• Title/Summary/Keyword: 중성지

Search Result 572, Processing Time 0.022 seconds

Hyperlipidemia effect of garlic using mean difference of meta analysis (메타분석에서 평균차를 이용한 마늘의 항-고지혈증 효과)

  • Yun, A-Reum;Choi, Ki-Heon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.22 no.3
    • /
    • pp.413-421
    • /
    • 2011
  • The present study was carried out to summarize the effect of garlic in the hyperlipidemia rats by meta-analysis related studies. The association measure to test effect of garlic was the mean difference (MD). In this particular fixed-effect model of mean difference, body weight, liver weight, kidney weight and heart weight were significantly decreased (p < 0.05). Also, blood glucose, plasma total cholesterol, plasma triglycerides, LDL-cholesterol, liver cholesterol, liver triglycerides were significantly decreased. HDL-cholesterol was significantly increased. In this case of heterogeneous variable, random effect model was applied. In this model, liver weight, blood glucose, plasma total cholesterol, plasma triglycerides, LDL-cholesterol, liver cholesterol, liver triglycerides were significantly decreased. HDL-cholesterol was significantly increased. According to the meta-regression analysis, duration of injection was significantly for kidney weight, testis weight, plasma total cholesterol, plasma triglycerides, HDL-cholesterol, LDLcholesterol, liver cholesterol, liver triglycerides.

Efficacy of Acipimox in Comparison with Fenofibrate for Hypertriglyceridemia (고중성지방혈증에서 fenofibrate에 대한 acipimox의 효과 비교)

  • Kim, Seung Mi;Ji, Eunhee;Kim, Hyunah;Han, Nayoung;Shim, Mikyung;Shin, Wan Gyoon;Oh, Jung Mi
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.3
    • /
    • pp.195-201
    • /
    • 2012
  • 목적: 이상지방혈증 환자의 치료는 우선적으로 저밀도지단백을 감소시키고, 저밀도지단백이 목표수치에 도달한 이후에도 혈중 중성지방이 높을 경우 nicotinic acid 또는 fibrate를 사용하도록 권장되고 있다. 본 연구는 이상지방혈증이 있는 환자에서 acipimox의 효과를 fenofibrate와 비교하여 분석하고자 시행되었다. 방법: 본 연구는 서울에 있는 한 3차 대학병원의 환자를 대상으로 후향적으로 의무기록을 분석하여 시행되었다. 혈중 중성지방 농도가 200 mg/dL 이상으로써 acipimox 또는 fenofibrate를 신규처방 받은 환자를 대상으로 각각의 약물이 지단백에 미치는 영향을 36주간 추적하여 비교분석 하였다. 결과: Acipimox를 투여 받은 환자 41명, fenofibrate를 투여 받은 환자 62명이 모집되었으며, 각각의 약물을 복용한 환자군의 기본적인 인구학적인 특성은 유의하게 상이하지 않았다. 3개월 간의 약물투여 후 두 약물군 환자 모두에서 총콜레스테롤(p < 0.05) 및 저밀도지단백(p < 0.001)이 약물투여 전과 비교하였을 때 유의하게 감소하였고, 고밀도지단백은 모든 환자에서 유의하게 증가하였다(p < 0.05). 한편 중성지방 감소율은 acipimox군이 fenofibrate군에서보다 더 크게 나타났다(p < 0.05). 약물유해반응의 빈도는 두 약물군 간에 유의한 차이가 없었다. 결론: 총콜레스테롤, 저밀도지단백 콜레스테롤 등을 감소시키거나 고밀도지단백 콜레스테롤을 증가시키는 효과는 acipimox와 fenofibrate가 유의하게 다르지 않았으며, 중성지방을 감소시키는 효과는 acipimox가 fenofibrate보다 우월하였다.

