• Title/Summary/Keyword: 중심정맥관

Search Result 43, Processing Time 0.027 seconds

Retrospective Analysis for Complications of the Central Venous Catheter in Patients with Cancer at a Single Center in Korea (우리나라 일개 병원 암 환자에서 중심정맥관 합병증에 관한 후향적 조사)

  • Kim, Eun-Jung;Kim, Hyun-Jung;Kim, Han-Jo;Kim, Kyoung-Ha;Kim, Se-Hyung;Lee, Sang-Cheol;Bae, Sang-Byung;Kim, Chan-Kyu;Lee, Nam-Su;Lee, Kyu-Taek;Park, Sung-Kyu;Won, Jong-Ho;Park, Hee-Sook;Hong, Dae-Sik
    • Journal of Hospice and Palliative Care
    • /
    • v.13 no.1
    • /
    • pp.24-31
    • /
    • 2010
  • Purpose: A central venous catheterization (CVC) is frequently used for delivering anti-cancer chemotherapeutic agents, blood products, parenteral nutrition, and other intravenous therapy in patients with cancer. Major complications of CVC use are thrombosis, infection, and mechanical complications. The aim of this study was to evaluate the frequency of CVC complications and related factors. Methods: The records of cancer patients who received a CVC at our university hospital from March 2001 to October 2006 were retrospectively investigated. Chi square test was used to determine whether there was a related factor for thrombosis or infection, and Kaplan-Meier analysis for univariate analysis, or Cox-regression analysis for multivariate analysis was used for catheter life span. Results: Three hundred and ten CVCs (235 nontunneled, 75 tunneled) were inserted in 310 patients (157 males, 153 females). Among them, 104 had hematologic cancers and 206 had solid cancers. The mean age of the patients was 52 years (range, 19~82 years). CVC complications occurred in 60 cases (19%). CVC-related thrombosis occurred frequently in patients with infection (P=0.003), whereas diagnosis, catheter type, transfusion, and TPN history did not affect infection or thrombosis. The mean duration of the catheter was 102 days (range, 2~1,330 days), and the duration was prolonged in patients with tunneled catheters (P=0.000), or without transfusion through CVC (P=0.030). Conclusion: The major complications for long-term use of a CVC were infectionand thrombosis. Tunneled catheter was effective tool for long term use, especially in cases without transfusion through CVC. The studies on the prevention or treatment ofthrombosis and infection are, therefore, warranted by using CVC for an extended period of time.

Mediastinitis after Central Venous Catheterization (중심정맥관 삽입후 발생한 종격동염-1례 보고)

  • Keum, Dong Yoon;Park, Nam Hee;Lee, Kee Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.1
    • /
    • pp.64-67
    • /
    • 2005
  • We report here on an uncommon case of mediastinitis that occurred after central venous catheterization. A patient with colon and jejunal cancer complained high fever, right shoulder pain, chest pain, and limited motion of the affected shoulder just 6 days after central venous catheterization. Bacterial culture of the blood, shoulder abscess, and catheter puncture site revealed methicillin-resistent staphylococcus aureus. Right upper mediastinal widening on chest film also suggested mediatinitis. Mediastiotomy and pus drainage was performed along with adequate antibiotics therapy. In this case, it seems that initially formed bacteria from the puncture site migrated to the mediastinum through the tissue plane to start the mediastinitis. Careful dressing of puncture site and correct handling of catheter is important to prevent this serious complication.

Knowledge and Performance Level of Infection Control Guidelines on Indwelling Urinary Catheter, Central Venous Catheter and Ventilator Among Intensive Care Nurses (중환자실 간호사의 유치도뇨관, 중심정맥관 및 인공호흡기 감염관리에 대한 지식과 수행도)

