• Title/Summary/Keyword: 지중파이프

Search Result 52, Processing Time 0.021 seconds

Thermal-Hydraulic Analysis of Pipeline Transport System for Marine Geological Storage of Carbon Dioxide (이산화탄소 해양지중저장 처리를 위한 파이프라인 수송시스템의 열-유동 해석)

  • Huh, Cheol;Kang, Seong-Gil;Hong, Sup;Choi, Jong-Su;Baek, Jong-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.88-94
    • /
    • 2008
  • The concentration of atmospheric carbon dioxide (CO2), which is one of the major greenhouse gases, continues to rise with the increase in fossil fuel consumption. In order to mitigate global warming the amount of CO2 discharge to the atmosphere must be reduced. Carbon dioxide capture and storage (CCS) technology is now regarded as one of the most promising options. To complete the carbon cycle in a CCS system, a huge amount of captured CO2 from major point sources such as power plantsshould be transported for storage into the marine or ground geological structures. Since 2005, we have developed technologies for marine geological storage of CO2,including possible storage site surveys and basic design of CO2 transport and storage process. In this paper, the design parameters which will be useful to construct on-shore and off-shore CO2 transport systems are deduced and analyzed. To carry out this parametric study, we suggested variations in thedesign parameters such as flow rate, diameter, temperature and pressure, based on a hypothetical scenario. We also studied the fluid flow behavior and thermal characteristics in a pipeline transport system.

Process Design of Carbon Dioxide Storage in the Marine Geological Structure: II. Effect of Thermodynamic Equations of State on Compression and Transport Process (이산화탄소 해양지중저장 처리를 위한 공정 설계: II. 열역학 상태방정식이 압축 및 수송 공정에 미치는 영향 평가)

  • Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.4
    • /
    • pp.191-198
    • /
    • 2008
  • To design a reliable $CO_2$ marine geological storage system, it is necessary to perform numerical process simulation using thermodynamic equation of state. $CO_2$ capture process from the major point sources such as power plants, transport process from the capture sites to storage sites and storage process to inject $CO_2$ into the deep marine geological structure can be simulate with numerical modeling. The purpose of this paper is to compare and analyse the relevant equations of state including ideal, BWRS, PR, PRBM and SRK equation of state. We also studied the effect of thermodynamic equation of state in designing the compression and transport process. As a results of comparison of numerical calculations, all relevant equation of state excluding ideal equation of state showed similar compression behavior in pure $CO_2$. On the other hand, calculation results of BWRS, PR and PRBM showed totally different behavior in compression and transport process of captured $CO_2$ mixture from the oxy-fuel combustion coal-fired plants. It is recommended to use PR or PRBM in designing of compression and transport process of $CO_2$ mixture containing NO, Ar and $O_2$.

  • PDF

Effect of Root Zone Warming by Hot Water on Rhizosphere Environment and Growth of Greenhouse- grown Oriental Melon (Cucumis melo L.) (온수 지중가온이 참외의 근권환경 및 생육에 미치는 영향)

  • 신용습;이우승;도한우;배수곤;최성국
    • Journal of Bio-Environment Control
    • /
    • v.6 no.2
    • /
    • pp.103-109
    • /
    • 1997
  • This experiment was conducted to investigate the effects of root zone warming on rhizosphere temperature of Oriental melon (Cucumis melo L. var. Makuwa) in winter season. Root zone was warmed by hot water flowing through pipe set at 35cm depth from the ridge. Treatments of minimum soil temperature at 20cm depth were 17, 21, $25^{\circ}C$, and non-warmed from Jan. 18 to Apr. 18. The results are summarized as follows. 1. The cumulative soil temperature for 1 month after planting oriental melon was 441, 558, 648, and 735$^{\circ}C$ at control, 17, 21, and $25^{\circ}C$ plot, respectively. 2. As soil temperature was higher, air temperature in tunnel was higher. The lowest temperature in control plot at night was 9.5$^{\circ}C$, 11.$0^{\circ}C$ in 17$^{\circ}C$ plot, 13.5$^{\circ}C$ in 21$^{\circ}C$ plot, and 16.5$^{\circ}C$ in $25^{\circ}C$ plot, respectively. 3. The xylem exudate amount of control plot for 24 hours just after basal stem abscission was 8.1$m\ell$. It was 1.2 times higher in 17$^{\circ}C$ plot, 1.3 times higher in 21 $^{\circ}C$ plot, and 4.8 times higher in $25^{\circ}C$ plot than in control plot at 30 days after planting. The xylem exudate amount at 67 days after planting of control plot was 10.4$m\ell$, those of 17, 21, $25^{\circ}C$ plots were 1.1, 3.2, and 3.3 times as compared to control plot. 4, Early growth in leaf length, stem diameter, leaf number and leaf area for 30 days after planting were better in higher temperature plots than in control plot. Particularly, the increase of leaf area was striking in higher temperature plots. Leaf area of control plot was 279.5$\textrm{cm}^2$ for 30 days after planting, 153.4% in 17$^{\circ}C$ plot, 745.6% in 21$^{\circ}C$ plot and 879.4% in $25^{\circ}C$ plot were increased as compared to in control plot.

