• Title/Summary/Keyword: 중심보정

Search Result 491, Processing Time 0.021 seconds

Development of Geometric Calibration Method for Triple Head Pinhole SPECT System (삼중헤드 SPECT에서 기하학적 보정 기법의 개발)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Won-Woo;Park, So-Yeon;Son, Ji-Yeon;Kim, Yu-Kyeong;Kim, Sang-Eun;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Purpose: Micro-pinhole SPECT system with conventional multiple-head gamma cameras has the advantage of high magnification factor for imaging of rodents. However, several geometric factors should be calibrated to obtain the SPECT image with good image quality. We developed a simplified geometric calibration method for rotating triple-head pinhole SPECT system and assessed the effects of the calibration using several phantom and rodent imaging studies. Materials and Methods: Trionix Triad XLT9 triple-head SPECT scanner with 1.0 mm pinhole apertures were used for the experiments. Approximately centered point source was scanned to track the angle-dependent positioning errors. The centroid of point source was determined by the center of mass calculation. Axially departed two point sources were scanned to calibrate radius of rotation from pinhole to center of rotation. To verify the improvements by the geometric calibration, we compared the spatial resolution of the reconstructed image of Tc-99m point source with and without the calibration. SPECT image of micro performance phantom with hot rod inserts was acquired and several animal imaging studies were performed. Results: Exact sphere shape of the point source was obtained by applying the calibration and axial resolution was improved. Lesion detectibility and image quality was also much improved by the calibration in the phantom and animal studies. Conclusion: Serious degradation of micro-pinhole SPECT images due to the geometric errors could be corrected using a simplified calibration method using only one or two point sources.

Integrated Automatic Pre-Processing for Change Detection Based on SURF Algorithm and Mask Filter (변화탐지를 위한 SURF 알고리즘과 마스크필터 기반 통합 자동 전처리)

  • Kim, Taeheon;Lee, Won Hee;Yeom, Junho;Han, Youkyung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.3
    • /
    • pp.209-219
    • /
    • 2019
  • Satellite imagery occurs geometric and radiometric errors due to external environmental factors at the acquired time, which in turn causes false-alarm in change detection. These errors should be eliminated by geometric and radiometric corrections. In this study, we propose a methodology that automatically and simultaneously performs geometric and radiometric corrections by using the SURF (Speeded-Up Robust Feature) algorithm and the mask filter. The MPs (Matching Points), which show invariant properties between multi-temporal imagery, extracted through the SURF algorithm are used for automatic geometric correction. Using the properties of the extracted MPs, PIFs (Pseudo Invariant Features) used for relative radiometric correction are selected. Subsequently, secondary PIFs are extracted by generated mask filters around the selected PIFs. After performing automatic using the extracted MPs, we could confirm that geometric and radiometric errors are eliminated as the result of performing the relative radiometric correction using PIFs in geo-rectified images.

Analysis of the Optimal Degree and Order of Spherical Harmonics for the GNSS Receiver Antenna's PCV Correction (GNSS 수신기 안테나의 PCV 보정 모델 산출을 위한 구면조화함수 최적차수 분석)

  • Kim, Jin Yi;Won, Ji Hye;Park, Kwan Dong;Seo, Seung Woo;Park, Heung Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.113-119
    • /
    • 2014
  • The positioning accuracy of GNSS surveys deteriorates due to various error factor, and many users sometimes ignore Phase Center Variation (PCV) of antennas. IGS provides an ANTEX file which contains PCV correction information to correct for PCVs. But it is not directly applicable because PCV correction information is provided at 5-degree intervals in the azimuth and elevation directions for the case of receiver antennas, and at 1-degree intervals in the nadir angle for the case of satellite antennas. So, we devised new and optimal ways of interpolating PCV in any desired line of sight to the GNSS satellite. We used spherical harmonics fitting methods in terms of the azimuth and elevation angle for interpolation, and found an optimal degree and order. It is shown that the best accuracy was obtained from the 8 by 8 spherical harmonics. If one requires lower burden on computing resources, the order and degree less than 8 could produce resonable accuracy except for 1st and 5th order.

