• Title/Summary/Keyword: 지연성능

Search Result 3,823, Processing Time 0.028 seconds

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

Effect of microwave radiation on physical special quality of normal, high amylose and waxy corn starches (마이크로웨이브를 조사한 옥수수전분의 물리적 특성변화)

  • Lee Su Jin;Choe Yeong Hui
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.15 no.1
    • /
    • pp.113-125
    • /
    • 2004
  • Effect of microwave radiation on physico-chemical properties of cor'n starches was studied. Waxy com, com and high amylose com starches of varying moisture content(20~35%) were subjected to microwave processing(2450MHz) at $120^{\circ}$ and the experimental starch samples were examined by a X-ray diffractometry, rapid viscosity analyzer(RVA) and. with the samples in temperature was observed and the peaks of high amylose com starches at $2^{\circ}$=5.0, 15.0 and $23.0^{\circ}$, were disappeared indicating the melting of crystallines while those of com and waxy com had not changed. A change in gelatinization pattern was observed in the case of corn starches from type A with nearly no peak-viscosity and breakdown to type C. Except a decreased viscosity, no change was observed in those of waxy com starches.

  • PDF

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

ANC Caching Technique for Replacement of Execution Code on Active Network Environment (액티브 네트워크 환경에서 실행 코드 교체를 위한 ANC 캐싱 기법)

  • Jang Chang-bok;Lee Moo-Hun;Cho Sung-Hoon;Choi Eui-In
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9B
    • /
    • pp.610-618
    • /
    • 2005
  • As developed Internet and Computer Capability, Many Users take the many information through the network. So requirement of User that use to network was rapidly increased and become various. But it spend much time to accept user requirement on current network, so studied such as Active network for solved it. This Active node on Active network have the capability that stored and processed execution code aside from capability of forwarding packet on current network. So required execution code for executed packet arrived in active node, if execution code should not be in active node, have to take by request previous Action node and Code Server to it. But if this execution code take from previous active node and Code Server, bring to time delay by transport execution code and increased traffic of network and execution time. So, As used execution code stored in cache on active node, it need to increase execution time and decreased number of request. So, our paper suggest ANC caching technique that able to decrease number of execution code request and time of execution code by efficiently store execution code to active node. ANC caching technique may decrease the network traffic and execution time of code, to decrease request of execution code from previous active node.

Antimicrobial Activity of GC-l00X against Major Food-Borne Pathogens and Detaching Effects of It against Escherichia coli O157:H7 on the surface of Tomatoes (GC-100X의 주요 식품위해 미생물에 대한 항균효과와 토마토 표면에 부착된 Escherichia coli O157:H7에 대한 세척 효과)

  • 박용호;권남훈;김소현;김지연;임지연;김준만;정우경;박건택;배원기
    • Journal of Food Hygiene and Safety
    • /
    • v.17 no.1
    • /
    • pp.36-44
    • /
    • 2002
  • GC-l00X is non-corrosive alkaline ionic water (pH 12). It is composed of hydroxyl radicals and supplemented with xylitol. Its antimicrobial activity was examined against 6 major food-borne pathogens; Staphylococcus aureus FRI 913, Salmonella enterica serova Enteritidis ATCC 13076, S. enterica serova Typhimurium Korean isolate, Vibrio parahaemolyticus ATCC 17803, Escherichia coli O157:H7 ATCC 43894 and Pseudomonas aeruginosa KCTC 1637 at three different temperatures (4$^{\circ}C$, $25^{\circ}C$ and 36$^{\circ}C$) with or without an organic material (2% yeast extract), respectively. The antimicrobial activities showed over 4 log-reductions (1.0$\times$10$^4$CFU/ml reduction) against all pathogens reacted at 37$^{\circ}C$ for 3 hours in the absence of the organic material. The activities showed same results when GC-l00X was diluted with same volume of distilled water or standard hard water (CaCO$_3$300 ppm). Its antimicrobial activity was more effective and quicker in Gram-negative bacteria than Gram-positive bacteria. Its washing efficacy against E. coli O157:H7 exposed to the surfaces of tomatoes (grapes) was compared with that of the other sanitizers such as other kitchen synthetic detergent and 100-ppm chlorine water. For the toxicological evaluation of the sanitizers, viable counts of E. coli O157:H7 penetrated into the core of tomatoes after washing products were also compared. The result revealed that GC-100X stock solution and its 5% diluted solution had similar washing effects to 100-ppm chlorine water and more effective than the other kitchen synthetic detergent. This result indicated that GC- l00X had antimicrobial activity and no toxicological side effects, therefore, could be useful for a new sanitizer to use in flood safety and kitchen hygiene.

