Kim, Ki-Dong;Ha, Yu-Shin;Lee, Ki-Myung;Park, Dae-Heum;Kwon, Soon-Gu;Park, Jong-Min;Chung, Sung-Won
Journal of Bio-Environment Control
/
v.19
no.4
/
pp.183-188
/
2010
It is necessary to develop an efficient and affordable cooling technology and apply the practical system to rural farmhouse, control to adequate growth environment by adjusting temperature of root zone. A study on managing medium temperature of the hydroponics for strawberry cultivation was conducted and feasible evaporative cooling system for the media cooling were as follows: Characteristics of temperature drop were investigated for the evaporative cooling devices using microporous film duct, felt mulching on media surface, and water permeable sheet in culture tank. The evaporative device with water permeable sheet in culture tank was the most efficient and economic on media cooling system.
Proceedings of the Korea Water Resources Association Conference
/
2017.05a
/
pp.237-240
/
2017
지구온난화로 인해 세계 곳곳에서 기온상승이 관측되고 있으며, 이는 전지구적 기후시스템의 변화를 보여주는 대표적인 예이다. 온도를 비롯한 강수량, 풍속, 증발량 등의 기상학적, 수문학적 인자들이 각각 서로에게 영향을 주고 받으며 복잡하게 변화할 것이고, 그 변화폭도 점점 커질 것이다. 증발에 영향을 미치는 인자들은 크게 세 가지로 나뉘는데, 태양복사에너지, 온도, 바람, 기압, 습도와 같은 기상학적인자, 증발표면의 특성인자 그리고 수질인자로 분류할 수 있다. 증발에 영향을 주는 인자들은 예전부터 알려져 있지만 이들 간의 복잡한 상호작용에 대해 정확히 이해하기는 쉽지 않다. 본 연구에서는 댐유역의 증발량에 영향을 미치는 기상인자 파악을 위해 2008부터 2016년까지 관측된 낙동강수계 내 안동댐과 남강댐의 기상자료(기온, 강수량, 풍속, 상대습도, 기압, 일사량, 일조시간, 전운량)를 이용한 변화를 분석하였으며, 다변량 통계기법인요인분석을 통해 증발량과 상관성이 높은 인자들을 분류하였다. 안동댐과 남강댐 공통적으로 증발량과 기온, 기압이 같은 요인으로 분류되고 높은 상관성을 보였으며, 강수량, 일조시간, 일사량, 전운량이 같은 요인으로 분류되었다. 국내의 증발량 측정지점에 대한 추가적인 분석과 영향인자를 이용한 다변량회귀식과 인공신경망 통해 증발량 미측정 지점의 증발량 산정이 가능할 것으로 판단된다.
Kim, Eun-Do;Cha, Su-Yeong;Mun, Il-Gwon;Hwang, Do-Won;Jo, Seong-Jin;Kim, Chung-Gi;Kim, Jong-Pil;Yun, Jae-Ho
Proceedings of the Korean Vacuum Society Conference
/
2014.02a
/
pp.443-443
/
2014
