• Title/Summary/Keyword: 주입시험

Search Result 654, Processing Time 0.027 seconds

A Study on Improvement Effects on Fractured Rock Mass by Consolidation Grouting in Tunnel (터널 내 파쇄지반 개량을 위한 압밀그라우팅 성능 평가 연구)

  • 정교철;서용석
    • The Journal of Engineering Geology
    • /
    • v.12 no.2
    • /
    • pp.189-202
    • /
    • 2002
  • In this study we carried out the in situ test in order to explore the grouting effects of fracture zone on mechanical properties and permeability in tunnel. After consolidation grouting the rock mass averaged 2.30 in the modulus of deformation and 2.49 in the modulus of elasticity. The results obtained through this study are as follows. (1) With advance of the injection steps, the total cement take shows uniformity of the rock mass. (2) After consolidation grouting the improvement of permeability can be identified by reduction of Lugeon values. (3) Grouting injection can improve deformability and strength of rock mass. (4) More mechanical improvement appears for more deformable rock mass before grouting injection.

The Durability of Environmentally Friendly Inorganic Grouting Material(NDS) (친환경적인 무기질계 주입재(NDS)의 내구성에 관한 연구)

  • Lee, Hyejin;Lee, Jonghwi;Jung, kyoungsik;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.7
    • /
    • pp.49-56
    • /
    • 2011
  • Recently, the ground injection method using water glass as one of the components of the main resources and the products of the construction has some basic problems for permanent reinforcement of foundation and stopping leakage of water because it has some serious problems such as durability reduction, compression strength reduction and eluviation. This study was to evaluate the environmental impact and durability of the developed friendliness of Natural and Durable Stabilizer(NDS) of inorganic injection and Space Grouting Roket(SGR) with typical water glass type material. Two materials, NDS and SGR, were compared with each other by unconfined compressive strength test, fish poison test, durability test and triaxial permeability test. The results of the durability test indicated that the 28-day strength of the NDS was 1.5 times higher than that of the SGR. The fish poison test proved that the survival rate in the SGR and NDS is 50~70%, and 100%, respectively. Therefore, the NDS has higher survival rate than that of the existing SGR. The NDS will be considered by an environmentally friendly product and moreover it has a few problems for soil and groundwater pollution.

Evaluation of Grouting Effect by Injection Materials Using Geophysical Logging (물리검층을 이용한 주입재에 따른 그라우팅 효과 판정)

  • Choe, Jeong-Yeol;Park, Sang-Gyu;Im, Guk-Muk;Song, Mu-Yeong
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.98-98
    • /
    • 2010
  • 그라우팅은 지반의 공학적인 강도증가를 통한 지지력 향상 및 암반의 투수성 저감을 통해 지하수 유동을 억제하기 위하여 대규모 토목공사 현장의 균열암반 및 댐 또는 제방 등의 지역에서 많이 시행되고 있다. 본 연구는 균열암반지역에서 그라우팅 효과 확인을 위하여 보통 포틀랜드 시멘트(OPC)와 마이크로 시멘트(MC)를 사용하여 그라우팅을 수행하였으며, 그라우팅 전후에 물리검층(시추공영상촬영, 초음파 텔레뷰어검층)을 이용하여 그라우팅 효과 정도를 파악하였다. 연구지역은 경상북도 영주시 평은면 지역으로, 지질은 선캠브리아기 안구상편마암에 시대미상의 흑운모 화강암이 관입을 하였고, 이를 제4기의 충적층이 부정합으로 피복되어 있다. 그라우팅은 일반구간과 단층대구간으로 구분하여 실시하였으며, 두 구간의 이격거리는 서로의 간섭을 피하기 위해 약 40m 간격으로 선정하였다. 주입재(OPC, MC)는 5개의 주입공에서 triangle 방향으로 주입하였으며, 주입정도를 확인하기 위하여 각 구간에 2공씩 확인시추를 하였다. 두 개의 site중 일반구간의 보통 포틀랜드시멘트 주입결과 평균주입량은 48.2kg/공이며 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 1.62kg/m이며, 마이크로시멘트의 평균주입량은 49.6kg/공이며 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 3.86kg/m로 나타났다. 단층대 구간에서는 보통 포틀랜드시멘트의 평균주입량이 40.0kg/공이며, 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 2.75kg/m이며, 마이크로 시멘트는 평균주입량이 56.5kg/공, 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 3.15kg/m로 나타났다. 마이크로시멘트의 주입압은 보통 포틀랜드시멘트에 비해 상대적으로 낮았으며, 그라우팅 개선효과 역시 상대적으로 양호한 것으로 나타났다. 그라우팅 효과확인을 위한 물리검층의 초음파텔레뷰어 해석결과 상대암반강도는 주입전 $250{\sim}750\;kgf/cm^2$, 주입후는 $400{\sim}800\;kgf/cm^2$으로 그라우팅에 의한 암반강도의 상승을 확인할 수 있었고, 시추공영상촬영 분석에서는 시추코어만으로 얻기 힘든 시멘트 충진구간을 직접 확인할 수 있었다. 초음파텔레뷰어의 경우 파쇄대의 분포 및 암반강도 측정을 통한 그라우팅 파악은 가능하였으나 파쇄대 충진물을 확인할 수가 없는 단점이 있었고 이를 시추공영상촬영을 통해 보완할 수 있었다. 다만 물리검층의 경우 그라우팅에 의한 공의 손실로 동일공에 의한 반복 조사가 아닌 경우가 대부분이어서 그라우팅 효과에 대한 정확한 비교가 어려웠으며 추후 이를 보완하기 위한 계속적인 연구가 필요할 것으로 사료된다.

