• Title/Summary/Keyword: 지건축

Search Result 1,787, Processing Time 0.028 seconds

Case Study of the Roles and Characteristics of Community Gardens in Four North American Cities (북미 4개 도시 커뮤니티가든 사례조사에 의한 역할과 특성 비교 연구)

  • Shin, Myungjin;Choi, Jungmin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.26-40
    • /
    • 2018
  • As urban regeneration and revitalization projects become increasingly popular in Korea, interests in residential environment, landscape improvement and community activities have risen, resulting in increased interest in community garden, a type of urban agriculture. However, the concept of community garden in Korea is yet to be defined apart from the general concept of urban agriculture. Also, any discussion regarding a practical scheme for community gardens remains nascent. Therefore, in order to define and to understand community gardens, and to draw meaningful implications for the community garden research in Korea, this study conducted a preliminary field survey of four North American cities from where the idea of community gardening originates. A total of 166 community gardens in Seattle, New York, Philadelphia and Vancouver were visited during this survey. Four community gardens from each city were selected for further analysis, with particular emphasis on spatial organization and social functions. The results showed that the community gardens in each city perform a diverse array of functions depending on location, type and societal needs. Community gardens in Seattle and Vancouver, which may be classified as 'uptown,' focused on their roles as fields of 'community participation.' Those in New York and Philadelphia, which are classified as 'downtown,' emphasized their function in 'urban beautification.' This study demonstrates that the community gardens in North America serve their roles as urban amenities and multi-functional public spaces for the entire local population. The implication of the results is that considerations for the social roles the community gardens serve and the spatial elements that allow the space to perform such functions are necessary for the further developments in the community garden research in Korea.

A Study on the Prediction of the Construction Cost in Planning Stage of Local Housing Union Project (지역주택조합사업 기획단계의 공사비 예측에 관한 연구)

  • Lee, Jin-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.653-659
    • /
    • 2018
  • The accurate prediction of construction cost is a key factor in a project's success. However, it is hard to predict the construction costs in the planning stages rapidly and precisely when drawings, specifications, construction cost calculation statements are incomplete, among other factors. Accurate construction-cost prediction in the planning stage of a project is also important for project feasibility studies and successful completion. Therefore, various techniques have been applied to accurately predict construction costs at an early stage when project information is limited. There are many factors that affect the construction cost prediction. This paper presents a construction-cost prediction method as multiple regression model with seven construction factors as independent variables. The method was used to predict the construction cost of a local housing union project, and the error rate was 4.87%. It is not possible to compare the cost of the project at the planning stage of the local housing union project, but it has high prediction accuracy compared to the unit price of an existing unit area. It is likely to be applied in construction-cost calculation work and to contribute to the establishment of the budget for the local housing union project.

A Development of Work Breakdown Structure and Link to Standard Estimation System for 3D Printing Building (건축물 3D 프린팅 공종분류체계 도출 및 표준품셈 연계방안 제시)

  • Ju, Ki-Beom;Seo, Myoung-Bae;Park, Hyung-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.702-708
    • /
    • 2018
  • 3D printing technology is attracting increasing attention as a key technology of the fourth industrial revolution that can change the production paradigm of existing industries. The introduction of construction 3D printing technology has been slower than other industries because of the characteristics of the construction field. On the other hand construction automation using 3D printing is required to reduce the production population, as well as improve productivity and safety. In this study, a construction 3D printing work breakdown structure and link method to a standard estimation system were developed as a preliminary preparation for introducing 3D printing to construction. Based on expert consultation on construction and 3D printing, a hypothetical scenario was developed based on existing construction 3D printing technology. According to the scenario, 16 kinds of works required for 3D printing construction work were derived. The existing work breakdown structure and standard estimation system were analyzed, and the 3D printing work was linked. 3D printing works that were the same as the existing breakdown structure were found, and non-existent works were added to the similar breakdown structure. These results are expected to be helpful for future 3D printing construction management and cost estimation. The actual standard estimation system through 3D printing work will need to be calculated.

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

Bolt-joint Structural Health Monitoring Technique Using Transfer Impedance (전달 임피던스를 이용한 볼트 접합부 구조 건전성 모니터링 기법)

  • Lee, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.387-392
    • /
    • 2019
  • A technique was researched to detect bolt looseness using a transfer impedance technique (the dual piezoelectric material technique) for monitoring the structural health of a bolt joint. In order to use the single piezoelectric material technique, an expensive impedance analyzer should be used. However, in the transfer impedance technique, low-cost fault detection can be performed using a general function generator and a digital multimeter. A steel plate frame test specimen composed of bolt joints was fabricated, and the tightening torques of the bolts were loosened step by step. By using the transfer impedance method, the damage index was obtained. It was found that the presence of faults could be reasonably estimated using the damage index, which increased with the degree of bolt looseness. An experiment was performed on the same specimen using the single piezoelectric material technique, and the results showed a similar tendency. It could be possible to estimate the damage of a bolt joint at low cost by eliminating the expensive impedance analyzer. This method could be used effectively for structural health monitoring after carrying out a study to estimate the fault location and severity.