CIS 박막을 제조하기 위한 방법으로 셀렌화(selenization)방식, MOCVD방식, 동시진공증발(co-evaporation)방식, 전착(electrodeposition)방식 등이 있으나, 이러한 방식을 이용하여 CuInSe2 박막을 제조하는 경우 어떤 방법으로든 다원화합물의 조성 및 결정성을 조절하기가 매우 어려운 단점이 있었다. 기판의 온도를 일정 온도로 유지하도록 하고, 증발원을 가열하여 이에 내포된 물질(이원화합물 또는 단일원소)을 증발시켜 기판에 증착이 이루어지도록 하거나, 기판의 온도를 승온시키고 구리 이원화합물을 내포한 증발원을 가열해 물질을 증발시켜 기판에 증착이 이루어지도록 하는 방법으로 기판에 박막이 형성되도록 한다. 기판의 대면적화로 인해 균일한 박막의 형성이 어려워지고 있으며, 이중 15% 이상의 고효율을 보인 방법은 3-stage process를 이용한 동시진공증발방식으로, Cu, In, Ga, Se 등의 각 원소를 동시에 진공 증발시키면서 조성을 조절하여 태양전지에 적절한 전기적, 광학적 특성을 가지는 Cu(In,Ga)Se2 (CIGS)박막을 증착시키는 방법이다. 일반적으로, 실험실에서 연구되고 있는 장비의 구조는 증발원이 아래에 장착되어서 상향 증착되는 방식이다. 본 연구에서 사용된 장비는 하향 증발원이 측면에 장착되어서 하향 증착되는 방식으로 구성하였다. 증착되는 면방향으로, 적외선온도계(pyrometer)가 설치된 시창(viewport)의 오염 등으로 인하여, 지속적인 공정이 이루어지기 힘든 점을 개선하여 증착기판의 후면에 적외선 온도계를 설치하여 기판의 온도변화를 감지하여 공정에 반영할 수 있도록 하였다. 본 연구에서는 하향식 진공 증발원, 기판후면 온도모니터링모듈 등을 개발 장착하여, CIGS 박막을 제조하였으며, 버퍼층은 moving 스퍼터링법으로 ZnS를 증착하였고, 투명전극층은 PLD(Pulsed Laser Deposition)를 이용하여 제조하였다. 가장 높은 광변환효율을 보인 Al/ZnO/CdS/Mo/SLG박막시료는 유효면적 $0.45cm^2$에 광변환효율 15.65 %, Jsc : $33.59mA/cm^2$, Voc : 0.64 V, FF : 73.09 %를 얻을 수 있었으며, CdS를 ZnS로 대체한 Al/ZnO/ZnS/Mo/SLG박막시료는 유효면적 $0.45cm^2$에 광변환효율 12.45 %, Jsc : $33.62mA/cm^2$, Voc : 0.59 V, FF : 62.35 %를 얻을 수 있었다.
Proceedings of the Korean Society for Agricultural Machinery Conference
/
2017.04a
/
pp.103-103
/
2017
증발기의 형태에 따라 수치적 해석을 진행하면서 최적의 효율을 나타낼 수 있는 증발기를 설계하는 것이 중요하다. 증발기의 수치적 해석은 EES 프로그램을 이용하여 진행되었으며, 계산의 검증은 자사의 제품의 성능과 비교하면서 검증하였다. 증발기의 수치적 해석의 구성은 지배방정식과 연속방정식을 이용하여, 냉매의 총괄열전달계수, 관내외벽의 열전도율, 공기의 총괄열전달계수를 이용하여 총괄열전달계수를 계산하였으며, 총괄열전달계수를 이용하여 증발기의 열량을 계산하였다. 증발기의 수치적 해석과 자사 제품 5개의 제품과 비교하였고, 평균적으로 약 10%의 오차율을 보였다. 신뢰성이 확보된 계산식을 이용하여 Fin의 간격, 단위 질량유량, 열 교환 코일 길이, 풍량의 조건을 각각 변동시켜 증발기 열량 비교를 하며 경향성을 고찰하였다. Fin의 간격을 1mm에서 20mm으로 0.5mm 간격으로 변화 시켰을 경우, 핀 간격이 좁으면 공기 유속이 빨라져 열 교환 효율이 낮아지며, 반대로 넓어지면 냉매 유량에 비해 공기 유량이 많기 때문에 열 교환 효율이 낮아진다. 열 교환 코일 길이를 500mm에서 2400mm으로 50mm 간격으로 변화 시켰을 경우, 열 교환 코일 길이가 길어질수록 배관의 마찰력과 냉매의 온도 상승으로 인하여 공기 온도와의 온도 차이가 줄어들어 열 교환 효율은 낮아진다. 풍량을 20cmm에서 400cmm으로 10cmm 간격으로 변화 시켰을 경우, 일정 풍량 이상 올라가면 공기 유속이 빨라져서 열량이 낮아지는 경향을 보인다. 질량유량을 3g/sec에서 174g/sec으로 4.5g/sec 간격으로 변화 시켰을 경우, 질량 유량에 따라 비례적으로 열량이 높아지는 경향을 보이다가 일정 질량 유량 이상에서는 공기 풍량에 비해 냉매 유량이 많기 때문에 반비례적으로 열량이 낮아진다. 이처럼 증발기의 설계는 Fin 간격, 열 교환 코일 길이, 풍량, 질량유량 등을 복합적으로 고려하여 증발기 설계를 해야 하며, 저장고의 크기, 부하, 사용목적에 따라 최적화된 증발기를 설계하여야 한다.
