• Title/Summary/Keyword: 주위온도에 따른 오차

Search Result 8, Processing Time 0.027 seconds

A Signal Processing Software Technique for the Tolerance of the 4 Axis Strain-gauge Sensors applied to the Military Weapon System (군 무기체계에 적용되는 4 축 스트레인-게이지의 오차에 대한 신호처리 소프트웨어 기법)

  • Young-Jun Lee;Chong-Ho Yi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.185-194
    • /
    • 2023
  • The 4-axis strain-gauge, which is widely applied to military weapon systems, is operated in poor temperature and vibration conditions, tolerance may increase and malfunctions may occur. To improve this, this paper proposes a signal-processing software technique for the tolerance of the 4-axis strain gauge applied to a military weapon system. First, the tolerance of the strain-gauge and the signal processing circuit according to the ambient temperature were evaluated and analyzed. Second, a software technique for processing the dead zone and offset area that can improve the tolerance of the strain-gauge is proposed. The experimental results applying the software technique confirmed that it operated normally in the temperature test and operation test. Therefore, the proposed software technique is valid and can be used as useful information to improve tolerance due to ambient temperature and vibration when designing a system using a strain-gauge.

Development of Laser Power Measurement System for Wide Power Range (광범위 측정이 가능한 레이저 출력 측정 장치 개발)

  • 황대석;최종운;신동주;정영붕;김용완;이영우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.212-213
    • /
    • 2000
  • 레이저 칼로리미터는 측정하려하는 레이저 에너지를 수광부에서 받아들여 열로 변환한 후 온도상승을 열 기전력으로 바꾸어 측정하는 장치이다. 레이저 칼로리미터는 정밀도도 높고, 레이저 광에 대한 파장의존성이 작으며 주위 온도등 환경의 변화나 시간경과에 따른 오차가 작아 폭 넓게 사용된다$^{(1)}$ . (중략)

  • PDF

이동열원을 고려한 CNC공작기계의 열오차해석 및 보정

  • 이재종;양민상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.283-287
    • /
    • 1997
  • 공작기계의 가공정도는 공작기계의 운동기구가 가지고 있는 기하오차와 절작작업시 발생하는 진동, 열,절삭력에 의해서 공작기계의 구조계,주축계,이송계의 변형에 의해서 직접적인 영향을 받는다. 또 가공정도는 제품의 정밀도 및 품질에 직접적인 영향을 미치기 때문에 가공정도를 향상시키기 위한 방법으로 공작기계의 오차를 측정/해석하는 방법이 연구되고 있다. 일반적으로,공작기계의 오차는 Quasi-static 오차와 Dynamic오차로 구분할수 있다. Dynamic 오차는 기계의 진동,채터 및 스핀들의 진동에 의해서만 발생하는 오차이며,Quasi-static 오차는 공작기계 구성요소인 안내면,칼럼,볼스크류등의 기하오차와 온도변화에 의한 열변형오차에 의해서 발생한다. 특히,공작기계 및 절삭가공중에 발생하는 열원에 의한 열변형 오차는 공작기계의 기하오차에 비해서 가공정도에 큰 영향을 미치며[1,2],발생오차의 약 40~70% 정도가열변형 오차에 기인한 것으로 알려져 있다[1]. 실제 많은 실험결과를 볼 때 CNC공작기계이 경우는 열변형에 의한 오차는 기하오차에 비해서 매우 크게 나타났다. 이러한 열변형 오차는 공작기계 주위 온도와 공작기계 구성요소(칼럼,이송유니크,스핀들유니트)의 비선형적인 온도 특성에 의해서 주로 발생하고, Time-variant특성을 가지고 있기 때문에 작업중에 발생하는 온도특성에 따른 열변형 오차를 최소화 할 수 있는 방법이 필요하다. 스핀들유니트는 냉각방식을 사용하여 온도변화를 줄이고 있으나 반복적인 작업과 스핀들의 고속회전으로 인해서 복합 적인 온도변화를 발생시킨다. 또, 볼스크류의 지지방식이 양쪽 고정단 형태이기 때문에 조립시 예압(pre-load)을 주어서 열팽창을 보상하고 있으나 공작기계의 반복적인 이송으로 인해서 발생하는 온도변화에 의한 열오차를 보상하는데는 어려움이 있다.됩니다. 생리적 저항력이 없는 어린이들은 이러한 공해와 생활조건의 제일희생자가 되는 것입니다. 엄마들이 "얘는 감기, 비염, 편도선을 달고 삽니다...." "얘는 코감기, 목감기 번갈아 가면서 하도 앓고 있어서 양약율 중지하고 현재 한약을 먹고 있습니다." 이러한 역경은 극복할 수 있는가\ulcorner 질병의 메카니즘은 어떻게 작용되는가\ulcorner 등등을 육미회 센타에서 체험한 사례를 가지고 말씀드리고자 합니다..ell layer (PCL)와 glia에 SOD-1이 강하게 염색되었다. APT 병용 투여로 상당수의 경련이 일어나지 않은 흰쥐는 해마의 DG에 FRA가 경미하게 염색되었고, PCL에 SOD-1도 경미하게 나타났으나, 경련이 나타난 쥐에서는 KA만을 투여한 흰쥐와 구별되지 않았다. 이상의 APT의 항산화 효과는 KA로 인한 뇌세포 변성 개선에 중요한 인자로 작용할 것으로 사료되나, 보다 명확한 APT의 기전을 검색하고 직접 임상에 응응하기 위하여는 보다 다양한 실험 조건이 보완되어야 찰 것으로 생각된다. 항우울약들의 항혈소판작용은 PKC-기질인 41-43 kD와 20 kD의 인산화를 억제함에 기인되는 것으로 사료된다.다. 것으로 사료된다.다.바와 같이 MCl에서 작은 Dv 값을 갖는데, 이것은 CdCl$_{4}$$^{2-}$ 착이온을 형성하거나 ZnCl$_{4}$$^{2-}$ , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어떠한 용리액에서던지 NH$_{4}$$^{+}$의 경우 Dv값이 제일 작았다. 바. 본 연구