  • Ha, Hyun-Jung;Park, Jung-Ha;Kim, Myung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.113-120
    • /
    • 2016
  • The purpose of this study is to identify the knowledge of and adherence to the infection control guidelines for indwelling urinary catheters, central venous catheters and ventilators among intensive care nurses. The subjects were 175 intensive care nurses working in 2 upper general hospitals and 3 general hospitals. Data were collected from July 1 to July 31, 2013. The collected data were analyzed by descriptive statistics, t-test and ANOVA using SPSS 18.0 for Windows. The mean scores of the knowledge of the infection control guidelines on indwelling urinary catheters, central venous catheters and ventilators were 0.87, 0.82 and 0.82 points, respectively. The average scores for the adherence to the infection control guidelines for indwelling urinary catheters, central venous catheters and ventilators were 4.18, 4.04 and 4.07 points, respectively. Statistically significant correlations were found between the knowledge of and adherence to the infection control guidelines for indwelling urinary catheters (r=.72, p<.00), central venous catheters (r=.54, p<.001) and ventilators (r=.30, p<.001). The knowledge of and adherence to the infection control guidelines for indwelling urinary catheters differed significantly according to gender, educational status, total career, number of patients, type of hospital, and attendance of seminar. The knowledge of and adherence to the infection control guidelines for central venous catheters differed significantly according to educational status, total career, number of patients, type of hospital, and attendance of seminar. The knowledge level of the infection control guidelines for the ventilator differed significantly according to the total career. The results of this study indicate that education and training programs for improving the knowledge of adherence to the infection control guidelines should be developed.

The Central Venous Catheter-related Infection of Chlorhexidine-silver Sulfadiazine Coated Catheters in Medical ICU (내과계 중환자실 환자에서 Chlorhexidine-silver Sulfadiazine Coated Catheter의 중심정맥관 감염에 대한 연구)

  • Jung, Young Ju;Koh, Younsuck;Lim, Chae-Man;Lee, Jae Seung;Yu, Mi Hyun;Oh, Yeon Mok;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.389-396
    • /
    • 2005
  • Background : Central venous catheters(CVCs) area major source of nosocomial infection. Chlorhexidine-silver sulfadiazine coated catheters (CHSS) were developed to reduce the rate of CVC infection. However, the clinical effectiveness of CHSS in comparison wth non-coated catheter (NCC) remains to be evaluated. Methods : From January 2004 to December 2004 in medical intensive care unit (ICU) of Asan Medical Center, CVCs were inserted in 446 cases. We retrospectively analyzed characteristics of patients and catheterization,the catheter-related infection rate and colonization, microbiologic findings, and insertion sites (subclavian, jugular, femoral) according to the type of inserted CVCs (NCC: 187 cases, CHSS: 259 cases). Catheter related infection is defined as catheter related bacteremia and catheter related non-bacteremic sepsis. Results : 1) The mean age of the patients in each group was $62{\pm}16$ years, $63{\pm}15$ years (p=0.42), and sex ratio 94:50, 141:69 (p=0.9) in NCC and CHSS. Duration of ICU admission ($29{\pm}37$, $26{\pm}44$ p=0.42), duration of mechanical ventilation ($17{\pm}22$, $15{\pm}19$ p=0.17), and APACHE III score at the time of CVC insertion ($81{\pm}34$, $82{\pm}37$ p=0.61) were not different between both groups. 2) Mean duration of catheterization was 118 in NCC and 119 in CHSS (p=0.98). Number of catheter-days was 2176 days in NCC and 3035 days in CHSS. Catheter-related infection occurred in 9 (4.8%) cases receiving NCC and 4 cases (1.5%) receiving CHSS. Catheterrelated infection incidence per 1000 catheter-days was 4.1 and 1.3, respectively (p=0.04). CHSS was associated with a significant reduction of infection in jugular catheters regarding to insertion sites (p=0.01). 3) Microorganisms causing infection were Staphylococcus aureus (n=3), Candida (n=3), coagulase-negative Staphylococci (n=2), and Klebsiella (n=1) in NCC, and Candida species (n=2), coagulase-negative Staphylococci (n=2), Proteus (n=1) in CHSS. Conclusion : CHSS has significantly reduced the episodes of infection compared to NCC in jugular catheterization in medical ICU.

The Incidences of Catheter Colonization and Central Line-Associated Bloodstream Infection According to Tegaderm vs. Chlorhexidine Gluconate (CHG)-Tegaderm Dressing (중심정맥관 번들이행에 따른 중심정맥관 균집락과 중심정맥관 관련 혈류감염: CHG테가덤과 일반테가덤 드레싱비교연구)