Analysis of the Relationship between Human Risk Factors and Evacuation Behavior for Tunnel Safety (터널안전에 대한 인적위험 요소와 대피행동 간의 관계분석)

  • Baek, Chung-Hyun;Park, Sea-Man;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.535-546
    • /
    • 2019
  • The purpose of this research was to analyze the relationship between human risk factors and evacuation behavior stages for tunnel safety. Therefore, we conducted a survey using a structured questionnaire on the relationship between safety facilities and safety behavior in order to derive an optimized interaction between the two. The research subjects were 141 tunnel users who understand the tunnel environment. The survey period was from June 24, 2018, to September 28, 2018. As data analysis methods, we employed a frequency analysis, a multiple regression analysis, and an independent-sample t-test. In the analysis of the correlation between the human risk factors and the major variables of evacuation behavior, the evacuation phases 1, 2, and 3 were all correlated with acceleration and delay, and the human risk factors were partially correlated. In the multiple regression analysis, the will to comply with laws (${\beta}=0.188$, p=0.034) and information recognition within the tunnel (${\beta}=0.220$, p=0.009) were factors that influence the relationship between human risk factors and evacuation behavior, indicating 12% explanatory power of the impact of human risk factors for the acceleration of evacuation behavior 3. The important variables between human risk factors and evacuation behavior were compliance with laws and information recognition in tunnels. Hence, it is necessary to study the elements that interact with the environment in the tunnel.

A Study on Survey Research Design Quality Indicators for the Educational Building - Focused on Teachers, School Personnel and Education Office Supervisor - (학교시설 디자인 품질지표에 대한 설문 연구 - 교사, 학교직원, 교육청담당자를 중심으로 -)

  • Cho, Kyung-Sik;Belyalova, Aigerim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.5
    • /
    • pp.3-12
    • /
    • 2018
  • The purpose of this study is to examine the degree of appropriateness of using design quality indicators for the educational building, and complements for design quality indicators. For doing this, each items of the Korean educational building design indicator was validated by teachers, school staff and an education officer. First, School Personnel and Teachers considered indicators for the classroom designed for general subjects as being valid. However, in terms of indicators for the outside space, they thought of them as not being valid. In particular, it seemed that school staff would have a passive attitude toward the open of the school facility for the local society. It is judged that there happens an adverse effect caused by the open of the school facility for the local society in the educational environment of the school. Second, Education Office Supervisors thought that eco-friendly indicators, LED lighting, an outer wall, and widows and doors had a high validity. On the contrary, he viewed the validity of a rainwater retention basin as being low, which was likely because he rarely had expertise on the construction. When it comes to the indicator of technology capability, ultrahigh-speed information network was seen as being valid, and the indicator of economic feasibility had high validity on maintenance and durability. Third, compared to groups of Teachers and School Personnel, the group of education officers presented high validity of indicators. Validity of indicators might be differently showed because different items on indicators were measured. However, it is speculated that Education Office Supervisors mostly acknowledged the validity of indicators. Fourth, a majority of Teachers, School staff, and Education Office Supervisors were favor of the system of the evaluation accreditation for school facilities since it played a guide role in improving the quality of school. In order to settle the system of the evaluation accreditation for school facilities, it is most important that institutions in the local society which are publicly reliable should participate in the phase of designing the system of the evaluation accreditation for school facilities. In sum, overall respondents agreed with the system of the evaluation accreditation for school facilities but were aware that reliable organizations in public would need to take part in planning the system of the evaluation accreditation for school facilities from the beginning.

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

Low-cost Impedance Technique for Structural Health Monitoring (임피던스 기반 저비용 구조물 건전성 모니터링 기법)

  • Lee, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.265-271
    • /
    • 2018
  • This paper presents a method for detecting damage to a structure at low cost using its impedance. The impedance technique is a typical method to detect local damage for structural health monitoring. This is a common technique for estimating damage by monitoring the electro-mechanical admittance signal of the structure. To apply this technique, an expensive impedance analyzer is generally used. On the other hand, it is necessary to develop a low-cost variant to effectively disseminate the technique. In this study, a method based on the transfer impedance using a function generator and digital multimeter, which are generally used in the laboratory instead of an impedance analyzer, was developed. That is, this technique estimates the damage by comparing the damage index using the amplitude ratio of the output voltage measured in the healthy and damaged state. A transfer impedance test was carried out on a steel specimen. By comparing the damage index, the presence of damage could be assessed reasonably. This study is a basic investigation of an impedance-based low-cost damage detection method that can be used effectively for structural health monitoring if supplemented with future research to estimate the damage location and severity.

Comparison of Two Methods for Analyzing Stress-Strain Behavior of Soil Beam (지반보의 응력-변형률 거동에 대한 해석법 비교)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.294-302
    • /
    • 2018
  • To analyze the behavior of a soil beam under pore water pressure, the results of analytical solutions and finite element analysis (FEM) were compared quantitatively. In contrast to the results of the analytical solution, the horizontal stress obtained from the FEM did not show a symmetrical distribution. On the other hand, the horizontal stress became closer to symmetrical distribution as the number of elements of the soil beam were increased. A comparison of the horizontal stresses from the analytic solution with those obtained from Gaussian points of FEM showed that the magnitude of the tensile stress from the FEM using 3 elements was 6% of the maximum value of the analytical solution and the compressive stress from the FEM using the same elements was 37% of the maximum value of the analytical solution. The magnitude of the tensile stress from the FEM using 6 elements was 61% of the maximum value of the analytical solution and the magnitude of the compressive stress from the FEM using the elements was 83% of the maximum value of the analytical solution. Vertical stresses, which were obtained from the analytical solution, showed a continuous distribution with the depth of the soil beam, whereas the vertical stresses from the FEM showed a discrete distribution corresponding to each element. The results also showed that the average value of the vertical stresses of each element was close to that of the pore water pressure. A comparison of the vertical displacements computed at the near vertical center line of the soil beam from the FEM with those of the analytical solution showed that the magnitude of the vertical displacement from FEM using 3 elements was 35% of the value of the analytical solution and the magnitude of the vertical displacement from FEM using 6 elements was 57% of the value of the analytical solution.