• Title/Summary/Keyword: 주상복합 건축물

Search Result 54, Processing Time 0.023 seconds

A Study on the Seasonal Performances Evaluation of the Horizontal-type Geothermal Heat Exchanger Installed in the Foundation Slabs of Complex Building (주상복합 건축물의 기초 슬래브에 설치된 수평형 지열교환기의 계절별 성능평가)

  • Hwang, Kwang-Il;Woo, Sang-Woo;Kim, Joong-Hun;Shin, Seung-Ho;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2007
  • This study evaluates the seasonal performances of the horizontal-type geothermal heat exchanger(HGHEX) installed into the foundation slabs of the complex building located at Seoul. The geothermal system is consisted with totally 31,860m long HGHEX, 16 GSHPs (Ground-source Heat Pump) and 8 circulation pumps. This system supplies cooling and heating to the lobby(F1) and the common spaces(BF1). The average heat exchange temperature differences are $2.7^{\circ}C\;and\;2.5^{\circ}C$ in the summer, $1.5^{\circ}C\;and\;0.5^{\circ}C$ in the winter for the F1 and BF1 respectively. From these results, approximately 400Gcal and 180Gcal of geothermal energy are assumed to have been used during the summer and winter seasons respectively. As a conclusion, the geothermal system is reviewed as a effective utility for heating and cooling at the point of seasonal performances.

A Study on the actual condition of Housing Buildings in the Urban area (도시지역 주거관련 건축물의 사용실태에 관한 연구)

  • Kim, Sung-Hwa;Lee, Jae-Hoon;Kim, Yeung-Bean
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.57-61
    • /
    • 2005
  • The objectives of this study are to illustrate an alternative housing type responding to the social requirements and customers' needs, to suggest the improvement plan for the related laws and regulations through survey of the actual condition for housing buildings such multi have been raised in classification due to that the existing law systems including the current use classification of residential buildings have been defined unclearly. Especially, various social problems have yielded in line with emergence of the housing type which is not legally classified as residential however used for the living purpose practically. Current zoning planning and related law system have rigidity. So, It is required to introduce a flexible classification system which protects the residential environment based on the housing purpose, function and habitability and provides correspondence between residence and ownership/management method. The legal classification system should be revised in a way that the housing use classification corresponds with the zoning system through breakdown of the use classification system

  • PDF

설비공사의 하자사례 현황 분석 1

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.11 s.196
    • /
    • pp.27-35
    • /
    • 2006
  • 하자발생은 막대한 보수비용과 함께 업체의 이미지와 신뢰성을 실추시키는 한 요인이 되고 있다. 따라서 설비건설업계는 가급적이면 하자발생률을 최대한 낮추기 위해 노력하고 있다. 건축물에서는 특히 공동주택, 주상복합건물에서 하자발생 빈도가 가장 많다. 설비건설업계 A업체의 경우 고급아파트 주거시설의 하자비가 전체의 78%정도를 차지하고 있는 것으로 조사되었다. 이 업체의 경우 지난 3년간 평균 매출액 대비 0.58%의 하자가 발생되어 경영에 어려움을 가중시킨 것으로 나타났다. 따라서 하자가 발생되면 업체 경영에 어려움은 물론 이미지 손상이라는 큰 타격을 주기 때문에 업체들의 하자발생을 방지하기 위한 노력이 절실하다. 월간 '설비건설'은 설비건설업계 하자 중 제일 많이 발생하는 공동주택 하자발생 현황을 조사하여 기획특집으로 마련함으로써 향후 하자발생 예방에 대한 지표를 제시코자 한다. 이번 호에는 설비건설업체들의 하자발생 현황을 게재하고, 다음 호에는 전 건설업 중 설비건설 분야의 하자발생 현황 등을 게재할 계획이다. 업체로서는 하자발생을 내놓기 꺼려하는 부분이기 때문에 본지는 업체명을 게재하지 않았다. 자료를 선뜻 내놓기 쉽지 않았음에도 불구하고 기꺼이 자료제공을 하여 주신 업체들에게 감사의 뜻을 전한다.

