• Title/Summary/Keyword: 중앙환기

Search Result 62, Processing Time 0.033 seconds

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

A Study on the Measurement and Investigation of Air Quality in a University Library (대학도서관 실내 공기질 측정 및 조사 연구)

  • Lee, Jae-Won
    • Journal of Korean Library and Information Science Society
    • /
    • v.50 no.4
    • /
    • pp.635-658
    • /
    • 2019
  • In this study, the harmful factors measured in S university's central library were divided into ① air harmful substance ② biological harmful factors ③ carbon monoxide, carbon dioxide, and nitrogen dioxide concentration, measured and analyzed compared to the relevant criteria. The analysis showed that the harmful substances in the air - fine dust, asbestos, volatile organic compounds and formaldehyde - were all lower than the relevant standards, and that biological harmful factors such as fungi in the air, gramophageal bacteria, and endotoxin were also found to have no particular problems. The concentration of carbon monoxide, carbon dioxide, and nitrogen dioxide in the air was also maintained without any unusual factors compared to the concentration in the ordinary atmosphere. However, the library is a multi-use facility that needs regular cleaning and ventilation to manage the environment.

Characteristics of Heat Flux in a Compartment Fire - Reduced Scale Test (구획공간 화재의 열유속 특성 - 축소 실험)

  • Kim, Sung-Chan;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.128-133
    • /
    • 2011
  • The present study performs a series of 40 % reduced scale of ISO-9705 fire test to investigate the characteristics of heat flux on the floor level in terms of fire characteristics and location in the compartment. The heat flux was measured with Schmidt-Boelter type heat flux gauge at two locations on the floor level of inside and doorway side of the compartment. Different types of fuel - methane, heptane, toluene, ethanol, polystyrene - were burned in this test series. The measured heat flux inside of the compartment was relatively higher than that of front side as the heat release rate of fire and upper layer temperature increased. The difference of measured heat flux at inside and doorway side increased for high sooty fire. The present study shows that the heat flux distribution at lower layer greatly depend on the thermal radiation from fire and upper layer, not only the upper layer temperature but also various fire characteristics such as composition of combustion gases, soot concentration, ventilation condition and so on.

Musical Analysis on the Phrases of Chinese Poetry in Pansori Words (판소리 사설 중 한시 어구의 활용에 따른 음악적 분석)

  • Kim, Mi-Sook
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.4
    • /
    • pp.714-726
    • /
    • 2022
  • The purpose of this paper is to find out the way of utilizing phrases of Chinese poetry in Manjeongje and its musical characteristics. To this end, the roles of phrases contained in the Pansori words were classified into five patterns: landscape description, strengthening of pleasant emotions, strengthening of sad emotions, wordplay, and combination of various poems. As a result of analysis, phrases quoted in sad mood part consist of slow rhythm of Jinyangjo and Jungmori, and sad melody of Gyemyun-gil and Jingyemyun tone; thus, both the rhythm and melody are expressed in accordance with the mood of poems. On the other hand, the melody in the landscape description parts, and the rhythm in the joyful feeling and wordplay parts showed the characteristics of determining the mood. In addition, when applying the analysis results to the perspective of Pansori composition, it is necessary to discover novel texts, apply to editorials, and study musical implementation suitable for the original mood in order to create more artistic Pansori.

Factors Related to the Development of Myocardial Ischemia During Mechanical Ventilation (인공 호흡기 적용에 따른 심근 허혈의 발생에 관한 연구)