The Characteristic Change of Pressure and Differential Transmitter due to a Rapid Change of Ambient Temperature (주위 온도의 급격한 변화에 따른 압력 및 차압 전송기의 특성 변화)

  • Chung, Jong-Tae;Ha, Young-Cheol;Lee, Cheol-Gu;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.321-326
    • /
    • 2004
  • The pressure and differential pressure(DP) transmitters are used for gas flow rate calculation on the orifice gas metering system. On site, the pressure and DP transmitters are installed in a shelter to diminish the affects of environmental change such as an ambient temperature. But there has been an argument about the effectiveness of the shelter and this brought up the necessity to verify the affects of ambient temperature. These experiments were performed to verify the ambient temperature effects as observing the output of transmitters when the ambient temperature were changed from $-30^{\circ}C$ to $50^{\circ}C$. The results showed that the most of transmitters were operated in the spec range of performance criteria presented by manufacturer but the rapid change of ambient temperature could cause the larger measurement error for the DP transmitter of low span than others. Therefore the pressure and DP transmitters need to be operated and controlled within the proper range of ambient temperature.

  • PDF

Analytical and Numerical Model Study to Predict the Temperature Distribution Around an Underground Food Cold Storage Pilot Cavern (냉동저장 공동 주변의 온도분포 예측을 위한 해석해 및 수치모델 적용에 관한 연구)

  • 이대혁;김호영
    • Tunnel and Underground Space
    • /
    • v.12 no.3
    • /
    • pp.142-151
    • /
    • 2002
  • Claesson(2001)'s analytical solution, and two numerical models with Dirichlet and Neuman interior boundary condition respectively were investigated to estimate the transient temperature distribution with distances from the Taejon underground food cold storage pilot cavern. Claesson's solution, which is based on constant temperature boundary condition at the rock wall during a temperature decline step, showed relatively good agreement with temperature measurements in the rock mass in order of average error difference, 0.89$\^{C}$ without any adjustments on laboratory thermal properties to represent the rock mass. For the numerical model with heat flux through the rock wall, a boundary condition setting technique was newly proposed to overcome the difficulty of prescribing variable convective heat tranfer coefficient and far-field air temperature inside the cavern as they may be certainly changed according to the cooling-down time. The results showed also good agreement with measurements in order of average error difference, 1.58$\^{C}$, and were compared to those of the numerical model with fixed temperature at the rock wall. Finally, the most proper procedure to precisely predict the temperature profile around a cavern was proposed as a series of analysis steps including an analytical exact solution and numerical models.

Chromatic adaptation model for the variations of the luminance of the same chromaticity illuminants (동일 색도 광원의 휘도 변화에 따른 색 순응 모델)

  • Kim Eun-Su;Jang Soo-Wook;Lee Sung-Hak;Sohng Kyu-lk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.4 s.304
    • /
    • pp.31-38
    • /
    • 2005
  • In this paper, we propose the chromatic adaptation models (CAM) for the variations of the luminance levels. A chromatic adaptation model, CAM$\Delta$Y , is proposed according to the change of luminance level under the same illuminants. The proposed model is obtained by the transform the test colors of the high luminance into the corresponding colors of the low luminance. In the proposed model, the optimal coefficients are obtained from the corresponding colors data of the Breneman's experiments. In the experimental results, we confined that the chromaticity errors, $\Delta$u'v', between the predicted colors by the proposed model and the corresponding colors of the Breneman's experiments are 0.004 in u'v' chromaticity coordinates. The prediction performance of the proposed model is excellent because this error is the threshold value that two adjacent color patches can be distinguished. Additionally, we also propose equal-whiteness CCT curves (EWCs) by CAM$\Delta$Y according to the luminance levels of the surround viewing conditions. And the proposed EWCs can be used as the theoretical standard which determines the reference white of the color display devices.

