• Title/Summary/Keyword: 주파수 발생

Search Result 3,699, Processing Time 0.043 seconds

An Enhanced Colorwave Reader Anti-collision Algorithm in RFID System (RFID 시스템에서의 Enhanced Colorwave 리더 충돌 방지 알고리즘)

  • Lee Su-Ryun;Lee Chae-Woo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.2 s.344
    • /
    • pp.27-38
    • /
    • 2006
  • When an RFID reader attempts to read tags, interference might occur if the neighboring readers also attempt to communicate with the same tag at the same time or the neighboring readers use the same frequency at the same time. These interferences cause the RFID reader collision. When the RFID reader collision occirs, either the command from the reader can not be transmitted to the tags or the response from the tags can not be received by the reader correctly. RFID reader anti-collision algorithms have been developed to reduce it. One of the best blown reader anti-collision algorithms is the Colorwave algorithm proposed by MIT. The Colorwave algorithm reduces the reader collisions by having the readers operate at different times. In Colorwave the time is divided into frames and a frame is divided into a number of slots. Each reader can access the tags using the slot time assigned to it. Depending on the probability of the interference, the colorwave adjusts the frame size to improve the efficiency. In this paper, we analyze the operations and the performance of the Colorwave algorithm and identify the problems of the algorithm. We also show that by adding some modifications to the algorithm the performance can be improved significantly.

A Comparison Study of the Amplification Characteristics of the Seismic Observation Sites using Coda wave, Background Noise, and S-wave Energy from Fukuoka Earthquakes Series (후쿠오카 지역 발생 지진의 Coda파, 배경잡음 및 S파 에너지를 이용한 관측소의 증폭특성에 관한 비교 연구)

  • Kim, Jun Kyoung
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.435-445
    • /
    • 2013
  • Since design response spectrum does not reflect local soil characteristics, site specific response spectrum of observed ground motions appears relatively higher than design response spectrum at high frequency range. These problems have been pointed out from the domestic seismic design industry. Among various estimation methods, this study used the method H/V ratio of ground motion for estimating site amplification. This method has been extended to background noise, Coda waves and S waves recently for estimating site amplification. This study applied this method to the background noise and Coda wave energy. This study analysed more than 267 background noises from 15 macro earthquakes including main Fukuoka earthquake (2005/03/20, M=6.5) and then compared to results from S waves, at 8 main domestic seismic stations. The results showed that most of the domestic seismic stations gave similar results to those from S waves. Each station showed its own characteristics of site amplification property in low, high and specific resonance frequency ranges. Comparison of this study to other studies using different method can give us much information about dynamic amplification of domestic sites characteristics and site classification.

The three dimensional measuring system for ELF magnetic fields with the multiturn loop-type sensors (멀티턴 루우프형 센서를 이용한 3차원 ELF 자장측정계)

  • Lee, Bok-Hee;Lee, Jeong-Gee;Kil, Gyung-Suk;Ahn, Chang-Hwan;Park, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.29-36
    • /
    • 1996
  • With the three dimensional magnetic field measuring system dealt with in this paper, accurate measurements and analyses of extremely low frequency(ELF) magnetic fields caused by starting and/or operating electric devices and power installations can be conducted. To obtain high performance for lower frequency and spatial components without any distortion, the measuring system is designed as three dimensionally including the multiturn loop-type magnetic field sensors, differential amplifiers and active integrators. As the results of calibration experiments, the frequency response characteristics of the measuring system range from 8[Hz] to about 53[kHz] for each direction of x, y, z axes, and the response sensitivities are 9.54, 9.21, $10.89[mV/{\mu}T]$, respectively. The actual survey experiments by using an oscillating impulse current generator confirm a reliability of the proposed measuring system. Also, through the other experiments by using small-sized induction motors, the magnetic field intensities when starting and steady-state operating mark 15.8, $8.61[{\mu}T]$ as maximum value, respectively. And those intensities decrease steeply according as the measuring distance increases.

