was limited to piers and bridge bearings. Seismic analysis using nonlinear models of various structural members was performed using the OpenSEES program. System-level seismic fragility was evaluated assuming that damage between element-levels was serially connected. Pier damage was identified to have a dominant effect on system-level seismic fragility than other element-level damages. In other words, the most vulnerable element-level seismic fragility has the most dominant effect on the system-level seismic fragility.

Study on 2-D Seismic Evaluation of Asymmetric Buildings Using Capacity Spectrum Method (능력스펙트럼법을 이용한 비정형 건축구조물의 2차원 지진성능평가 방법 연구)

  • 김상호;이한선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.296-303
    • /
    • 2001
  • In the evaluation of asymmetric buildings, torsional effects should be considered by three-dimensional analysis. However, this analysis is time-consuming and requires great efforts. The goal of this study is to give a comprehensible and simple procedure in the seismic evaluation by using two-dimensional analysis of asymmetric buildings so that practicing engineers can easily adapt it to their work.

  • PDF

Fragility Curve Evaluation of Reinforced Concrete Shear Wall Structures according to Various Nonlinear Seismic Analysis Methods (다양한 비선형지진해석방법에 따른 철근콘크리트 전단벽 구조물의 취약도곡선 평가)

  • Jang, Dong-Hui;Song, Jong-Keol;Kang, Sung-Lib;Park, Chang-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.1-12
    • /
    • 2011
  • Seismic fragility analysis has been developed to evaluate the seismic performance of existing nuclear power plants, but now its applicability has been extended to buildings and bridges. In general, the seismic fragility curves are evaluated from the nonlinear time-history analysis (THA) using many earthquake ground motions. Seismic fragility analysis using the nonlinear THA requires a time consuming process of structural modeling and analysis. To overcome this shortcoming of the nonlinear THA, simplified methods such as the displacement coefficient method (DCM) and the capacity spectrum method (CSM) are used for the seismic fragility analysis. In order to evaluate the accuracy of the seismic fragility curve calculated by the DCM and the CSM, the seismic fragility curves of a reinforced concrete shear wall structure calculated by the DCM and CSM are compared with those calculated by the nonlinear THA. In order to construct a numerical fragility curve, 190 artificially generated ground motions corresponding to the design spectrum and the methodology proposed by Shinozuka et al. are used.