• Title/Summary/Keyword: 주사시술

Search Result 86, Processing Time 0.02 seconds

Blind and Ultrasonography-guided Injection Therapy for Calcific Tendinitis of Supraspinatus (극상건 석회화 건염에 대한 맹검 주사요법과 초음파하 주사요법)

  • Moon, Young-Lae;Nam, Gi-Young;Noh, Kyung-Hwan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.86-90
    • /
    • 2008
  • Purpose: To evaluate the differences between blindly and ultrasonography (US)-guided during multiple needling and dextrose injection technique for calcific tendinitis of shoulder. Materials and Methods: We chose 36 symptomatic calcific tendinitis patients, whose age ranged from 27 to 69. Our procedures were multiple needling and injection of dextrose over the lesion of calcific deposits. The bind injection group were 19 patients whose age ranged from 27 to 64-year-old (mean 52.2), and the US-guided injection group were 17 patients ranged from 31 to 69-year-old (mean 49.0). We compare these groups by VAS (visual analogue scale) and range of motion before and after procedures. Results: There is no difference between two groups in VAS and ROM before procedure (p>0.05). Two groups revealed significant improvement without limitation of shoulder function, however, the group under US-guided revealed better results than under blind (VAS:p=0.001, Flexion:p=0.000, Abduction:p=0.000, External rotation: p=0.016). Conclusion: Ultrasonography-guided procedure showed better results than blind, so the use of ultrasonography is more promising procedure.

  • PDF

Accuracy of the Glenohumeral Joint Injection According to the Approach (도달 방법에 따른 관절와상완 관절내 주사의 정확도)

  • Choi, Nam Yong;Lee, Kang Wook;Kim, Hyung Seok;Song, Hyun Seok
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.45-52
    • /
    • 2013
  • Purpose: We wanted to compare the accuracy between the blind anterior approach and ultrasound guided posterior approach, which are preferred in the present clinical practice for the glenohumeral joint injection. Materials and Methods: The consecutive 95 cases were included in that the glenohumeral joint injection was done in the university hospital and the medical record and ultrasonography were available. There were 52 cases which were injected by blind anterior approach (group I) and 43 cases who were injected by ultrasound guided posterior approach (group II). The injection was decided as accurate if the fluid was visualized in the posterior joint under the ultrasound. We evaluated the range of motion before and after 2 weeks of injection. A subjective satisfaction of the patients was interviewed at the 2 weeks after injection. Results: The accuracy of the glenohumeral joint injections of the group I and group II was 80.8% and 90.7%, respectively. The range of motion was improved for the all cases regardless of the approaches. At the 2 weeks after injection, the subjective satisfaction (better than good) was achieved in 73.7%. Conclusion: The accuracy of the blind anterior approach for the glenohumeral joint injection was 80.8%. The accuracy of the ultrasound guided posterior approach was 90.7%. In this comparative study by the one physician, the ultrasound guided posterior approach showed the better accuracy.

  • PDF

Ultrasound-guided Intervention in Cervical Spine (경추부 초음파 유도하 중재술)

  • Moon, Sang Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.49-66
    • /
    • 2014
  • Traditionally, cervical interventions have been performed under fluoroscopy. But radiation exposure is the major concern when obtaining fluoroscopic images and even under real-time fluoroscopy with contrast media or CT guidance, some cases of serious spinal cord injuries, cerebellar and brain stem infarction have been reported by unintentional intra-arterial injections especially during the transforaminal root blocks. Recently, the use of ultrasound-guided cervical interventions have increased. Ultrasound offers visualization of soft tissues including major neurovascular structures and also allows to observe the spread of injectant materials around the target structure. Ultrasound is radiation free, easy to use and the image can be performed continuously while the injectant is visualized in real-time, increasing the precision of injection. Importantly, ultrasound allows visualization of major nerves and vessels and thus leads to improve safety of cervical interventions by decreasing the incidence of injury or injection into nearby vasculature. We therefore reviewed to investigate the feasibility of performing cervical interventions under real-time ultrasound guidance.

