• Title/Summary/Keyword: 중앙모니터링 시스템

Search Result 144, Processing Time 0.026 seconds

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

A Study on Development of App-Based Electric Fire Prediction System (앱기반 전기화재 예측시스템 개발에 관한 연구)

  • Choi, Young-Kwan;Kim, Eung-Kwon
    • Journal of Internet Computing and Services
    • /
    • v.14 no.4
    • /
    • pp.85-90
    • /
    • 2013
  • Currently, the electric fire prediction system uses PIC(Peripheral Interface Controller) for controller microprocessor. PIC has a slower computing speed than DSP does, so its real-time computing ability is inadequate. So with the basic characteristics waveform during arc generation as the standard reference, the comparison to this reference is used to predict and alarm electric fire from arc. While such alarm can be detected and taken care of from a remote central server, that prediction error rate is high and remote control in mobile environment is not available. In this article, the arc detection of time domain and frequency domain and wavelet-based adaptation algorithm executing the adaptation algorithm in conversion domain were applied to develop an electric fire prediction system loaded with new real-time arc detection algorithm using DSP. Also, remote control was made available through iPhone environment-based app development which enabled remote monitoring for arc's electric signal and power quality, and its utility was verified.

Deep Learning-based Approach for Visitor Detection and Path Tracking to Enhance Safety in Indoor Cultural Facilities (실내 문화시설 안전을 위한 딥러닝 기반 방문객 검출 및 동선 추적에 관한 연구)

  • Wonseop Shin;Seungmin, Rho
    • Journal of Platform Technology
    • /
    • v.11 no.4
    • /
    • pp.3-12
    • /
    • 2023
  • In the post-COVID era, the importance of quarantine measures is greatly emphasized, and accordingly, research related to the detection of mask wearing conditions and prevention of other infectious diseases using deep learning is being conducted. However, research on the detection and tracking of visitors to cultural facilities to prevent the spread of diseases is equally important, so research on this should be conducted. In this paper, a convolutional neural network-based object detection model is trained through transfer learning using a pre-collected dataset. The weights of the trained detection model are then applied to a multi-object tracking model to monitor visitors. The visitor detection model demonstrates results with a precision of 96.3%, recall of 85.2%, and an F1-score of 90.4%. Quantitative results of the tracking model include a MOTA (Multiple Object Tracking Accuracy) of 65.6%, IDF1 (ID F1 Score) of 68.3%, and HOTA (Higher Order Tracking Accuracy) of 57.2%. Furthermore, a qualitative comparison with other multi-object tracking models showcased superior results for the model proposed in this paper. The research of this paper can be applied to the hygiene systems within cultural facilities in the post-COVID era.

  • PDF

Development of Multi-channels NMEA0183 Indicator System (다채널 NMEA0183 인디케이트 시스템 개발)

  • Kim, Gwan-Hyung;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2327-2332
    • /
    • 2011
  • Recently, the increase of loading amount on cargo ships due to the automation of loading process results in much complex ship operation. For this reason, NMEA-0183 based on RS-422,485 and NMEA-2000 based on CAN communication methods have been usually used as a standardized method in the marin electric interfacing equipments. In this paper, a general NMEA-0183 protocol was designed to support 7-channel NMEA-0183 serial communication data, which can receive 3-channel 16 bits ADC and 2-channel pulse using SPI(Serial Peripheral Interface). In particular, this method was designed for ship communication requires 7 important factors. Also in this study, using the minimization of the proposed method and realizing the monitoring system based on PC, the effectiveness of multichannel indicator system was proposed.

Optical Line Remote-Monitoring System Using Reflecting Filter (반사필터를 이용한 광선로 원격감시 시스템)

  • Jung, So-Ki;Cha, Kyoung Cheon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.6
    • /
    • pp.357-364
    • /
    • 2014
  • In this paper deals with PON Remote monitoring solution using Reflecting Filter. The current FTTH-PON can not be monitored in real time that Optical cable fault and Quality degradation of Splitter. To solve this problem, Monitoring can make Feeder Network and Splitter that Reflecting filter development using the basic structure of Fiber Bragg grating. Reflecting Filter is Quality Monitoring System shall provide tools for user to view and analyze degradation of cables and splitter in particular predict any gradual component degradation(Optical cable bending, splice, connector, etc) before it becomes service impacting. The Reflecting Filter solution is splitter down and confirm the fault location of optical cable and it will send central control station can be monitored system an alarm to the OLT. In other words, wavelength side branches Mating existing communication affairs (Coupler) using the core of one optical wavelength for live monitoring two wavelengths and sends the subscriber side modem and aggregation switch device remotely using a reflective optical line filter monitoring the study of the system. this study can development of Reflecting filter improve the average processing time of Optical cable fault and efficient Maintenance of the network.

