• Title/Summary/Keyword: 주차장 평가

Search Result 106, Processing Time 0.031 seconds

Development and Cost-effective Evaluation of Grass Blocks Minimizing Construction Waste (건설폐기물을 최소화한 비용 효율적 잔디 블록 기법 개발 및 평가)

  • Jeon, Minsu;Hong, Jungsun;Jeon, Jechan;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.359-365
    • /
    • 2017
  • Impermeable surfaces such as transportation land uses including roads and parking lots accumulate high heavy metals and particulate matters concentration especially during dry season which worsens the river water quality and distort the water circulation system during rainfall events. Recently, the government has been promoting policies to install Low Impact Development (LID) facilities such as permeable pavements or grass blocks in parking lots or pavements. However, transition of asphalt-paved surfaces to permeable pavement generated asphalt wastes which are detrimental to the environment and has cost implications due to its removal and disposal. Therefore this study was conducted to provide a method of constructing a cost-effective permeable pavement to reduce waste generation and cost. In this study, comparative analysis of the water circulation capacity and economic efficiency of the traditional construction method and new method proposed in this study through the lab-scale experiment. The proposed method was to make holes in existing asphalt pavements, layout geotextile fabric and permeable base media such as sand before compaction. After compaction, layout grass blocks on the compacted base media then layout sand in between each grass blocks before compaction. Apparently, there was no significant difference between the traditional installation method of permeable pavement and the proposed method in this study considering surface runoff, infiltrated volume, stored volume, and rainfall-runoff delay time. The proposed method in this study generated 86% less wastes compared to the traditional installation method and has 70% cost reduction considering asphalt removal and disposal. The construction method proposed in this study yielded similar performance compared to the traditional installation method and water circulation effect, but was proven to be less complicated and economical.

A Experiment Study for the Standard Performance and Test of Surface Finishing Material for Parking Slab (주차장 바닥용 표면 마감재의 안전성 평가 및 성능기준에 관한 연구)

  • Kim Gue-Tae;Kwon Shi-Won;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.125-131
    • /
    • 2005
  • Recently, to improve condition car park, using surface finishing material for variety color and property epoxy resin, urethane, cement mixed resin mortar or polymeric resin, and so on. However, it is frequent noise and wear out of tier and waterproofing materials, when the car slip or stop in car park, To minimize these cases, It is necessary that reduction of repair cost through performance long term durability of surface finishing material, improvement inside condition such as reduce dirty and car accident and ensurance the expected life of concrete slab in car park. Especially, we have not any tech for quality control, construction tech, production technology for car park surface materials, that's why park slab is not safety and suffer a loss. For this problems, this paper is to test surface finishing materials and as that result, suggest quality standard in the car park.

  • PDF

Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot (지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구)

  • Shin, Ju-Young;Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

SPGS: Smart Parking Space Guidance System based on User Preferences in a Parking Lot (사용자 선호도 기반의 스마트 주차 공간 안내 시스템)

  • Yoo, Seong-eun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.4
    • /
    • pp.29-36
    • /
    • 2019
  • We propose a smart parking space guiding system based on user preferences in a parking lot. This system guides each vehicle to the most suitable parking space in a parking lot to meet the user preferences such as the available parking spaces in the parking zones and the proximity to the destination by exploiting the traffic to each parking zone gathered at the sensors near each guiding display. For this purpose, this paper proposes the cost function for the optimal route guide based on the various user preferences. In addition, the paper reports the design and implementation results of an event based simulator to show the feasibility of the smart parking guidance system.

A Study on Assessment of IAQ(Indoor Air Quality) for Underground Environments in Seoul (서울시 일부 지하공간에서의 실내공기질 평가에 관한 연구)

  • 정진원;김윤신;윤동원;권성안
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.304-306
    • /
    • 2000
  • 오늘날 경제적 생활 환경의 개선으로 인하여 현대인의 생활에 많은 변화를 가져오고 있다 제한된 공간에서 인간 활동은 지하생활공간이라는 새로운 활동영역을 창출하였고, 이에 따라 실내에서의 거주 시간은 더욱 증가하고 있다. 지하생활공간이라는 용어가 일반인들에게는 다소 생소하게 받아들여질 수 있지만 여기서 말하는 지하생활공간이라 함은 불특정 다수인이 이용하는 지하철, 지하상가, 지하주차장, 지하 보·차도, 지하터널 등을 말하며 개인의 생활 양식에 따라 단시간 이용하거나 또는 생활터전으로 장시간 거주할 수 있는 공간이라고 할 수 있다. (중략)

  • PDF

The combustion test of assuming in parking space for fire resistance (지하주차장의 내화성능 평가를 위한 차량연소실험)

  • Kang, Seung Goo;Kim, Dong Jun;Lee, Jae Young;Harada, Kazunori;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

