• Title/Summary/Keyword: 주입모형실험

Search Result 95, Processing Time 0.023 seconds

A Study on Isothermal Adsorption of VOCs onto Gypsum Mortar Incorporating Oyster Shell (굴패각 모르타르에의 휘발성 유기화합물 흡착에 대한 연구)

  • Kwon, Sung-Hyun;Cho, Daechul
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.134-139
    • /
    • 2013
  • VOCs such as formaldehyde and benzene in a control chamber were adsorbed onto gypsum incorporating oyster shell powder, which was solidified and dried. VOC was first exposed in air and then gypsum mortar was placed in the chamber for 180 min for adsorption. The mortar was prepared with 0, 10, 30, and 50% of oyster shell powder. Two initial concentrations of VOCs including formaldehyde were $27.7{\sim}28.5mg/m^3$ or $175{\sim}150{\mu}g/m^3$. We found out that the initial concentrations did not seem to make any difference in adsorption performance but higher oyster content strongly led to higher adsorption. We used a convection-diffusion-adsorption model to compare the experiment. The model which considers diffusion coefficients of adsorbates and affinity of the adsorbents well represented the experimental data with a fair agreement.

Using a 7.0T animal MRI comparison of ADC values and Pathologic Findings (7.0T 동물용 MRI을 이용한 종양의 현성확산계수와 병리학적 소견의 평가)

  • Seong, jae gu;Lim, cheong hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.201-202
    • /
    • 2011
  • 본 연구에는 7.0T 동물용 자기공명영상장치를 이용하여 인간의 췌장암 세포인 CFPAC-1를 이종 이식한 쥐에서 자기공명영상을 획득하여 최적화된 검사 Protocol을 정립하며, 동물 실험에서 밝혀진 종양특성과 확산강조영상과의 비교 분석을 해보고 현성확산계수 영상이 췌장암 이종이식 모형의 종양 세포 내부 구조에 관하여 어떠한 정보를 제공 할 수 있는지 알아보고자 한다. 13마리의 쥐의 26개의 종양을 전형적으로 주입 후에 2~4주 뒤에 직경이 5~10mm가 되었을 때 imaged 하였으며, pathologic specimenm을 위해 sacrificed 하였다. isofluoran gas anesthesia를 이용하여 동물 마취 하였다. 사용된 장비로는 small-animal MR images (7.0-T)를 (Bruker BioSpin GmbH, Rheinstetten, Germany)이용하여 Fast T2-weighted 와 single-shot EPI DW image를 얻었다. 종양은 H&E 염색과 CD31와 VEGF에 대한 면역조직학 염색을 하여 종양의 cellularity와 microvessel density(MVD), 종양 내 괴사 정도를 평가하였다. CFPAC-1의 현성확산계수값은 $0.7327{\pm}0.1075{\pm}10^{-3}mm2/s$이였으며, 현성확산계수는 종양내 괴사 정도와 연관성을 보였다(R = 0.7417, p = 0.0001) 이처럼 현성확산계수는 종양 내 괴사 정도 등의 현미경적구조변화를 반영하는 대리인자로 사용될 수 있음을 확인하였다.

  • PDF

Dynamic Characteristic Analysis of 3-Level Half-bridge SSSC (3-레벨 반브리지로 구성된 SSSC의 동특성 분석)

  • 박상호;하요철;백승택;김희중;한병문
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.317-324
    • /
    • 2001
  • This paper proposes a SSSC based on 3-level half-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-but power system. The proposed SSC has six 3-level half-bridge inverters per phase, which operates in PWM mode. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF

Beach Deformation Mechanisms in Haeundae Beach (해운대(海雲臺) 해수욕장(海水浴場)의 해빈변형기구(海濱變形機構))

  • Lee, Jong Sup;Park, II Heum;Kim, Cha Kyum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.595-605
    • /
    • 1994
  • The field observations. data analyses and numerical experiments are performed to investigate the short and long term beach deformation mechanisms in Haeundae beach. The schematic diagrams of deposition and erosion mechanism due to the attack of typhoons are described from the analysis on the beach widths and profiles. The short term beach deformation depends strongly on the characteristics of incident waves and wave-induced currents. The main incident wave and the calibration parameters of the shoreline change model are determined using the beach width data. Beacause the main incident wave approaches obliquly from the SE direction, the net westward longshore sediment transport occurs. Therefore the unbalance of longshore sediment budget in the east of the beach where the sediment source dose not exist causes a beach erosion. On the other hand, the deposited sand in the west is lost offshore by the storm wave action.

