• Title/Summary/Keyword: 지붕유출

Search Result 32, Processing Time 0.025 seconds

An Experimental Runoff Formula in Building Roof Area for On-site Rainwater Management (On-site 방식 빗물관리를 위한 건축물 지붕면의 유출특성 경험식 수립)

  • Kim, Young-Jin;Han, Moo-Young;Kim, Yong-Ha;Mun, Jung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.2
    • /
    • pp.171-176
    • /
    • 2009
  • This study proposes an experimental formula for cumulative runoff analysis in building roof for on-site rainwater management. We can not find an appropriate method for roof runoff analysis because of its small area scale. A new runoff equation formula for rainfall depth(D) and cumulative runoff volume(V) is developed on roof runoff conditions. Reliability of the formula is verified with field experimental runoff monitoring for two years in two buildings of rainwater management system. This experimental runoff formula can root the cumulative runoff volume from roof area and rainfall depth, then develop reasonable inflow condition for rainwater retention tank design.

Evaluation on the environmental effects of rain garden treating roof stormwater runoff (지붕 강우유출수를 처리하는 빗물정원의 환경적 효과 평가)

  • Flores, Precious Eureka D.;Maniquiz-Redillas, Marla C.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.10-15
    • /
    • 2016
  • In this research, the environmental effects of rain garden when applied to a stormwater runoff originated from a rooftop were evaluated. The rain garden that was utilized as LID represents less than 1% of the catchment area that it drains. Storm event monitoring was conducted from March 2012 to August 2014 on a total of 19 storm events. In the 19 storm events that was monitored only 32% produced an outflow which has a mean rainfall characteristic of approximately 25 mm. With the application of rain garden, hydrologic improvement was observed as the facility exhibit a delay and reduction in the production of runoff and peak flows as the rainfall progresses. Furthermore, in terms of pollutant reduction, it was observe that the rain garden showed a generally satisfactory performance in reducing pollutants. In addition to this, the rain garden also has additional attributes that adds to the aesthetic appeal of the surrounding environment as well as in the lives of the people. The findings of this research will help in the further improvement and reinforcement of LID designs.

Characteristics of EMCs for Roof Runoff (강우시 지붕유출수의 EMCs 및 특성비교)

  • Hong, Jung Sun;Geronimo, Franz Kevin F.;Mercado, Jean Margaret R.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.657-665
    • /
    • 2012
  • The development projects distort the natural water circulation system and increase the non-point source pollution by changing the natural cover type. The low impact development (LID) techniques are considering as new development approach to decrease the ecological- and hydrological impacts from high imperviousness rate. The high imperviousness rate is because of the construction of building, parking lot and road for human activities. Knowing the basic characteristics of rood runoff can give the direction for setting up the water management strategy. The monitoring results show the pollutant EMCs of roof runoff are 3~13 times lower than EMCs of the road and parking lot. The pollutant sources from roof runoff are mainly from leafs, cigarette butts, atmospheric deposition and materials of the roof. The EMC is occurred around 15minutes later after starting runoff and more than 8 storm events are needed to have the average EMCs.

Rainfall-runoff Analysis Considering the Effect of High-rise Building (초고층 건물의 영향을 고려한 강우-유출 과정 해석)

  • Cho, Eunsaem;Kim, Soeun;Lee, Munseok;Yoo, Chulsang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.107-107
    • /
    • 2020
  • 본 연구의 목적은 실제 규모의 초고층 건물을 고려하여 강우-유출 과정을 해석하고, 초고층 건물이 강우-유출 과정에 미치는 영향을 파악하는 것이다. 초고층 건물을 고려하기 위해 건물의 지붕과 벽면을 각각 독립적인 소유역이라 가정하여 분석을 수행하였다. 특히, 건물의 벽면 소유역에는 바람의 영향을 받아 비스듬하게 내리는 강우를 입력자료로 적용하였다. 각 소유역에서 발생하는 유출은 shot noise process 기반 강우 유출-모형으로 모의되었다. Shot noise process 기반 강우-유출 모형을 이용하여 초고층 건물의 벽면과 지붕에서 발생하는 유출을 독립적으로 모의할 수 있었다. 실험실 환경에서 건물 모형이 존재할 때의 강우-유출 과정을 관측하였으며, shot noise process 모형으로 모의한 유출수문곡선과 관측 유출수문곡선이 유사한 특성을 보이는 것을 알 수 있었다. 서울시 강남구에 위치한 실제 규모의 초고층 건물을 고려하여 유출수문곡선을 유도해본 결과, 첨두유출량이 기존 유출수문곡선과 최소 6.5%에서 최대 67.5%까지 차이나는 것으로 확인되었다. 본 연구의 결과는 초고층 건물이 다수 존재하는 도시유역의 강우-유출 해석 결과의 정확성을 향상시킬 수 있을 것으로 판단된다.