  • PDF

Experimental Study on Generating mechanism of The Ground Subsidence of Due to Damaged Waters supply Pipe (상수관로 파손으로 인한 지반함몰 발생메카니즘에 관한 실험적 연구)

  • Kim, Youngho;Kim, Joo-Bong;Kim, Dowon;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.139-148
    • /
    • 2017
  • Ground subsidence caused by damaged water pipe and sewer is recently increasing due to the aging of city and pipeline in many city. Although many recent studies have verified characteristics of ground subsidence due to wastewater pipe breakdown, research about characteristics of ground subsidence due to water pipe is insignificant. subsidence due to water pipe is insignificant. This study aims to identify the ground failure mechanism caused by water and sewer pipe breakdown. Accordingly, we conducted an indoor model experiment to verify characteristics of ground subsidence considering characteristics of ground and ground failure. The water pipe pressure and velocity head was considered to find out ground subsidence mechanism. Also comparative analysis is conducted by analyzing relative density and fine-grain content considering embedded condition of water pipe. When the relative density and seepage pressure is low, small scale ground subsidence can occur, but when the conditions are opposite, ground subsidence occur in large scale and expands to ground level over time. Furthermore, it is acknowledgeable that ground cavity that is formed after soil run off due to seepage in deep earth, maintains steady strength and stays on the ground level for long period.

Effect of Root Zone Warming by Hot Water on Fruit Characteristics and Yield of Greenhouse- Grown Oriental Melon (Cucumis melo L.) (온수 지중가온이 참외의 과실특성 및 수량에 미치는 영향)

  • 신용습;이우승;연일권;최성국;최부술
    • Journal of Bio-Environment Control
    • /
    • v.6 no.2
    • /
    • pp.110-116
    • /
    • 1997
  • This experiment was conducted to investigate the effects of root zone warming on fruit yield of oriental melon (Cucumis melo L. var. Makuwa) in winter season. Root zone was warmed by hot water flowing through pipe set at 35cm depth from the ridge. Treatments of minimum soil temperature at 20cm depth were 17, 21, $25^{\circ}C$ and non-warming from Jan. 18 to Apr. 18. The results are summarized as follows. 1. The blooming of female flower was faster 1 days in 17$^{\circ}C$ plot, 6 days in 21$^{\circ}C$ plot, and 7 days in $25^{\circ}C$ plot than in control plot and the days from blooming to harvesting were shorter 5 days in 17$^{\circ}C$ plot, 11 days in 21$^{\circ}C$ plot, and 12 days in $25^{\circ}C$ plot than in control plot. 2. Mean fruit weight was the highest in 21$^{\circ}C$ plot, followed $25^{\circ}C$, 17$^{\circ}C$ and control plots, respectively, and flesh thickness was the highest in $25^{\circ}C$ plot, followed by 21, 17$^{\circ}C$ and control plots, respectively. 3. Early and middle-phase yield was the highest in $25^{\circ}C$ plot, followed by 21$^{\circ}C$, 17$^{\circ}C$ and control plots but late yield was the highest in 17$^{\circ}C$ plot, followed by control, 21, and $25^{\circ}C$ plots. Total yield per 10a was higher 33% in 17$^{\circ}C$ plot, 49% in 21$^{\circ}C$ plot, and 37a in $25^{\circ}C$ plots than in control plot, harvested 1, 490kg per 10a. 4. Total yield was highest in 21$^{\circ}C$ plot, followed by $25^{\circ}C$, 17$^{\circ}C$, and control plots. Malformed and fermented fruit rates were the highest in control, followed by 17, 25, and 21$^{\circ}C$ plots and marketable fruit rate was 21, 25, 17$^{\circ}C$, and control plot in order.

