• Title/Summary/Keyword: 주상복합 건축물

Search Result 54, Processing Time 0.028 seconds

An Empirical Study for Cost Saving Effect Analysis When Using Seismic Reinforcing Bar (내진 보강용 철근 사용 시 비용 절감 효과 분석을 위한 실증적 연구)

  • Lee, Jong-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.120-127
    • /
    • 2016
  • Due to the enlargement and high-rise of reinforced concrete structure, the application of high functional material is required. However, high-strength bar is recently introduced to the country and the material is insufficient to measure the variation of quantity of rebar quantitatively when using high-strength bar. For these reasons, this study is to provide useful data in cost decision making when applying high-strength bar at a stage of architectural project planning. For residence-commerce complex buildings, we set up six types of conditions such as in case of using only rebar, in case of using only high-strength bar, in case of using rebar mixed with high-strength bar and so on. With the standard of study model 1 that applies only SD400 regardless of rebar diameter, the analyzed result of rebar variation and the cost change of construction in other study model is as follows. When the rebar amount and cost in study model I was 100%, each ratio was 88.3% and 90.5% in study model II, 80.2% and 83.4% in study model III, 91.9% and 93.5% in study model IV, 88.9% and 87.7% in study model V and 82.4% and 85.5% in study model VI. Therefore, in case of rebar amount and construction cost, study model III was evaluated as the best that was applied only SD600.

A Study on the Analysis of the Circulation Planning Importance in mixed-use Buildings (주상복합 건축물의 동선계획 중요도 분석에 관한 연구)

  • Kim, Young-Sun;Yang, Seung-Jung;Jun, Han-Jong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.12
    • /
    • pp.103-112
    • /
    • 2018
  • High-rise mixed-use buildings are consisted of various facilities and circulations. Since various facilities and circulations are planned in a single site, circulation planning should be established after identifying the exact characteristics of facility and circulation. To this end, the components of the circulation planning in accordance with the formation of facility types are analyzed through the survey of experts based on Delphi Method. To identify the characteristics of the mixed-use buildings, by figuring out how the elements of circulation planning which are sought to be important by the planner has been reflected through analysis of the correlation between two sections. Researching on the circulation between two sections through Delphi Method and reflected circulation planning, it reaches the conclusion that the circulation of planning on the subject building is applied following the importance. In other words, the components of circulation planning which were sought to be important by the planner are reflected significantly when they planned the circulation planning on that mixed-use buildings. However, in case of design on the outdoor vehicle circulation, minimizing on the vehicle circulation at the 1st floor is not applied for the majority of the subject buildings different from the importance. In early 2000, high end residential buildings designed for mixed-use building have been specialized at vehicle-centered outdoor space and hotel style drop-off. Contrastively, sizable outdoor space at the 1st floor is designed to open to the residents and the local by minimizing the vehicle circulation in recent. Finally it shows that the way of circulation planning has been changed in accordance with time and trend.

Maintenance Performance Improvement Method of the Buildings in Design Phase (설계단계에서 건축물의 유지관리성능 향상 방안;건축계획분야를 중심으로)

  • Yoon, Ho-Bin;Kim, Seung-Jin;Lee, Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.692-697
    • /
    • 2006
  • The importance about the maintenance consideration of the building has a great impact and regarding the life continuation of the building the many interest is becoming intensively. The housing lot of the heart of urban at the capital region has insufficient recently and the construction of the ground complex building in solution for the insufficiency is increasing at the rapid pace. The ground complex building is brings the maximization of land use from inside the site, but maintenance consideration phase is caused by administration cost share and administration bound limit where person is concerned for a many problem point it contains. The objective of the present paper is that the building is maintain an efficiency initially and is improve in order to develop guide line for a maintenance consideration improvement from design phase. According as literature research and question research is enforce, the paper is escape problem point the maintenance consideration and is bring up guide line for the architectural plan field and the maintenance consideration improvement of the building. Result of the study is expected a help in maintenance consideration improvement during life cycle of the building

  • PDF

An Experimental Study on the Semi-Adiabatic Temperature Rise Test of Concrete Considering Outside Temperature and Specimen Size (외기온도 및 시험체 크기를 고려한 콘크리트의 간이-단열온도 상승시험에 관한 실험적 연구)

  • On, Jeong-Kwon;Kim, Young-Sun;Moon, Hyoung-Jae;Nam, Jeong-Soo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.563-571
    • /
    • 2021
  • Recently, due to the increase in high-rise apartment and residential-commercial complex buildings, a number of mega-class mass concrete members with a thickness of 3m or more have been designed. As the construction of mass concrete such as transfer beam and slab is increasing not only in foundation members but also in special structures, research on reducing temperature cracks in mass concrete is being conducted. To review temperature cracks in mass concrete, it is important to review the thermal properties of concrete, but it is difficult to use an adiabatic temperature rise tester in the field, so the semi-adiabatic temperature rise test is mainly used. In this study, to improve the accuracy of the results of concrete heat characteristics gained by the semi-adiabatic temperature rise test, various factors affecting heat loss compensation and methods were reviewed and presented.