  • PDF

A Determination Method of a Rainwater Retention-Pumping System Combination for Runoff Control from Building Roof Area (지붕면 유출제어를 위한 빗물의 저장-펌프 시스템 조합 결정방안)

  • Kim, Young-Jin;Han, Moo-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.495-499
    • /
    • 2008
  • This study developed a determination method for a rainwater retention-pumping combination system for roof runoff control. The outflow and stored water volume in the rainwater system was simulated using a water balance equation. Its result is presented in the TPP (Tank capcity-Peak outflow-Pumping rate) curves for rainfall return periods. In a case study on reduction of the peak flow rate of 100-year return period to 5-year in Seoul, The range of pumping rate for $100m^2$ roof area is determined as $0{\sim}25{\ell}$/min. Additionally, retention volume of $8.5{\sim}10m^3$ can be combined with the pumping rate range. That is to say an effective combination of a retention-pumping system capacity can be determined from a system of $8.5m^3$ tank with $25{\ell}$/min to $10m^3$ tank without pump. Using the TPP curves, engineers can determine the effective combination range of retention & pumping system capacity. Furthermore, that can be helpful to decide a detail system capacity for field condition.

  • PDF

The Basic Study for the Roof-Harvested Rainwater Quality Characteristics as a Function of Rainfall Duration (강우지속시간에 따른 건물지붕빗물의 성상특성변화에 대한 기초 연구)

  • Kim, Sung-Pyo;Kim, Doo-Cheol;Oh, Jun-Sik;Kim, Lee-Hyung;Min, Kyung-Suk
    • Journal of Wetlands Research
    • /
    • v.14 no.1
    • /
    • pp.11-20
    • /
    • 2012
  • The aim of this study is to accumulate the data about the roof-harvested rainwater quality characteristics for the better rainwater management. According to the results of rainwater quality indicators (pH, COD, TSS, T-N, T-P, $NH_4$-N, $NO_3$-N, enteric bacteria, heterotrophs, Pb, Cd, Cu), the rainwater qualities of the first flush of roof-harvested was the most polluted about 2 or 3 times (more than 100 times in microbial contamination) compared to the qualities of directly collected rainwater. In the first 10 min flush, over the 60% amounts of contaminant were released from the roof during 30 minute rainwater monitoring. Through statistical factor analysis, relatively close items(variables) can be categorized. It is expected that the continuous monitoring of the roof-harvested rainwater will help to design the safe and economical rainwater storage system in Korea.

Methodology for determination of rainwater storage capcity (우수저류조 용량 결정 방법)

  • Maeng, Seung Jin;Hwang, Ju Ha;Kim, Da Ye
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.423-423
    • /
    • 2018
  • 전세계적으로 집중호우, 홍수, 가뭄 등 기상이변이 빈번히 발생하고 있으며, 홍수기와 갈수기가 뚜렷해지고, 이에 따라 수자원 확보에 애로사항이 발생하고 있다. 이를 해결하기 위하여 정부는 "물의 재이용촉진 및 지원에 관한 법률"을 재정하여 효율적인 빗물 관리에 주력을 하고 있으나, 체계적인 빗물관리는 미흡한 실정이다. 즉 수자원을 효율적으로 보관하고 관리할 시스템 구축이 필요하다. 본 연구에서는 재배 작물에 대한 농업용수 확보를 위한 빗물저류조를 시공 및 모니터링을 하기 위하여 먼저 보은군 회인면 오동리의 기상 및 수문특성 조사를 실시하였고, 확률강우량을 산정하기 위해 보은기상관측소의 지속기간별 강우 자료를 수집하여 확률분포를 선정하고 매개변수를 산정하였다. 이에 따른 적합도 검정 결과 최적 확률분포형을 산정하였다. 분석한 결과를 통해 대상지역의 집수되는 면적에 내리는 유출량을 산정하였으며, 집수되는 유형은 지붕으로서 그에 대한 면적은 $120.0m^2$로 측정되었고, 지붕에 대한 유출계수로서 0.9의 값을 적용하였다. 지붕에서 집수되는 유출량의 값을 산정하였으며, 6월의 50년 빈도에서 부족한 9.4톤은 집수된 유출량으로 보충할 수 있는 것으로 판단된다. 따라서 50년 빈도의 10톤을 저류할 빗물은 저류조에서 30%의 여유율을 두어 13톤으로 저류조를 설계하는 것이 적정할 것으로 판단된다. 현재 빗물자원의 대부분은 바다로 유입되어 소모되거나, 하수로 유입되어 불필요한 고도처리공정이 진행되고, 하수처리장 용량에 과부하를 발생시키는 등 막대한 예산이 투입되고 있다. 갈수기시 농가에서 용수를 확보하기 위한 용수 운반장치 등 기반구축과 인력 부족으로 정상적인 용수공급의 어려움을 해결하기 위해서는 빗물자원을 용수로서 효율적으로 활용하기 위한 시스템의 구축이 필요할 것으로 사료된다.