  • PDF

Effect of Ultrasound on the Growth and Short-term Behaviour of the Carp, Cyprinus carpio (초음파가 잉어 Cyprinus carpio의 성장 및 단기적 행동에 미치는 영향)

  • Yoon, Sung-Jin;Yeom, Dong-Hyuk;Kim, Woo-Keun;Yun, Hong-Gil;Lee, Sung-Kyu
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.244-253
    • /
    • 2007
  • In this study, mortality, body wet weight, health assessment, and short-term behavioral mode were observed to determine the effects of ultrasound on the ecological response of the carp Cyprinus carpio. Mortality in the treatments was less than 5% during ultrasound exposure (31 dB re 1 ${\mu}Pa$, $14{\sim}15$ kHz) and there were no significant differences among the replicates (P>0.05). The treatments, based on mean wet weight, exhibited greater effect than the controls, but the magnitude of the differences was not large. Skins and tail fins of some test animals exposed to the controls and intensive treatment groups had light injury such as hemorrhaging, whereas, damages in other organs such as eyes, other fins, parasites, thymus, and gills were not observed (P>0.05). Sudden stimuli in low intensity at a short distance caused a directional avoidance of the fish from the sound. However, the carp exposed to ultrasound at the large scale field was not observed clear behavior changes. Overall results suggest that fish exposed to the low-intensity ultrasound had no serious stress during the tests.

Error Budget Analysis for Geolocation Accuracy of High Resolution SAR Satellite Imagery (고해상도 SAR 영상의 기하 위치정확도 관련 중요변수 분석)

  • Hong, Seung Hwan;Sohn, Hong Gyoo;Kim, Sang Pil;Jang, Hyo Seon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_1
    • /
    • pp.447-454
    • /
    • 2013
  • The geolocation accuracy of SAR satellite imagery is affected by orbit and sensor information and external variables such as DEM accuracy and atmospheric delay. To predict geolocation accuracy of KOMPSAT-5 and KOMPSAT-6, this paper uses TerraSAR-X imagery which has similar spec. Simulation data for sensitivity analysis are generated using range equation and doppler equation with several key error sources. As a result of simulation analysis, the effect of sensor information error is larger than orbit information error. Especially, onboard electronic delay needs to be monitored periodically because this error affects geolocation accuracy of slant range direction by 30m. Additionally, DEM accuracy causes geolocation error by 20~30m in mountainous area and atmospheric delay can occur by 5m in response to atmospheric condition and incidence angle.

A Study on the EM Wave Absorber for the Electromagnetic Environment of Indoor Wireless LAN (실내 무선 LAN 전자파 환경 대책용 전파 흡수체에 관한 연구)

  • Yoon, Sang-Gil;Kim, Dong-Il;Lee, Dae-Hee;Choi, Chang-Mook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1224-1230
    • /
    • 2007
  • Recently, wireless LAN are often applied in home or office because of its various of convenience. Frequency rage of wireless LAN specified by IEEE 802.11a is at 5.2 GHz and IEEE 802.11b is 2.4 GHz. But in offices with wireless LAN devices, reflection of waves against walls, ceilings, floors and desks made of metal creates multipath problems that reduce communication speed and lose data. These problems can be solved by using EM wave absorber. In this paper, we designed and fabricated EM wave absorbers using MnZn-ferrite, sendust, carbon and CPE(Chlorinated Polyethylene). The EM wave absorber with the ratio of MnZn-Ferrite : sendust : CPE=64 : 16 : 20 wt.% has thickness of 3.7 mm and absorption ability more than 17 dB at 2.4 GHz and the EM wave absorber with the ratio of MnZn-ferrite : carbon : CPE=40 : 15 : 45 wt.% has thickness of 3.8 mm and absorption ability more than 23 dB at 5.2 GHz.

13.56 MHz Wireless Power Transfer System Using Loop Antennas with Tunable Impedance Matching Circuit (가변 임피던스 정합 회로를 갖는 루프 안테나를 이용한 13.56 MHz 무선 전력 전송 시스템)

  • Won, Do-Hyun;Kim, Hee-Seung;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.519-527
    • /
    • 2010
  • In this paper, we proposed a 13.56 MHz wireless power transfer system using loop antennas with tunable impedance matching circuits. In general, a wireless power transfer system shows an impedance mismatching due to a reflected impedance, because a coupling coefficient is varied with respect to separation distance between two resonating antennas. The proposed system can compensate the effect of this impedance mismatch owing to tunable impedance matching circuits using varactor diodes. Therefore, transmission efficiency is enhanced, moreover, the center frequency of the system is not changed, regardless of separation distance between two antennas. In order to demonstrate the performance of the proposed system, a wireless power transfer system with tunable impedance matching circuits is designed and implemented, which has a pair of loop antennas with a dimension of $30\;cm{\times}30\;cm$ cm. The input return loss, coupling coefficient, efficiency, and input impedance variation with respect to a distance between loop antennas were measured. From measured results, the proposed system shows enhanced performances than the case of the general fixed $50\;{\Omega}$ impedance matching circuits. Therefore, we verified that the proposed wireless power transfer system using the proposed impedance matching scheme will be able to ensure robust operation even when the separation distance of antennas is varied.

