• Title/Summary/Keyword: 중심 오차

Search Result 818, Processing Time 0.028 seconds

Comparison of Calibration Models for GPS Antenna Phase Center Variations (GPS 안테나 위상중심변동 보정모델 비교)

  • Park, Kwan-Dong;Won, Ji-Hye
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.4
    • /
    • pp.319-326
    • /
    • 2006
  • To get the highly-accurate and precise position of a GPS receiver, they should consider the state-of-the-art GPS force and measurement models. Especially, the phase center variations (PCV) of a GPS antenna can cause several centimeters of positioning errors in the vertical direction. In this study, we implemented four different models of PCV and evaluated their impact on the computed coordinates. The test data were taken from the 14 National Geography Information Institute permanent GPS stations and 30 Minisry of Government Administration and Home Affairs sites. For different combinations of calibration methods, an average of 1.3-2.6cm of height difference was observed. Also, we found a maximum error of ${\sim}4mm$ in the estimates of the precipitable water vapors.

A RSSI based Position Calibration Using Removing Statistical Outlier (특이점 제거를 통한 RSSI 기반의 위치 정보 보정)

  • Kim, Jae Hyoung;Kim, Kang Hyoun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.05a
    • /
    • pp.425-428
    • /
    • 2013
  • 본 논문에서는 RSSI 기반의 위치 추정 시스템에서 위치 오차를 보정하여 정확도 향상을 위한 방법을 제안한다. 다중 노드의 RSSI값을 이용하여 삼변 측량을 사용하여 위치를 추정할 때, 추정 좌표들 집합의 외곽선을 이은 다각형의 무게중심 알고리즘을 활용할 경우 상대적으로 큰 오차가 발생되는 특이점을 제거하여 무게중심을 구하여 정확도를 향상하는 방법을 제안한다.

A Comparison of Typhoon Wind Models with Observed Winds (해상풍 관측자료에 근거한 태풍 해상풍 모형간의 상호비교)

  • 강시환;전기천;박광순;방경훈
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.7 no.3
    • /
    • pp.100-107
    • /
    • 2002
  • The sea-surface winds during the passage of 64 typhoons for 1979-1999 were simulated using two different typhoon wind models, ie, typhoon parametric model(TPM) and primitive vortex model(PVM). The model hindcast winds were compared with the winds observed at JMA ocean buoys(22001 and 21002) and Kyushu ocean observation tower. The analysis of ms and relative errors between hindcast and observed winds was made to find the accuracy and sensitivity of the typhoon wind prediction models. Both hindcast winds of TPM and PVM underestimate the observed typhoon winds, but PVM winds are more closer to the observations with less rms and relative errors. Relative errors of two model winds were small within 200km from typhoon center, but TPM's relative errors increase up to 70% as the radial distance from typhoon center increases beyond > 200km although PVM's relative errors remain in 20% with less sensitive to the distance from typhoon centers.

3-Dimensional Verification Technique for Target Point Error (자기공명영상기반 겔 선량측정법을 이용한 3차원적 목표 중심점 점검기술)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • For overall system test, hidden-target test have been used using film which leads to inherent analysis error. The purpose of our study is to quantify this error and to propose gel dosimeter based verification technique for 3-dimensional target point error. The phantom was made for simulation of human head and this has ability to equip 10 gel-dosimeter. $BANGkit^{TM}$ which we are able to manufacture whenever it is needed as well as to easily change the container with different shapes was used as a gel dosimeter. The 10 targets were divided into two groups based on shapes of areas with a planned 50% isodose line. All treatment and analysis was performed three times using Novalis and $BrainSCAN^{TM}$. The target point error is $0.77{\pm}0.15mm$ for 10 targets and directional target point error in each direction is $0.54{\pm}0.23mm$, $0.37{\pm}0.08mm$, $0.33{\pm}0.10mm$ in AP (anterior-posterior), LAT (lateral), and VERT (vertical) direction, respectively. The result of less than 1 mm shows that the treatment was performed through each precise step in treatment procedure. In conclusion, the 3-dimensional target point verification technique can be one of the techniques for overall system test.