  • Kim, Eunji;Lee, Haejung
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.4
    • /
    • pp.541-553
    • /
    • 2020
  • Purpose: In spite of the recent application of a general infection control method, central line-associated infections is still relatively high in Korea. Central line bundle with Chlorhexidine gluconate (CHG) tegaderm dressing was reported to be effective in reducing catheter colonization and central line-associated bloodstream infections (CLABSI). Therefore, this study aimed to examine the incidences of catheter colonization occurrence and CLABSI while using Tegaderm vs. CHG Tegaderm dressings. Methods: We used a descriptive design. 400 patients who had central venous catheters were selected from four hospitals in the Korean National Healthcare-associated Infections Surveillance System. Of all subjects, 200 used Tegaderm™ (Tegaderm group), and the remaining 200 used CHG Tegaderm (CHG Tegaderm group) dressing at the catheter insertion site. Data were analyzed using the χ2 test or Fisher's exact test, t-test, and logistic regression analysis using SPSS WIN 21.0. Results: In the Tegaderm and CHG Tegaderm groups, CLABSI incidences were 5.89 and 1.79 per 1,000 catheter-days, catheter colonization incidences were 3.93 and 1.43 per 1,000 catheter-days, and central line bundle compliance rates were 26.0% and 49.0%, respectively. Catheter colonization risk factors were 'reinsertion after failure' and 'Tegaderm dressing' at the central line insertion site. CLABSI risk factors were 'incomplete performance of 7 central line bundle items' and 'Tegaderm dressing' at the central line insertion site. Conclusion: A further prospective study is needed to examine the effects of central line bundle with CHG Tegaderm dressing, avoiding central line reinsertion after failure, and improving the bundle compliance in reducing catheter colonization and CLABSI.

Impact of Central Line Insertion Bundle on the Adherence of Bundle and Central Line-Associated Bloodstream Infections in the Operating Room (수술실에서 중심정맥관 삽입 시 번들적용이 중심정맥관 관련 혈류감염에 미치는 영향)

  • Shin, Eun Jeong;Jeong, Jae Sim;Choi, Sang Ho;Huh, In Young
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.4
    • /
    • pp.257-263
    • /
    • 2016
  • Background: This study purposed to examine how the incidence of the central line-associated bloodstream infection (CLABSI) in a operating room (OR) is affected by bundle application on central line insertion (CLI) practice. Methods: The study design was a pretest-posttest experimental trial. The subjects were 83 patients before the bundle application on CLI and 70 patients after. Results: The compliance(%) of bundle on CLI of among those who observed all of the five items increased from 7.2% before the intervention to 72.9% after. By items, compliance with the maximal barrier precaution was 100% for the use of a mask and cap before and after the intervention, but increased from 73.5% before the intervention to 88.6% after for the hand hygiene, from 73.5% to 88.6% for the use of a sterile gown, and from 9.6% to 75.7% for the use of a sterile large drape covering the whole body. CLABSI did not happen on CLI either before or after the application of the bundle intervention. Conclusion: Bundle application increased compliance with the use of a sterile gown and the use of a sterile large drape. However, its effect in the prevention of CLABSI was not clear probably due to the short period of intervention in a single hospital.

Availability of peripheral inserted central catheters in severe hemophilia patients with inhibitors (중증 혈우병 항체 환자에서 시행한 말초삽입 중심혈관 카테터의 유용성)

  • Park, Youngshil
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.12
    • /
    • pp.1359-1362
    • /
    • 2008
  • The most effective treatment strategy for patients with hemophilia is replacement therapy with FVIII or FIX concentrates, which usually requires long-term, uncomplicated venous access. However, central venous access device (CVADs, ports) insertion requires inpatient admission and general anesthesia, and presents some problems regarding health insurance coverage. Peripherally inserted central catheters (PICCs) were inserted in two severe hemophilia patients aged 7 and 11 years with high titers of inhibitors. They experienced frequent bleeding episodes and required replacement therapy, which eventually resulted in difficulty in acquiring venous line access. Factor VIII activity was below 1%, and inhibitor titers were 160 and 26.3 BU/ml. In an outpatient setting, PICC lines are easily placed by radiological guidance and require local anesthesia alone. PICC has been feasible, in particular, for hemophilia patients with frequent bleeding episodes.