  • PDF

Evaluation on in-situ Heat Exchange Efficiency of Energy Slab According to Pipe Materials and Configurations (파이프 재질 및 형태에 따른 에너지 슬래브의 현장 열교환 성능 평가)

  • Lee, Seokjae;Oh, Kwanggeun;Han, Shin-in;Park, Sangwoo;Choi, Hangseok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2017
  • The energy slab is a ground coupled heat exchanger equipped in building slab structures, which represents a layout similar to the horizontal ground heat exchanger (GHEX). The energy slab is installed as one component of the floor slab layers in order to utilize the underground structure as a hybrid energy structure. However, as the energy slab is horizontally arranged, its thermal performance is inevitably less than the conventional vertical GHEXs. Therefore, stainless steel (STS) pipes are alternatively considered as a heat exchanger instead of high density polyethylene (HDPE) pipes in order to enhance thermal performance of GHEXs. Moreover, not only a floor slab but also a wall slab can be utilized as a heat-exchangeable energy slab in order to maximize the use of underground space effectively. In this paper, four field-scale energy slabs were constructed in a test bed, which consist of the STS and HDPE pipe, and a series of thermal response tests (TRTs) was conducted to evaluate relative heat exchange efficiency per unit pipe length according to the pipe material and the configuration of energy slabs. The energy slab equipped with the STS pipe shows higher thermal performance than the energy slab with the HDPE pipe. In addition, thermal performance of the wall-type energy slab is almost equivalent to the floor-type energy slab.

A Study on the Simulation of Underground Acoustic Telemetry (지중 원격 음파통신 시뮬레이션 연구)

  • Shin, Younggy
    • Plant Journal
    • /
    • v.18 no.2
    • /
    • pp.41-45
    • /
    • 2022
  • The conventional communication method using mud flow pressure waves has a speed of 1-2 bps, so it takes a long time to communicate, making real-time control impossible. Although the sound wave communication method for improving the communication speed by 10 times or more has been commercialized, its use is limited due to its high price and there are not many application cases. In this study, the simulator corresponding to the facility was developed to develop performance similar to the actual test results. For simulating sound wave communication through a drill pipe, we proposed a governing equation that can simulate friction damping by mud and developed a numerical analysis model. The attenuation factor was corrected by comparing it with the attenuation rate of sound wave energy at the drilling site. The developed numerical analysis model was applied to the QPSK modulation type communication algorithm to confirm the excellent performance of the communication error rate of 0.04% in the ground. This is the communication performance under the condition that noise has not been mixed yet, and in order to apply it, the technology of reproducing the actual noise signal for mixing by securing the field noise data was established.

  • PDF

Effect of Nitrogen Impurity on Process Design of $CO_2$ Marine Geological Storage: Evaluation of Equation of State and Optimization of Binary Parameter (질소 불순물이 이산화탄소 해양 지중저장 공정설계에 미치는 영향 평가: 상태방정식의 비교 분석 및 이성분 매개변수 최적화)

  • Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.3
    • /
    • pp.217-226
    • /
    • 2009
  • Marine geological storage of $CO_2$ is regarded as one of the most promising options to response climate change. Marine geological storage of $CO_2$ is to capture $CO_2$ from major point sources, to transport to the storage sites and to store $CO_2$ into the marine geological structure such as deep sea saline aquifer. Up to now, process design for this $CO_2$ marine geological storage has been carried out mainly on pure $CO_2$. Unfortunately the captured $CO_2$ mixture contains many impurities such as $N_2$, $O_2$, Ar, $H_2O$, $SO_x$, $H_2S$. A small amount of impurities can change the thermodynamic properties and then significantly affect the compression, purification and transport processes. In order to design a reliable $CO_2$ marine geological storage system, it is necessary to perform numerical process simulation using thermodynamic equation of state. The purpose of the present paper is to compare and analyse the relevant equations of state including PR, PRBM, RKS and SRK equation of state for $CO_2-N_2$ mixture. To evaluate the predictive accuracy of the equation of the state, we compared numerical calculation results with reference experimental data. In addition, optimum binary parameter to consider the interaction of $CO_2$ and $N_2$ molecules was suggested based on the mean absolute percent error. In conclusion, we suggest the most reliable equation of state and relevant binary parameter in designing the $CO_2-N_2$ mixture marine geological storage process.

  • PDF

Growth and Berry Quality of 'Kyoho' Grapes in Double Cropping System as Affected by Root Zone Heating and CO2 Enrichment in Plastic Greenhouse ('거봉' 포도 2기작 재배 시 근권 가온 및 CO2 시용이 생장 및 과실 품질에 미치는 영향)

  • Oh, Sung Do;Kim, Yong Hyeon;Choi, Dong Geun
    • Horticultural Science & Technology
    • /
    • v.19 no.3
    • /
    • pp.367-372
    • /
    • 2001
  • 'Kyoho' grape (Vitis labruscana L.) has currently cropped twice a year in plastic greenhouses. However, there are problems with low fruit quality in the second cropping owing to low temperatures and short photoperiods. This experiment was conducted to investigate the effect of root zone heating and $CO_2$ enrichment in plastic greenhouse on the vine growth and fruit quality of 'Kyoho' grape in double cropping system. The internode length of shoots, leaf area and leaf dry weight at the treatment of soil heating near root zone was significantly different regardless of $CO_2$ enrichment. There were no significant differences in fruit bunch and berry weight, titratable acidity, coloration degree and berry shattering among the treatments, but the soluble solids significantly increased by root zone heating. Photosynthetic rate increased with increasing $CO_2$ concentration from 300 to $800{\mu}mol{\cdot}mol^{-1}$ in sunny day, whereas it didn't increase in cloudy day regardless of $CO_2$ enrichment.

  • PDF

Impact of Sulfur Dioxide Impurity on Process Design of $CO_2$ Offshore Geological Storage: Evaluation of Physical Property Models and Optimization of Binary Parameter (이산화황 불순물이 이산화탄소 해양 지중저장 공정설계에 미치는 영향 평가: 상태량 모델의 비교 분석 및 이성분 매개변수 최적화)

  • Huh, Cheol;Kang, Seong-Gil;Cho, Mang-Ik
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.187-197
    • /
    • 2010
  • Carbon dioxide Capture and Storage(CCS) is regarded as one of the most promising options to response climate change. CCS is a three-stage process consisting of the capture of carbon dioxide($CO_2$), the transport of $CO_2$ to a storage location, and the long term isolation of $CO_2$ from the atmosphere for the purpose of carbon emission mitigation. Up to now, process design for this $CO_2$ marine geological storage has been carried out mainly on pure $CO_2$. Unfortunately the $CO_2$ mixture captured from the power plants and steel making plants contains many impurities such as $N_2$, $O_2$, Ar, $H_2O$, $SO_2$, $H_2S$. A small amount of impurities can change the thermodynamic properties and then significantly affect the compression, purification, transport and injection processes. In order to design a reliable $CO_2$ marine geological storage system, it is necessary to analyze the impact of these impurities on the whole CCS process at initial design stage. The purpose of the present paper is to compare and analyse the relevant physical property models including BWRS, PR, PRBM, RKS and SRK equations of state, and NRTL-RK model which are crucial numerical process simulation tools. To evaluate the predictive accuracy of the equation of the state for $CO_2-SO_2$ mixture, we compared numerical calculation results with reference experimental data. In addition, optimum binary parameter to consider the interaction of $CO_2$ and $SO_2$ molecules was suggested based on the mean absolute percent error. In conclusion, we suggest the most reliable physical property model with optimized binary parameter in designing the $CO_2-SO_2$ mixture marine geological storage process.