• Title/Summary/Keyword: 주사간격

Search Result 216, Processing Time 0.029 seconds

Study on the Biodegtadable Aliphatic Polyester(III) : Compatibility of Copolyesterethylene/EVA (VA15%) Blends (생분해성 지방족 폴리에스테르에 관한 연구(III) : Copolyesterethylene/EVA(VA15%) 블랜드의 상용성)

  • Park, Tae-Wook;Kang, Hye-Jung;Kim, Yong-Joo;Lee, Chi-Giu
    • Applied Chemistry for Engineering
    • /
    • v.5 no.5
    • /
    • pp.889-898
    • /
    • 1994
  • Melt blends of copolyesterethylene(CPEE) and ethylene vinylacetate copolymer(EVA) with 15% vinylacetate content were prepared in the ratio of 0 to 100% CPEE with 10% interval for the purpose of obtaining useful biodegradable polymer system. Miscibility behavior of melt blend samples has been studied by observing the melting temperature change and cold crystallization temperature with differential scanning calorimetry. From the results of thermal analysis, it was shown that each 10% blend composition of CPEE and EVA had the partially miscibility. Useful compatibility has been observed in all blend composition except the samples of 50~80 % CPEE composition from the mechanical property study. Compatibility of these blend has been also observed with scanning electron microscopy. Biodegradability of CPEE/EVA blends has been evaluated by observing the change of specimen with Image analyzer before and after the inoculation with specific microorganism.

  • PDF

Comparative Pharmacokinetics of Platinum Coordination Complexes in Rats

  • Insook Jung;Lee, Juseon;Kim, Myungsoo;Changbae Jin;Younsoo Sohn;Park, Jongsei
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.243-243
    • /
    • 1996
  • 백금착물 항암제 후보물질로서 합성된 KBP31705-Cl27, KBP30603-901을 기존 화합물인 cisplatin 및 carboplatin과 pharmacokinetic profile을 비교 검토하였다. 웅성 Sprague-Dawley rat을 sodium pentobarbital 마취하에서 방광 및 대퇴동맥과 정맥에 polyethylene tubing을 사용하여 catheterization시켰다. Urine 배출이 안정화되었을 때 대퇴정맥내로 cisplatin과 KBP31705-Cl27은 2 mg/kg, carboplatin과 KBP 30603-901은 20mg/kg 용량으로 주사한 후 2, 4, 6, 8, 10, 15, 20, 30, 45, 60, 120 분에 대퇴동맥으로부터 혈액을 채취하였으며 urine은 약물투여 후 1시간 간격으로 4시간동안 채취하였다. Plasma와 urine중의 platinum농도는 inductively coupled plasma-mass spectrometer를 사용하여 측정하였고, pharmacokinetic parameters는 non-linear least square computer Program인 PCNONLIN을 이용하여 산출되었다. 혈중 platinum농도와 시간의 관계에서 KBP31705-Cl27은 cisplatin과 비교하여 alpha-phase에서 혈중 농도는 낮지만 비슷한 양상을 나타내었고, beta-phase에서는 비교적 느리게 소실됨을 보였다. Urine으로 4시간동안 배출된 platinum양은 각각 투여량의 52, 56%로서 두 약물에서 비슷하였다. 또한 KBP30603-901은 carboplatin과 비교하여 alpha-phase는 거의 비슷한 패턴을 나타내었으나, beta-phase는 훨씬 느리게 감소하여 반감기가 길다는 것을 보여 주었으며 또한 이것은 urine으로 4시간동안 배출된 platinum양이 KBP30603-901의 경우 투여량의 46%로서 carboplatin의 59%보다 적게 배출된다는 data와도 일관됨을 보여주었다. 이상의 결과로 볼 때 KBP30603-901이 다른 백금착물 항암제보다 체내에 머무르는 시간이 길어 혈중에서 보다 오랜 시간동안 머물러 높은 유효농도를 유지할 수 있을 것으로 사료된다.

  • PDF

Ag 나노입자에 의한 Semi-Polar InGaN/GaN LED의 광효율 증가

  • Lee, Gyeong-Su;O, Gyu-Jin;Kim, Eun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.373-373
    • /
    • 2013
  • 높은 효율의 InGaN/GaN 전광소자는 현대 조명 산업에 필수적인 역할을 하고 있다. 그러나 전광소자의 효율을 높이는 데에는 여러가지 한계들이 있다. 예를 들면 높은 전류에서의 효율저하, GaN 의 전위결함에 의한 비발광 재결합의 발생 등이 있다. 이러한 한계를 극복하고자 InGaN/GaN 전광소자의 효율을 높이기 위해 사파이어 기판의 표면을 거칠게 바꾸는 방법, 무분극 전광소자, 표면 플라즈몬 등 여러가지 많은 방법들이 개발되고 있다. c-plane InGaN/GaN LED 기반의 표면 플라즈몬 실험은 많은 연구가 수행되고 있으나, m-plane InGaN/GaN LED 기반의 표면 플라즈몬은 아직 연구가 진행되지 않았다. 본 실험의 목적은 표면 플라즈몬 효과를 이용하여 semi-polar InGaN/GaN LED의 광효율을 개선하는 것이다. 유기금속화학 증착 장비로 m-plane sapphire위에 $6{\mu}m$ 의 GaN 버퍼층을 증착하고 표면의 평탄화를 위해 $2{\mu}m$의 n-GaN을 증착하였다. 그 위에 3개의 다중양자우물 층을 증착하였고, 10 nm의 도핑이 되지않은 GaN를 증착하였다. 표면 플라즈몬 현상을 일으키기 위해 Ag박막을 10, 15, 20 nm 증착하여 급속 열처리 방법으로 $300^{\circ}C$에서 20분 열처리 하였다. 형성된 나노입자를 측정하기 위해 주사전자현미경으로 표면을 분석하였다. 표면플라즈몬에 의한 InGaN/GaN 광 세기를 측정하고자 여기 파장이 385 nm인 photoluminescence (PL) 를 사용하였다. 또한 내부양자효과의 증가를 확인하기 위해 PL을 이용하여 온도를 10~300 K까지 20 K 간격으로 광세기를 측정하였다. 향상된 내부 양자효과가 표면 플라즈몬에 의한 것임을 증명하기 위해 time-resolved PL을 이용하여 운반자 수명시간을 구하였다.