Factors Associated with Central Venous Catheterization in Cancer Patients (암환자의 중심정맥관 삽입 예측요인)

  • Park, Jeong-Yun;Park, Yeon-Hwan
    • Asian Oncology Nursing
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Purpose: The purpose of this study was to identify the types of venous access devices (VAD) for cancer patients and investigate the factors related to the insertions of central venous catheter (CVC) in cancer patients. Methods: The subjects were 379 cancer patients. A retrospective review of all patients who were discharged from a cancer unit from November 1st to 21st in 2008 was done using a structured questionnaire. Results: A total of 82 CVC (21.6%) was inserted among 379 patients for administering anticancer therapy. There were statistically significant differences in age, length of stay (LOS), cumulative LOS, medical department, history of CVC insertion, cancer category, and albumin level between patients using peripheral intravenous (IV) catheters and CVC. In addition, factors influencing the use of CVC were LOS (odds ratio [OR]=0.286, confidence interval [CI]=1.043-1.124), history of CVC insertion (OR=3.920, CI=0.128-0.637), albumin level (OR=1.010, CI=1.879-8.179), cumulative LOS (OR=1.010, CI=1.001-1.018), and hematological diseases (OR=4.863, CI=2.162-10.925). Conclusion: We found that central venous catheterization for anticancer therapy was minimal even though CVC was safe and effective device for IV access. It is necessary to develop a strategy to use VADs efficiently and timely for cancer patients.

Analysis of Central Line-associated Bloodstream Infection among Infants in the Neonatal Intensive Care Unit: A Single Center Study

  • Kim, Minhye;Choi, Sujin;Jung, Young Hwa;Choi, Chang Won;Shin, Myoung-jin;Kim, Eu Suk;Lee, Hyunju
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.3
    • /
    • pp.133-143
    • /
    • 2021
  • Purpose: This study aimed to determine the incidence of central line-associated bloodstream infection (CLABSI) in the neonatal intensive care unit (NICU), evaluate the patients' clinical characteristics, and identify the etiologic agents for guidance in prevention and treatment. Methods: A retrospective chart review study of infants classified as having CLABSI was conducted at the NICU of Seoul National University Bundang Hospital from January 2016 to December 2020. Results: Of the 45 infants, 53 had CLABSIs within a follow-up period of 18,622 catheter days. The incidence of CLABSIs was 2.85 per 1,000 catheter days. The most common catheter type was a peripherally inserted central catheter (n=47, 81%). A total of 57 pathogens were isolated, of which 57.9% (n=33) were Gram-positive bacteria, 36.8% (n=21) were Gram-negative bacteria, and 5.3% (n=3) were Candida spp. The most common pathogens were Staphylococcus aureus (n=12, 21%) and coagulase-negative staphylococci (n=12, 21%), followed by Klebsiella aerogenes (n=8, 14%). The median duration of bacteremia was 2 days, and 19 episodes showed bacteremia for 3 days or more. The mortality rate of infants within 14 days of CLABSI was 13.3% (n=6). Conclusions: This study analyzed the incidence of CLABSI and the distribution of pathogens in the NICU. Continuous monitoring of CLABSI based on active surveillance serves as guidance for empiric antibiotic use and also serves as a tool to assess the necessity for implementation of prevention strategies and their impact.

Effects of Maximal Sterile Barrier Precaution on the Central Venous Catheter-related Infection and Cost (중심정맥관 삽입시 최대멸균 차단법이 중심정맥관 관련 감염률과 비용에 미치는 효과)

  • Lim, Jung-Hye;Kim, Nam-Cho
    • Korean Journal of Adult Nursing
    • /
    • v.22 no.3
    • /
    • pp.229-238
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the effect of maximal sterile barrier precaution on the central venous catheter-related infection and subsequent cost savings. Methods: Study subjects were 462 hospitalized patients with central venous, catheter of more than 48 hours duration. Data collection period was from April 2008 to February 2009 at a tertiary university hospital in Seoul. Subjects were randomly assigned to either the treatment or the usual care group. Patients in the treatment group (n=209) were treated by staff using maximal sterile barrier precautions and the comparison group(n=253) received traditional care. Results: Central venous catheter-days was2,821 in treatment group and 3,515 in comparison group. The incidence density of central venous catheter-related infection was 2.1 times higher in the comparison group (8.2 per 1,000 catheter-days) compared with the treatment group (3.9 per 1,000 catheter-days). The incidence density of central venous catheter-related bloodstream infection was 4.54 times higher than in the comparison group (3.2 per 1,000 catheter-days) compared with the treatment group (0.7 per 1,000 catheter-days). The attributable cost of central venous catheter-related infection in the treatment group was 10,174,197 won and that of the comparison group was 22,224,554 won. Attributable cost by area was also significantly lower compared with that of the comparisons. Conclusion: The maximal sterile barrier precaution during central venous catheter insertion was an effective intervention to reduce central venous catheter-related infection rate and provides a significant cost savings.