Proceedings of the Korea Water Resources Association Conference
/
2019.05a
/
pp.341-341
/
2019
물 순환과정의 구성요소 중 증발산(Evapotranspiration)은 수자원개발을 위한 계획의 수립과 수자원 시스템 운영적 측면에서 대단히 중요한 부분이다. 증발산량을 산정하기 위해서는 온도, 바람, 상대습도, 대기압, 수질 및 수표면의 성질과 형상 등을 산정하여야 하는데 이러한 기상자료들을 확보하기란 매우 어려운 실정이다. 본 연구에서는 기온자료만을 이용하여 기준증발산량을 산정할 수 있는 Hargreaves 공식의 경험적 매개변수 및 온도 매개변수를 수정하여 경안천유역의 기준증발산량을 산정하였다. 수정된 공식의 성능평가를 위해 현재 널리 사용되고 있는 Penman-Monteith 방법을 이용하여 산정된 기준증발산량을 정해로 가정하여 Root Mean Square Error와 Nash Sutcliffe Model Efficiency Coefficient분석을 수행하여 검증하였다. 또한 기온 및 Hargreaves 경험적 매개변수와의 상관관계를 이용한 회귀식에 대한 검증을 수행함으로써 본 연구에서 제안한 수정된 공식의 적용가능성을 확인하였으며, 향후 수자원 시스템 운영 측면에 도움이 될 것으로 판단된다.
Park, Noh-Hyun;Kim, Byeong-Sam;Park, Moo-Hyun;Han, Bong-Ho;Bae, Tae-Jin
Korean Journal of Food Science and Technology
/
v.22
no.4
/
pp.479-485
/
1990
For the automation of a evaporation process, computer based evaporation system was built and applied to acquisition of the process variables with an centrifugal thin film evaporator(Centri-Therm, CT-1B). Controls of the process conditions were performed by computer system for pressure, feeding rate, steam, evaporation temperature and flow rate of cooling water. The data acquisitions were also performed by computer system for the changes in the concentration and temperature readings for steam, evaporation and cooling water at the both inlet and outlet. The control and the acquisition variables were collected through the interface device and analyzed by programs using the PASCAL language. To control the feeding rate during the concentration process, inverter was used. The cooling water for the vapor condensation was controlled by the valve controller and should be supplied with the flow rate of 125 kg/h. The maximum vapor condensation rate was 41.7kg/h at the feeding rate of 125 kg/h.
Journal of the Korea Organic Resources Recycling Association
/
v.13
no.2
/
pp.74-84
/
2005
The objectives of this study was to investigate the improvement of thermal kinetics for disposal of sewage sludge using thermal wind drying. The operational parameters varied are the temperature of $130{\sim}170^{\circ}C$ and evaporation velocity WD. Important parameters effect on thermal kinetics for evaporation of water in sewage sludge studied include the drying time, water content of sewage sludge, solids amount of sewage sludge(TS%) by the varied temperature. The saturation point of water evaporation was observed at the drying time of 60 min in conditions of drying temperature $170^{\circ}C$ and drying time of 120 min by drying temperature $130^{\circ}C$ and WD=0.95 m/s. Operation at drying temperature of $170^{\circ}C$ led to higher rate of evaporation than those 130, $150^{\circ}C$ at WD=1.0 m/s and WD=1.0 m/s was higher than WD=0.5 m/s at drying temperature of $130^{\circ}C$.
