• Title/Summary/Keyword: 증기관

Search Result 325, Processing Time 0.023 seconds

Characteristics Testing of the ECT Bobbin Probe for Steam Generator Tube Inspection of Nuclear Power Plant (원전 증기발생기 전열관 와전류검사 보빈탐촉자의 특성 시험)

  • Nam, Min-Woo;Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.386-395
    • /
    • 2010
  • The steam generator management program(SGMP) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. The first way is to qualify the equipment or the probe by using the flaw mechanism and method of the pulled tubes from the heat exchangers or the artificial flawed tubes. The second way is to verify the equivalency with the characteristics of the qualified equipment or probe. In this case, the qualified equipment or probe may be modified to substitute or replace instruments or probes without re-qualification provided that the range of essential variables defined in the examination technique specification sheet are met. This study is to describe the result of the comparative performance evaluation of bobbin coil eddy current probes manufactured by KEPCO Research Institute and probes manufactured by a foreign manufacturer. As a result of this study, although there were minor differences between the two kinds of probes, it was evaluated that the two kinds of probes were almost identical in the significant performance characteristics described in the KEPCO Research Institute guideline.

Analysis of Pressure Drop and Heat Loss in Liquid Sodium Circulation Wick of AMTEC (AMTEC의 소디움액체 순환윅에서 압력손실 및 열손실해석)

  • Lee, Ki-Woo;Lee, Wook-Hyun;Rhi, Seok-Ho;Lee, Kye-Bock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.953-960
    • /
    • 2012
  • An AMTEC (alkali metal thermal electric converter) is a device that is used for the direct conversion of heat to electricity. Sodium is used as the working fluid, and its circulation is driven by a capillary wick. The wicks used for circulation include an evaporator wick, artery wick, and condenser wick, and each wick has a pressure drop because of the circulation of liquid and vapor. For the circulation of sodium, the capillary pressure of the evaporator wick must be greater than the total pressure drop in the wicks. In this study, the pressure drop in the evaporator wick, artery wick, and condenser wick and the heat loss from the evaporator to the condenser through the artery wick were analyzed for the design of a 100 W AMTEC prototype. It was found that a particle diameter of 10 ${\mu}m$ is suitable for the evaporator wick to maintain a capillary pressure greater than total pressure drop in the circulation loop.

Growth and Characterization of ZnS Thin Films by Hot Wall Method (Hot Wall법에 의한 ZnS 박막의 제작과 특성)

  • Lee, Sang-Tae
    • Journal of Navigation and Port Research
    • /
    • v.26 no.1
    • /
    • pp.120-126
    • /
    • 2002
  • ZnS thin films were prepared on glass substrate at various deposition conditions by a HW apparatus and were systematically investigated the growth characteristics, in terms of deposition edges by a double beam spectro- photometer, and structural analysis by a x-ray diffraction rates were increased with incresing the cell temperature and vapor pressure of sulfur, but were decreased with increasing substrate temperature. The optical characteristics of thin films depends on the deposition rates. The band gap energies of 3.46∼3.52eV measured at room temperature are smaller than the theoretical value of 3.54eV, indicating that impurities exist in the crystal. All ZnS thin films are oriented in the (III) principal direction of a zincblende structure. By introducing the S vapor, optical and crystalline properties have been improved.

Comparison of the Friction-Loss Coefficient for the Gap of Two Contact Surfaces and a Crack (접촉한 두 평면과 균열한 틈새에서의 유동마찰계수 비교)

  • Nam, Ho-Yun;Choi, Byoung-Hae;Kim, Jong-Bum;Lee, Young-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1075-1081
    • /
    • 2011
  • A leak-detection method has been developed by measuring the pressure variation between the inner and outer heattransfer tubes of a double-wall tube steam generator. An experiment was carried out to measure the leak rate in the gap between two surfaces pressed with a hydraulic press in order to simulate the phenomena, and a correlation was determined for the leak rate in a micro gap. However, in the correlation, the gap width and friction coefficient were coupled with the surface roughness, which affects the two parameters. The two parameters were separated using a surface-contact model to develop a correlation for the friction coefficient. The correlation was compared with the existing correlations used for crack analysis. Although the applied ranges of Reynolds numbers were different, the developed correlation for Reynolds numbers of 0.1.0.35 showed similar tendencies to existing correlations used for higher Reynolds numbers.

