• Title/Summary/Keyword: 지수형 온도변화

Search Result 34, Processing Time 0.025 seconds

Measurement of Surface Heat Transfer Using Exponential Temperature Variations (지수형 온도변화를 이용한 표면 열전달의 측정)

  • Park, Byung Kyu;Hong, Taek;Park, Sang Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1121-1128
    • /
    • 1999
  • A single blow, transient testing method for determining the heat transfer characteristics of heat exchanger surfaces are presented. The exponential inlet temperature variations were made using screen mesh with small time constant and frontal velocities of the test section. The system is used to investigate the usefulness of a model with exponential inlet temperature variations. A data reduction program is developed to calculate the temporally and spatially averaged heat transfer coefficient using the measured disturbance and response of the fluid temperature. The results are compared with the existing theoretical and experimental data for parallel plate stacks. It was recommended to take an average for the time greater than the 99% of the final temperature had reached in order to obtain fairly good results.

A Study of the Development of a Korea Wind Chill Temperature Index (II) - A Preliminary Study of the Development of the Korea Wind Chill Temperature Index - (한국형 체감온도지수 개발연구(II) - 체감온도지수 개발을 위한 예비실험 -)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Byung-Soo;Yoon, Sook-Hee;Lee, Jong-Tae;Nam, Jae-Cheol;Ryoo, Sang-Boom;Kim, Eun-Byul;Park, Gil-Un;Song, Jeong-Hui
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.891-902
    • /
    • 2007
  • This paper aims to develop a Korea wind chill temperature index using an experimental method. For this, the researchers carried out a preliminary experiment in order to of for provisions necessary for the selection and safety of test participants, accuracy of experiment, and readiness for various situations that may occur during experiment. The researchers also investigated test subjects' safety and experiment conditions in which wind speed changes from calm condition into strong wind speed condition under the constant air temperature of $5^{\circ}C$. The results of this study are as follows. With regard to the variation of facial skin temperature such as forehead, cheek, nose, and chin, the skin temperature of cheek closely appears to depend on the change of air temperature and wind speed, exhibit a stable variation trend of skin temperature, and indicate the lowest temperature than any other facial parts. The skin temperature of women tends to be more sensitive than that of man and the skin temperature of human tends to decrease at weak wind speed under constant air temperature. It was also found that it is not necessary to take the influence of standard wind speed into consideration when a wind chill index is developed.

Comparion of Vitality among Three Cool-Season Turfgrasses during Summer using Chlorophyll Fluorescence (엽록소형광을 이용한 하절기 동안 한지형 잔디 3종의 활력도 비교 분석)

  • Seok Chan Koh
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2021.04a
    • /
    • pp.44-44
    • /
    • 2021
  • 본 연구는 제주지역의 골프 코스에서 하절기 고온기간에 온도의 상승을 비롯한 다양한 환경변화로 인하여 생육 장애가 심한 한지형 잔디인 perennial ryegrass (Lolium perenne L.), Kentucky bluegrass (Poa pratensis L.), creeping bentgrass (Agrostis palustris Huds.) 3종에 대하여 엽록소형광과 엽록소지수를 측정하여 골프 코스와 스포츠 필드에서 잔디 선정과 관리를 위한 기본적인 정보를 얻기 위하여 수행하였다. Fo 값은 3종 모두 하절기 초기에는 낮고 후기에 다소 증가하는 양상을 보였다. 그러나, perennial ryegrass의 경우는 하절기 초기와 후기 간의 Fo 값의 변화가 컸으며, 특히, 후기에 Fo 값은 다른 2종 월등하게 보다 높았다. Fm 값은 3종 모두 하절기 초기에는 낮고 하절기 후기에 증가하였으나 3종 간의 차이는 크지 않았다. 광계 II의 광화학적 효율의 척도인 Fv/Fm 값은 3종 모두에서 하절기 초기에 낮고, 후기에 다소 증가하는 양상을 보였으나, 하절기 후기에 Kentucky bluegrass와 creeping bentgrass는 perennial ryegrass에 비해 Fv/Fm 값이 다소 높아 하절기 고온에서도 보다 더 잘 적응하는 것으로 보인다. 엽록소지수는 perennial ryegrass와 Kentucky bluegrass에서는 뚜렷하게 하절기 초기에는 낮고 후기에 높은 양상을 보였으나, creeping bentgrass는 조사기간 내내 낮은 상태를 유지하였다. 이상의 결과로부터 Kentucky bluegrass가 하절기 후기의 고온이나 빈번한 강우에 의한 습한 조건에 가장 강하고, perennial ryegrass가 가장 취약한 것으로 사료된다.

