• Title/Summary/Keyword: 주파수 검출기

Search Result 423, Processing Time 0.026 seconds

Design of Phase Locking Loopfilter Using Sampling Phase Detector for Ku-Band Dielectric Resonator Oscillator (Ku-대역 유전체 공진기 발진기의 Sampling Phase Detector를 이용한 위상 고정 루프 필터 설계 및 제작)

  • Badamgarav, O.;Yang, Seong-Sik;Oh, Hyun-Seok;Lee, Man-Hee;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.10
    • /
    • pp.1147-1158
    • /
    • 2008
  • In this paper, we designed a phase-looking circuit that locks the 16.8 GHz VTDRO to a 700 MHz SAW oscillator using SPD as a phase detector Direct phase locking with loop filter alone causes the problem of lock time, so VTDRO is phase leered by loop filter with the aid of time varying square wave current generator. The current generator is related to the loop filter and needs the systematic toning. In this paper, a systematic design of the current generator and loop filter is presented. The fabricated PLDRO shows a stabilized frequency of 16.8 GHz, a output power 6.3 dBm, and a phase noise of -101 dBc/Hz at the 100 kHz offset.

RF Capacitive Coupling Link for 3-D ICs (3-D 집적회로용 RF 커패시티브 결합 링크)

  • Choi, Chan-Ki;Cui, Chenglin;Kim, Seong-Kyun;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.10
    • /
    • pp.964-970
    • /
    • 2013
  • This paper presents a bandpass wireless 3-D chip to chip interface technique. The proposed technique uses direct amplitude modulation of the free running oscillator which especially utilizes the coupling capacitance between two stacked chips as a part of the resonator. Therefore, the oscillator is three dimensionally configured and a simple envelope detector can be used as a receiver without any additional matching circuitry. The proposed link was designed and fabricated using 110 nm CMOS technology and experimental results successfully showed the data transmission at a data rate of 2 Gb/s for the stacked chips with a thickness of 50 ${\mu}m$ consuming 4.32 mW. The sizes of the Tx and Rx chips are 0.045 $mm^2$ and 0.029 $mm^2$, respectively.

Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis (신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현)

  • Kim, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5403-5408
    • /
    • 2012
  • In this paper, we introduce the multiple frequency bio-electrical impedance analysis method for body composition analysis. And then we implement the multiple frequency bio-electrical impedance analysis system. Overall system consists of: multiple frequency alternating current signal generator contained alternating current signal, phase signal detector, voltage signal detector, micro controller, in-out device(key-pad LCD), conductivity electrodes, system power. We explain the architecture of the system and required theory to implement the system. In order to investigate the clinical significance of the body composition data, compare to the data measured by the expert body composition analyzer which provide high reproduction and precision. Finally, experimental results which are the correlation between the measured data show the very high reproduction performance of the body composition analysis in the proposed system.

CHARACTERISTICS OF THE CONTAMINATED LANGMUIR PROBE (오염된 LANGMUIR 탐침의 특성)

  • Pyo, Y. S.;Min, K. W.;Choi, Y. W.;Lee, D. H.;Kang, K. M.;Hwang, S. M.;Kim, B. C.;Kim, J.;Lee, S. J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.234-243
    • /
    • 1995
  • Korea's third rocket, which is currently under development for launch in 1997, is expected to reach as high as 160km and thus, it will provide a good opportunity for the direct measurement of the plasmas in the E-region ionosphere of the Korean peninsula. Langmuir probe techniques, which are the basic tools of the plasma experiment, may yield inaccurate results if they are applied in the conventional form as they are used in the laboratory experiments because of the contamination. In the present paper we study the contamination problem by performing the ground experiments in the vacuum chamber using the contaminated probe. The result show that the contamination effect is reduced when the plasma density is low or when the frequency of the sweep voltage is fast. We propose a modified Langmuir probe based upon our experiments which is suitable for the rocket experiments.

  • PDF

New Programmable RF DFT Circuit for Low Noise Amplifiers (LNA를 위한 새로운 프로그램 가능 고주파 검사용 설계회로)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.4
    • /
    • pp.28-39
    • /
    • 2007
  • This paper presents a programmable RF DFT (Radio Frequency Design-for-Testability) circuit for low noise amplifiers. We have developed a new on-chip RF DFT circuit that measures RF parameters of low noise amplifier (LNA) using only DC measurements [1, 2]. This circuit is extremely useful for today's RFIC devices in a complete RF transceiver environment. The DFT circuit contains test amplifier with programmable capacitor banks and RF peak detectors. The test circuit utilizes output DC voltage measurements and these measured values are translated into the LNA specifications such as input impedance and gain using the mathematical equations. Our on-chip DFT circuit can be self programmed for 1.8GHz, 2.4GHz and 5.25GHz low noise amplifiers for GSM, Bluetooth and IEEE802.11g standards. The circuit is simple and inexpensive.

