• Title/Summary/Keyword: 즉시 부하

Search Result 203, Processing Time 0.025 seconds

The effect of loading time on the stability of mini-implant (교정력 부하시기에 따른 교정용 미니 임플란트의 안정성)

  • Lee, Seung-Yeon;Cha, Jung-Yul;Yoon, Tae-Min;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.149-158
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the stability of mini-implants in relation to loading time. Methods: A total of 48 mini-implants (ORLUS, Ortholution, Korea) were placed into the buccal alveolar bone of the mandible in 8 male beagle dogs. Orthodontic force (200-250gm) was applied immediately for the immediate loading group while force application was delayed for 3 weeks in the delayed loading group. For the subsequent loading periods (3, 6, 12 weeks), BIC (bone implant contact) and BV/TV (bone volume/total volume) and mobility test were carried out. Results: The immediate loading group showed no changes in BIC from 3 to 12 weeks, while the delayed loading group showed a significant increase in BIC between 3 and 12 weeks (p<0.05). The BV/TO of the delayed loading group significantly increased from 6 to 12 weeks of loading (p<0.05), while the BV/TV of the immediate loading group decreased from 3 to 12 weeks of loading. However, there was no significant difference in BV/TV between experimental groups. The mobility of the immediate loading group was not significantly different from that of the delayed loading group after 12 weeks of loading (p<0.05). Conclusions: These results showed that immediate loading does not have a negative effect on the stability of mini-implants compared to the early loading method in both the clinical and histomorphometric point of view.

Effect of Implant Length on the Immediate Loading at the Anterior Maxilla (즉시하중시 상악 전치부에 식립된 임플란트 길이 변화에 따른 응력 분포의 삼차원 유한요소 연구)

  • Lee, Joon-Seok;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.255-265
    • /
    • 2009
  • Recently many studies have been published on application of immediate loaded implants. However, the immediate loading protocol has not been well documented. The purpose of the present study was to evaluate the stress distribution between bone-implant interfaces and the effect of implant length in the anterior maxilla using 3 dimensional finite element analyses. The diameter 4.0 mm threaded type implants with different length(8.5 mm, 10.0 mm, 11.5 mm, 13.0 mm, 15.0 mm) were used in this study. The bone quality of anterior maxillary bone block was assumed to D3 bone. Bone-implant interfaces of immediately loaded implant were constructed using a contact element for simulating the non osseointegration status. For simplification of all the processing procedures, all of the material assumed to be homogenous, isotropic, and linearly elastic. The 178 N of static force was applied on the middle of the palatoincisal line angle of the abutment with $120^{\circ}$ angle to the long axis of abutment. Maximum von Mises stress were concentrated on the labial cortical bone of the implant neck area, especially at the cortical-cancellous bone interfaces. Compared the different length, highest peak stress value was observed at the 8.5 mm implants and the results indicated a tendency towards favorable stress distribution on the bone, when the length was increased. Presence of cortical bone was very important to immediate loading, and it appears that implants of a length more than 13 mm are preferable for immediate loading at the anterior maxilla.

Immediately loaded dental implants with fixed prostheses using a computer-guided surgery in a mental retardation patient: a case report (정신지체장애환자에서 Computer-Guided Surgery를 이용한 임플란트 식립 및 즉시 보철물 장착: 증례보고)

  • Han, Se-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.246-252
    • /
    • 2014
  • $Br{\aa}nemark^{\prime}s$ original protocol required 4 to 6 months for implant osseointegration before placement of the definitive prosthesis. Although this approach gave very predictable results, it had certain drawbacks. The main disadvantages of this approach were prolonged treatment time, two surgical procedures, placement of a removable prosthesis that required modifications during the course of treatment, and a greater number of appointments. Immediate implant loading is a viable treatment method for selected cases. One of the greatest advantages of this method is the virtual surgery, which precedes the actual clinical treatment and eliminates any need for last minute decisions. The actual surgery time is decreased, since all steps are predetermined. These advantages aren't only more useful for normal patients but also for the mental retardation patients whose cooperation is difficult. This article presents a clinical approach made possible due to the guided implant surgery and CAD/CAM technique.

Esthetic restoration in mandibular anterior region with one-piece implant and immediate loading (하악 전치부에서의 일체형 임플란트 식립 후 즉시부하)

  • Yoon, Sena
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.97-104
    • /
    • 2018
  • Mandibular anterior region has high implant survival rates and better accessibility compared with any other region. Even if there are possibilities for perforation on lingual cortical bone due to improper drilling and bleeding caused by lingual artery damage, mandibular anterior region is a safe region because less amount of major anatomical structures exist compared with other regions. However, because of narrow bucco-lingual width of alveolar ridge, it is challengeable to obtain esthetic implant prosthesis. Although patients are less sensitive subjectively, mandibular anterior region is as difficult as maxillary anterior region in that implant placement location plays a critical role on the prognosis of implant prosthesis. One-piece implant is a very useful option for mandibular anterior region. Considering the narrow roots and thin alveolar bone of mandible, it is clinically difficult for implant diameter to be greater than 3mm In this case, we could approach the esthetic restoration in mandibular anterior region with one-piece implant and immediate loading.