A Non-Calibrated 2x Interleaved 10b 120MS/s Pipeline SAR ADC with Minimized Channel Offset Mismatch (보정기법 없이 채널 간 오프셋 부정합을 최소화한 2x Interleaved 10비트 120MS/s 파이프라인 SAR ADC)

  • Cho, Young-Sae;Shim, Hyun-Sun;Lee, Seung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.63-73
    • /
    • 2015
  • This work proposes a 2-channel time-interleaved (T-I) 10b 120MS/s pipeline SAR ADC minimizing offset mismatch between channels without any calibration scheme. The proposed ADC employs a 2-channel SAR and T-I topology based on a 2-step pipeline ADC with 4b and 7b in the first and second stage for high conversion rate and low power consumption. Analog circuits such as comparator and residue amplifier are shared between channels to minimize power consumption, chip area, and offset mismatch which limits the ADC linearity in the conventional T-I architecture, without any calibration scheme. The TSPC D flip-flop with a short propagation delay and a small number of transistors is used in the SAR logic instead of the conventional static D flip-flop to achieve high-speed SAR operation as well as low power consumption and chip area. Three separate reference voltage drivers for 4b SAR, 7b SAR circuits and a single residue amplifier prevent undesirable disturbance among the reference voltages due to each different switching operation and minimize gain mismatch between channels. High-frequency clocks with a controllable duty cycle are generated on chip to eliminate the need of external complicated high-frequency clocks for SAR operation. The prototype ADC in a 45nm CMOS technology demonstrates a measured DNL and INL within 0.69LSB and 0.77LSB, with a maximum SNDR and SFDR of 50.9dB and 59.7dB at 120MS/s, respectively. The proposed ADC occupies an active die area of 0.36mm2 and consumes 8.8mW at a 1.1V supply voltage.

Effect of Air Contents, Deicing Salts, and Exposure Conditions on the Freeze-Thaw Durability of the Concrete (콘크리트의 동결융해 내구성에 공기량, 제설제, 노출조건이 미치는 영향에 관한 연구)

  • Lee, Byung-Duk
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.107-113
    • /
    • 2010
  • In this study, the relative effects of low-chloride deicier(LCD) and two other deicing agents on the scaling of concrete were conducted in a series of tests at laboratory accordance with the ASTM C 672. The solutions concentration of deicers tested included 1, 4, 10%. Tap water was used as control. The amount of scaling was evaluated gravimetrically. As test result of deicer solution types, when applied to 4% solutions, surface scaling of concrete after 56 freeze-thaw cycles was produced significantly as about 9 times on LCD solution, as about 18 times on $CaCl_2$ solution, and as about 33 times on NaCl solution comparing with tap water. As test result of deicer solution concentrations, relatively low concentrations (of the 4% by weight) of deicer were produced more surface scaling than higher concentrations (of the 10% by weight) or lower concentrations (of the 1% by weight) of deicer. It show that the damaging concentration is of the order of 3~4% for previous research result. It appears that the mechanism of surface scaling is primarily physical rather than chemical. Also, the effect of chloride deicier types, freeze-thaw cycling, and air contents on the performance of concrete was experimentally investigated. The results show that the concrete specimens subjected to freeze-thaw cycling scaled more severely in exposure to deicing salt than those in non-exposure to deicing salt, weight losses of the specimens tested in exposure to deicing salt were twice as much as those tested in non-exposure to deicing salt. Relative dynamic modulus of elasticity of concrete specimens decreased more quickly in exposure to deicing salt than in non-exposure to deicing salt. Also, relative dynamic modulus of elasticity of concrete specimens in exposure to sodium chloride deicing salt was decreased more quickly comparing with exposure to LCD salt. It is also shown that the chloride contents according to concrete specimen depths was more largely in exposure to LCD salt. When concrete specimen is exposed to chloride deicing salts and freeze-thaw cycling, performance degradation in the entrained air concrete(AE concrete) retarded more considerably comparing with non-entrained air concrete(Non-AE concrete).