  • PDF

설비공사의 하자사례 현황 분석2

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.12 s.197
    • /
    • pp.33-40
    • /
    • 2006
  • 하자발생은 막대한 보수비용과 함께 업체의 이미지와 신뢰성을 실추시키는 한 요인이 되고 있다. 따라서 설비건설업계는 가급적이면 하자발생률을 최대한 낮추기 위해 노력하고 있다. 건축물에서는 특히 공동주택, 주상복합건물에서 하자발생 빈도가 가장 많다. 설비건설업계 A업체의 경우 고급아파트 주거시설의 하자비가 전체의 78% 정도를 차지하고 있는 것으로 나타났다. 이 업체는 지난 3년간 평균 매출액 대비 0.58%의 하자가 발생되어 경영에 어려움을 가중시킨 것으로 나타났다. 따라서 하자가 발생되면 업체 경영에 어려움은 물론 이미지 손상이라는 큰 타격을 주기 때문에 하자발생을 방지하기 위한 노력이 절실하다. 월간「설비건설」은 설비건설업계 하자 중 제일 많이 발생하는 공동주택 하자발생 현황을 조사하여 기획특집으로 마련함으로써 향후 하자발생 예방에 대한 지표를 제시코자 한다. 지난 호에는 설비건설업체들의 하자발생 현황을 분석하여 보았다. 이번 호에는 종합건설업체에서 분석한 하자발생 현황을 게재한다. 업체들이 하자발생 현황을 내놓기 꺼려하기 때문에 본지는 업체명을 게재하지 않았다. 자료를 선뜻 내놓기 쉽지 않았음에도 불구하고 기꺼이 자료제공을 하여 주신 업체들에게 감사의 뜻을 전한다.

  • PDF

A Study On the Mix Design and Quality Control System of High Strength Concrete for the Construct ion of High Rise Complex Structure (초고층 주상복합구조물에 적용한 고강도 콘크리트의 배합설계 및 품질관리 시스템에 관한 연구)

  • Kim, Sun-Gu;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.40-45
    • /
    • 2001
  • The purposes of this study were mix design and quality control of high strength concrete for the construction of high rise complex structure. Desired performances of this high strength concrete were slump flow 50$\pm$10cm, air content 4.5$\pm$1.5% and design strength 400kgf/$cm^2$. Experimental flow was that optimal mix design was selected in the indoor experiment and after that, producing test was done in the batcher plant. Excel lent results of experiment was obtained from binder content 475kg/$m^2$ with replacement ratio 10% of fly ash. The results of field application of high strength concrete was sufficiently satisfied both flowability and compressive strength.

  • PDF

An Investigation on the Existing Literature to Prevent Fire Spread of High-rise Buildings (고층 건축물의 화재확대방지를 위한 기존 문헌 조사)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.102-103
    • /
    • 2021
  • In Korea, starting with the Busan residential-commercial fire in 2010, the frequency of fire expansion in high-rise buildings has been continuously increasing. In the case of such large-scale fires, most of the fires generated from the inside tend to expand to the upper floors by riding the exterior material or exterior wall panels through the process of being ejected to the outside. It has been revised so that combustible exterior materials cannot be used in buildings. However, due to the legal fluoride level, the fire risk of high-rise buildings is still high, such as the case of a 33-story residential-commercial fire in Ulsan. In order to prevent such fire expansion, it is considered that it is necessary to first understand the nature of the fire occurring inside and the mechanism of the fire expansion in the upper floor. The purpose of this study is to propose improvements in domestic fire safety design through a review of existing literature to prevent fire expansion of high-rise buildings.

