• Title/Summary/Keyword: 지지부 개선방법

Search Result 30, Processing Time 0.028 seconds

A Study on the Support Toning Method of High-Speed Chip-Mounter (고속 표면실장기의 지지부 개선 방법에 관한 연구)

  • Oh, Chang-Kyun;Park, Heung-Keun;Park, Jin-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.597-602
    • /
    • 2006
  • In this paper, a proper support tuning method is established by identifying the dynamic characteristics of the machine, the floor. and the inertia force. Also, the limitation of a passive isolation is presented. To simplify the dynamic analysis and to establish a proper design method for supporting system, each of the machine and the floor is modeled as a single degree of freedom spring-mass-damper system under careful investigation of the dynamic characteristics of each system and appropriate assumptions. Then, the dynamic behavior of a 2DOF system and the effect of the mass and the damping are investigated. Also, the characteristics of motion profiles are investigated. In addition, a quasi-static analysis on the transmitted force through support is performed and related tests are performed.

  • PDF

Evaluation of Field Applicability of Helical Pile Using Hexagon Joints (육각형 이음부를 이용한 회전관입말뚝의 현장적용성 평가)

  • Jeong, Sangguk
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.635-648
    • /
    • 2020
  • Performance improvement of helical piles in static load tests using hexagon joints that do not require welding or bolting was investigated. Two sites were selected for pile field tests to evaluate their bearing capacity. Static and pull-out load tests were undertaken to assess the method for estimating bearing capacity. The field tests indicated that the bearing capacity of the gravity grout pile was ≥600 kN in the static load test, consistent with the AC 358 Code. The non-grout pile had a bearing capacity of ≤600 kN, suggesting that gravity grouting is required. Field pile load-test results were used to establish the bearing capacity equation, based on a small number of helical pile.

Development of Vision system for Back Light Unit of Defect (백라이트 유닛의 결함 검사를 위한 비전 시스템 개발)

  • Cho, Sang-Hee;Han, Chang-Ho;Oh, Choon-Suk;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.127-129
    • /
    • 2005
  • 본 연구에서는 백라이트 유닛의 검사를 위한 머신비전 시스템을 구축한다. 시스템은 크게 하드웨어와 소프트웨어로 나눌 수 있고 하드웨어는 조명부, 영상획득부, 로봇 암 제어부로 분류된다. 조명부는 36W FPL램프로 구성되었고 조명부의 상판에 아크릴판을 거치대로 이용하여 백라이트 유닛을 거치한다. 로봇 암 제어부는 2축 로봇 암을 제어하여 로봇 암의 센서부착 지지대에 부착된 CCD 센서를 이동시킨다. 이와 동시에 영상획득부에서는 이미지를 획득하여 PC로 전송한다. 소프트웨어의 화상처리 검사 알고리즘은 일정 패턴이 있는 도광판에 대한 검사 알고리즘과 일정패턴이 없근 백라이트 유닛에 대한 검사 알고리즘으로 분리된다. 일정 패턴이 인쇄되어 있는 패널에 대한 검사 알고리즘은 모폴로지 연산을 이용하는 템플릿 체크방법과 블록 매칭 방법이 사용되었고 일정패턴이 없는 유닛에 대한 검사는 개선된 Otsu 방법을 이용하여 얼룩이나 흐릿한 결함에 대한 결함을 검출하였다. 실험결과 불균일한 결함과 밝기가 일정하지 않은 결함일지라고 90% 이상의 검출율로 뛰어난 성능을 입증하였다.

  • PDF

Assessment of Tracking Retardant Aluminium Stranded Conductor Aluminium Cald Steel Reinforced Outdoor Cable (ACSR/AW-TR/OC) (트래킹억제형 알루미늄피복강심 알루미늄 절연전선 평가기술)