창립 50주년 제지산업 선도해 온 한국제지-종이역사의 산 증인, 기술개발 앞장

  • Kim, Sang-Ho
    • 프린팅코리아
    • /
    • s.69
    • /
    • pp.62-67
    • /
    • 2008
  • 한국제지(주)(대표 전원중)가 지난 2월25일로 창립 50주년을 맞이했다. 지난 1958년에 설립된 이래 백상지, 아트지 등 고급 인쇄용지를 전문적으로 생산해 온 한국제지는 품질 개선과 기술 개발에 주력, 국내외에서 널리 인정받고 있는 기업이다. 또한 국내 최초라는 칭호를 자주 받은 바 있는 한국제지는 지난 1970년대부터 우표용지, 승차권 용지 등 수많은 지종을 국내 처음으로 개발했으며 1982년에는 '천년의 종이'라 불려 질 정도로 내구성이 뛰어난 '중성지' 제조기술을 국내 최초로 개발하기도 했다. 특히 1993년에는 국내 최초로 더블코팅 아트지를 개발, 생산하였으며 1994년에는 국내 제지업계에서 처음으로 ISO9002 인증을 획득하기도 했다. 21세기에 들어서도 한국제지의 기술 개발은 계속됐다. 지난 2000년에 국내 제지업계 처음으로 ERP 시스템을 구축한데 이어 2004년 8월에는 기존 아트지의 수준을 한 차원 높인 것으로 호평 받은 프리미엄(Premium) 아트지인 엑스프리(X-PRI)를 개발, 출시해 한국제지의 높은 기술력을 다시 한 번 과시했다. 창립 50주년을 맞이한 한국제지의 발자취를 아트지의 변천사와 함께 되짚어 보았다.

  • PDF

A Study on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Commercial Facility Loads (상업용 설비 부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구)

  • Kim, Kyung-Chul;Lee, Il-Moo;Paik, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.54-60
    • /
    • 2004
  • With the proliferation of nonlinear loads such as commercial facilities in all of modern society high neutral harmonic currents have been observed. High neutral currents in three-phase four-wire distribution systems can cause lots of harmonic problems. The most common solution of neutral harmonic currents reduction is a zero phase sequence filter using zig-zag transformer. This paper analyzes a commercially available neutral line zero sequence currents reduction device and applies the equipment to commercial office loads for eliminating harmonics. Experimental results m compared numerically and graphically with simulation results through the use of MATLAB.

A New Low-Cost Active Power Filter to Suppress Neutral Current Harmonics in Three-Phase Four-Wire System (3상 4선식 배전계통에서 중성선 전류 제거를 위한 새로운 저가형 능동전력필터)

  • 장민수;최세완;김기영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.359-365
    • /
    • 2002
  • Three-phase four-wire electrical distribution systems have been widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads, the neutral conductor carries excessive harmonic currents resulting in wiring failure of the neutral conductor, overloading of the distribution transformer and a voltage drop between the neutral and the ground. This paper proposes a reduced rating active power filter to suppress neutral current harmonics in three-phase four-wire electrical distribution systems. The proposed system is simple in control and the VA rating of the inverter could be significantly reduced since only the fundamental current due to unbalanced loading flows through the inverter switch. The experimental results on a prototype validate the proposed control approach.

Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode (Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Lee, Sung-Ho;Kim, Gi-Sung;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.169-174
    • /
    • 2005
  • The conventional harmonic filters to reduce zero harmonic current from neutral reactors and Zig-Zag connection, have several disadvantages of the decreased reduction rate of harmonics under a light load, because they have the load factor-dependent reduction rate of harmonics, and the risk of potential breaking in the neutral line by heated neutral reactor. Based Zig-Zag connection and Open-Delta mode, this new harmonic eliminating device (HANOS) adopts the combination of Zig-Zag connection and Open-Delta mode-the latter is additionally applied to the transformer's core block for connection to the neutral line. The results of this study demonstrated that the new device could eliminate safely zero harmonic current running in the neutral line without heating.