DEVELOPMENT OF AC SERVO MOTOR CONTROLLER FOR INDUSTRIAL ROBOT AND CNC MACHINE SYSTEM (산업용 ROBOT와 공작기계를 위한 AC SERVO MOTOR 제어기 개발)

  • Lim, Sang-Gwon;Lee, Jin-Won;Moon, Yong-Ky;Jeon, Dong-Lyeol;Jin, Sang-Hyun;Oh, In-Hwan;Kim, Dong-Il;Kim, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1211-1214
    • /
    • 1992
  • AC servo motor drives, Fara DS series, proposed in this paper can be effectively used in robots, CNC machine tools, and FA system with AC servo motors as actuators. The inverter of the AC servo drive consists of IGBT (Insulated Gate Bipolar Transistor) which have high switching frequency. Noises and vibrations generated in variable speed control of AC servo motors can be greatly reduced due to their high switching frequencies. In the developed servo drive, maximum torque is always generated in the whole speed range by compensating phase shift, which results from the nonlinearies of the AC servo motor during abrupt acceleration and deceleration. Abundant protection functions are provided to prevent abnormal state of the servo motor, and furthermore diverse user options are considered provided for the effective application. The proposed AC servo motor drive is designed to minimize velocity variation with respect to external load, supply voltage, environmental temperature, and humidity, so can be widely used in the fields of factory automation including robots and CNC msachine tools.

  • PDF

Investigation of Transonic and Supersonic Flows over an Open Cavity Mounted on Curved Wall (II) - Unsteady Flow Characteristics - (곡면상에 설치된 열린 공동을 지나는 천음속/초음속 유동에 관한 연구 (II) - 비정상 유동의 특성 -)

  • Ye, A Ran;Das, Rarjarshi;Kim, Huey Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.477-483
    • /
    • 2015
  • Investigations into cavity flows have been conducted for noise and vibration problems that arise in cavity systems. Cavity systems have been applied in engineering devices and have undergone rapid development in the aerospace industry. Meanwhile, to the author's best knowledge, the cavity on a curved wall has been seldom studied. The present work is conducted to study the flow physics of a cavity mounted on a curved wall. Numerical analysis is performed to investigate the cavity flow. Two variables of sub- and supersonic cavity flows were considered: the radius of curvature of the curved wall (L/R) and the inlet Mach number. The results show that the uniform vortex generated by the cavity flow on the curved wall stabilize the pressure fluctuation as time passes. As the inlet Mach number increases, the pressure fluctuation amplitude increases. The results obtained from the curved wall are compared with those from a straight wall using Rossiter's formula. The Strouhal number of the curved wall is lower than that of the straight wall. Lower Strouhal numbers have been obtained in the present computational fluid dynamics (CFD) results than in the theoretical results using Rossiter's formula.

Signal Analysis of Eddy Current Array Probe According to Size Variation of FBH Defects (배열 와전류 프로브의 FBH 결함 크기 변화에 따른 신호 해석)

  • Kim, Ji-Ho;Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.137-144
    • /
    • 2009
  • In this paper, the signal analysis of eddy current array probe was performed to analyze the electromagnetic characteristics with the variation of FBH(flat bottomed hole) defects size on steam generator tube in NPP(nuclear power plants) using the electromagnetic finite element method. To obtain the electromagnetic characteristic of probes, the governing equation was derived from Maxwell's equations, and the individual problem was analyzed by using the 3-dimensional finite element method. For the simulation FBH defects were used. The depth of FBH defects were 20%, 40%, 60%, 80% and 100% of steam generator(SG) tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequencies of 100 kHz, 300 kHz and 400 kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the size variation of depth of FBH defects and operation frequencies. The results in this paper can be helpful when the ECT(eddy current testing) signals from EC array probe are evaluated and analyzed.