  • Soh, Jin-Joong;Shim, Dae-Sub;Kim, Kyu-Sub;Yoon, Ki-Teak
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.227-228
    • /
    • 2005
  • 사용중인 OC의 사고가 외물접촉, 자연현상, 일반인 과실 등으로 인하여 전체 배전선로 일시고장의 대부분을 차지하고 있음으로, 피복의 트래킹 성능을 개선하여 수목 및 조류와의 접촉으로 인한 접촉부 전개 집중 시 또는 지지금구의 바인더부에 고전계 인가 시 트래킹에 의한 절연물의 탄화, 침식 등에 의하여 발생할 수 있는 절연파괴 등의 사고 위험을 줄이기 위하여 개발된 제품으로 산악지역 등에서 내트래킹, 내부식성, 수밀성 및 전기적인 특성이 우수하다. 본 평가기술에서는 알루미늄 묘|복강선, 연선 및 절연체의 일반적인 특성과 트래킹성, 도체수밀, 내후성, 밀착도, 교류파괴전압 등의 주요한 평가시험에 대한 방법을 검토하여 평가시험에 적용하여 평가시험시 문제점을 도출하고 평가시험방법을 정립하고자 한다.

  • PDF

Multidisciplinary approach of the problem of unaesthetic implants in the maxillary anterior dentition (비심미적 임플란트의 심미성 회복을 위한 다각적 접근법)

  • Joo, Ji-Young;Choi, Jeomil;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • Periodontal tissue destroyed by inflammation is difficult to achieve regeneration of the tissue and esthetic restorations only by surgical methods. In particular, improvement of esthetics is more difficult if the problem is related to the implant. A 23 year old woman suffered from unesthetic anterior implant prosthesis. According to her dental history, a repeated bone graft and soft tissue graft failed at a local dental clinic. It was needed to resolve the inflammation and to improve the esthetics. A free gingival graft and ridge augmentation accompanied by guided bone regeneration and a vascularized interpositional periosteal connective tissue graft was performed. Instead of implant prosthesis, a conventional fixed bridge was adopted for better esthetic result. The patient was satisfied with the esthetic conventional fixed prosthesis. This case report introduces esthetic rehabilitation of unesthetic implant prosthetics in the maxillary anterior dentition by a combination of surgical and prosthetic approaches.

Analytical Study on the Appropriateness of Design Formula and Possibility of Improving Bearing Capacity of Bored Pile (매입말뚝의 설계식 적정성 및 지지력 상향 가능성 분석 연구)

  • Park, Jong-Bae;Lee, Bum-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.6 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • To improve the pile design efficiency(design bearing capacity/the strength of materials) from 70 percent(160tonf) to 80 percent(190tonf), this paper analysed the existing pile loading test data and performed the precise dynamic loading test and Bi-directional loading test for the first time in Korea. Analysis result of the existing dynamic loading test data by Davisson method showed that bearing capacity of piles penetrated at weathered rock stratum(N=50/15) exceeded 190tonf. But the analysis result by CAPWAP method showed that piles less than the target bearing capacity were 40% due to the lack of impact energy. To get the target bearing capacity from the dynamic loading test, using the hammer over 6tonf to trigger the enough impact energy is necessary. Allowable bearing capacty of Bi-directional static loading test by Davisson method was 260.0~335tonf(ave. 285.3tonf) and exceeded overwhelmingly the target capacity. And this exceeded the bearing capacity of precise dynamic loading test(ave. 202.3tonf) performed on the same piles over 40%. The difference between the capacity of Bi-directional loading test and dynamic loading test was caused by the insufficient impact energy during dynamic loading test and increase by interlocking effect by near piles during Bi-directional static loading test.

A Study on Improvement of Structural Strength Evaluation Methods for Tank of Tank Car used for Carrying Hazard Materials (위험물 수송 철도차량 탱크의 구조강도 평가방법 개선연구)

  • Lim, Chung-Hwan;Goo, Byung-Choon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.239-245
    • /
    • 2008
  • In this study, we researched about characteristics of many kinds of tank cars for carrying hazard materials and performed structural strength evaluation using finite element analysis for tank of asphalt tank car to suggest the efficient analysis method that can develop accuracy regarding to characteristics of tank cars. For this, we analyzed the asphalt tank refer to JIS E 7102 (Design Method for Tanks of Tank Cars). As results, we could show that the maximum stress is applied at the area supported by saddle and the maximum stress is under a criterion suggested from JIS E 7102. Therefore we verified that this asphalt tank car had enough structural strength.