  • PDF

Pullout Characteristics of Pressure Reinjection-Grouted Reinforcements in Decomposed Granite Soil (화강풍화토 지반에 설치된 압력재주입 그라우팅 보강재의 인발특성)

  • Shim, Yong-Jin;Lee, Jong-Kyu;Lee, Bong-Jik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.61-68
    • /
    • 2012
  • Most widely methods for reinforcement of soil utilized in Korea are anchor method, soil nail method and micro pile method. These methods are classified by the intended use of the structure to be constructed, but the reinforcement of the ground is accomplished contains in common the process of grouting work after inserting the reinforcements. Domestically, gravity grouting has been used mostly so far, but there has always been the risk of insufficient restoration of the loose ground area from the drill holes because the grouting is conducted only by gravity. On the other hand, pressure reinjection grouting may enhance the grouting quality by solving the problem of the existing grouting method considerably since it additionally reinjects grouting through pre-installed tube a certain time after the first grouting. Accordingly, this study evaluated the pullout characteristics by the grouting methods by performing model test on decomposed granite soil, and investigated the support increasing characteristics of reinforcements depending on the curing time, reinjection pressure, and uplift force variation of the pressure reinjection grouting. The result of this research shows that the pressure reinjection grouting demonstrated 1.1~1.3 times of performance of the gravity grouting, and suggests some analysis on optimal water content, reinjection pressure and curing time of the pressure reinjection grouting.

Mechanical and Hydraulic Stabilizing Method of Steel Pipe Propulsion Tunneling Using Liquid Nitrogen (액체질소를 이용한 강관압입공법의 역학적 수리학적 안정화공법)

  • Ji, Subin;Lee, Kicheol;Lee, Ju-hyung;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.3
    • /
    • pp.57-66
    • /
    • 2016
  • In this study, to prevent possible collapse caused by hydraulic or mechanical instability, liquid nitrogen injection method is developed and implemented at the tip of drilling auger of steel pipe propulsion tunneling. In this study, 1/5-scale model auger and sand chamber were manufactured. The prototype diameter of steel pile (or casing) is assumed about 1,000 mm. For the frictional sandy soils and plastic weathered soils, liquid nitrogen injection methods were tested varying water contents of the soils. For the induced hydraulic instability, the ground near the drilling auger was frozen within approximately 5 minutes preventing mechanical collapse and water infiltration. Securing stability of steel pile propulsion tunneling using liquid nitrogen was much more effective for which the water content of the soil somewhat exceeds the optimum water content.

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Injection Effects of Coagulant and Flocculant on Bulking Change of Dredged Soils (준설토 체적변화에 대한 응집제 및 응결제의 주입효과)

  • 윤길림;유승경
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.257-264
    • /
    • 2003
  • Bulking change between sediments and dredged soils occurs when dredged soils are fully disturbed by dredging process and settled down to stabilized conditions in the basin. Bulking of dredged soils are affected by chemical injection, coagulant and flocculant, to speed up settling process of the suspended solids. In this paper, bulking changes of dredged soils are investigated by experimental works regarding injection effects of the coagulant and flocculant. Dredged sediments were sampled in the lagoon located at the East Coast, and the bulking change of dredged soils is quantitatively analysed by changing the clay content and the amount of the coagulant and flocculant. The optimal amounts of the coagulant and flocculant are determined based on minimal bulking change due to coagulant and flocculant injection. From the experimental results, the bulking of dredged soils increased 1.69 times on the average and the bulking change rate slightly increased as clay content increasea due to injection of the coagulant and flocculant.