Improvement of Bit Rate Using Concentration of the Distribution of Prediction Errors (예측오차 분포의 집중화를 이용한 비트율 개선)

  • 김형철
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.207-210
    • /
    • 1998
  • 기존의 DPCM에 의한 압축방법은 예측오차를 양자화하여 전송한 후 복원하는 것으로 8레벨로 양자화하는 경우 3bpp의 비트율을 갖는다. 본 논문에서는 화소값의 압축에 의해 기존의 DPCM보다 예측오차값의 분포를 0을 중심으로 더 집중시킴으로써 더 낮은 비트율을 갖는 압축방법을 제안한다. 압축된 각 화소의 예측오차값은 DPAM방법에 의해 8-레벨로 양자화되고, 양자화된 예측오차의 열을 4와 2 단위로 분할하여 예측오차의 학습된 열로 구성된 각각의 코드북과 비교한다. 비교 결과 코드북의 주소를 생성하여 전송하고, 복원시 화소값을 확장한다. 제안된 방법은 DPCM방법보다 2.4~4.06dB 낮은 복원 영상의 화질을 보이지만, 비트율은 2.17~2.34bpp를 얻음으로써 0.66~0.83bpp정도 개선할 수 있다.

  • PDF

금형부품측정 On-line 시스템

  • 박희재;황상욱;김태수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.232-236
    • /
    • 1992
  • 컴퓨터로부터 디자인된 부품을 CMM(Coordinate Measuring Machine)과 연결함으로서 측정 의 자동화를 이룰수 있다. 또한, 기존의 여러 CAD시스템들은 모델의 형상오차와같은 정보는 지원하지 않기 때문에 측정의 자동화의 기능은 완전한 모델 디자인을 통한 CAD 시스템의 지원 으로 확장될수 있다. 여기에서는 금형의 부품중에서 메인플레이트(Main Plate)와 핀 및 부시 류(Pins and Bushings)를 다루며, 이들의 형상오차(From Tolerance)와 오리엔테이션 오차( Orientation Tolenrance)를 중심으로 한국공업규격에 근거하여 측정 및 분석이 이루어진다.

Segmentation of Arcs and Line Segments in Planar Curve Using CI Method (CI 방법을 이용한 2차원 곡선 내의 호 및 선분 분리)

  • Lyu, Sung-Pil
    • Journal of Internet Computing and Services
    • /
    • v.9 no.1
    • /
    • pp.145-158
    • /
    • 2008
  • The detected arcs by the cone intersection(CI) method exist within a tolerant error from the original curve. But the position of breakpoint by the CI method is sensitive to the tolerant error. The deviation of breakpoint position makes ill effects to the detection of arc center or radius. In this paper a improved CI method for center detection and arc segmentation is proposed. The detected arcs from curves by the proposed method have very stable mean of deviations from the original curves. The experimental results show that the position of breakpoint by the proposed method is closer to real position than the one by other methods.

  • PDF

3D 치료시 Couch rotation에 의한 Isocenter 변화에 대한 고찰

  • 박용철;주상규;송기원;정천영
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.144-146
    • /
    • 2000
  • 삼차원 입체조형치료는 정상조직의 장해를 최소화하고 종양부위에 집중적으로 조사할 수 있는 장점을 가지고 있어 임상 적용범위가 넓어지고 있다. 일반적으로 정상조직의 장해를 줄이기 위해 다양한 방사선 조사방향이 사용되며 특히 비 동일면상에서의 조사가 많이 이루어진다. 따라서 couch 회전이 동반되며 couch는 선형가속기의 다른 기계적 오차보다 많은 오차를 유발할 수 있는 잠재적인 위험을 안고 있다. 저자는 이러한 오차의 정도를 파악하고 이를 개선할 수 있는 방법에 대해 알아보고자 했다. couch 회전에 따른 Isocenter의 변화를 평가하기 위해 3대(Primus, Simens, USA/CL600c & 2100c, Varian, USA)의 선형가속기를 이용하였으며 이중 1대의 장비에는 couch 회전시 오차를 줄이기 위해 고안된 couch 고정장치를 장착하였다. 환자가 테이블에 부하를 주지 않은 상태에서 회전을 실시하여 Isocenter의 변화를 측정하고 환자가 테이블에 누워있는 상황을 재현하기 위해 human phantom을 위치시킨 후 동일한 회전검사를 실시하여 각각의 오차를 비교 분석하였다. 각 실험은 10회씩 반복 측정하여 평균치를 얻었으며 오차의 분석은 AAPM 권고안인 오차중심의 반경으로 표현했다. 3대의 선형가속기를 이용하여 얻은 결과 테이블에 부하를 주지 않은 상태의 회전오차는 평균 2mm, 3.2mm, 2mm로 측정되었으며 휴먼 phantom을 올려놓고 부하를 준 상태에서의 오차는 평균 2.1mm, 4mm, 2.1 mm이였다. 또한 고정장치를 이용한 상태에서의 평균오차는 1.9mm로 나타났다. 삼차원 입체조형치료 시 couch 회전에 따른 Isocenter 오차는 장비의 종류 및 작업자의 사용방법에 따라 다르게 나타났으며 테이블의 부하가 클수록 많은 오차를 보였다. 또한 couch 고정장치를 부착한 장비에서의 결과치 만이 AAPM에서 권고하는 오차의 한계에(${\le}2mm$) 들어감을 알 수 있었다. 따라서 정기적인 QA가 필수적이며 Couch Locking System과 같이 오차를 줄일 수 있는 보조장치의 부착이 많은 도움을 줄 것으로 생각된다. 아울러 이러한 오차를 보정할 수 있는 방법이 강구되어야 할 것으로 사료된다.

