• Title/Summary/Keyword: 증발냉각시스템

Search Result 72, Processing Time 0.027 seconds

Adaptability of an Evaporative Cooling System to the Weather Conditions in Korea (지역별 기상조건에 따른 증발냉각시스템의 적용성)

  • 남상운;김문기
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.11-15
    • /
    • 1998
  • 증발냉각시스템의 원리는 물이 수증기로 상태변화할 때 필요한 기화열을 주변으로부터 공급받으면서 공기의 온도가 감소하는 것이다. 이것은 덥고 건조한 지역에서는 매우 효과적이지만 상대습도가 높은 지역에서는 냉방효과가 낮다. 따라서 국내의 모든지역에 증발냉각시스템의 적용이 적합한지는 의문이다. (중략)

  • PDF

Adaptability of Evaporative Cooling System for Greenhouses to the Weather Conditions of Korea (증발냉각시스템의 온실냉방 적용성 평가)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.7 no.4
    • /
    • pp.283-289
    • /
    • 1998
  • The adaptability of an evaporative cooling system to hot summer climate in greenhouses was comprehensively judged by fuzzy theory, based on the 20 years(1975~1994) weather data of nine representative regions in Korea. As uses the evaporative cooling system for greenhouses during summer in Korea, the inside air temperature of most regions except the southwest coastal areas, the south coastal areas, and Cheju island can be basically controlled below 32.5$^{\circ}C$, and ventilating air can be cooled 5$^{\circ}C$ and more. The analyzed results in this paper are on the basis of good ventilation system. When the evaporative cooling system is applied, the ventilation system which has good air flow organization is needed. Although the summer climate in Korea is high temperature and humidity, evaporative cooling systems are suitable for farm buildings in most regions. This facts better meet the needs of cooling for greenhouse in summer and provides a scientific basis for spreading the evaporative cooling system It is proposed that the further research is needed about the application of evaporative cooling system to greenhouses.

  • PDF

The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate (환기회수에 따른 포그냉방시스템의 냉방효과)

  • 김기성;김문기;권혁진
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.84-88
    • /
    • 2000
  • 첨단유리온실의 건설이 증가하면서 여름철 온실내 환경의 적정화를 위하여 증발냉각시스템의 도입이 증가하고 있으며, 대표적인 증발냉각시스템은 패드-팬 시스템과 포그시스템 등이 있다. 포그시스템은 냉방효율이 높고 다른 시스템과 비교하여 저비용이며 온실내부공간의 활용면에서 우수한 장점이 있어 그 보급이 증가하고 있다. (중략)

  • PDF

Application of Heat Balance Model for Determination of Facilities Capacity to Overcome High Temperature in Greenhouses (온실의 고온극복설비 용량 결정을 위한 열평형 모델의 적용)

  • 남상운
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.27-30
    • /
    • 2000
  • 여름철 고온기에 시설 이용율을 높이고 안정적인 생산을 하기 위하여는 적극적인 차광 환기시스템과 증발냉각시스템을 도입하는 것이 필요하다. 이러한 시스템을 도입하기 위하여는 적정 설비용량의 결정이 중요하며, 이는 지역별 외부의 설계 기상자료로부터 구할 수 있다. 차광환기시스템에서 차광율은 작물의 종류에 따라서 결정되어야 하며 따라서, 기븐적으로 결정해야될 설계 인자는 목표온도를 달성하기 위한 필요환기율과 증발냉각시스템 의 분무수량이다. (중략)

  • PDF

Dehumidification and Evaporative Cooling Efficiency by Water Pipes in Greenhouse (냉수파이프에 의한 온실의 제습 및 증발냉각효율)

  • 김문기;남상운;윤남규
    • Journal of Bio-Environment Control
    • /
    • v.7 no.3
    • /
    • pp.237-245
    • /
    • 1998
  • Greenhouse crop production under critical summer climate In Korea has considerable difficulties because of high temperature and relative humidity. In this study, some water pipes were tested as a means of the dehumidification and increment of evaporative cooling efficiency. As a result of heat transfer characteristic analysis, overall heat transfer coefficient of copper pipe was larger than steel pipe, and estimated values were smaller than measured values. The condensed quantities of vapor were not significantly different between copper pipe and steel pipe, however dehumidifying effect by the water pipes was significantly large. It was estimated based on the results that the evaporative cooling system by the water pipe will be able to increase the evaporative cooling efficiency of about 48%, and decrease the temperature of about 1.3$^{\circ}C$.

  • PDF

Field Investigation and Analysis of Greenhouse with Evaporative Cooling Systems (증발냉각시스템 설치온실의 실태 조사 및 분석)

  • 김기성;김문기;유인호;원종선
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.213-216
    • /
    • 1999
  • 우리나라의 기후 특성상 여름철에는 온실내 기온과 지온이 과다하게 상승하여 정상적인 작물 생육을 기대하기 어렵다. 이러한 고온현상을 극복하기 위해 우리나라 시설원예 농가에서는 소극적이면서 비용이 적게 드는 흑색 차광망이나 자연환기를 주로 이용하고 있으며 냉방 효과가 적어 문제가 되고 있다. 근래 온실 냉방에 대한 중요성을 인식하고 증발냉각시스템을 도입하는 시설원예농가가 증가하고 있으나 기술적인 측면에서 아직 많은 문제점들이 남아있는 실정이다. (중략)

  • PDF

Development of Temperature Control Technology of Root Zone using Evaporative Cooling Methods in the Strawberry Hydroponics (증발 냉각방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발)

  • Kim, Ki-Dong;Ha, Yu-Shin;Lee, Ki-Myung;Park, Dae-Heum;Kwon, Soon-Gu;Park, Jong-Min;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.183-188
    • /
    • 2010
  • It is necessary to develop an efficient and affordable cooling technology and apply the practical system to rural farmhouse, control to adequate growth environment by adjusting temperature of root zone. A study on managing medium temperature of the hydroponics for strawberry cultivation was conducted and feasible evaporative cooling system for the media cooling were as follows: Characteristics of temperature drop were investigated for the evaporative cooling devices using microporous film duct, felt mulching on media surface, and water permeable sheet in culture tank. The evaporative device with water permeable sheet in culture tank was the most efficient and economic on media cooling system.

Performance Analysis of R744(Carbon Dioxide) for Transcritical Refrigeration System (R744용 초임계 냉동사이클의 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.32-38
    • /
    • 2009
  • In this paper, cycle performance analysis for cooling capacity, compression work and COP of R744($CO_2$) transcritical vapor compression refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : The cooling capacity of R744 increases with superheating degree, but decreases with the increasing evaporating temperature and outlet temperature of gas cooler. The compression work increases with superheating degree and cooling pressure of R744, but decreases with the increasing evaporating temperature. And, The COP increases with outlet temperature and evaporating temperature of R744 gas cooler, but decreases with the increasing superheating degree. Therefore, superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

Analytical Study of heat Transfer in Evaporative Cooling of a Porous Layer (다공층의 증발냉각 열전달에 관한 해석적 연구)

  • 김홍제;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.104-111
    • /
    • 1992
  • In this study, the heat transfer characteristics of the evaporative transpiration cooled system is analytically investigated considering the occurrence of the two-phase evaporation zone. Under the condition of the external heat input, analytical solutions of the three regions (i.e., vapor, liquid and two-phase evaporation zone) are respectively obtained using the matching conditions for the steady-state problem where properties are constant. As results, the length of the evaporation zone increases with increasing heat input and with decreasing mass flow rate. It also increases with increasing particle size, system porosity, thermal conductivity of material, inlet temperature and latent heat of coolant. The position of the lower interface of the evaporation zone have a lot of efforts on the evaporation zone length, the position of the upper interface penetrates deeper into the porous layer with lower thermal conductivity of porous material, higher system porosity and larger particle size.

Development Cooling and Dehumidifying System for Greenhouse using Hygroscopic properties of Lithium Bromide Solution (리튬브로마이드 수용액의 흡습성질을 이용한 온실 냉방 및 제습 시스템 개발)

  • Cho, La Hoon;Oh, Kwang Cheol;Lee, Sang Yeol;Joo, Sang Yeon;Park, Sun Yong;Lee, Seo Hyeon;Jeong, In Seon;Lee, Chung Geon;Kim, Dae Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.79-79
    • /
    • 2017
  • 국내 여름철의 고온다습한 기후환경으로 인하여 온실 내부의 냉방 및 제습이 필수적인데, 온실 냉방 방식 중 증발냉각 시스템이 가장 효율이 높다고 알려져 있다. 하지만 증발냉각 시스템은 건조한 기후 지역에서 발달한 방식으로, 작물의 증산작용으로 인한 온실 내부 습도 상승에 따른 문제점이 발생되어 다습한 여름철 국내 기후에는 반드시 냉각과 제습이 동시에 필요하다. 따라서 증발냉각 방식 중 Fan and Pad 방식과 리튬브로마이드 수용액을 이용한 온실 냉방 및 제습을 위한 복합시스템에 관한 연구가 진행중이다. 현재 리튬브로마이드 수용액 제습 시 발생되는 발열량과 수용액의 무게변화와 같은 수용액의 흡습성질 대한 정확한 지표가 나타나 있지 않다. 이에 연구를 진행하기에 앞서 리튬브로마이드 흡습성질에 관한 데이터 자료가 필요하다고 판단되어 기초실험을 진행하였고, 본 연구에서는 Pilot Scale의 재생 순환시스템을 통해 리튬브로마이드 수용액의 흡습성질을 이용한 재사용 방안을 제시하였고, 시스템 내에서 외부투입공기와 작동유체의 흡습성질에 의한 반응 전후 온도변화 예측 모델을 수립하였다. 따라서 본 연구를 통해 리튬브로마이드 수용액의 흡습성질을 분석하고, 이를 이 용한 재생 순환 시스템에 관한 연구를 진행할 예정이다.

  • PDF