  • PDF

Dynamic Analysis of Driving Mechanism for Displacement Controlled Automatic Drug Injector (변위 제어형 자동 약물주입기의 구동기구 동역학 해석)

  • Shin, Young Kyu;Han, Nam Gyu;Tak, Tae Oh
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.303-311
    • /
    • 2013
  • This research deals with the analysis and design of a driving mechanism for an automatic pneumatic drug injector, which can precisely control the injection volume using a relatively simple friction-driven mechanism, without any complicated control system. Through a dynamic analysis, the effects of the design parameters of the driving mechanism associated with the geometry, spring stiffness, and fiction are analyzed, and the results are reflected in a proto-type drug injector design, which is under development for mass production. A test is performed to assess the durability of the mechanism for up to one million operations, and comparison of its displacement after one million operations, verifies the mechanism's durability.

Evaluating rheological properties of excavated soil for EPB shield TBM with foam and polymer (폼과 폴리머를 활용한 EPB 쉴드 TBM 굴착토의 유동학적 특성 평가)

  • Byeonghyun Hwang;Minkyu Kang;Kibeom Kwon;Jeonghun Yang;Hangseok Choi
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.5
    • /
    • pp.387-401
    • /
    • 2023
  • The Earth Pressure Balanced (EPB) Shield Tunnel Boring Machine (TBM) is widely employed for constructing urban underground spaces due to its minimal vibration and low noise levels. The injection of additives offers several advantages, including maintaining shield chamber pressure, reducing shear strength, minimizing cutter wear, and decreasing the permeability of the excavated soil. This technique is known as soil conditioning and involves the application of additives such as foam, polymer, and bentonite slurry. In this study, weathered granite soil commonly encountered at domestic tunnel sites was used as a soil specimen. Foam and polymer were applied as additives to assess the rheological properties of conditioned soils. The workability was evaluated through slump tests, while the rheological properties were assessed through laboratory pressurized vane shear tests conducted under the same conditions. Specially, the polymer was applied under specific conditions with low workability with high slump values, with the aim of evaluating the impact of polymer application. The test results revealed that with an increase in the Foam Injection Ratio (FIR), the slump value also increased, while the torque, peak strength, yield stress, apparent viscosity, and thixotropic area decreased. Conversely, an increase in the Polymer Injection Ratio (PIR) led to results opposite to those of FIR. Additionally, a correlation between the slump value and yield stress was proposed. When comparing conditions with only foam applied to those with both foam and polymer applied, even with similar slump values, the yield stress was found to be lower in the latter conditions.

Determining of Ground Condition Criteria for Dam Reinforced RIM Grouting (댐체 강화 RIM부 그라우팅을 위한 지반상태 기준 결정)

  • Han, Kiseung;Lee, Donghyuk;Park, Duhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.181-186
    • /
    • 2022
  • Dam slope RIM is a highly important contact interface where the main body and the base surface are connected. In general, when the grouting for the slope of the dam structure is designed, it is planned using limited data (drilling, geological map, etc.). This makes it very difficult to accurately consider the original ground characteristics of the slope RIM grouting target, In addition, when the grouting volume planned during the design is drilled and injected into the original ground where the waterstop is secured, there is a possibility that the original ground with the waterstop is disturbed and the effect of the waterstop is rather diminished. In order to overcome such problems, it is more suitable to first consider geological conditions and determine whether to perform optimal grouting on the original ground through on-site repair tests before performing RIM grouting. In this paper, to determine the grouting of the RIM unit, a pilot hole water pressure test was performed on the rock of the slope in the target section. The analysis shows grouting volume of 1 Lugeon or less, and the cement injection amount also shows the injection result of 1 kg/m or less. In this case, performing grouting is rather counterproductive. This result can be evaluated through a rock of which some degree of order of mass is secured, as it is a dam design standard of 1 Lugeon or less when analyzed, using the results of visual observation and geological map creation during slope cutting. Therefore, in conclusion, it is preferable to make the decision for using RIM grouting on the slope of the dam body structure, based on 1 Lugeon in a rock state, and the cement injection amount also at 1 kg/m.