The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT (PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가)

  • Hong, Gun-Chul;Park, Sun-Myung;Jung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.172-176
    • /
    • 2010
  • Purpose: The patients' moves occurred at PET/CT scan will cause the decline of correctness in results by resulting in inconsistency of Attenuation Correction (AC) and effecting on quantitative evaluation. This study has evaluated the utility of reconstruction method using AC position changing method when having inconsistency of AC depending on the position change of emission scan after transmission scan in obtaining PET/CT 3D image. Materials and Methods: We created 1 mL syringe injection space up to ${\pm}2$, 6, 10 cm toward x and y axis based on central point of polystyrene ($20{\times}20110$ cm) into GE Discovery STE16 equipment. After projection of syringe with $^{18}F$-FDG 5 kBq/mL, made an emission by changing the position and obtained the image by using AC depending on the position change. Reconstruction method is an iteration reconstruction method and is applied two times of iteration and 20 of subset, and for every emission data, decay correction depending on time pass is applied. Also, after setting ROI to the position of syringe, compared %Difference (%D) at each position to radioactivity concentrations (kBq/mL) and central point. Results: Radioactivity concentrations of central point of emission scan is 2.30 kBq/mL and is indicated as 1.95, 1.82 and 1.75 kBq/mL, relatively for +x axis, as 2.07, 1.75 and 1.65 kBq/mL for -x axis, as 2.07, 1.87 and 1.90 kBq/mL for +y axis and as 2.17, 1.85 and 1.67 kBq/mL for -y axis. Also, %D is yield as 15, 20, 23% for +x axis, as 9, 23, 28% for -x axis, as 12, 21, 20% for +y axis and as 8, 22, 29% for -y axis. When using AC position changing method, it is indicated as 2.00, 1.95 and 1.80 kBq/mL, relatively for +x axis, as 2.25, 2.15 and 1.90 kBq/mL for -x axis, as 2.07, 1.90 and 1.90 kBq/mL for +y axis, and as 2.10, 2.02, and 1.72 kBq/mL for -y axis. Also, %D is yield as 13, 15, 21% for +x axis, as 2, 6, 17% for -x axis, as 9, 17, 17% for +y axis, and as 8, 12, 25% for -y axis. Conclusion: When in inconsistency of AC, radioactivity concentrations for using AC position changing method increased average of 0.14, 0.03 kBq/mL at x, y axis and %D was improved 6.1, 4.2%. Also, it is indicated that the more far from the central point and the further position from the central point under the features that spatial resolution is lowered, the higher in lowering of radioactivity concentrations. However, since in actual clinic, attenuation degree increases more, it is considered that when in inconsistency, such tolerance will be increased. Therefore, at the lesion of the part where AC is not inconsistent, the tolerance of radioactivity concentrations will be reduced by applying AC position changing method.

  • PDF

Development schemes of IoT Water Quality Metering device linked with a Drone (드론 연계 무인 IoT 수질 측정기 개발 방향)

  • Rhee, Dong Sop;Seong, Hoje
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.223-223
    • /
    • 2020
  • 하천 조사에 드론의 필요성은 점차 증가하고 있으며, 하천시설 조사 및 하천 물리량 간접 계측 등에 있어서 활용성 또한 증가하고 있다. 드론을 이용한 하천시설 및 하천 조사는 주로 광학 영상에 기초한 간접 계측을 중심으로 활발히 기술 개발이 진행되고 있으며, 최근에는 적용하는 임무장비를 확장하여 초분광카메리나 LiDAR 등을 활용하려는 시도가 활발히 이루어지고 있으며, 관련 기술의 개발도 역시 급격히 진행되고 있다. 이러한 기술 발전을 통해 하천 조사에 있어서 간접 계측의 정확도는 계속하여 증가하고 있으나, 기술의 편리성이나 활용성에 비해 정확도 향상에는 어느 정도 한계가 있으며, 간접 계측에 의한 정확도를 확보하기 위해서는 여전히 직접 계측 결과와 비교를 통한 검보정이 필수적이다. 직접 계측은 첨단 계측기를 사용한다고 하더라도 아직까지 인력에 의한 의존도가 높으며, 측정 효율이 여전히 떨어지고 있어 간접 계측의 편리성을 저하시키는 원인으로 작용하고 있다. 본 연구에서는 드론 기반의 간접 계측이 편리성 및 활용성, 정확도를 올리 수 있는 무인 IoT 수질 측정기를 개발하고자 한다. 무인 IoT 수질 측정기는 드론에서 측정한 자료 검보정 자료 획득을 목표로 하며, 드론으로 측정한 지역에 대한 데이터 검보정 정확도를 향상 시킬 수 있는 측정방안을 고려하고 있으며, 현재 이용 가능한 IoT 통신 모듈의 적용성 및 통신 거리를 고려하여 개발을 진행하고 있다. 특히 데이터 전송을 고려하여 개별 통신 규약 검토를 진행하였으며, 각종 표준을 검토하였다. 통신을 위한 전력 소모를 고려하여 저전력 통신 모듈을 중심으로 검토를 진행하였으며, 하천의 특성을 고려한 수질 측정 지점 결정을 위한 측정 알고리즘을 개발하여 적용하였다.

