• Title/Summary/Keyword: 지멘스사

Search Result 2, Processing Time 0.016 seconds

국내외 정보

  • Korea Electrical Manufacturers Association
    • NEWSLETTER 전기공업
    • /
    • no.94-8 s.105
    • /
    • pp.32-47
    • /
    • 1994
  • PDF

Evaluation of Myocardial Oxygen Consumption with $^{11}C$-Acetate and 3D PET/CT: By Applying Recirculation Correction Method and Modified One-Compartmental Tracer Kinetic Modeling ($^{11}C$-Acetate와 3차원 PET/CT를 이용한 심근의 산소 소모량 평가: 재순환 교정법 및 수정 단일구획 추적자 동적 모델 적용)

  • Chun, In-Kook;Hwang, Kyung-Hoon;Lee, Sang-Yoon;Kim, Jin-Su;Lee, Jae-Sung;Shin, Hee-Won;Lee, Min-Kyung;Yoon, Min-Ki;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.275-284
    • /
    • 2008
  • Purpose: We intended to evaluate myocardial oxygen consumption ($MVO_2)$ by applying recirculation correction and modified one-compartment model to have a reference range of $MVO_2$ in normal young population and to reveal the effect of recirculation on time-activity curve (TAC). Materials and Methods: In nine normal male volunteers with mean age of $26.3{\pm}4.0$, $MVO_2$ was estimated with 925 MBq (25mCi) of $^{11}C$-Acetate (Neuroscience Research Institute, Gachon University of Medicine and Science, Incheon, Korea) and PET/CT (Biograph 6, Siemens Medical Solution, Germany). Analysis software such as $MATLAB^{(R)}$ v7.1 (Mathworks, Inc., United States), $Excel^{(R)}$ 2007 (Microsoft, United States), and $SPSS^{(R)}$ v12.0 (Apache Software Foundation, United States) were used. Twenty three frames were of $12{\times}10$, $5{\times}60$, $3{\times}120$, $2{\times}300's$ duration, respectively. The modified one-compartmental model and the recirculation correction method were applied. Statistical analysis was performed by using Test of Normality, ANOVA and Post-Hoc (Scheffe's) analysis, and p-value less than 0.05 was considered as significant. Results: The normal reference ranges of $MVO_2$ were presented as $3.18-4.64\;{\times}\;10^{-4}\;ml/g/sec$, $1.91-3.94\;{\times}\;10^{-4}\;ml/g/sec$, $4.31-6.40\;{\times}\;10^{-4}\;ml/g/sec$, $2.84-4.53\;{\times}\;10^{-4}\;ml/g/sec$ and $3.42-5.00\;{\times}\;10^{-4}\;ml/g/sec$ in the septum, the inferior wall, the lateral wall, the anterior wall and the entire wall, respectively. In addition, it was noted that the dual exponentiality of the clearance curve is due to the recirculation effect and that the characteristic of the curve is essentially mono-exponential. Conclusion: $^{11}C$-Acetate is a radiotracer worthwhile to assess $MVO_2$. Re-circulated $^{11}C$ can influence TAC of $^{11}C$ in myocadia and so the recirculation correction must be considered when measuring $MVO_2$.