Direct Punching Shear Strength Model for Interior Slab-Column Connections and Column Footings with Shear Reinforcement (전단 보강 슬래브-기둥 내부 접합부 및 기초판에 대한 뚫림 전단강도 모델)

  • Choi, Kyoung-Kyu;Kim, Sug-Hwan;Kim, Dong-Hoon;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.159-168
    • /
    • 2011
  • In the present study, an improved design method was developed for the punching shear strength of interior slabcolumn connections and column footings with and without shear reinforcement. In the evaluation of the punching shear strength, the possible failure mechanisms of the connections and column footings were considered. The considered failures modes were inclined tensile cracking of concrete, yielding of shear re-bars, and concrete crushing of compression zone/strut. The punching shear applied to the concrete critical section was assumed to be resisted mainly by the compression zone. The punching shear strength of the concrete compression zone was evaluated based on the material failure criteria of the concrete subjected to the compressive normal stress and shear stress. For verification of the proposed design method, its prediction was compared with the existing test results. The result showed that the proposed method predicted the strengths of the test specimens better than the current design methods of the KCI code for both the shear reinforced and unreinforced cases.

The Successful Application of Nuss Procedures with Modified Operative Technique (수술적 기법의 보완을 통한 성공적인 너스 술식의 적용(단일 기관 135명의 경험))

  • Kim Do-Mun;Shim Young-Mog;Kim Kwhan-Mien;Choi Yong-Soo;Kim Jhin-Gook
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.765-769
    • /
    • 2006
  • Background: Nuss procedure is a minimally invasive technique for correcting the pectus excavatum. But there are some limitations of correcting the complex anomaly or grown-up patients. Material and Method: we retrospectively reviewed 135 consecutive patients who underwent repair of pectus excavatum by the Nuss procedure and its modifications between November 1999 and December 2004. We analyzed the computed tomography, age on operation, operative technique, and complications. Result: We operated 135 patients of pectus excavatum during 62 months. Total number of operations about Nuss procedure is 216, including bar removal procedure of 64 cases, redo Nuss procedures of 47 cases. We modified the point of bar insertion to the hinge point, made a shoulder in the bar to prevent a displacement. And then we changed the fixation material from Vicryl to steel wire. If the patients are old, we retract the sternum during bar rotation and fixation. Until 2002, the number of redo Nuss operations were 17, complications were 23. but, after modifications, the number of redo Nuss operation were 0, complications were 2. Conclusion: This result indicates that our modifications of Nuss operation is effective, and could decrease the number of redo Nuss operation and complications.

Reliability Estimation of Static Design Methods for Driven Steel Pipe Piles in Korea (국내 항타강관말뚝 설계법의 신뢰성평가)

  • Huh, Jung-Won;Park, Jae-Hyun;Kim, Kyung-Jun;Lee, Ju-Hyung;Kwak, Ki-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.12
    • /
    • pp.61-73
    • /
    • 2007
  • As a part of Load and Resistance Factor Design(LRFD) code development in Korea, in this paper an intensive reliability analysis was performed to evaluate reliability levels of the two static bearing capacity methods for driven steel pipe piles adopted in Korean Standards for Structure Foundations by the representative reliability methods of First Order Reliability Method(FORM) and Monte Carlo Simulation(MCS). The resistance bias factors for the two static design methods were evaluated by comparing the representative measured bearing capacities with the design values. In determination of the representative bearing capacities of driven steel pipe piles, the 58 data sets of static load tests and soil property tests were collected and analyzed. The static bearing capacity formula and the Meyerhof method using N values were applied to the calculation of the expected design bearing capacity of the piles. The two representative reliability methods(FORM, MCS) based computer programs were developed to facilitate the reliability analysis in this study. Mean Value First Order Second Moment(MVFOSM) approach that provides a simple closed-form solution and two advanced methods of FORM and MCS were used to conduct the intensive reliability analysis using the resistance bias factor statistics obtained, and the results were then compared. In addition, a parametric study was conducted to identify the sensibility and the influence of the random variables on the reliability analysis under consideration.