  • PDF

Compensation of active camera motions by using a sensor for tracking of a moving object (센서를 이용한 능동 카메라 움직임 보정 및 이동 물체 추적)

  • Youn, Su-Jin;Heo, Oh-Chul;Ahn, Jae-Hong;Park, Ki-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.119-120
    • /
    • 2008
  • 움직이는 물체 영역 검출 시 연속된 두 영상간의 차영상을 통하여 구하는 방법은 가장 간단하고 널리 사용되고 있다. 그러나 능동 카메라를 이용하여 실험할 경우 두 연속된 영상 간 배경의 움직임, 즉 카메라의 움직임 영역이 함께 포함되기 때문에 실제로 움직인 물체만을 찾아내기에는 어려움이 있다. 이를 보정하는 방법 영상의 처리를 통만 배경의 예측 및 보정, 그리고 센서를 통해 카메라가 움직인 각도를 측정하여 이를 보정해주는 방법이 있다. 본 논문에서는 팬틸트 장비에 장착된 카메라에 센서를 부착하여 각 시간 간격 당 움직인 각도를 획득, 이를 이용하여 이전 영상과 현재 영상에서의 픽셀 위치 변화 관계를 구하여 카메라의 움직임을 보정한다. 그리고 보정된 영상과 이전 영상간의 비교 통해 움직임 영역을 구하고 움직인 물체의 센트로이드를 구한다. 이때 센트로이드가 항상 이미지 플레인의 중심점과 일치하도록 팬틸트 파업을 수행한다.

  • PDF

3D Quality Improvement Method for 3DTV using Color Compensation (색상 보정을 통한 3DTV의 입체영상 화질 개선 방법)

  • Jung, Kil-Soo;Kang, Min-Sung;Kim, Dong-Hyun;Sohn, Kwang-Hoon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.220-223
    • /
    • 2010
  • 최근 연이은 3D 영화의 성공에 힘입어 영화 산업계를 중심으로 3D 콘텐츠 생성이 늘고 있으며, 이를 가정 내에서도 즐길 수 있도록 다양한 3DTV가 출시되고 있다. 그러나 3DTV의 특성 상 3D 재생 시 밝기 저하에 따른 색 재현 문제로 인하여 입체감과 공간감을 느끼는 대신 2D에서의 화려한 색감을 만끽할 수 없게 되었다. 이에 본 논문은 3D 시청 시에도 2D에서와 같은 색감을 최대한 제공하기 위한 방법에 대해 연구하였다. 이를 위하여 3DTV를 활용하여 입력 RGB 영상에 대하여 2D와 3D 재생 시 재현되는 RGB intensity를 측정한 후 입출력에 따른 관계 모델링을 실시하였고, 모델링에 근거하여 3D 재생 시 2D 대비 보정되어야 할 색상 요소에 대한 매핑 테이블(mapping table)을 생성하였다. 생성된 매핑 테이블은 기존 3DTV 시스템의 출력부에 3D 색상 보정 모듈로써 추가하도록 하여 일반 2D 재생 시에는 입력영상이 바이패스(bypass)되도록 하고, 3D 재생 시에는 본 논문에 의한 3D 색상 보정용 매핑 테이블을 통해 색상 보정 과정을 수행하도록 하여 3D 재생 시에도 2D에서 느낄 수 있는 색감을 재현할 수 있도록 하였다.