Case report of immediate placement of maxillary central incisor due to traumatic injury (외상으로 인한 상악 중절치 발치 즉시 임플란트 증례 보고)

  • Choi, Minsik
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.2
    • /
    • pp.40-46
    • /
    • 2022
  • In maxilary anteriors, aesthetic aspect are of critical importance. but it is difficult to achieve esthetic results because of the narrow buccal-lingual alveolar bone width compared to the posterior teeth and alveolar bone resorption during tooth extraction. This case report describes how to minimize alveolar bone resorption and soft tissue collapse when immediate implant placement is done after extraction of the maxillary anterior teeth due to trauma.

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

Immediate Full Weight Bearing in Extension Brace Following Arthroscopic Primary Repair or Reconstruction of ACL (관절경하 전방십자인대 일차수복술 및 재건술후 신전보조기를 착용한 조기 완전체중부하)

  • Kim Jung Man;Chang Cheong Ho;Cho Woo-Shin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.128-131
    • /
    • 1997
  • 전방십자인대의 일차수복술이나 재건술후에 장기간의 비체중부하가 필요한지를 결정하기 위해서 일차수복술을 시행한 96례와 재건술을 시행한 82례등 총 178례를 대상으로 술후 체중부하시기에따라 두군으로 나누어 비교분석 하였다. 모든 례에서 술후 보조기를 착용하였고 120례에서는 술후 첫6주간 점차적으로 관절운동범위를 증가를 시키고 다음 6주간은 완전운동범위 회복상태에서 유지후 술후 12주에 체중부하를 허용하였으며 나머지 58례에서 술후 완전신전상태에서 즉시 체중부하를 시켜서 정기적으로 Lachman검사, KT 2000을 이용하여 불안정성여부를 관찰하였다. 평균 추시기간은 4.2년(2년$\~$6년)이었고 불안정성에 대한 평가는 AMA 분류에 따랐다. 최종추시상 모든환자에서 1+이상의 불안정성은 발견되지 않았으며 술후 12주에 체중부하를 한군에서 1a+가 104례$(86.7\%)$, 1b+군이 16례$(13.3\%)$로 관찰되고 즉시 체중부하를 한 군에서 1a+가 51례$(87.9\%)$, 1b+가 7례$(12.1\%)$에서 보였으나 통계적으로 의미있는 차이는 없었다(P>0.05). 본연구의 결과로 전방십자인대 일차수복술이나 재건술후 신전보조기를 착용시키고 즉시 보행을 시키는 것이 술후 슬관절의 불안정성에 영향을 주지 않으며 안전한 재활방법으로 생각된다.

  • PDF

Digital immediate implantation and aesthetic immediate loading on maxillary incisor displaced due to root fracture: a case report (치근파절로 변위된 상악 중절치의 디지털을 이용한 즉시 임플란트 식립 및 심미 수복 증례)

  • Jieun Song;Songyi Park;Chan Park;Kwidug Yun;Hyun-Pil Lim;Sangwon Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.267-275
    • /
    • 2023
  • To obtain better esthetic results when immediately placing a dental implant, the soft tissue surrounding the implant must be conditioned during healing of the extraction socket. To this end, the emergence profile can be customized through immediate restoration of the provisional prosthesis, and good clinical results can be obtained at the time of definitive restoration in the future, resulting in high patient satisfaction. In this case, horizontal root fracture occurred after trauma to both maxillary central incisors. Immediate implant placement and loading was planned considering aesthetics and alveolar bone condition. By taking an impression using a digital intraoral scanner, a digital diagnostic wax-up was performed to make a more aesthetic prosthesis without applying external force to the traumatized teeth. Based on this, the ideal placement location was determined and immediate implant placement was performed using a 3D printed surgical guide. The provisional prosthesis was restored 5 days after placement, and the definitive zirconia crown was restored through soft tissue conditioning and customization using the shape of the provisional prosthesis for 3 months.

Esthetic restoration in continuous maxillary anterior area using immediate implant placement: A case report (임플란트 즉시 식립에 의한 연속된 상악 전치부의 심미적 수복 증례)

  • Lee, Ye Chan;Shim, Jun Sung;Lee, Jae Hoon;Lee, Keun Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.403-409
    • /
    • 2017
  • In the case of an extraction in the maxillary anterior region, immediate placement of implant-supported fixed prosthesis can be considered as a treatment option. Fewer surgical operations, reduced treatment time, and optimal availability of existing bone are obvious advantages of the method; however, when applied in the continuous maxillary anterior region, inter-implant distance must be carefully considered, as well as accurate diagnosis and treatment planning for predictable outcome. In this case report, immediate placement of two implants in the continuous maxillary anterior along with bone graft following the extraction of root rests, and the restoration of provisional and implant-supported fixed prosthesis on a 63-year-old patient had resulted in both esthetically and functionally satisfactory clinical outcomes.