  • PDF

Design and Construction of the Burj Dubai Concrete Building Project (버즈 두바이 콘크리트 건물의 설계와 시공)

  • Abdelrazaq, Ahmad
    • Magazine of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.28-35
    • /
    • 2008
  • The Burj Dubai Project will be the tallest structure ever built by man; when completed the tower will be more than 700 meter tall and more than 160 floors. While the early integration of aerodynamic shaping and wind engineering considerations played a major role in the architectural massing and design of this multi-use/residential tower, where mitigating and taming the dynamic wind effects was one of the most important design criteria, the material selection for the structural systems of the tower was also a major consideration and required detailed evaluation of the material technologies and skilled labor available in the market at the time Concrete was selected for its strength, stiffness, damping, redundancy, moldability, free fireproofing, speed of construction, and cost effectiveness. In addition, the design challenges of using concrete for the design of the structural system components will be addressed. The focus on this paper will also be on the early planning of the concrete works of the Burj Dubai Project.

A Case Study on the Evaluation Technique of Evacuation Safety in Building Fire (건축물화재시의 피난안전에 관한 평가기술에 대한 사례조사)

  • Kwon, Young-Jin;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.115-116
    • /
    • 2020
  • Recently, due to fires in high-rise residential and commercial buildings and apartments in Ulsan and Busan, the issue of evacuation safety in the event of a building fire is being closely watched. In the evacuation safety design for these building fires, it is important to secure evacuation routes considering the spatial characteristics of the building or the characteristics of the occupants and to take measures to protect the evacuation routes in order to ensure the safety of the occupants in the event of a fire. Although simulation is mainly used in Korea to assess the safety of evacuation, there is a big difference in that the Building Standards Act provides tools that can be calculated more than simulation in neighboring Japan. In addition to the evaluation method, which is called the "Building Law Assessment Methods" in Japan, the research team considered that it is important to know the process of evaluation in future domestic research, and investigated the contents of the evaluation process and wanted to apply it first to domestic buildings in the future.

  • PDF

A Layout Planning Optimization Model for Finishing Work (건축물 마감공사 자재 배치 최적화 모델)

  • Park, Moon-Seo;Yang, Young-Jun;Lee, Hyun-Soo;Han, Sang-Won;Ji, Sae-Hyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.1
    • /
    • pp.43-52
    • /
    • 2011
  • Unnecessary transportation of resources are one of the major causes that adversely affect construction site work productivity. Therefore, layout related studies have been conducted with efforts to develop management technologies and techniques to minimize the resource transportation made at site-level. However, although the necessity for floor-level layout planning studies has been increasing as buildings have become larger and floors have become more complicated, studies to optimize the transportation of materials inside buildings are currently not being actively conducted. Therefore, in this study, a model was developed using genetic algorithms(GA) that will enable the optimization of the locations of finishing materials on the work-floor. With the established model, the arrangement of diverse materials on complicated floors can be planned and the optimized material layout planning derived from the model can minimize the total material transportation time spent by laborers during their working day. In addition, to calculate travel distances between work sites and materials realistically, the concept of actual travel distances was applied. To identify the applicability of the developed model and compare it with existing methodologies and analyze it, the model was applied to actual high-rise residential complexes.

Modal Properties of a Tall Reinforced Concrete Building Based on the Field Measurement and Analytical Models (실측 및 해석모델에 의한 철근콘크리트조 주상복합건물의 모드특성)

  • Kim, Ji-Young;Kim, Ju-Yeon;Kim, Mi-Jin;Yu, Eun-Jong;Kim, Dae-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.3
    • /
    • pp.289-296
    • /
    • 2009
  • Natural frequency is a key parameter to determine the seismic and wind loading of tall flexible structures, and to assess the wind-induced vibration for serviceability check. In this study, natural frequencies and associated mode shapes were obtained from measured acceleration data and system identification technique. Subsequently, finite element(FE) models for a tall reinforced concrete buildings were built using a popular PC-based finite element analysis program and calibrated to match their natural frequencies and mode shapes to actual values. The calibration of the FE model included: 1) compensation of modulus of elasticity considering the mix design strength, 2) flexural stiffness of floor slabs, and 3) major non-structural components such as plain concrete walls. Natural frequencies and mode shapes from the final FE model showed best agreement with the measured values.