Trace Element Analysis and Source Assessment of Parking Lot Dust in Large Shopping Mall (대형유통업소주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Song, Hee-Bong;Ahn, Jeong-Eem;Jung, Yeoun-Wook;Yoon, Ho-Suk;Keum, Jong-Lok;Do, Hwa-Seok;Kim, Sun-Suk;Kim, Jong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2012
  • A total of 48 dust samples were collected from large shopping mall parking lots in Daegu metropolitan city in March 2011. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were affected by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were affected by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic trace element concentrations of ground roof dust were higher than those of ground and underground indoor dust. A large percentage of trace elements came from natural sources rather than anthropogenic sources. The percentage composition of chemicals of ground roof dust were higher than those of ground and underground indoor dust. This study showed that investigated parking lots were rarely contaminated with hazardous heavy metals. The heavy metal pollution of ground roof were higher than those of ground and underground indoors. The correlation analysis among trace elements suggest that components in ground roof were more highly correlated than those in ground and underground indoor. Also anthropogenic trace element levels were well correlated with parking lot age and parking density.

Transport and management of diffuse pollutants using low impact development technologies applied to highly urbanized land uses (고도화 도시지역에 적용된 LID 기법의 비점오염물질 관리 및 이동)

  • Geronimo, F.K.F.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.173-180
    • /
    • 2019
  • This study was conducted to understand factors affecting TSS and heavy metals transport on the road, parking lot and roof. During storm events, heavy metals, which were mostly attached to TSS, were also transported when TSS was washed off in the road, parking lot and roof. This finding may be supported by the significant correlations between TSS load and total and soluble heavy metals load including Cr, Fe, Cu, and Pb (Pearson r value: 0.52 to 0.73; probability p value<0.01). Generation and transport of TSS and heavy metals were greater in the road and parking lot compared to the roof due to vehicular activities, slope and greater catchment areas of these sites. It was found that TSS transport during peak flows of storm events ranges from 65% to 75% implying that by controlling peak flows, TSS transportation to nearby water bodies may be decreased. Depending on the target TSS and heavy metal reduction, sizing of low impact development (LID) technologies and green infrastructures (GI) such as infiltration trench, tree box filter, and rain garden may be calculated. Future researchers were recommended to assess the limitations of the systems and determine the design considerations for these types of facilities.

A Study of Management Conditions Investigation of Underground Stream in Busan and Restoration Possibility Assessment (부산시 복개하천 관리 실태조사 및 복원가능성 평가)

  • Shin, Hyun-Suk;Shon, Tae-Seok;Jang, Jong-Kyung;Shin, Dong-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2015-2018
    • /
    • 2008
  • 도시에서 하천의 모습은 시대와 함께 변화하여 왔다. 치수의 대상이 되어 제방이 높아 졌고 사람들의 생활에서 조금씩 떨어져 나왔다. 고 밀도화가 진행되는 도시지역에서 치수사업으로 하천정비를 하면서 하도의 직강화 및 콘크리트라이닝이 일반적이 되었고, 하천을 복개하여 주차장이나 도로로 이용하게 되어 도시 생태계를 단절하고 도시인들의 정서를 황폐하게 만들었다. 이에 본 연구는 부산의 23개의 복개하천 중 주요 복개하천 20개소를 선정하여 복개하천의 관리 실태조사 및 복원가능성을 평가하였다. 평가방법으로는 해당하천을 총괄지수, 제방지수, 생태지수, 하천지수로 나누어 평가함으로써 부산시내 하천평가 및 복원가능성을 제시하였다. 연구순서로는 부산시 하천을 크게 4개의 권역으로 나누고 각 하천에 대한 문헌조사, 현장조사 후 하천평가(도시하천의 하천평가기법 개발 및 적용, 2007 윤세의)를 실시하였다. 평가 결과 도시화가 많이 진행된 유역을 가진 하천 일수록 모든 지수들이 낮게 나와 하천총괄지수와 도시화의 진행정도는 밀접한 관계가 있음을 알 수 있었다. 본 연구는 도심복개하천의 기초자료로서의 활용, 복개하천의 이용실태를 파악하고 개선방안을 제시해 기초 자료로서의 활용에 목적이 있다.

  • PDF

A Low Power Parking Management System for Intelligent Building (인텔리전트 빌딩을 위한 저 전력 주차관리 시스템)

  • Lee, Chang-Ki;Im, Hyung-Kyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1479-1485
    • /
    • 2012
  • The parking management system can increase driver's convenience with detailed parking information service in the parking lot. At the same time, parking management system consumes non-negligible electrical energy with large amount of sensors, displays and control modules. With the increase in the demand for green and sustainable building design all over the world, it becomes a meaningful issue for parking management system to reduce operating power. This paper presents the preliminary design and estimated results of a parking management system which is optimized to reduce the power consumption mainly on detectors and displays. The system design is based on pre-developed wireless parking detectors, Park Tile and Park Disk. The system has a number of parking space detectors, vehicle count detectors, information displays, guidance terminals and other control units. We have performed system architecture design, communication network design, parking information service scenario planning, battery life regulation and at last operating power estimation. The estimated operating power was 0.93KW per parking-slot, which is 20% of traditional systems. The estimated annual maintenance cost was 18% of traditional systems.