  • PDF

MBE로 성장한 CdTe 박막의 photoconductivity

  • 임재현;허유범;류영선;전희창;현재관;강철기;강태원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.113-113
    • /
    • 1998
  • C CdTe와 HgCdTe는 광전소자나 태양전지,x 선 및 y 선 감지 소자 그리고 적외선 감지소 자로의 웅용둥으로 인하여 많은 연구가 진행되고 있다. 광전소자를 제작함에 있어서 깊은 준위나 얄은 준위에 있는 몇들은 운반자 수명에 매우 큰 영향을 미치고 있음에도 불구하고 광전도도 측정에 의한 운반자 수명 연구에 대하여는 보고된 것이 별로 없다. 이에 본 논문에서는 CdTe 시료의 광전도도를 측정하여 운반자 수명 및 깊은 준위의 위치를 알아보았다 M MBE방법을 이용하여 CdTe 기판위에 In을 도핑한 CdTe를 성장하였다. 광전도 붕괴(PCD) 측정은 300 K에서부터 400 K까지 온도를 변화시켜주면서 측정을 하였고 광원으로서 G GaP- LED를 사용하였으며 전압 신호를 읽기 위하여 Tektronix 2430A 오실로스코프를 이용하 였다 .. Fig. 1. 에서 보인바와 같이 광전도 붕괴곡선은 접선으로 나타낸 하나의 지수 함수적 붕 괴(a2exp( -t/ r 2))보다는 설선으로 나타낸 두 개의 지수함수적 붕괴(alexp( νr 1)+a2exp( -νr 2)) 가 더욱 잘 실험결과와 일치함을 알 수 있었다. 이러한 것은 과잉 전하에 대한 깊은준위를 가 지고 있는 반도체물질에서 일반적으로 관찰되는 것으로 시료가 n 형이기 때문에 소수 운반자 인 정공의 벚에 의한 것으로 생각된다 .. Fig. 2. 에서는 운반자 수명의 온도에 대한 변화를 나타 낸 것이다. 온도가 증가함에 따라 운반자 수명이 감소하는 경항올 보이고 있으며 이것올 이용 하여 딪익 활성화 에너지를 계산 하여 본 결과 0.35 eV 와 0.43 eV염을 알수 있었다.

  • PDF

Effects of longitudinal conduction on the performance of heat transfer surfaces (유동방향의 열전도가 전열면의 성능에 미치는 영향)

  • Park, Byung-Kyu;Hong, Taek;Park, Sang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.561-569
    • /
    • 1999
  • The effects of longitudinal heat conduction on the performance of heat transfer surfaces are investigated by using a single-blow method. In the transient testing method for determining the heat transfer characteristics, exponential inlet temperature variations are made by using screen-mesh heater with small time constant and low frontal velocities of the test section, and the experimentally determined inlet temperature profile is used as the inlet fluid temperature condition. The effects of longitudinal heat conduction are negligible only if $\gamma^\act<0.05\;and \;N_{tu}\le3$ and should be considered if $N_{tu}\le3$ The test results ate compared with the existing theoretical and experimental data and the validity of this technique is confirmed by the good agreement.

  • PDF

Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom (자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가)

  • Lee, Hyun-Kyung;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.895-900
    • /
    • 2019
  • Ultrasound is known to be harmless to the human body and is widely used in obstetrics and gynecology to confirm the diagnosis and development status of fetus. Diagnosis Although long - term use of ultrasound may cause changes in body temperature, studies on the uterine temperature changes due to ultrasound have been lacking. The purpose of this study was to investigate the change of temperature according to ultrasonic scanning time using a self - produced uterine model phantom. Ultrasound equipment and a 4MHz convex probe were used to construct the uterine model phantom similar to the human uterus using acrylic and pig uterus, which are tissue equivalents. Three probe type thermometers were installed to measure the inside of the acrylic water tank, the uterus, and the atmospheric temperature. The temperature of the uterine phantom was ascertained by measuring the temperature of the subject for 6 hours, 361 times. In this study, the possibility of human body temperature elevation due to ultrasound could be confirmed and this study will be used as the basic data of ultrasonic heat absorption study.

금속선을 삽입한 고체 추진제의 연소 특성

  • 유지창;박영규;김인철;임유진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.131-137
    • /
    • 1996
  • HTPB/AP/Al이 주성분인 2종의 혼합형 추진제를 대상으로 4종의 금속선(Ag, Cu, Al, Ni-Cr)윰 각각 삽입하여 금속선의 직경(0.1~0.8mm)과 연소 압력에 따른 금속선에 인접한 고체 추진제의 연소 속도 증가비($r_w$/$r_sb$)와 압력 지수(n)의 변화를 고찰하였다. 금속선을 추진제에 삽입함으로써 추진제의 $r_w$/$r_sb$ 는 크게 중가하였고, 1000 psia의 압력에서의 최대 6.59배 증가하였다. 그러나 녹는 점이 비교적 낮은 Al 선이나 Ag선은 금속선 직경이 작아짐에 따라 한계 직경에서 $r_w$가 급격히 감소하는 최대값이 존재하였다. 자연 발화 온도와 금속선으로 전달되는 열원인 연소 기체 불꽃 온도로 구성된 무차원군을 Buckingham pi 정리에 의해 구해진 $r_w$/$r_sb$ 에 대한 기존의 무차원 실험식에 추가로 적용하여 계산해 본 결과, 자연 발화 온도는 고려하지 않고 금속선의 녹는 점과 연소 기체의 불꽃 온도를 무시한 Hsing 의 실험식에 의해 계산된 결과보다 표준 편차가 45%이상 줄어듬을 알 수 있었다.