A Study on Heat Transfer Characteristics for Cross Flow Heat Exchanger of Staggered Arrangement (어긋나기배열 직교류 열교환기의 열전달특성에 관한 연구)

  • Yoo, Jae-Hwan;Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1016-1023
    • /
    • 2012
  • Because heat exchanger consists of many circular tubes, the analysis of local heat transfer and pressure drop at the surrounding of circular tubes, performance and calculation of size, economics play important roles in design. In this study, This study conducted experiment and analysis in order to observe convective heat transfer coefficient LMTD (logarithm mean temperature difference) and pressure losses according to water temperature and air flow rate using a cross flow heat exchanger of staggered arrangement. This heat exchanger was composed of staggered arrangement for five rows and seven columns of tube banks, and the condition of experiment and analysis are $40{\sim}65^{\circ}C$ of water temperature and $5.0{\sim}12.3m^3/s$ of air flow rate. As a result of it, since air density decreases as water temperature and flow rate increases, Reynolds number decreases with characteristics of low flow velocity but mean heat transfer coefficient increases with air flow rate increase, heat transfer performance has been improved and pressure losses decreased. And since heat transfer rate shows about 8~12% and pressure drop around 0.01~7.5% error as the analysis result, the feasibility of this study could be evaluated.

EF-TEM을 이용한 직접가열 실험을 통한 Titanium의 고온에서의 상변화 연구

  • 김진규;이영부;김윤중
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.22-23
    • /
    • 2002
  • Titanium은 높은 강도, 낮은 밀도, 부식에 대한 저항 등, 타 금속에 비해 월등히 뛰어난 성질을 가지고 있기 때문에 산업 전반에 거쳐 그 응용이 크게 증가하고 있으며, 특히 고온에서의 응용이 중요성을 띠게 됨에 따라 고온으로의 상전이 관계에 따른 구조적 규명이 필요하다. 순수한 titanium은 상온에서 조밀충진 육방정계의 α-상구조(a=2.953Å, c=4.683 Å, P6₃/mmc)를 이루고 있으나, 대략 880℃ 이상에서는 β-상의 체심입방정계 (a=3.320Å, Im3m)로 상전이가 되는 것으로 알려져 있다. 이에 대한 대부분의 연구가 kinetics와 thermodynamics에 관련되어 있으며, TEM을 이용한 직접가열실험은 거의 전무한 상태이다. 본 실험에서는 TEM 직접가열을 통하여 titanium의 고온에서의 상전이와 가열시 발생할 수 있는 산화층 형성을 연구하였다. TEM 시편은 순도 99.94%의 titanium foil(Alfa Aesar, #00360, 0.025mm thick)를 이용하였고, 분석 장비로는 에너지여과 기능이 있는 TEM(EM912 Omega, Carl Zeiss)과 Gatan사의 double-tilt heating holder를 사용하였다. Titanium의 상전이를 관찰하기 위해 900℃ 까지 분당 10℃ 의 속도로 가열을 하였다. 통계적 분석 오차를 줄이기 위해 서로 다른 4군데의 관찰영역을 선택하여, 상온 - 600℃ - 900℃ - 상온의 단계별로 회절패턴을 관찰 및 기록하였고, 발생 가능한 산화에 대해서는 동일한 장비를 사용하여 EDS 분석을 하였다. 상온에서의 서로 다른 영역의 회절패턴들은 결함의 존재에 상관없이, 온도가 증가함에 따라 그 결함수가 증가하게 된다. 특히 600℃ 에서는 쌍정과 관련된 회절점들이 본래의 회절점 주위에 형성되어있지만, 각 면들의 격자상수의 변화는 나타나지 않았다. 그러나 900℃ 에서는 쌍정에 의한 회절점의 수가 증가하며, 회절점 사이에 발달한 뚜렷한 막대모양의 강도분포와 격자상수의 변화를 관찰할 수 있었다. 다시 상온으로 냉각시킨 후 관찰한 각각의 회절패턴에서는 격자 상수의 감소와 함께 900℃에 보여진 막대 모양의 강도분포와 쌍정에 의한 회절점들이 여전히 남아있었다. EDS분석 결과 가열 실험을 통해 시편이 열적 산화가 되어 있음을 확인 할 수 있었다. 순수한 titanium의 α-상에서 β-상으로의 상전이를 파악할 수 있는 격자상수의 변화자체는 매우 작은 값이기 때문에 상온과 900℃ 에서 기록된 전자회절패턴 상에서의 면간거리와 면간각도의 측정만으로는 상전이 여부를 명확히 구별할 수 없었다. 그러나, 결함에 의한 상변화가 900℃ 에서 심하게 관찰되어지는 것은 상전이와 관계가 있는 것으로 볼 수 있다. 고온에서 상온으로의 가역적 반응을 관찰할 수 없었던 이유는 열적산화로 생긴 산화층의 산소원자들이 고온의 상전이 과정 중에 Ti 원자와 반응이 일어나 TiO/sub X/ 구조로 전이되었기 때문으로 추정하고 있다.

  • PDF