Plugging and Re-opening Phenomena of the 5Cr-1Mo Steel Leak Hole by Water Leakage in Sodium Atmosphere (소듐 분위기에서 물누출에 의한 5Cr-1Mo Ferrite강 구멍의 막힘과 재개방 현상)

  • Jeong, Kyung-Chai;Kim, Tae-Joon;Choi, Jong-Hyeun;Park, Jin-Ho;Hwang, Sung-Tai
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.674-679
    • /
    • 1998
  • Small water leak experiment was carried out in liquid sodium atmosphere using a specimen of ferrite steel, which will be expected to be a material of the heat transfer tube of liquid metal fast breeder reactor. Self-plugging phenomena of leak path could be explained by the products of reaction and corrosion by sodium-water reaction. Also, re-opening mechanism of self-plugged path could be explained by the thermal transient and vibration of heat transfer tube. As a result, perfect re-opening time of self-plugged leak path was observed to be 129 minutes after water leak initiation. Re-opening shape of a specimen was appeared with double layer of circular type, and re-opening size of this specimen surface was about 2 mm diameter on sodium side.

  • PDF

Performance Evaluation of Concrete Bench Flume Using Industrial by Products (산업부산물을 이용한 콘크리트 벤치플룸의 성능평가)

  • Jae-Ho Jung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.276-281
    • /
    • 2023
  • Water pipes manufactured using existing Portland cement suffer from the problem of rapid deterioration and reduced durability due to the hydration product of cement being vulnerable to acids. Therefore, in this study, water pipes were manufactured using slag and fly ash, which are industrial by-products from various industries, and their characteristics were analyzed. As a result of the experiment, slump in unhardened concrete tended to increase due to the ball bearing action of fly ash, and the amount of air was reduced due to unburned coal, indicating that measures for frost resistance were needed. In addition, the initial strength of the compressive strength was increased through steam curing, and the results were equal to or better than OPC when mixing more than 50 % of slag. The acid resistance results showed that the mass reduction rate was less than 5 %, showing excellent durability performance, and the bending failure load of the water pipe also exceeded the KS standards, so it is judged to be commercializable.

In Vivo Study on the Biocompatibility of New Resin-based Root Canal Sealers (신개발 레진 계열 봉함제의 생체친화성에 관한 연구)

  • Kim, Yong-Beom;Baek, Seung-Ho;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.122-134
    • /
    • 2002
  • 목적 : 근관 치료의 최종 목적인 근관계의 영구적인 충전을 위해 사용되는 근관 봉함제는 많은 연구와 개선을 거쳐서 현재는 다양한 성분의 봉함제가 시판되고 있다. 이중에서 레진이 주성분인 봉함제는 조작이 편리하고 흐름성이 좋으며 근관의 벽에 높은 밀폐성을 보이고 충분한 작업시간과 높은 방사선 불투과성을 가지는 장점을 가짐에도 불구하고 높은 초기 생체 독성을 나타내는 단점을 가지고 있다. 본 실험에서는 기존의 상용화된 제품 중 레진이 주성분인 두 종류의 봉함제(AH 26, AH plus)와 산화아연이 주성분인 봉함제(Pulp Canal Sealer EWT)와 국내에서 새로이 개발한 제품으로서 레진이 주성분인 두 종류의 봉함제(Adseal-1,2)를 생체조직에 매식하여 국소적인 반응을 비교하여 생체친화성을 알아보고자 하였다. 방법 : 수종 봉함제의 생체 친화성을 알아보기 위하여 64마리의 Sprague-Dawley rat을 사용하였다. 봉함제의 피하조직 매식을 위해 길이와 직경이 각각 5와 1.5mm인 폴리에틸렌 테프론 관을 사용하였으며 이를 에탄올과 증류수로 세척 한 후 고압증기멸균을 시행하였다. Rat에 대하여 케타민으로 복강내 마취를 시행한 후 배부를 면도하고 iodine으로 소독한 다음 네 곳에 절개를 시행하였으며 blunt dissection을 통해 깊이 10mm이상의 피하조직 pocket을 형성하였다. 각각의 봉함제를 제조사의 지시 에 따라 혼합 후 즉시 멸균된 테프론 관에 주사기를 이용하여 담은 다음에 봉함제가 흐르지 않게 유의하며 pocket내로 삽입하였으며 이때 16개의 관을 대조군으로 사용하기 위해 봉함제를 넣지 않은 상태로 삽입하였다. 이 후 절개 부위를 surgical gut suture로 봉합하였으며 1주일 후에 발사하였다. Rat을 1, 2, 4, 12주 후에 각 군 당 세 마리 씩 에테르 흡입을 통해 희생하였으며 이 때 한 마리씩의 대조군도 포함시켰다. 이 후 매식된 관을 주위 조직과 함께 제거하고 포르말린에서 48시간 고정시킨 후 파라핀에 포매한 다음에 micro-tome을 사용하여 6$\mu\textrm{m}$로 serial section을 시행하였다. 정중선 부위의 시편에 Hematoxylin-Eosin staining을 시행한 후 Olsson, Orstavik 그리고 Mjor 등의 방법에 따라 조직학적 변화를 관찰한 후 slight(1), moderate(2), severe inflammation(3)의 단계로 분류하였다. 얻어진 결과를 통계처리 프로그램인 Jandel사의 Sigmastat을 이용하여 Kruskal Wallis Test로 통계처리를 하였다. 결과 : (Table omitted) 결론 : 1) Pulp Canal Sealer를 제외한 모든 군에서 시간이 지남에 따라 유의성 있게 염증이 감소되는 양상을 보였다(p<0.05). 2) Pulp Canal Sealer는 1주, 2주, 12주에서 강한 염증반응을 보였다. 3) AH 26과 AH Plus에서는 1주, 2주에서 강한 염증반응을 보였으나 12주에서는 염증반응이 감소하였다. 4) 새로 개발된 봉함제 Adseal-1,2는 1주, 2주에서는 가장 약한 염증반응을 보이나 4주, 12주 후에는 AH Plus와 비슷한 수준의 염증 반응을 보였다. 5) Pulp Canal Sealer를 제외한 모든 군에서 인정할 만한 생체친화성을 보였다. 6) Adseal-2가 Adseal-1에 비하여 전반적으로 낮은 염증반응을 보였다. 7) 각 군간 결과의 차이에 통계적 유의성은 없었다(p>0.05).

