• 제목/요약/키워드: 주입회전력

Search Result 11, Processing Time 0.013 seconds

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Development of the Soil Washing System for the Remediation of Oil-Contaminated Soil (유류 오염토양 복원을 위한 토양세척 공정의 개발)

  • Gong, Jun;Cho, Jang-Hwan;Lee, Ji-Hui;Choi, Sang-Il
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.60-63
    • /
    • 1998
  • 본 연구에서는 유류 오염토양 복원을 위한 효율적인 세척공정을 구성하여 현장적용 가능성을 검토하였다. 토양세척공정은 co-current식 전세척장치와 counter -current식 세척조로 구성된다. 물이 주입되는 co-current식 전세척장치에서는 스크류 축의 회전력에 의한 토양 이송 및 스크류의 각 pitch 사이에 부착된 임펠러의 기계적 교반력에 의한 세척이 동시에 이루어진다. 전세척장치를 통과한 토양과 물은 세척조로 유입되어 세척용액과 반대방향으로 이동하게 된다. 세척조의 내벽에 부착된 나선형 웨어에 의해 적정 운전조건하에서 일정 크기를 기준으로 토양이 분리되며, 각 웨어 사이에 부착된 임펠러의 교반력에 의해 오염토양이 세척된다. 실험결과, 운전시 고려해야 할 주요 영향인자들은 전세척장치에서의 토양주입량은 1 kg/min, 진탕비는 1, 회전속도는 50 rpm에서 최대 세척효율(#4-, 83.6%)을 보였으며, 세척조에서는 토양.물 주입위치 15 cm, 회전속도 5 rpm, 경사각 6$^{\circ}$, 세척용액 주입유량이 0.8 L/min일 때 최대 세척효율인 97.9%(#4-)를 나타냈다.

  • PDF

Effect of Implant Designs on Insertion Torque and Stress : Three-Dimensional Finite Element Analysis (임플란트 디자인이 식립 회전력과 응력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Kim, Jang-Eung;Choi, Yu-Sung;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.205-220
    • /
    • 2010
  • Purpose : To analyze the effect of implant designs on insertion torque and stress by performing a comparative study on von Mises stress, torque and normal force through a three-dimensional finite element analysis. Materials and methods : Models of the screw type implant were used to model the implant as a form placed in the mandibular premolar region applying a three-dimensional finite element method. Screw type implant designs were classified into 4 types of parallel ones and 7 types of tapered ones. Other factors were simulated to represent clinical environment. Results : In parallel implant designs, higher and wider threads resulted in higher insertion torques and higher stress distributions. In tapered implant designs, changes in the taper led to remarkable differences in the insertion torques. It was difficult to determine a certain tendency of stress distribution around the implants since the stress level was too high around them. In tapered implant designs, smaller implants demonstrated lower insertion torques than the original type and were relatively less dependent on the degree of taper. Tapered implants showed higher insertion torques and higher stress distributions than parallel implants. Conclusion : According to this study, although the tapered implant demonstrated a higher insertion torque than the parallel implant, stress tended to be concentrated in the entire fixture of the tapered implant due to the inefficient stress distribution.

A Treatability Study on the Soil Washing Device for the Remediation of Oil-Contaminated Soil (유류 오염토양 복원을 위한 토양세척 장비의 적용성 연구)

  • Kong, Jun;Choi, Sang-Il
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.109-116
    • /
    • 1998
  • Treatability tests of a soil washing device were performed for the remediation of eil-contaminated soil. The contaminant-containing soil with water was first fed into a oc-current screw conveyor and then into a counter-current washer. Surfactant was introduced into the washer and feeding soil was continuously separated on the basis of #40 mesh at the same time. A washing efficiency of 97.9% was achieved by the the soil washing device optimized.

  • PDF

Injection of a Denser Fluid into a Rotating Cylindrical Container Filled with Homogeneous Lighter Fluid (균질의 회전유체에 고밀도유체 주입실험)

  • 나정열;황병준
    • 한국해양학회지
    • /
    • v.30 no.4
    • /
    • pp.355-364
    • /
    • 1995
  • A heavy fluid is injected to a rotating cylindrical container of flat or inclined bottom filled with homogeneous lighter fluid. Continuous flow-in and spreading patterns over the bottom of the container are observed and at the same time upper-layer motions induced by the movement of the heavy fluid are traced by thymol blue solution. Regardless of bottom geometry, the injected denser fluid is deflected toward "western wall" and continuous its path along the boundary with radial spreading which occurs in the bottom boundary layer to make a quite asymmetric flow. When the bottom contains a slope(${\beta}$-plane), increased pressure gradient causes the fluid move faster to produce a stronger Coriolis force. This makes the width of the flow narrower than that of f-plane. But, when the denser flow reaches the southern part of the container, a local-depth of denser fluid increases (much greater than the Ekman-layer depth) such that the spreading velocity along the wall is reduced and the interfacial slope increases to make the upper-layer adjust geographically to have oppositely directed upper-layer motion along the interfacial boundary. The role of the denser fluid in terms of vorticity generation in the upper-layer is such that it produces local topographic effect over the western half of the container and also induces vortex-tube stretching which is especially dominant in the f-plane.