  • PDF

Structural Analysis on A Steel Roof LNG Storage Tank (강재 지붕형 LNG 저장탱크 구조안전성평가)

  • Lee, Seung-Rim;Park, Jang-Sik;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.40-44
    • /
    • 2009
  • This is a comparative structural analysis for a steel roof LNG storage tank that has some advantages relatively in designing larger scale tanks and construction cost, etc. compared with a conventional concrete roof LNG storage tank as the capacity of LNG storage tanks is bigger. Structural analysis was performed on a 200,000$k{\ell}$ steel roof LNG storage tank and a concrete of the same capacity in condition of three critical load combination cases, a normal operation, a LNG spillage and seismic case by using finite element method. And comparative structural safety evaluation was carried out by using strength ratio in places of concrete wall, foundation and roof with a quantitative method.

  • PDF

The Effect of Roofing Materials for Using Harvested Rainwater (집수빗물이용을 위한 지붕면 재질의 영향)

  • Lee, Ju Young;Kim, Tschung-Il;Kim, Hyunwoo;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.623-629
    • /
    • 2012
  • The objective was to evaluate the quality of harvested rainwater of the roofing materials used and the presence of lichens/mosses on the roofing surface. This experiment was studied in the field where five pilot structures with different roofing materials (i.e., wooden shingle tiles, wooden shingle tiles (including mosses), concrete tiles, clay tiles [Gi-Wa] and slate tiles) were installed. As a result, the clay tiles [Gi-Wa] was found to be the most suitable for rainwater harvesting applications. It was due to the disinfection from ultraviolet light and high temperature according to characteristic of roofing materials. Comparison with quality of rainwater on that wooden shingle tiles with and without including mosses, which may affect the concentration of and wooden shingle tiles including mosses, mosses may affect concentration of TOC, nitrate, and sulfate. Additionally, the average concentration of asbestos was determined to be measured at $0.002/cm^3$ for the slate tiles. The value satisfied with it met the Ministry of Environment's Multi-use facility standard and Ministry of Labor's Office standard ($0.01/cm^3$).

Evaluating the Effect of Low Impact Development on Yeongsan River Stream (영산강 수계 저영향개발(LID)의 수질효과 평가)

  • Kim, Seok-Gyu;Kang, Jea-Hong;Park, Se-Hwan;Ko, Kwang-Yong;Ha, Don-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.457-457
    • /
    • 2011
  • 저영향개발(LID, Low Impact Development)은 물순환체계 개선을 위해 녹색 공간의 확보, 자연형 공간 조성, 자연상태의 수문순환 기능의 유지 기법 등을 활용한 개발 대상지에서의 강우유출 및 비점오염원의 영향을 최소화할 수 있는 새로운 방법이다. LID는 강우 유출수의 지하침투, 강우 종료시 증발산량의 확보, 강우 유출수의 재이용 등을 통한 강우 유출량을 최소화하는 것에 그 목적이 있다. LID 방법은 우수저류 공원, 생태저류지, 지붕층 저류공원, 보도 저류공간, 인공습지, 완충녹지대, 수목 보존지대, 지붕층 배수관, 강우 저장조, 투수성 포장, 토양 개량, 불투수층 최소화, 비점오염원 저감 등으로 효율성, 경제성, 유연성, 합리성, 토지 가치증대 등의 장점이 있다. 영산강 수계의 BOD 배출부하량이 점오염원(21,019kg/일)과 비점오염원(50,047kg/일)의 비율이 3:7 로 비점오염원 배출부하량이 훨씬 큰 상태이다. 특히, 광주광역시, 농업용 토지, 축산계 등의 비점오염원이 영산강 수질에 크게 영향을 미치고 있다. 따라서 본 연구에서는 비점오염원의 영향이 큰 영산강 수계를 대상으로 앞으로 이루어지는 개발계획을 분석하여 LID 기법을 적용하였을 때 영산강 수질에 미치는 영향을 모델링을 통해 예측하고자 한다. 수질개선에 어느 정도의 효과가 있는지 검증하기 위해 국내 실정에 맞고 QUAL2E 모델을 근간으로 WASP5 모형의 장점들을 접목시켜 Bottle BOD의 반응기작 및 조류의 생산에 의한 유기물 증가, 탈질화 반응 등 정체수역에서 일어날 수 있는 반응기작을 모의할 수 있도록 보완한 QUALKO2 모형을 이용하여 그 효과를 모의하고자 한다. 본 연구를 통해 LID 기법이 도시화에 영향을 얼마나 덜 주는지, 수계의 비점오염원 효과를 통해 물순환 체계의 개선이 어느 정도로 어루어지는지에 대한 효과를 검증을 할 수 있는 계기가 될 수 있을 것으로 판단된다.

  • PDF