• Title/Summary/Keyword: 주사시술

Search Result 86, Processing Time 0.025 seconds

ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL (Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구)

  • Choi, Seung-Hoon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of the Nd:YAG laser and the Er:YAAG laser on etching enamel for direct bonding of orthodontic bracket. The advantages of laser etching rather than conventional acid etching are to reduce the subsurface demineralization rate, to inhibit the spillage of acid onto uninvolved ""its of enamel, and to save the clinical manipulation time involving drying, trashing and drying again. 189 freshly extracted human premolars were prepared for this research. 165 out of them were divided into 11 groups of 15 teeth. One group was acid etching and the rest groups were irradiated with Nd:YAG laser by four different energy levels(100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps) and with Er:YAG laser by six different energy levels(60mj 5pps, 60mj 10pps, 100mj 10pps. 200mj 10pps, 200mj l5pps, 400mj 10pps). Shear bond strength was tested with Instron after 24 hours, one week, and three weeks. Twenty-four out of 189 teeth were divided into twelve groups untreated control, acid etching, and ten laser irradiation subgroups. And the ultrastructural enamel surfaces of each group were observed with scanning electron microscope. The results were as follows; 1. The means and the standard deviations of shear bond strength of Nd:YAG and Er:YAU laser irradiation by different energy levels were obtained. 2. Shear bond strengths of Er:YAG laser irradiation groups were higher than those of Nd:YAG laser irradiation groups at the identical energy level. 3. Maximum bond strengths was achieved at the energy of I50mj, 20pps in Nd:YAG laser irradiation groups or 60mj, 10pps in Er:YAG laser irradiation groups. 4. It was acceptible for direct bonding to irradiate lb0mj 20pps with Nd:YAG laser or to irradiate 60mj 10pps with Er:YAG laser considering the results of shear bond strength tests and SEM obsesvation.

  • PDF

Effects of GnRH Agonist Administered to Mouse on Apoptosis in Ovary and Production of Estradiol and Progesterone (생쥐 내로 투여된 GnRH Agonist가 난소내 세포자연사와 Estradiol 및 Progesterone 합성에 미치는 영향)

  • Hong Soonjung;Yang Hyunwon;Kim Mi-Ran;Lee Chi-Hyeong;Hwang Kyung-Joo;Kwon Hyuck-Chan;Yoon Yong-Dal
    • Development and Reproduction
    • /
    • v.7 no.1
    • /
    • pp.49-56
    • /
    • 2003
  • There have been reports that administrated high-dose gonadotropin-releasing hormone-agonist(GnRH-Ag) suppresses endogenous gonadotropin production and inhibits function of ovary. In human IVF-ET program, however, GnRH-Ag is employed in large amounts during superovulation induction resulting to luteal phase defects which must be supported with progesterone. To elucidate the reason of luteal phase defects by GnRH-Ag, the aim of this study was to investigate the apoptosis changes in the ovary and the hormonal changes in the serum after GnRH-Ag and PMSG administration in adult mice in a method similar to human superovualtion induction. GnRH-Ag(10 ${\mu}$g) or saline was injected every 12h beginning 48h prior to PMSG injection until 48h at)or PMSG injection when blood sampling and ovary collection was performed. In results, the ovary weight in the GnRH-Ag only injection group was significantly lower when compared with the other two groups, PMSG only or PMSC + GnRH-Ag injection. The ratio of preantral follicles in the ovary are increased in the GnRH-Ag only group, while the ratio of antral follicles are decreased and the corpus luteum ratio is increased in the PMSG + GnRH-Ag group. The proportion of all follicles showing apoptosis in the GnRH-Ag only in.iection group was seen to be more than twice the proportion seen in the PMSC only injection group, and such increased apoptosis is decreased after addition of PMSC. The serum levels of both estradiol and progesterone were significantly lower in the CnRH-hg only group compared to those in the other two groups. When the administration of GnRH-Ag were followed by PMSG in;ection, however, estradiol concentration was completely recovered compared to the serum level of PMSG group, but not progesterone level. In conclusion the use of GnRH-Ag in human IVF-ET program may induce the apoptosis and the suppression of hormone production by ovary leading to luteal phase defects, thus adequate progesterone support seems to be necessary against them.

  • PDF

The Analysis of the Prevention against Virus Infection in Dental Hygienist at Medical Treatment (치과위생사의 진료실 감염방지에 대한 행태 분석)

  • Yoon, Mi-Suk;Choi, Mi-Suk
    • Journal of dental hygiene science
    • /
    • v.7 no.2
    • /
    • pp.101-106
    • /
    • 2007
  • This research was based on self-filling survey which 128 dental hygienists who work in dental clinic and dental hospital on May 2006 through July 2006. This survey was analyzed the prevention against virus infection in dental hygienist at medical treatment. As follows analyzed results The experience of get a hand pricked by an infected needle rate is 76.6 percent and the majority of the dental hygienist are sterilize by disinfectant after wash hand and draw blood. The most of dental hygienist are experienced the education of the prevention infection in student and they think that It is necessary to prevention infection in medical treatment. The proportion of use the glove and mask in medical treatment and disuse the glove after medical treatment and the mask when mask get damped is high but the rate of put on the goggle in medical treatment and use the glove in washing and re-treat is low irrespective of age, clinical career, work place. As a result of Independent-sample T Test, the Hygienist who have experience the education of the prevention against virus infection are more excellent work than in-experience group in medical treatment. So we can find that the experience of the education of the prevention infection is very significant to prevention infection in dental hygienist.

  • PDF

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

The effect of 8 French catheter and chest tube on the treatment of spontaneous pneumothorax (자연기흉에 있어서 8 French 도관과 흉관의 삽입 치료 효과)

  • Kang, Yoon-Jeong;Koh, Hyoung-Gee;Shin, Jong-Wook;Lim, Seong-Yong;Choi, Jae-Sun;Yu, Ji-Hoon;Park, In-Won;Choi, Byoung-Whui;Hue, Sung-Ho;Seo, Seung-Cheon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.410-419
    • /
    • 1996
  • Background : Spontaneous pneumothorax have been managed with a variety of methods. The technique most frequently used is chest tube drainage. Small caliber catheters were first used in the management of pneumothorax complicating the percutaneous needle aspiration lung biopsy, and the try to treat spontaneous pneumothorax also has been reported. However, the value of small caliber catheters in spontaneous pneumothorax has not been fully evaluated. So, we tried to elucidate the efficacy of 8 French catheter in the management of spontaneous pneumothorax. Method : From January, 1990, to April, 1994, 44 patients with spontaneous pneumothorax treated at Chung-Ang university hospital were reviewed. The patients were sub-divide into 8 French catheter insertion group (n=21) and chest tube insertion group (n=23). We compared the presence of underlying lung disease, the extent of the collapse, the duration of indwelling catheter and complication between two groups. Results : 1) The duration of indwelling showed no significant difference between 8 French catheter group and chest tube. But, complication after insertion as subcutaneous emphysema was developed in only chest tube group. (p<0.05) 2) In the primary spontaneous pneumothorax, all case of the pneumothorax of which size was less than 50% showed complete healing with 8 French catheter insertion. Whereas the success rate in patients with large pneumothorax (more than 50%) was tended to be dependent on the age. 3) In the patients with secondary spontaneous pneumothorax who were managed with 8 French catheter, the success rate was trended to be high if the underlying disease of pneumothorax was not COPD and if the patient was young. Conclusion : These results show that 8 French catheter insertion probably was effective in the pneumothorax less than 50%, the primary spontaneous pneumothorax, young age or secondary pneumothorax not associated with COPD.

  • PDF

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF