• Title/Summary/Keyword: 증기이젝터

Search Result 25, Processing Time 0.021 seconds

An Experimental Study of the Subsonic/Supersonic Steam Ejectors (아음속/초음속 증기 이젝터에 관한 실험적 연구)

  • Kim, Heuy-Dong;Choi, Bo-Gyu;Lee, Jun-Hee
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.479-484
    • /
    • 2000
  • For the purpose of a cost effective design of practical subsonic/supersonic ejector systems, an experiment was carried out using a superheated steam as a primary driving flow. The superheated steam jet was produced by several different kinds of subsonic and supersonic nozzles. The secondary flow of atmospheric air inside a plenum chamber was drawn into the primary steam jet. The vacuum performance of the plenum chamber was investigated for a wide range of the ejector operation pressure ratio. The result showed that the static pressure of the mixed flow at the ejector throat is only a function of the ejector operation pressure ratio, regardless of the primary nezzle type employed.

  • PDF

The performance comparison of vapor-vapor ejector OTEC system using wet refrigerants (습냉매를 적용한 증기-증기 이젝터용 OTEC 시스템의 성능비교)

  • Yoon, Jung-In;Son, Chang-Hyo;Kim, Young-Bok;Ye, Byung Hyo;Ha, Su-Jeong;Lee, Ho-Saeng;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.51-56
    • /
    • 2014
  • In this paper, OTEC(Ocean Thermal Energy Conversion) system with vapor-vapor ejector is newly proposed. And 6 wet refrigerants are applied into the proposed OTEC system for performance comparison. The results of comparison performance are as follows. In the view of system efficiency, R32/R744(90:10) has the highest efficiency among the 6 refrigerants. In case of evaporation capacity, pump work and mass flow rate of working fluid, R744, R717 and R717 is lowest value, respectively. As this results, the vapor-vapor ejector is able to increase the efficiency of system. And It is necessary to select the optimized working fluid considering environmental and economic factors.

The numerical analysis of performance of OTEC system with vapor-vapor ejector (증기-증기 이젝터를 적용한 OTEC 시스템 성능의 수치적 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Ye, Byung-Hyo;Ha, Soo Jeong;Choi, In-Soo;Lee, Ho-Saeng;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.45-50
    • /
    • 2014
  • In this paper, the Ocean Thermal Energy Conversion(OTEC) with vapor-vapor ejector is proposed newly. At this OTEC system, a vapor-vapor ejector is installed at inlet of condenser. The vapor-vapor ejector plays a very important role in increasing of the production work of low-stage turbine throughout the decrement of outlet pressure of ejector. The performance analysis is conducted for optimizing the system with HYSYS program. The procedure of performance analysis consists of outlet pressure of high turbine, the mass ratio of working fluid at separator, total working fluid rate, and nozzle diameters of vapor-vapor ejector. The main results is summarized as follows. The nozzle diameter is most important thing in this study. When each nozzle diameter of vapor-vapor ejector is 10 mm, the efficiency of OTEC system with vapor-vapor ejector shows the highest value. So it is necessary to set the optimized nozzle diameters of vapor-vapor ejector for achieving the high efficiency OTEC power system.

Study of the Operation Characteristics of the Supersonic Steam Ejector System (초음속 증기 이젝터 시스템의 작동 특성에 관한 연구)

  • Kim, H.D.;Lee, J.H.;Woo, S.H.;Choi, B.G.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.329-334
    • /
    • 2001
  • In order to investigate the operating characteristics of a supersonic steam ejector, the axisymmetric, compressible, Reynolds-averaged, Navier-Stokes computations are performed using a finite volume method. The secondary and back pressures of the ejector system with a second throat are changed to investigate their effects on the suction mass flow. Three operation modes of the steam ejector system, the critical mode, subcritical mode and back flow mode, are discussed to predict the critical suction mass flow. The present computations are validated with some experimental results. The secondary and back pressures of the supersonic steam ejector significantly affect the critical suction mass flow. The present computations predict the experimented critical mass flow with fairly good accuracy. A good correlation is obtained for the critical suction mass flow. The present results show that provided the primary nozzle configuration and secondary pressure are known, we can predict the critical mass flow with good accuracy.

  • PDF

Numerical Analysis for the Internal Flow of Thermal Vapor Compressor with real gas equation of state (실제기체 상태방정식을 적용한 열압축기 내부유동에 대한 수치해석)

  • Kang, Wee-Kwan;Choi, Du-Yeol;Shin, Jee-Young;Kim, Moo-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.216-223
    • /
    • 2011
  • TVC is a kind of ejector which entrains low pressure working fluid by using the high pressure working fluid. While most papers relating with ejectors treat the working fluid as an ideal gas for convenience, the fluid doesn't behave as the ideal gas when phase change occurs. In this study, numerical analysis is conducted by applying Redlich-Kwong equation of state instead of ideal gas equation of state. Two turbulent models are compared for the better prediction and SST k-${\omega}$ model is preferred rather than realizable k-${\epsilon}$ model by comparison. Energy loss at the diffuser inlet and throat using the real gas equation of state is relatively greater than that using ideal gas law. For the real gas case, pressure increase due to shock train at the diffuser outlet is relatively smaller than the ideal gas case, but both cases have the same pressure increase due to a pseudo shock.

Investigation of MVR and TVR in Chemical Processes by Using Waste Steam (화학공정 내 폐증기를 활용한 MVR 및 TVR 연구)

  • Lee, Chang Min;Lim, Jeong Yeol;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.201-206
    • /
    • 2015
  • The MVR was theoretically modeled by performing the polytropic process, and the polytropic coefficient was estimated by using the performance curve provided by the manufacturers. The TVR was investigated by applying the conservation equations to the movement of fluids inside the TVR. The size of the nozzle and diffuser was determined. Theoretical MVR and TVR modeling was verified by comparing the results of the model with the available design data. Besides, the effects of multi-staging of the MVR on power consumption, and the effects of suction and primary pressure on the sizing of TVR were investigated.

A Study on the Vacuum System for High Efficiency Marine Steam Turbine System (대형 터어빈계통의 고효율 배압시스템 개발에 관한 연구(I))

  • 김경근;윤석환;김용모;김종헌;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.13-24
    • /
    • 1994
  • The demand of clean energy, like liquefied gas(LNG), increase suddenly because it generates few polluting substances when burned and from the point of view with caloric value it generates ralatively less $CO_2$ gas than the other energy sources. LNG transpotion method of our country is marine transportion by ships because the LNG producing district is far away from Korea. Main engines for most LNG ships are steam turbines, and the efficiency of steam turbine is influenced by the degree of vacuum of main steam condenser. This paper introduce the design method of the vacuum system for high efficiency marine steam turbine. Especially, it is developed the CAD program for the large steam condenser and steam ejector. Also, it is designed the pilot plant including high pressure boiler for the performance test and maked a part of this plant.

  • PDF

A Study on the Comparison of Design Conditions between Booster Ejector and Air Ejector in the Steam-Jet Water-Vapour Refrigeration Cycle (증기분사냉동계의 부우스터 이젝터와 에어 이젝터의 설계조건비교에 관한 연구)

  • Lee, Chang-Sik
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.2
    • /
    • pp.73-79
    • /
    • 1978
  • This paper presents the experimental study on the design conditions of pressure between booster ejector and air ejector in the steam-jet water-vapour refrigeration system. In this experiment, the motive steam of booster ejector and ai. ejector was dry saturated from 6 ata to 8 ata and flash chamber pressure were about $10\∼540mmHg$ higher than mixing section in booster ejector. The investigation of air on the pressure of booster ejector was performed by changing the condenser pressure. The experimental results show that flash chamber vacuum and condenser pressure of steam-jet refrigeration cycle increased in accordance with the increase of motive steam Pressure. Among the several nozzle sires tested, No.4 nozzle were best in term of evaporator vacuum under the constant operating conditions of air ejector in condenser.

  • PDF

A Study on the Performance of Steam Ejector by Variation of Steam Pressure (증기압력 변화에 따른 증기 이젝터의 성능에 관한 연구)

  • Jun You-Sin;Shin You-Sik;Jin Zhen Hua;Jeong Hyo-Min;Chung Han-Shik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.761-766
    • /
    • 2006
  • This paper describes a study on the performance of steam ejector by variation of steam pressure. Water temperature is especially important for good qualify of fish in an inland aquafam. In summer season, the water temperature increases above $25^{\circ}C$, but for good quality breeding or fish is the maintenance of optimum aquafam temperature by about $20^{\circ}C$. Therefore it is needed to drop the water temperature to provide suitable conditions of fish growth. There are many kinds of cooling system, in this study using steam ejector. After cooling the water in vacuum tank with the steam ejector then circulate this water to inland aquafam. In this way to minimizes fish stress that it is caused by water temperature. The objective of research confirms the difference of the case which there is no water in the vacuum tank and has water in the vacuum tank. The purpose of this paper is to examine the effects on the performance of steam ejector by variation of steam pressure.

  • PDF

An Experimental Study on the Performance of a Liquid-Vapor Ejector with Water (액체-증기 이젝터의 성능에 관한 실험적 연구)

  • 박대웅;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.345-353
    • /
    • 2000
  • In this study, the performance of five ejectors has been investigated with working fluids of water and water vapor. The diameters of nozzle and mixing tube of five ejectors were 1 and 1.5(ejector A), 1 and 2(ejector B), 1 and 2.5(ejector C), 1 and 3(ejector D), 2 and 4(ejector E) in millimeters. The length of the mixing tube was 8-10 times of its diameter. For each ejector, the ratio of mass flow rate of ejected water to that of entrained water vapor, $\mu$, was evaluated in terms of evaporator pressure, mass flow rate of ejected water, and water temperature. It was found that the performance of an ejector was not stable when the ratio of diameters was too small or too large(ejector A and D) and $\mu$ was almost the same for two ejectors with the same diameter ratio(ejector B and E). It was also found that $\mu$ increased almost linearly with an increase of evaporator pressure and the ratio $\mu$ increased as water temperature decreased. As expected, $\mu$ converged to zero as the water temperature approached the evaporator temperature. Finally, a non-dimensional correlation has been developed to predict$\mu$ terms of evaporator pressure and saturation pressure of ejected water.

  • PDF