  • PDF

Morphological Damages of Hair by Heat Formation of Rods during Heat Perm (열 퍼머넌트 웨이브 시술 시 로드의 열 형성에 따른 모발의 형태적 손상에 관한 연구)

  • Oh, Su-Ryeon;Lim, Sun-Nye
    • Journal of Industrial Convergence
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2020
  • In general, heat-based treatments are preferred to form the most natural and elastic curls. Therefore, this study measured the degree of hair damage, which has an influence on hair, in relation to the heat formation of the rods used during perms using a scanning electron microscope (SEM). To examine the influence of the heat formation rods on permanent waves, this study measured the temperature transmitted from such rods. Then, a treatment was given after cutting the hair according to the round shape. According to observation with a SEM, hair breakage was found in the portion in direct contact with the heat, and the broken surface was smooth. According to the study results, it is anticipated that there should be many studies on the rods used during perms in the consideration of their structure and importance using materials that have the property of even heat transmission.

The Preliminarily Result of Radiologic Disappearance of the Calcific Material on One Time Ultrasonographic Assisted Needling (견관절의 석회화 건염에서 초음파 유도하 1회 주사요법에 의한 방사선학적 조기 소멸 정도에 대한 예비보고)

  • Yoo, Jae-Chul;Shon, Min-Soo;Koh, Kyoung-Hwan;Lim, Tae-Kang;Lee, Yeong-Seok
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose: The purpose of this study is to report the preliminarily result of the radiologic disappearance of the calcific material, regardless of the size, type or location, on one-time ultrasonographic (US) assisted needling for calcific tendinitis of the shoulder. Materials and Methods: From March to August 2011, 46 patients (47 shoulders) with symptomatic calcific tendinitis were treated by one-time US assisted needling. Initially, a diagnostic US was performed with patient to determine the locations, numbers and sizes of calcific deposits. After 1% lidocaine local anesthesia, the calcific material was punctured with an 18-gauge needle under US monitoring. If no calcific material was aspirated after 2 or 3 additional attempts, the deposits was performed multiple puncture to achieve decompression. And then all patients were performed subacromial corticosteroid injection. All patients were followed up 4 weeks after procedure. To assess the radiologic disappearance after one-time US assisted needling, simple radiographs of the treated shoulder were performed and size, dense, and morphology of the calcific deposits were compared with those in baseline radiographs. For clinical evaluations, visual analogue scale for pain and function (PVAS and FVAS), and American Shoulder and Elbow Surgeons (ASES) score were assessed. Results: There were 11 male and 35 female patients with the mean age of 53.8 years (28-71). The morphology of the calcific deposits were 31 type A and 16 type B by French Arthroscopic Society classification and mean size was $2.9{\pm}6.7$ mm before the procedure. At 4 weeks after the index procedure, the radiographic unchanged group was included in 10 cases and changed group was 37 cases. No intergroup difference for the clinical results after the procedure was evident, but group FAS classification before the procedure was significantly different (p=0.011). Conclusion: At 4 weeks after one-time US assisted needling for calcific tendinitis of the shoulder, the radiographic size- or dense-changed cases were showed in 79%, regardless of the size, type or location of the calcific material. But the radiographic nearly or complete disappearance were showed in only 21%.

  • PDF

The Effectiveness of Ultrasonography-guided Injection at Infraspinatus of Shoulder in Patients with Posterior Shoulder Pain Induced Horizontal Adduction Test (수평내전에 의해 악화되는 견관절 후방 통증 환자에서 초음파하 극하근 주사요법의 효과)

  • Pak, Chi Hyoung;Moon, Young Lae;Lee, Hyeon Jun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • Purpose: The purpose of this study was to analyze the effectiveness of local steroid injection for infraspinatus under ultrasonographic guidance in patients with posterior shoulder pain during horizontal adduction test. Materials and Methods: Twenty one cases of patients, from May 2013 to May 2014, showed positive horizontal adduction test were retrospectively analyzed. We performed ultrasonography-guided infraspinatus injection using steroid to these patients in the outpatient clinics. We evalulated results for visual analogue score (VAS) for pain, UCLA score for these patients before injection, following 3 months and 6 months after injection. Results: After ultrasonography-guided infraspinatus injection using steroid, there were clinically significant improvements in VAS and UCLA score at 3 month's follow-up period (p<0.05). But there were no significant differences in VAS and UCLA score between 3 months and 6 months (p>0.05). Fourteen of 21 (67%) cases showed much improved and improved satisfaction. Respectively, seven of 21 (33%) cases showed not improved and aggravation satisfaction. Conclusion: Ultrasonography-guided infraspinatus injection using steroid is an effective treatment method for the patients with exacerbated posterior shoulder pain during horizontal adduction test.