Isolation and Identification of Lactic Acid Bacteria with Probiotic Activities from Kimchi and Their Fermentation Properties in Milk (전통 김치로부터 Probiotic 유산균의 분리 및 우유 발효 특성)

  • Lim, Young-Soon;Kim, JiYoun;Kang, HyeonCheol
    • Journal of Dairy Science and Biotechnology
    • /
    • v.37 no.2
    • /
    • pp.115-128
    • /
    • 2019
  • Lactic acid bacteria obtained from traditional Kimchi were selected on the basis of their caseinolytic activity and lactose usability and examined for availability as a starter in probiotic activity. Thirty-two strains were selected as lactic acid producing bacteria in BCP agar, and two strains (KC23 and KF26) with more than 90% resistance for both acid and bile salts were selected. The two strains were identified as L. plantarum (KC23) and L. paracasei (KF26) by API 50 CHL system and 16S rRNA sequence analysis. L. plantarum (KC23) was finally selected based on its biochemical characteristics for lactose and raffinose usability. Free tyrosine content increased rapidly in 10% skimmed milk medium, from $24.1{\mu}g/mL$ after 8 h to $43.9{\mu}g/mL$ after 16 h. Additionally, the caseinolytic clear zone of 12 mm of L. plantarum (KC23) was greater than the 9 mm zone of commercial L. acidophilus CSLA. The bacterium exhibited mesophilic growth and yielded $8.9{\times}10^8CFU/mL$ when incubated at $37^{\circ}C$ for 12 h at pH 4.25. Moreover, L. plantarum KC23 exhibited antibacterial activity as it formed a clear zone of 8-13 mm for the 5 pathogens. Adherent activity was 2.23 fold higher than that of LGG. The acidity of 10% skimmed milk fermented for 12 h was 0.74%.

Effects of Elevated Temperature after the Booting Stage on Physiological Characteristics and Grain Development in Wheat (밀에서 출수 후 잎의 생리적 특성 및 종실 생장에 대한 수잉기 이후 고온의 효과)

  • Song, Ki Eun;Choi, Jae Eun;Jung, Jae Gyeong;Ko, Jong Han;Lee, Kyung Do;Shim, Sang-In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.66 no.4
    • /
    • pp.307-317
    • /
    • 2021
  • In recent years, global warming has led to frequent climate change-related problems, and elevated temperatures, among adverse climatic factors, represent a critical problem negatively affecting crop growth and yield. In this context, the present study examined the physiological traits of wheat plants grown under high temperatures. Specifically, the effects of elevated temperatures on seed development after heading were evaluated, and the vegetation indices of different organs were assessed using hyperspectral analysis. Among physiological traits, leaf greenness and OJIP parameters were higher in the high-temperature treatment than in the control treatment. Similarly, the leaf photosynthetic rate during seed development was higher in the high-temperature treatment than in the control treatment. Moreover, temperature by organ was higher in the high-temperature treatment than in the control treatment; consequently, the leaf transpiration rate and stomatal conductance were higher in the control treatment than in the high-temperature treatment. On all measuring dates, the weight of spikes and seeds corresponding to the sink organs was greater in the high-temperature treatment than in the control treatment. Additionally, the seed growth rate was higher in the high-temperature treatment than in the control treatment 14 days after heading, which may be attributed to the higher redistribution of photosynthates at the early stage of seed development in the former. In hyperspectral analysis, the vegetation indices related to leaf chlorophyll content and nitrogen state were higher in the high-temperature treatment than in the control treatment after heading. Our results suggest that elevated temperatures after the booting stage positively affect wheat growth and yield.