Gas Injection Experiment to Investigate Gas Migration in Saturated Compacted Bentonite (포화 압축 벤토나이트 내 기체 이동 현상 관측을 위한 기체 주입 시험)

  • Jung-Tae Kim;Changsoo Lee;Minhyeong Lee;Jin-Seop Kim;Sinhang Kang
    • Tunnel and Underground Space
    • /
    • v.34 no.2
    • /
    • pp.89-103
    • /
    • 2024
  • In the disposal environment, gases can be generated at the interface between canister and buffer due to various factors such as anaerobic corrosion, radiolysis, and microbial degradation. If the gas generation rate exceeds the diffusion rate, the gas within the buffer may compress, resulting in physical damage to the buffer due to the increased pore pressure. In particular, the rapid movement of gases, known as gas breakthroughs, through the dilatancy pathway formed during this process may lead to releasing radionuclide. Therefore, understanding these gas generation and movement mechanism is essential for the safety assessment of the disposal systems. In this study, an experimental apparatus for investigating gas migration within buffer was constructed based on a literature review. Subsequently, a gas injection experiment was conducted on a compacted bentonite block made of Bentonile WRK (Clariant Ltd.) powder. The results clearly demonstrated a sharp increase in stress and pressure typically observed at the onset of gas breakthrough within the buffer. Additionally, the range of stresses induced by the swelling phenomenon of the buffer, was 4.7 to 9.1 MPa. The apparent gas entry pressure was determined to be approximately 7.8 MPa. The equipment established in this study is expected to be utilized for various experiments aimed at building a database on the initial properties of buffer and the conditions during gas injection, contributing to understanding the gas migration phenomena.

The Experimental Study on Electrokinetic Injection Improvement of Low Permeable Ground (저 투수성 지반의 동전기 주입 개량의 실험 연구)

  • Kim, Soo-Sam;Han, Sang-Jae;Kim, Ki-Nyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2C
    • /
    • pp.99-108
    • /
    • 2006
  • In this study a series of bench scale test are conducted to increase the undrained shear strength of clayey soils using by Electro-kinetic injection stabilization method. The sodium silicate was injected in anode reservoir and its concentration was changed with 500, 1000, 1500, 2000, 2500mM for configuration of applicability of Electro-kinetic injection stabilization method. Also, the treatment time and electric gradient was changed to acquire the optical influence factors. For increasing the shear strength to maximum values, the calcium chloride and aluminium hydroxide, which concentration was changed with 50, 250, 500, 750, 1000mM, were added at anode reservoir for 5 days after the treatment of sodium silicate in 5 days as the 2nd additives. The test of results in determination of sodium silicate concentration show that the undrained shear strength at each point had a tendency to converge into a constant value when the concentration of sodium silicate came to 1000mM and above. The maximum shear strength increasement was 800% compared with initial value. After a series of test, the electric gradient and treatment time for application of electric fielld were 1V/cm and 6 days. In case of 2nd additives test, the concentration for maximum shear strength is 250mM in all additives and the effects of shear strength improvement was developed approximately 20~30% in comparison to addition of single injection material.

Development of Packer-Dilatometer Method (팩커를 이용한 공내재하 시험 방법 개발)

  • Kern Shin Yoon
    • The Journal of Engineering Geology
    • /
    • v.8 no.2
    • /
    • pp.189-203
    • /
    • 1998
  • Packer-dilatometer techniques, which are borehole-dilatometer techniques using commercial rubber packer, were developed to measure the deformability of rocks. Packer-dilatometers for 0.5 inch, AX, BX, NX and HX size boreholes were developed and were used for rock deformability measurements in the field. In the packer-dilatometer method, the packer pressurizes the borehole-wall and the borehole deformation is determined by the amount of fluid injected into the packer. A detailed description of the theoretical development of quantitative interpretation of the packer-dilatometer method; apparatus, setup and procedures for the determining of calibration constants; contact pressure determination and field tests using the packer-dilatometer are provided.

  • PDF

Test and Evaluation of Liquid Mono-propellant Thruster (단일액체추진제 추력기 성능 시험평가)

  • 김정수;한조영;이균호;장기원
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.61-64
    • /
    • 2003
  • A comprehensive understanding is given for the hot-firing test results, which were obtained throughout the verification program of mono-propellant hydrazine thrusters producing 0.95 lbf (4.2 Newtons) of nominal steady-state thrust at an inlet pressure of 350 psia (2.41 ㎫). The scrutiny is made in terms of thrust and temperature behavior of steady state firing mode at the given propellant injection pressures of 400, 250, 100, and 50 psi. Engineering philosophy of data measurement and reduction is shortly mentioned, too.

  • PDF