  • PDF

Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery (방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검)

  • Chung, Hyun-Tai;Lee, Re-Na
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.47-51
    • /
    • 2008
  • Objective: This study analyzed errors due to rotation or tilt of the magnetic resonance (MR) imaging indicator during image acquisition for a stereotactic radiosurgery. The error correction procedure of a commercially available stereotactic neurosurgery treatment planning program has been verified. Materials and Methods: Software virtual phantoms were built with stereotactic images generated by a commercial programming language, Interactive Data Language (version 5.5). The thickness of an image slice was 0.5 mm, pixel size was $0.5{\times}0.5mm$, field of view was 256 mm, and image resolution was $512{\times}512$. The images were generated under the DICOM 3.0 standard in order to be used with Leksell GammaPlan$^{(R)}$. For the verification of the rotation error correction function of Leksell GammaPlan$^{(R)}$, 45 measurement points were arranged in five axial planes. On each axial plane, there were nine measurement points along a square of length 100 mm. The center of the square was located on the z-axis and a measurement point was on the z-axis, too. Five axial planes were placed at z=-50.0, -30.0, 0.0, 30.0, 50.0 mm, respectively. The virtual phantom was rotated by $3^{\circ}$ around one of x, y, and z-axis. It was also rotated by $3^{\circ}$ around two axes of x, y, and z-axis, and rotated by $3^{\circ}$ along all three axes. The errors in the position of rotated measurement points were measured with Leksell GammaPlan$^{(R)}$ and the correction function was verified. Results: The image registration errors of the virtual phantom images was $0.1{\pm}0.1mm$ and it was within the requirement of stereotactic images. The maximum theoretical errors in position of measurement points were 2.6 mm for a rotation around one axis, 3.7 mm for a rotation around two axes, and 4.5 mm for a rotation around three axes. The measured errors in position was $0.1{\pm}0.1mm$ for a rotation around single axis, $0.2{\pm}0.2mm$ for double and triple axes. These small errors verified that the rotation error correction function of Leksell GammaPlan$^{(R)}$ is working fine. Conclusion: A virtual phantom was built to verify software functions of stereotactic neurosurgery treatment planning program. The error correction function of a commercial treatment planning program worked within nominal error range. The virtual phantom of this study can be applied in many other fields to verify various functions of treatment planning programs.

Vector Quantization using Genetic Algorithm (유전자 알고리즘을 이용한 벡터 양자화)

  • 임현택
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.197-200
    • /
    • 1998
  • 본 논문에서는 유전자 알고리즘(genetic Algorithm)을 사용하여 벡터 양자화(vector quantization : VQ)를 수행하는 방법을 제안하고자 한다. 벡터 양자화를 수행하여 코드북(codebook)을 생성할 때 생성된 코드북과 학습벡터(training vector)사이에는 반드시 양자화 오차(quantization error)가 발생하는데 기존의 K-means 알고리듬을 사용하여 코드북을 생성했을 경우 양자화 오차를 줄이는데 한계가 있었다. 본 논문에서 제안하는 유전자 알고리즘을 이용한 벡터 양자화는 이 양자화 오차를 감소시키기 위해서 연구되었다. 제안한 방법의 성능을 평가하기 위해 음성데이터를 기존의 K-means 알고리즘에서 클러스터의 중심을 선택하는 방법중의 하나인 Minimax방법으로 코드북을 생성하여 제안한 방법과 양자화 오차를 비교한 결과 양자화 오차가 감소됨을 알 수 있었다.

  • PDF