  • PDF

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

Lumbar Facet Joint Injection: A Review of Efficacy and Safety (요추 후관절 주사: 임상적 유용성과 안전성에 대한 고찰)

  • Yoonah Do;Eugene Lee;Choong Guen Chee;Joon Woo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.54-76
    • /
    • 2024
  • Facet joint arthrosis is a progressive degenerative disease that is frequently associated with other spinal degenerative disorders such as degenerative disc disease or spinal stenosis. Lumbar facet joint arthrosis can induce pain in the proximal lower extremities. However, symptoms and imaging findings of "facet joint syndrome" are not specific as they mimic the pain from herniated discs or nerve root compression. Currently, evidence for therapeutic intra-articular lumbar facet joint injections is still considered low, with a weak recommendation strength. Nevertheless, some studies have reported therapeutic effectiveness of facet joint injections. Moreover, the use of therapeutic facet joint injections in clinical practice has increased. This review article includes opinions based on the authors' experience with facet joint injections. This review primarily aimed to investigate the efficacy of lumbar facet joint injections and consider their associated safety aspects.

Ultrasound-Guided Proliferative and Local Steroid Injection for Subacromial Bursitis (견봉하 점액낭염에서 초음파 하 증식과 국소 스테로이드 병합 주사 요법)

  • Nam, Ki Young;Moon, Young Lae
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.6-9
    • /
    • 2008
  • Purpose: To investigate the effectiveness of injection therapy in the treatment of subacromial bursitis. Materials and Methods: A total of 38 patients with sonographic confirmation of subacromial bursitis were recruited into this study. The shoulder abduction range of motion and visual analog scale (VAS) were compared before injections and 3 wks after the completion of injections. Results: The shoulder range of abduction before injection was $77.89{\pm}14.17$ degrees and improved to $148.68{\pm}13.39$ degrees 3 wks after the injection treatments (P<0.05). VAS before injection was $6.8{\pm}1.4$ and improved to $1.4{\pm}0.8$ 3 wks after the injection treatments (P<0.05). Conclusions: Ultrasound may be used as an adjuvant tool in guiding the needle accurately into the inflamed subacromial bursa. The ultrasound-guided injection technique can result in significant improvement in shoulder abduction range of motion in treating patients with subacromial bursitis.

  • PDF

A Study on the Comparison of Detected Vein Images by NIR LED Quantity of Vein Detector (정맥검출기의 NIR LED 수량에 따른 검출된 정맥 이미지 비교에 관한 연구)

  • Jae-Hyun, Jo;Jin-Hyoung, Jeong;Seung-Hun, Kim;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Intravenous injection is the most frequent invasive treatment for inpatients and is widely used for parenteral nutrition administration and blood products, and more than 1 billion procedures are used for peripheral catheter insertion, blood collection, and other IV therapy per year. Intravenous injection is one of the difficult procedures to be performed only by trained nurses with intravenous injection training, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Accordingly, studies on auxiliary equipment capable of visualizing the vein structure of the back of the hand or arm are being published to reduce errors during intravenous injection. This study is a study on the performance difference according to the number of LEDs irradiating the 850nm wavelength band on a vein detector that visualizes the vein during intravenous injection. Four LED PCBs were produced by attaching NIR filters to CCD and CMOS camera lenses irradiated on the skin to acquire images, sharpen the acquired images using image processing algorithms, and project the sharpened images onto the skin. After that, each PCB was attached to the front end of the vein detector to detect the vein image and create a performance comparison questionnaire based on the vein image obtained for performance evaluation. The survey was conducted on 20 nurses working at K Hospital.