Eddy Current Testing using Encircling Differential Probe for Research Reactor Fuel Rods (외삽 차동형 탐촉자를 사용한 연구로용 핵연료봉의 와전류탐상)

  • Lee, Yoon-Sang;Kim, Chang-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.561-564
    • /
    • 2001
  • The cladding area of HANARO Research Reactor fuel rods should be checked not to have any defects larger than the size required at QA documents by using eddy torrent testing method doting fabrication process. To apply eddy current testing inspection to the fuel rods, encircling differential probes and standard specimen were designed and fabricated. The impedance of the fabricated probes was measured with impedance analyzer in order to cheek that the probe has a suitable impedance for the inspection frequency, and with this probe and MIZ-40A eddy current equipment, the detectability of this probes was investigated. The developed probes could detect artificial notch with 2mm length 10% depth of cladding thickness in cladding area. In addition, the probe was successfully applied to detect the defects in cladding area doting fabrication of the research reactor rods.

  • PDF

Characteristics of Radiated Electromagnetic Waves with Partial Discharge Propagation in Model GIS Being Insulation Particle (모의 GIS 내부에 유전체 파티클 존재시 부분방전 진전에 따른 방사전자파의 특성)

  • Park, Kwang-Seo;Kim, Lee-Kook;Kim, Jong-Wan;Ju, Je-Hyun;Song, Hyun-Jig;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.69-76
    • /
    • 2005
  • In this paper partial discharge were simulated by insulation particle which could be easy accumulated charge and concentrated electric field in the model GIS. In this times this paper measured and analyzed the radiated electromagnetic waves by using spectrum analyzer and antenna$(30\~2000(MHz))$ for measurement of$ EMI{\cdot}EMC$ in accordance with occurrence and propagation of partial discharge. This paper suggested the other method of detecting and estimating of partial discharge for insulation diagnosis of GIS being insulation particle by measurement and analysis of radiated electromagnetic waves. From results of this study, it was confirmed that if the suggested method should be used for the diagnosis of insulation in the model GIS being insulation particle, detecting partial discharge and estimating discharge propagation will be possible.

Neutron Noise Analysis for PWR Core Motion Monitoring (중성자 잡음해석에 의한 PWR 노심 운동상태 감시)

  • Yun, Won-Young;Koh, Byung-Jun;Park, In-Yong;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.253-264
    • /
    • 1988
  • Our experience of neutron noise analysis in French-type 900 MWe pressurized water reactor (PWR) is presented. Neutron noise analysis is based on the technique of interpreting the signal fluctuations of ex-core detectors caused by core reactivity changes and neutron attenuation due to lateral core motion. It also provides advantages over deterministic dynamic-testing techniques because existing plant instrumentation can be utilized and normal operation of the plant is not disturbed. The data of this paper were obtained in the ULJIN unit 1 reactor during the start-up test period and the statistical descriptors, useful for our purpose, are power spectral density (PSD), coherence function (CF), and phase difference between detectors. It is found that core support barrel (CSB) motions induced by coolant flow forces and pressure pulsations in a reactor vessel were indentified around 8 Hz of frequency.

  • PDF

The Study of Space-Time Code using Z·F Detection Technique for Underwater Communication Environment (수중 통신 환경에서 Z·F 검출기법을 이용한 시공간 부호화 방식 연구)

  • Park, Tae-doo;Park, Gun-yeol;Jung, Ji-won;Kim, Beom Mu;Jeon, Sung Min;Lee, Seong-Ro
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.405-408
    • /
    • 2013
  • The performance of underwater acoustic(UWA) communication system is sensitive to the Inter-Symbol Interference(ISI) due to delay spread develop of multipath signal propagation. And due to limited frequency using acoustic wave, UWA is a low transmission rate. Thus, it is necessary technique of Space-time code, equalizer and channel code to improve transmission speed and eliminate ISI. In this paper, UWA communication system were analyzed by simulation using these techniques. In the result of simulation, the proposed Space-time code, Turbo code, and Zero forcing techniques is shown that improved performance than conventional UWA communication.

  • PDF

The defect detection circuit of an electronic circuit through impedance change detection that induces a change in S-parameter (S-parameter의 변화를 유도하는 임피던스 변화 감지를 통한 전자회로의 결함검출회로)

  • Seo, Donghwan;Kang, Tae-yeob;Yoo, Jinho;Min, Joonki;Park, Changkun
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.689-696
    • /
    • 2021
  • In this paper, in order to apply Prognostics and Health Management(PHM) to an electronic system or circuit, a circuit capable of detecting and predicting defect characteristics inside the system or circuit is implemented, and the results are described. In the previous study, we demonstrated that the frequency of the amplitude of S-parameter changed as the circuit defect progressed. These characteristics were measured by network analyser. but in this study, even if the same defect detection method is used, a circuit is proposed to check the progress of the defect, the remaining time, and the occurrence of the defect without large measurement devices. The circuit is designed to detect the change in impedance that generates changes of S-parameter, and it is verified through simulation using the measurement results of Bond-wires.