A Study on the Productivity Analysis of Finishing Works on Super High-rise Mixed_use Building (초고층 주상복합 건축물 마감공사의 공종별 생산성 비교에 관한 연구)

  • Hong, Bo-Bae;Kim, Yong-Man;Kim, Ju-Hyung;Kim, Jae-Jun
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.165-170
    • /
    • 2010
  • Super high-rise mixed use buildings require a longer period for construction. Especially finishing work takes up about 40% of the whole construction period. Thus, finishing work is becoming an important factor in determining the construction period along with earth work and frame work. As the expected returns added by the reduction of the period and cost in constructing super high-rise mixed use buildings are huge, the expectations are now increasing for the possible gains. In this respect, as the period of finishing work is easier to be shortened than that of frame work, the efforts to acquire the technical knowledge to reduce the finishing work period are now being required. Accordingly, in this study, we aimed at suggesting the basic data for designing an economic plan for finishing-work procedure by analyzing the productivity of each work type of finishing work procedure on the basis of the execution and results of a construction method as a time-flexible finishing work plan. For this, we categorized the work types of finishing work procedure into each work unit and provided a work-system for each of them. Also, with case studies, we calculated the detailed amounts of the work-loads, required materials, productivity, and productivity index of the main work types of finishing work procedure and each of their separate work units as well as analyzed the relationship between the value results to suggest a better way to improve its productivity.

A Study on the Plan Characteristics and Unit Floor Type Through the Zoning Analysis of High-rise Residential Buildings (초고층 주상복합 건축물에서 조닝분석을 통한 단위세대 평면 유형 및 계획특성에 관한 연구)

  • Sung, Lee-Yong
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.6
    • /
    • pp.54-61
    • /
    • 2012
  • The aim of this study is to understand the plan characteristics used in unit floor planning mainly with examples of mixed-use residential tall buildings. The study will extract plan characteristics mainly using the graph expressive technique with essential information of the zoning function of residential space, rather than merely analyzing the various construction floor plans by type. The research method involves studying a group of 50-story buildings (over 200 meters) which were built between 2002 and 2008. Among 6 high-rise residential buildings case, we extract the most preferred type from 34 types, And then we simply classify rooms in 3 zoning, the master, living and children's zones. Finally we analyze the correlation among 3 simple zone and then extract some model type. The results of this study revealed three main findings. First, using the 3 functional zones, the shape of the main building and the unit floor plan can be analyzed simply even when they appear to be complicated. Second, we can extract common features when we analyze the unit floor plan from the viewpoint of the penetrability among 3 zoning. Third, we can extract 2 types when we analyze the unit floor plan from the viewpoint of 3 connected functional zoning concepts.

  • PDF

Establishment of Pre-Pilot Test Bed for Real Scale Experiment Study in Smoke Management (실규모 연기제어 실험연구를 위한 Pre-Pilot Test Bed 구축)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Joo, Sang-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.81-84
    • /
    • 2012
  • 건축물에서 화재가 발생할 경우 연기에 의한 요인이 인명피해의 주요 원인으로 파악되고 있다. 특히 건축물이 고층화, 복합화, 대형화되면서 화재시 연기에 취약한 건축물이 증가하고 있고, 또한 기존의 연기제어 설계기준이 개선되어야 할 필요가 발생하고 있다. 이러한 요구에 부응하기 위해서는 새로운 조건에 대한 연기확산 및 연기제어에 대한 수행되어야 하며, 이론 수치해석적 연구와 더불어 실제적인 실험적 연구가 되어야 한다. 한국건설기술연구원 화재안전연구센터에는 5층규모의 제배연 실험동이 건립되어 있으며, 다양한 건축물 조건 및 연기제어 방식에 따른 실규모의 실험적 연구가 가능하도록 설비가 구성되어 있다. 본 논문에서는 이러한 Pre-Pilot Test Bed의 구축현황과 관련 실험내용을 소개하고자 한다.

  • PDF

Study on the Eco-friendly Design Methods of the High-rise Residential-Commercial Building -Based on a work of Ken yeang, Bishopsgate Towers- (초고층 주상복합건축물의 친환경적 디자인 방법에 대한 연구 -켄 양의 Bishopsgate Towers를 중심으로-)

  • Kim, Sun-Ok;Oh, Se-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.283-286
    • /
    • 2005
  • In the modern city in which the high-density and complex land use is needed, high-rise residential-commercial buildings appeared as a scheme to arrange a metropolitan residence with multiple high-techs and to induce activation of the city with leading the settled population to flow into the city. And the need of the times is to actively apply the eco-friendly notion to the architecture. In this study, the works of Ken Yeang who is regarded as an eco-friendly architect to make high-rise residential-commercial buildings ecological should be focused on with analyses of eco-friendly characteristics in inside, intersection between inside and outside, and outside of his works. The result o the study would be the suggestion to design eco-friendly high-rise buildings which make the city rise in quality.

  • PDF

Comparison of Evacuation Efficiency for Stair Width and Code for Occupant Load Calculation in High-rise Buildings (고층의 주상복합건축물 계단폭과 수용인원 산정기준에 따른 피난효율의 비교)

  • Lee, Yang-Ju;Ko, Kyoung-Chan;Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • An evacuation simulation was carried out to confirm evacuation efficiency for stair width and problems in calculation of occupant load for high-rise buildings. The evacuation time and number of evacuated persons from a 39 story condominium-mercantile building were calculated by using Simulex for stair widths of 1.2 m, 1.5 m, and 1.8 m. The total occupant load based on the Korean code was higher than the number of actual residents by 2.3 times, and that based on the NFPA 101 Life Safety Code by 2.6 times, respectively. For the occupant load based on the Korean code, smaller stair width resulted in lower evacuation efficiencies due to bottlenecks in egress. For the actual residents and NFPA code-based occupant load, a high evacuation efficiency and negligible effects of the stair width on evacuation efficiency were confirmed. It was shown that there was a bottleneck even at the stair width of 1.8 m for the Korean code-based occupants, while the stair width of 1.2 m provided safe egress to the actual residents or NFPA code-based occupants. This recommended further studies on possibility of lowering the level of the Korean code in calculation of the occupant load.