  • Kim, Tae-Hyung;Kim, You-Ho;Lim, Chae-Man;Kim, Won;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.645-653
    • /
    • 1999
  • Introduction : Although myocardial ischemia tends to occur more frequently than can he documented in ventilated patients, it has not been well studied on the factors related to the occurrence of the ischemia. Methods : To investigate the related factors to ischemia development, a prospective study was done in 95 cases with consecutive 73 patients who had received mechanical ventilation(MV) in MICU. In addition to 24 h holter monitoring, echocardiogram, electrolytes, cardiac enzymes, hemodynamic, and gas exchange measurements were done within 24 h after initiation of MV in 69 cases. The measurements were repeated at weaning period in 26 cases. The ischemia was defined by the ST segment changes; up-sloping depression more than 1.5 mm or down-sloping or horizontal depression more than 1.0 mm from isoelectric baseline for 80 ms following J point. Results : Twelve patients(12.6% in 95 cases) developed ischemia in total. The incidence of ischemia development showed an increased tendency in the initial 24 hr after MV (15.9%) and in patients with left-sided heart failure found by echocardiogram (18.2%) compared with that of the weaning period (3.8%) and patients without heart failure (10.9%) (P=0.12, P=0.09, in each). There were no differences in APACHE III score, baseline ECG findings, electrolytes abnormalities, use of inotropics or bronchodilators, presence of sepsis or shock, mode of ventilation, and survival rate according to the development of ischemia. Maximal heart rates and mean arterial pressure also were not different between patients with ($137.2{\pm}30.9/min$, $82.5{\pm}15.9$ mm Hg) and without ischemia ($l29.5{\pm}29.7/min$, $83.8{\pm}17.6$ mm Hg). Conclusion : Although the incidence of myocardial ischemia was 12.6% in total, there were no clinically predictable factors to the development of ischemia during mechanical ventilation.

  • PDF

Effect of Ventilating System on the Performance of Broiler Chicks in an Environmental Controlled Cage House (무창계사의 환기 시스템이 케이지 사육 육계의 초기 생산성에 미치는 영향)

  • HwangBo J.;Hong E.C.;Lee B.S.;Bae H.D.;Lee S.J.;Cho S.B.;Kim H.K.;Kim J.H.;Park B.S.;Song J.I.
    • Korean Journal of Poultry Science
    • /
    • v.33 no.1
    • /
    • pp.57-63
    • /
    • 2006
  • This study was conducted to investigate the effect of ventilating system of environmental controlled broiler house on broiler production. Three hundred eighty four broiler chicks (Hubbard, mean live weight of $44.5{\pm}2.0g/bird$) were reared for 2 wk. The results of the present study were summarized as follows : 1. Ammonia gas production was lower in the second and the third floors of cages compared with first floor of cages 13.5 and 13.5 vs 14.6 ppm, respectively). The observations of ammonia production in the morning and afternoon were similar. The production of carbon dioxide was not different between morning and afternoon, but it was tended to decrease in the forth floor of cages due to a fresh air 2. A wind velocity in the enclosed house was similar across lower, middle and upper section (0.57m/sec, 0.22m/sec and 0.04msec, respectively). In order to maintain an optimal air flow velocity in the cages, the duct entrance was punched, and then the air flow was full-round in the overall space in the cage. 3. Daily liveweight gain, feed intakes, and feed efficiency were not significant differences among treatments during whole experimental period (P>0.05). Therefore, the present results showed that temperature, moisture and atmosphere controlling were desirable, and air flew evenly in the cage.

Analysis of Etiology and Prognosis of Pulmonary Complications in Children with Hematological or Oncological Disorders in Pediatric Intensive Care Unit (소아 중환자실에 입원한 혈액-종양 환아에서 발생한 폐 합병증의 원인과 예후에 대한 분석)

  • Jung, Jin Young;Hong, Soo-Jong;An, Young Jun;Kim, Ja Hyung;Seo, Jong Jin;Moon, Hyung Nam;Ghim, Thad
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.8
    • /
    • pp.1000-1006
    • /
    • 2002
  • Purpose : In the course of treatment, patients with hematological or oncological disorders often develop pulmonary complication. The patients who develop a severe pulmonary complication have a poor outlook. The causes of pulmonary complication are either infectious or non-infectious in origin. We have analyzed the etiology and outcome of these patients admitted to the pediatric intensive care unit of Asan Medical Center. Methods : Medical records of 95 patients on Pediatric oncology service who were admitted to pediatric intensive care unit(PICU) of Asan Medical Center from Jan 1997 to May 2000 were retrospectively reviewed. Results : The mean age of the patients was 8.5 years(2 months-18 years). The underlying malignancies of these 95 patients were as following; acute lymphoblastic leukemia(31 cases), lymphoma (11 cases), acute myeloid leukemia(nine cases), brain tumor(eight cases) and other solid tumors(25 cases). Pulmonary complications included pneumonia, acute respiratory failure, pneumothorax and pleural effusion. The most common cause of pulmonary complication was infection(88%) in etiology. The overall mortality rate was 56.8%. Pulmonary complications in these patients carried high rates of mortality regardless of whether they were immune compromised(76%) or not(69%). Even without pulmonary complications, the hematological or oncological patients admitted to PICU had high mortality rates of 43%. Conclusion : Pulmonary complications are frequent finding in the hematological or oncological patients admitted to Intensive Care Unit. The main etiology of these pulmonary complications was infection, which carried a high mortality rate regardless of their immune status at the time when they were admitted to PICU.

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF

Development of Safety Usage Guidelines for Sedative Hypnotics Using the Delphi Technique (델파이 기법을 이용한 다빈도 수면진정제 안전사용지침 개발)

  • Nam, Yoon-Ju;Cho, Chul-Hyun;Lee, Yujin;Lee, Heon-Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.26 no.2
    • /
    • pp.86-103
    • /
    • 2019
  • Objectives: The objective of this study was to develop evidence- and consensus-based clinical safety usage guidelines for sedative hypnotics using the Delphi technique. Methods: A group of 15 sleep experts from Korean Academy of Sleep Medicine were chosen for this study comprising a three-round web-based Delphi survey. The first round survey was composed of 39 questions to identify problems with sedative hypnotics usage in Korean clinical practice and the result roughly outlined what should be included in the guidelines. The second round survey was composed of 21 questions to collect specific opinions of experts on clinically important issues in prescribing sedative hypnotics, and its result provided the basis for the guidelines. A third round survey aimed to evaluate the reliability and validity of the established guidelines. Results: In the third round, all 17 items showed a median of 4 or more, with an average of 4.12 and a standard deviation of 0.32. Thus we present safety usage guidelines with 13 propositions for prescription, maintenance, and withdrawal of sedative hypnotics. Conclusion: The safety usage guidelines on sedative hypnotics developed from this study could lead to safe and effective prescription of hypnotics in clinical practice, especially for the non-experts in sleep medicine. Furthermore, the guidelines will help to improve the quality of insomnia treatment by contributing to the establishment of a safe regime for sedative hypnotics without excessive use of drugs.

Influenza A Outbreak in a Neonatal Intensive Care Unit During the 2011-2012 Influenza Season in Korea (2011-2012년 인플루엔자 국내 유행시기에 신생아 중환자실에서 발생한 A형 인플루엔자 바이러스 집단발병)

  • Son, Ok Sung;Oh, Chi Eun;Kong, Seom Gim;Jung, Yu Jin;Hong, Yoo Rha
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.2
    • /
    • pp.87-93
    • /
    • 2016
  • Purpose: An outbreak of influenza virus is uncommon in neonatal intensive care unit (NICU). The clinical presentation of influenza virus infection in neonates is diverse. This study was aimed to report an outbreak of influenza A in a NICU and to investigate the clinical characteristics of influenza virus infection in neonates especially preterm infants during the 2011-2012 influenza season in Korea. Methods: We reviewed the medical records of 29 patients who were evaluated by respiratory virus multiplex reverse transcriptase-polymerase chain reaction (RT-PCR) at NICU of Kosin University Gospel Hospital during the 2011-2012 seasonal influenza outbreak in Korea. Results: Eleven patients (37.9%) were influenza A virus RT-PCR positive during the survey periods. They were all preterm infants and three of them had no symptoms. Eight patients had symptoms and it was fever (18%, 2/11), respiratory difficulty (72.7%, 8/11) without symptoms of upper respiratory infection, and gastrointestinal symptoms (27.3%, 3/11). The median duration of symptom was 5 days. There were differences of duration of admission at the test of respiratory RT-PCR, Clinical Risk Index for Babies (CRIB) score, use of mechanical ventilation, and use of dexamethasone before infection between influenza A virus RT-PCR positive and negative group. All 11 patients with influenza A were discharged without any complications. Conclusions: The symptoms of influenza A virus infection in the preterm infants is nonspecific. Influenza A virus should be considered as a possible cause of infection in NICU during the influenza season in the community.