A Stduy on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Lighting Loads (조명부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구)

  • Kim, Kyung-Chul;Lee, Il-Moo;Jung, Yung-Ho;Paik, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.59-64
    • /
    • 2004
  • With the proliferation of nonlinear loads such as lighting facilities in all modern society high neutral harmonic currents have been observed. High neutral currents in three- phase four-wire distribution systems can cause lots of harmonic problems. The most common solution of neutral harmonic currents reduction is a zero phase sequence filter using zig-zag transformer. This paper analyzes a commercially available neutral line zero sequence currents reduction device and applies the equipment to lighting loads for eliminating harmonics. Experimental results are compared numerically and graphically with simulation results through the use of MATLAB.

The Ground Impedance Influence on Neutral Harmonic Currents (접지 임피던스가 중성선 고조파 전류에 미치는 영향)

  • Kim, Kyung-Chul;Paik, Seung-Hyun;Lee, Il-Moo;Kim, Jong-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.120-127
    • /
    • 2004
  • With the proliferation of nonlinear loads such as switching mode power supplies, high neurtral harmonic currents in three-phase four-wire distribution system have been observed. It has been known that the grounded impedance has an effect on the neutral current of a system which operates with harmonics present since the neutral conductor is grounded. On-site measurements of harmonic currents and voltages were made and the corresponding equivalent circuit was developed. The circuit model under study was simulated numerically and graphically through the use of the software MATLAB. Simulation results verifying the relationship between the neutral harmonic current and ground impedance are presented.

Effects of Chicory Root Water Extracts on Serum Triglyceride and Microsomal Triglyceride Transfer Protein (MTP) Activity in Rats (치커리 물추출물이 흰쥐의 혈청중성지질 및 Microsomal Triglyceride Transfer Protein (MTP) 활성에 미치는 영향)

  • 박채규;차재영;전병선;김나미;심기환
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.3
    • /
    • pp.518-524
    • /
    • 2000
  • 치커리 물추출물은 실험동물의 지질대사에 영향을 미치는 것으로 알려져 있으나, 이러한 영향에 대한 대사가 작은 명확하게 밝혀져 있지 않다. \ulcorner음처리한 치커리(roasted-chicory)또는 볶음처리하지 않은 치커리(unroasted-chicory)로부터 물추출한 치커리 추출물을 5% 수준으로 식이에 첨가하여 SD계 수컷흰쥐에 2주간 자유 섭취시켜 혈청 및 간장의 지질 농도와 간장 MTP(microsomai triglyceride trasfer protein) 활성에 미치는 영향을 조사하였다. 체중 증가량, 장기 중량 및 식이 섭취량은 각군잔의 유의적 차이는 인정되지 않았다. 혈당치는 대조군과 볶음처리한 치커리군에 비교해서 볶음처리하지 않은 치커리군에서 증가하는 경향을 나타내었다. 혈청의 TG 농도는 치커리 첨가군에서 감소하는 경향으로 나타났으며, 혈청 총 콜레스테롤, 인지질 및 유리지방산 농도와 간장 지질농도는 실험군간의 유의적 치이는 없었으나, HDL콜레스테롤 농도는 치커리 첨가군에서 증가하는 경향을 보였다. 간장에서 중성 지질 합성의 조절효소로 알려진 PAP(phosphatidate phosphohydrolase)활성은 각 실험 군간의 유의적 치이는 없었다. 그러나, 중성지질-rich 리포단백질의 합성, 분비에 필수적인 간장 MTP활성을 대조군에 비교하여 치커리군에서 현저하게 저해되었다. 간장 MTP 활성과 혈청 중성지질 농도의 사이에 높은 정의 상관관계(r=0.81)가 인정되어, 본 실험에서 치커리 뿌리 추출물에 의한 혈청 중성지질 억제효과는 간장 MTP 활성의 저해에 기인하는 것으로 시사되었다.

  • PDF