  • PDF

Automated Geometric Correction of Geostationary Weather Satellite Images (정지궤도 기상위성의 자동기하보정)

  • Kim, Hyun-Suk;Hur, Dong-Seok;Rhee, Soo-Ahm;Kim, Tae-Jung
    • Proceedings of the KSRS Conference
    • /
    • 2007.03a
    • /
    • pp.70-75
    • /
    • 2007
  • 2008년 12월에 우리나라 최초의 통신해양기상위성(Communications, Oceanography and Meteorology Satellite, COMS)이 발사될 예정이다. 통신해양기상위성의 영상데이터의 기하보정을 위하여 다음과 같은 연구를 수행하였다. 기상위성은 정지궤도상에 위치하여 전지구적인 영상을 얻는다. 영상의 전지구적인 해안선은 구름 등으로 가려져서 명확한 정보를 제공할 수 없게 된다. 구름 등으로 방해되지 않는 명확한 해안선 정보를 얻기 위하여 구름 추출을 한다. 실시간으로 기상정보를 얻는 기상위성의 특성상 정합에 전체 영상을 사용하면 수행시간이 다소 소요된다. 정합시 전체 영상에서 정합을 위한 후보점 추출을 위하여 GSHHS(Global Self-consistent Hierarchical High-resolution Shoreline)의 해안선 데이터베이스를 사용하여 211 개 의 랜드마크 칩들을 구축하였다. 이때 구축된 랜드마크 칩은 실험에 사용한 GOES-9의 위치 동경 155도를 반영하여 구축하였다. 전체 영상에서 구축된 랜드마크 칩들의 위치를 중심으로 구름추출을 수행한다. 전체 211 개의 후보점 중 구름이 제거된 나머지 후보점에 대하여 정합을 수행한다. 랜드마크 칩과 위성영상 간의 정합 중 참정합과 오정합이 존재하는데 자동으로 오정합을 검출하기 위하여 강인추정기법 (RANSAC, Random Sample Consensus)을 사용한다. 이때 자동으로 판별되어 오정합이 제거된 정합결과로 최종적인 기하보정을 수행한다. 기하보정을 위한 센서모델은 GOES-9 위성의 센서특정을 고려하여 개발되었다. 정합 및 RANSAC결과로 얻어진 기준점으로 정밀 센서모델을 수립하여 기하보정을 실시하였다. 이때 일련의 수행과정을 통신해양기상위성의 실시간 처리요구사항에 맞도록 속도를 최적화하여 진행되도록 개발하였다.

  • PDF

Systematic error calibration of 2-axis lateral shearing interferometer (2축 층밀리기 간섭계의 계통오차 보정)

  • 김승우;이혁교
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.2
    • /
    • pp.98-104
    • /
    • 2002
  • We present a new self-calibration method to remove the systematic error of a 2-axis lateral shearing interferometer that has been specially designed for optical testing of aspheric optics. The method takes multiple measurements by rotating the test optics and extracts the systematic error by fitting the measured wavefronts into the Zernike polynomials. The method works with arbitrary azimuthal angles for test optics rotation, which offers an advantage of correcting the error induced by the non-orthogonality of the two axes of wavefront shearing as well as the error caused by the optical components of the interferometer system itself.

Correction of Single Photon Emission CT Image Distorted by Collimator Characteristic (시준기의 특성으로 인한 SPECT 왜곡 화상의 보정)

  • 백승권
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2004
  • SPECT technology is used for the reconstructed image in the field of industry noncontact measurement system. One of the distortion problems in reconstructed image quality is a collimator characterictic. The image distortion is caused by a geometrical structure of the collimator. This paper indicated a correction method to remove the image distortion by the structure of the collimator, and compared with the existing correction method. The correction. method removed the image distortion to use deconvolution of projection data with the shift-variant blurring function in the frequency domain. In this pater, I simulated with the collimator angle and distance between the detector and the center of object. and verified with expeimental data. The validity and limitation of correction method is studied for actual industrial applications.

  • PDF