  • PDF

Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD (전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선)

  • Kim, Min-Choul;Shon, Byung-Hyun;Lee, Jae-Jeong;Park, Hung-Suck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.460-468
    • /
    • 2021
  • This study investigated the enhanced combustion efficiency of an "air-cooled combustion system" with single F.D. fan, and performed a numerical analysis for the operation and design conditions to increase the combustion efficiency. The combustion efficiency in an actual combustor was compared before and after the structure modification. Numerical analysis for application of a single fan revealed the difficulty of forming a turbulence for circular combustion conditions. This is because the supply ratio of combustion air supplied into 2 flow paths becomes irregular in the combustion furnace due to a change in friction force and pressure in each flow path. Subsequently, two methods of supplying air into the combustion furnace were analyzed numerically to obtain the optimal combustion conditions of an air-cooled combustion system. The first method involved injecting the preheated combustion air after a 180~360 degree rotation from the outer wall, whereas in the second method, the combustion air was injected into the combustion furnace in a tangential direction after primary heat exchange outside the combustion furnace, by applying a rotatable vane structure in the combustion furnace. Results reveal that application of a single F.D. fan to the air injection into a rotatable combustion furnace is desirable for optimization of the combustion conditions for applying a duct structure having a dual cooling wall for the cooling of the outer wall of the combustion furnace, and for maintaining perfect mixing in the combustion furnace. We therefore confirmed enhanced combustion efficiency by comparing the actual combustion efficiency before and after structure modification.

Electronical Property of BSCCO Tube Fabricated by Centrifugal Melting Process (원심 용융 성형공정으로 제조된 BSCCO 튜브의 전기적 특성)

  • Choi, Jung-Suk;Oh, Sung-Young;Jun, Byung-Hyuk;Kim, He-Lim;Hyun, Ok-Bae;Kim, Hyoung-Seop;Kim, Chan-Joong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.267-267
    • /
    • 2006
  • 전력에 큰 손실을 초래하는 고장전류를 차단하기 위한 한류기(FCL) 소재로서 고온 초전도체인 BSCCO 2212가 사용된다. 고온에서 용융된 BSCCO 2212 분말은 원심성형법에 의해 한류기용 튜브로 제조되었다. BSCCO 튜브의 기계적 특성을 높이고 용융온도를 낮추기 위해 $SrSO_4$(10wt-%)를 첨가하였다. 용탕은 $1200^{\circ}C$에서 완전히 용융되어 금속 몰드로 주입되었고 원심성형에 사용되는 금속 몰드는 $550^{\circ}C$ 온도로 2시간 예열 후 1020 ~ 2520 RPM으로 회전시켰다. 원심력에 의해 성형된 BSCCO 튜브는 약 48시간 동안 로에서 서냉 후 금속 몰드로부터 분리하였다. 튜브의 용이한 분리를 위해 이형제로서 BSCCO 2212 powder를 사용하였고 임계전류측정을 고려하여 Ag tape 단자를 튜브 끝단에 부착하였다. BSCCO 제조 공정에 있어서 몰드의 예열온도, 용융온도, 몰드 회전속도 등의 변수를 조절하여 최적의 조건을 확립하였다. 제조한 BSCCO 튜브의 임계전류($I_c$)와 임계전류밀도($J_c$)는 77K에서 536A와 $205A/cm^2$ 이었다. 본 연구에서는 BSCCO 2212 튜브를 제조하는 공정조건 변화와 각 조건에서 제조된 BSCCO 2212 튜브의 전기적 특성 및 그에 따른 분석에 대해 기술하였다.

  • PDF

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

The Estimating an Effect of Rapid Flux Increase to a Membrane in the Intermittent Aeration MBR Process Using Alum Treatment (응집제를 활용한 간헐포기 MBR공정에서 순간플럭스 증가가 분리막에 미치는 영향 평가)

  • Choi Song-Hyu;Cho Nam-un;Han Myong Su
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.70-83
    • /
    • 2005
  • By supplying air intermittently in various mode, the effects of oxic/anoxic time ratio and air scrubbing in aeration condition on the membrane flux and permeability were investigated. When suction pump stops, vacuum pressure remains inside the suction pump. Therefore, the effect of remaining vacuum pressure in the suction pump on fouling of membrane was investigated. The effect of EPS (Extra cellular Polymeric Substance) which is generated due to the long SRT and high concentration of MLSS and the dose of coagulant on the membrane were also investigated. The suitable oxic/anoxic time ratio for the best removal efficiency of organic matter and nitrogenous matter was 40 minutes (Oxic) : 20 minutes (Anoxic). At this time ratio, alum was dosed into the aeration tank. The result of dosing alum was that the concentration of alum solution might affect nitrification and denitrification. To remove 1 mg/L of phosphorus in MBR process, it needs 0.75 mg/L of alum solution.

Quality properties of texturized vegetable protein made from defatted soybean flour with different soybean seed coat contents (대두껍질 함량에 따른 탈지대두분말 식물조직단백의 품질 특성)

  • Chan Soon Park;Mi Sook Seo;Sun Young Jung;Seul Lee;Boram Park;Shin Young Park;Yong Suk Kim
    • Food Science and Preservation
    • /
    • v.30 no.5
    • /
    • pp.896-904
    • /
    • 2023
  • The texturization characteristics of textured vegetable protein (TVP) were investigated based on the extent of soybean decoating during the pretreatment of defatted soybean flour used for TVP. The raw materials for TVP consisted of 50% defatted soybean flour, 30% gluten, and 20% corn starch. The weight ratios of soybean seed coat to soybean flour were 9%, 6%, 3%, and zero. Extrusion was performed using an extruder equipped with a cooling die, maintaining a barrel temperature of 190℃ and screw speed of 250 rpm, Water was injected at a rate of 9 rpm using a metering pump. Regarding the textures of the extruded TVPs produced from defatted soybean flour, an increase in the soybean seed coat content led to a decrease in the apparent fibrous structural layer and an increase in hardness. However, there were no significant changes in elasticity and cohesion. Moreover, as the soybean seed coat content increased, the pH of TVPs decreased. A higher soybean seed coat content also tended to lower the moisture content, increasing water absorption, solids elution, and turbidity. These results suggest that an increased seed coat content reduces the proportion of protein, and the fibers present in the seed coats prevent texturization.