Design of Communication Middleware for HACCP Automation System using Lightweight Devices (경량 단말기를 사용하는 HACCP 자동화 시스템의 통신 미들웨어 설계)

  • Hyun, Sung-Young;Cha, Kyung-Ae;Hong, Won-Kee
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.4
    • /
    • pp.11-23
    • /
    • 2015
  • In this paper, we propose a communication middleware for development of HACCP(Hazard Analysis and Critical Control Point) automation system, which is composed of lightweight devices and a server, to support effective HACCP data management. To provide the proper HACCP data to lightweight devices, we design the communication message protocol based on HACCP management regulation model. Moreover, we develop the communication middleware that performs various functions, such as processing of communication protocols for HACCP data, analyzing of messages between devices and a server, and providing database managements tools. In addition, it takes a role to guarantee sharing consistent data among the devices and server, through the active updates for information on devices. Actually, the proposed communication middleware can be a part of critical system to develop a HACCP automation system with lightweight devices, because it implements the HACCP communication protocols making lightweight devices execute every HACCP task.

A Report of the Assistive Technology Service Operating System for the Disabled in Sweden (스웨덴 장애인 보조기구 제공 시스템에 대한 소고)

  • Choi, Young Soon
    • 재활복지
    • /
    • v.18 no.4
    • /
    • pp.25-45
    • /
    • 2014
  • The present report aims to examine the assistive technology(AT) service operating system for the Disabled in Sweden, and will give it to NHIS(National Health Insurance Service) to manage of policy for AT service operating system. The user of AT is around 10% of the Disabled in Sweden which is introduced the AT service system to support the independence for the Disabled. To provide AT service, the role of the Ministry of Health(planning and regulation, controling Handisam and Hi as a subsidiary), County councils(providing and follow up medical AT service, operating AT service center) and Municipalities(providing general AT service) in Sweden is decentralized strictly. Specially, all the AT device is lent freely and recycled suitably for persons with Disabilities, moreover nurses, physical therapist and occupational therapist has a qualification for prescription of AT device . This finding will be the basis to improve Assistive Technology Operating System in Korea.

A Study on System Tracing User Activities in the Windows Operating System (윈도우 운영체제 상의 사용자 행위 추적에 관한 연구)

  • Jung, Chang-Sung;Kim, Young-Chan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.4
    • /
    • pp.101-114
    • /
    • 2011
  • As it seems like critical information leakages have been increasing due to industrial espionage and malicious internal users, the importance of introducing audit and log security technology is growing every now and then. In this paper, we suggest the session logging system for the company's internal control to meet the SOX legislation level, by monitoring and analyzing users behaviors connecting to the business-critical Operating System. The system proposed in this paper aims to monitor the user's illegal activities in the Operating System, and to present the clear evidence of purpose of those activities by detailed logs. For this purpose, we modified Operating System by adding multiple services suggested in this paper. These services utilize interfaces provided by the existing Operating System and add functions to control access and get logs. The system saves and manages session logs of users or administrators connected to the server with centralized log storage. And the system supports session log searching and lookup features required by SOX legislation for the company's internal controls with the level of computer forensics and logging technology.

Real-time Environmental Radiation Monitoring System with Automatic Restoration of Backup Data in Site Detector via Communication using Radio Frequency (현장검출기에 저장된 백업데이터를 무선통신방식으로 자동 복원하는 실시간 환경선량 감시 시스템)

  • Lee, Wan-No;Kim, Eun-Han;Chung, Kun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo;Park, Ki-Hyun;Kim, Yun-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.255-261
    • /
    • 2003
  • An environmental radiation monitoring system based on high pressurized ionization chamber has been used for on-line gamma monitoring surrounding the KAERI (Korea Atomic Energy Research Institute), which transmits the dose data measured from ion chamber on the site via radio frequency to a central processing computer and stores the transmitted real-time data. Although communication using radio frequency has several advantages such as effective and economical transmission, storage, and data process, there is one main disadvantage that data loss during transmission often happens because of unexpected communication problems. It is possible to restore the loss data by off-line such as floppy disk but the simultaneous process and display of current data as well as the backup data are very difficult in the present on-line system. In this work, a new electronic circuit board and the operation software applicable to the conventional environmental radiation monitoring system are developed and the automatical synchronization of the ion chamber unit and the central processing computer is carried out every day. This system is automatically able to restore the backup data within 34 hours without additional equipments and also display together the current data as well as the transmitted backup data after checking time flag.

A Study on CPPS Architecture integrated with Centralized OPC UA Server (중앙 집중식 OPC UA 서버와 통합 된 CPPS 아키텍처에 관한 연구)

  • Jo, Guejong;Jang, Su-Hwan;Jeong, Jongpil
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.73-82
    • /
    • 2019
  • In order to build a smart factory, building a CPPS (Cyber Physical Product System) is an important system that must be accompanied. Through the CPPS, it is the reality of smart factories to move physical factories to a digital-based cyber world and to intelligently and autonomously monitor and control them. But The existing CPPS architectures present only an abstract modeling architecture, and the research that applied the OPC UA Framework (Open Platform Communication Unified Architecture), an international standard for data exchange in the smart factory, as the basic system of CPPS It was insufficient. Therefore, it is possible to implement CPPS that can include both cloud and IoT by collecting field data distributed by CPPS architecture applicable to actual factories and concentrating data processing in a centralized In this study, we implemented CPPS architecture through central OPC UA Server based on OPC UA conforming to central processing OPC UA Framework, and how CPPS logical process and data processing process are automatically generated through OPC UA modeling processing We have proposed the CPPS architecture including the model factory and implemented the model factory to study its performance and usability.