Analysis of Tube Support Plate Reinforcement Effects on Burst Pressure of Steam Generator Tubes with Axial Cracks (증기발생기 전열관지지판의 축균열 파열억제 효과 분석)

  • Kang, Yong Seok;Lee, Kuk Hee;Kim, Hong Deok;Park, Jai Hak
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.168-173
    • /
    • 2015
  • A steam generator tubing is one of the main pressure boundary of the reactor coolant system in the nuclear power plants. Structural integrity refers to maintaining adequate margins against failure of the tubing. Burst pressure of a tube at tube support plate can be higher than that for a free-span tube because failure behaviors could be interfered from the tube support plate. Alternative repair criteria for out-diameter stress corrosion cracking indications in tubes to the drilled type tube support plate were developed, however, there are very limited information to the eggcrate type tube support plate. This paper discussed reinforcement effect of steam generator tube burst pressure with axial out-diameter stress corrosion cracking within an eggcrate type tube support plate. A series of tube burst tests were performed under the room temperature and it was found out that there is no significant but marginal effects.

Experimental studies on the fretting wear of domestic steam generator tubes (국내 증기발생기 전열관 마열에 대한 실험적 연구)

  • Lee, Yeong-Ho;Kim, Hyeong-Gyu;Kim, In-Seop
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.304-309
    • /
    • 2002
  • Fretting wear test in room temperature water was performed to evaluate the wear coefficient of Inconel 600,690 (Pressurized Water Reactor, PWR) and Alloy 800 (CANadian DeuteriumUranium, CANDU) steam generator (SG) tubes against ferritic and martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel alloys. Test conditions are $10{\sim}30N$ of normal load, $200{\sim}450{\mu}m$ of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between martensitic and ferritic stainless steel. The wear rate and wear mechanism of two tubes in room temperature water are discussed.

  • PDF

C-Ring Stress Corrosion Test for Inconel 600 Tube and Inconel 690 welded by Nd:YAG Laser (Nd:YAG 레이저로 용접한 인코넬 600관과 인코넬 690의 C링 응력 부식시험)

  • 김재도;문주홍;정진만;김철중
    • Proceedings of the KWS Conference
    • /
    • 1998.10a
    • /
    • pp.288-291
    • /
    • 1998
  • Inconel 600 alloy is used as the material of nuclear steam generator tubing because of its mechanical properties, formability, and corrosion properties. According to reports, the life time of nuclear power plants decreases because of the pitting, intergranular attack, primary water stress corrosion cracking(PWSCC), and intergranular stress corrosion cracking(IGSCC), and denting in the steam generator. The SCC test is very important because of SCC appears in various environment such as solutions, materials, and stress. The C-Rig specimen was made of the steam generator welded sleeve repairing by the pulsed Nd:YAG laser. In the corrosion invironment, corrosion solutions are Primary Water, Caustic, and Sulfate solution and corrosion time is 1624-4877hr. The permitted stress is 30-60ksi.In this C-Ring SCC test is the relationship between corrosion depth, crack and corrosion environment is evaluated. SCC was happens in Sulfate and Corrosion solution but doesn't happen in Primary Water. The corrosion time and stress is very affected by the severely environment of Sulfate or Caustic solution. The microstructure observation indicates that SCC causes interganular failure in the grain boundary of vertical direction.

  • PDF