  • PDF

Hydrogen Evolution Rates of the Aluminum-Air Unit Cell (알루미늄-공기 단위전지의 수소발생속도)

  • Shim Eun-Gi;Doh Chil-Hoon;Moon Seong-In;Hwang Young-Gi
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.4
    • /
    • pp.166-171
    • /
    • 2001
  • In an aluminum-air unit cell used alkaline solution, Hydrogen evolution rates were investigated far the observation of the effects of alloy element, inhibitor and its concentration in electrolyte, KOH concentration, solution temperature, and current density loaded to cell. Hydrogen evolution rates were reduced up to $50\%$ by saturating the solution with ZnO, while ZnAc(Zinc Acetate) did not work as inhibitor. The inhibition effect of ZnO increased with increasing the KOH concentration and solution temperature. They were linearly increased with the KOH concentration and current density in first order and exponentially increased with the solution temperature.

Dispertion Effect of Hydration Heat due to Materials and Standard Variation of Embedded Heat Pipe (매입형 히트파이프의 재질 및 규격변화에 따른 수화열 분산 효과)

  • Kim, Myung-Sik;Yeom, Chi-Sun;Baek, Dong-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.111-116
    • /
    • 2009
  • The cracking due to hydration heat in mass concrete must be resolved to improve the stability and durability of concrete structures. In this study, the economic efficiency was improved by replacing a copper pipe with a steel one for the heat pipe, and the heat pipe was standardized to significantly improve the operation efficiency, such as the processing, transport, assembly, and construction time. As a result of the experiment, the peak temperature of the ICSHP, ISSHP, and ISUHP specimens decreased by about $7.2{\sim}10.9^{\circ}C$ compared to the OPC specimen and the probability of a thermal crack being generated in the ICSHP, ISSHP, and ISUHP specimens decreased by up to 84~88%.

Estimation of Change in Soil Carbon Stock of Pinus densiflora Forests in Korea using KFSC Model under RCP 8.5 Climate Change Scenario (한국형 산림토양탄소모델(KFSC Model)을 이용한 RCP 8.5 기후변화 시나리오 하에서의 국내 소나무림 토양탄소 저장량 장기 변화 추정 연구)

  • Park, Chan-woo;Lee, Jongyeol;Yi, Myongjong;Kim, Choonsig;Park, Gwan Soo;Kim, Rae Hyun;Lee, Kyeong Hak;Son, Yowhan
    • Journal of Climate Change Research
    • /
    • v.4 no.2
    • /
    • pp.77-93
    • /
    • 2013
  • Global warming accelerates both carbon (C) input through increased forest productivity and heterotrophic C emission in forest soils, and a future trend in soil C dynamics is uncertain. In this study, the Korean forest soil carbon model (KFSC model) was applied to 1,467,458 ha of Pinus densiflora forests in Korea to predict future C dynamics under RCP 8.5 climate change scenario (RCP scenario). Korea was divided into 16 administrative regions, and P. densiflora forests in each region were classified into six classes by their stand ages : 1 to 10 (I), 11 to 20 (II), 21 to 30 (III), 31 to 40 (IV), 41 to 50 (V), and 51 to 80-year-old (VI+). The forest of each stand age class in a region was treated as a simulation unit, then future net primary production (NPP), soil respiration (SR) and forest soil C stock of each simulation unit were predicted from the 2012 to 2100 under RCP scenario and constant temperature scenario (CT scenario). As a result, NPP decreased in the initial stage of simulation then increased while SR increased in the initial stage of simulation then decreased in both scenarios. The mean NPP and SR under RCP scenario was 20.2% and 20.0% higher than that under CT scenario, respectively. When the initial age class was I, IV, V or VI+, predicted soil C stock under CT scenario was higher than that under RCP scenario, however, the countertrend was observed when the initial age class was II or III. Also, forests having a lower site index showed a lower soil C stock. It suggested that the impact of temperature on NPP was higher when the forests grow faster. Soil C stock under RCP scenario decreased at the end of simulation, and it might be derived from exponentially increased SR under the higher temperature condition. Thus, the difference in soil C stock under two scenarios will be much larger in the further future.