Journal of Advanced Marine Engineering and Technology
/
v.36
no.4
/
pp.437-444
/
2012
This paper describes the experimental characteristics on cooling and heating performance of the coil deposition type heat pump using geothermal energy to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling degree, evaporation and condensation temperature in the coil deposition type heat pump using geothermal energy. The main results are summarized as follows : As the evaporation temperature and subcooling degree of the coil deposition type heat pump using geothermal energy increases, and the condensation temperature decreases, the COP of this system increases. The subcooling degree, evaporation and condensation temperature of the coil deposition type heat pump have an effect on cooling and heating COP of this heat pump. Therefore, it is a necessary to determine the optimum operation conditions for the highest COP of this heat pump presented in this study.
In this paper, cycle performance analysis of $NH_3-CO_2$(R717-R744) two-stage cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the ammonia(R717) high temperature cycle and the carbon dioxide low temperature cycle. The main results were summarized as follows : The COP of two-stage cascade refrigeration system increases with the increasing subcooling degree, but decreases with the increasing superheating degree. The COP of two-stage cascade refrigeration system decreases with the increasing condensing temperature, but increases with the increasing evaporating temperature. And the COP of two-stage cascade refrigeration system increases with increasing the compressor efficiency. Therefore, superheating and subcoolng degree, compressor efficiency, and evaporating and condensing temperature of $NH_3-CO_2$(R717-R744) two-stage cascade refrigeration system have an effect on the COP of this system.
Proceedings of the Korea Society for Energy Engineering kosee Conference
/
1995.11a
/
pp.115-115
/
1995
다중 효용관식 증발기는 보통의 증발기에서 응축하여 제거하는 증기를 다음 효용관의 가열원으로 재사용하는 것으로 그 자체로도 에너지 절감효과가 있는 것으로 알려져 있다[1,2,4]. 기계식증기 재압축 증발기는 보통 증발기에서 응축시켜 제거하는 발생 증기를 압축하여 고온의 증기로 만든 다음 가열원으로 재이용하는 장치로 이에 대한 효용은 문헌에 잘 나타나있다[3,4]. 여기서는 다중효용관과 증기 재압축기를 조합한 증발기 중에서 Forward feed 방식의 다중효응관에 증기 재압축기를 부착한 경우에 대하여 타당한 물질수지, 열수지, 전열 식, 상평형식을 소개하였다. 또한 압축기의 용량을 결정하기 위한 단열압축공정의 지배방정 식을 소개하였다. 원료의 조건, 효용관의 수 및 총전열온도차가 주어지면 상기의 지배방정식의 해를 구할 수 있는데. 본연구에서는 Gauss-Seidel의 연속치환법을 이용하였다. 이와 같이 지배방적식의 해를 구하면 효용관의 면적, 압축펌프의 용량, 각효용관 입출구의 조건 등이 계산된다. 다중효용관 기계식 증기 재압축 증발장치의 최적화를 위하여는 효용관의 전열면적당 가격과 압축펌프의 용량당 가격 그리고 펌프를 운전하는데 필요한 전력의 요금 등의 자료가 요구된다. 총전열온도차에 따른 운전비와 시설비의 합이 최소가 되는 점이 최적 총전열온도차가 되는데 이 점을 구할 때에는 수치적으로 안정한 이분법을 이용하였다. Borland C++를 이용하여 프로그램하였으며 윈도우즈 환경에서 수행되게 하였다. 사용자 쉽게 이용할 수 있게 하기 위하여 각종 필요한 데이터를 입력할 수 있는 Edit box가 화면에 나타나게 하였다. 또한 입력된 데이터를 저장하거나 불려올 수 있는 메뉴, 입력된 데이타를 이용하여 효용관의 면적과 압축기의 용량을 계산하거나 효용관의 수가 주어졌을 때 총전열온도차를 최적화하는 것을 선택할 수 있는 메뉴 그리고 계산 결과를 파일로 혹은 프린트로 출력할 것을 선택할 수 있는 메뉴가 있다. 사용자는 해당되는 데이타를 입력한후 마우스로 원하는 작업의 메뉴를 선택하면 된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.