  • PDF

A Case of Phthiriasis Palpebrarum in the Eyelids of a Child (소아 안검에서 관찰된 사면발이증 1례)

  • Lee, Jong Hyuck;Rah, Sang Hoon;Kim, Yoon Hee;Song, Won Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.6
    • /
    • pp.800-803
    • /
    • 2002
  • A two year old male child complained of foreign body sensations bilaterally, and an itching sensation at both upper and lower eyelids for 2 months of duration. He was diagnosed with Phthiriasis palpebrarum after observation of adult louse and nits on slit-lamp examination. The treatment was accomplished by mechanical removal of the lices and nits by forceps and scissors, and then irrigation with 20% fluorescein was done under general anesthesia. Antibiotic eyedrops and ointment were applied to both eyes. The morphologic evaluation was performed with light microscopy and scanning electron microscopy. The follow-up interval was every weeks for one month and no louse or nit was found under slit-lamp examination. So we concluded that the Phthiriasis palpebrarum was eradiated completely. We report a case of Phthriasis palpebrarum had been review of the literatures.

Effects of Parenteral Lipid Formulas on Seurm Lipids Clearance in Normal Volunteers (지질 수액체 투여가 정상인의 혈장 지질변화에 미치는 영향)

  • Choe Myeon·Kim
    • Journal of Nutrition and Health
    • /
    • v.25 no.6
    • /
    • pp.461-467
    • /
    • 1992
  • Although intravenous fat emulsions are well accepted as a consituent of a total parenteral nutrition regimen it is still controversial how much it can be used and who to use it in consideration of physical situation of useres. In this study the effect of two marketed lipid formulas on serum lipids change was investigated. Each lipid formula was injected to twelve normal adult volunteers and a set of blood samples was drawn at 5 minute interval during the experiment. Changes of triglycerides. free fatty acids free glycerol total cholesterol and phospolipids in the serum wre determined. To calculate serum lipids clearance the phar-macokinetics of serum triglyceride fractional removal rate(k) and half-life time(t/2) were calculated using intravenous fat tolerance-test(IVFTT) None of the parameters determined in this experiment was statistically different between two marketed formulas. In summary the bolus injection of the lipid formulas did not produce any adverse effects and their elimination kinetics from the blood stream were similar.

  • PDF

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

산화아연의 박막 또는 나노선의 전기화학적 합성과 자외선 센서의 적용

  • Yun, Sang-Hwa;Lee, Dong-Gyu;Yu, Bong-Yeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.26.2-26.2
    • /
    • 2011
  • 최근 주목 받고 있는 산화아연(ZnO)은 레이저 다이오드, 가스 센서, 자외선 센서, 투명전극 등으로 다양하게 사용될 수 있어 연구개발이 폭 넓게 이루어지고 있는 상황이다. 특히, 3.3 eV의 direct bandgap 에너지를 가지고 있는 ZnO은 현재 자외선센서로 많이 적용되고 있는 물질인 GaN계열을 대체할 수 있는 유망한 물질로 주목 받고 있다. 공기중의 산소나 수분의 표면반응에 의한 자외선 측정을 하는 ZnO을 나노선으로 만들게 되면, 표면대비 부피비가 박막에 비해 급격히 증가하기 때문에 민감도가 커지고 반응시간이 짧아지게 된다. 본 연구에서는 자외선센서의 민감도와 반응성을 향상시키기 위해 전기화학적 합성법을 통해 ZnO의 박막과 나노선을 제조하였다. 사진공정을 통해 3 ${\mu}m$의 간격을 가진 금(Au) 전극을 만든 후, 전기화학적 합성법을 통해 아연이온이 포함된 용액에서 정전류를 흘려보내 아연 또는 ZnO을 증착시킬 수 있었다. 첫 번째로 ZnO을 양쪽 Au 전극에서 동시에 증착하여 두 박막이 접합하였고, 두 번째는 100nm의 지름을 가진 Ni 나노선를 전극 양쪽에서 자석을 통해 자기장을 형성해 정렬시키고 ZnO을 Au 전극과 Ni 나노선에 증착한 후, Ni 나노선를 산화시킴으로써, ZnO 나노구조를 형성하였다. 세 번째로는 Au 전극 양쪽에 아연을 전기화학적 합성을 하여 박막으로 증착하고 고온에서 산화과정을 통해 100 nm 이하의 지름을 가진 ZnO 나노선를 형성하였다. 이렇게 만들어진 세가지 구조의 ZnO의 나노구조와 결정성은 주사전자현미경과 X선 회절 분석기를 통해 측정하였으며, 자외선에 대한 민감도와 반응성은 365 nm의 파장을 가진 자외선발생기와 소스미터장치를 통해 측정하였다. 박막에서 100 nm 이하의 지름을 가진 ZnO 나노선로 갈 수록 자외선에 대한 민감도와 반응성이 향상되었다.

  • PDF

Study on the Biodegradable Aliphatic Polyester(V): Thermal and Mechanical Properties of Copolyesterethylene/LDPE Blend (생분해성 지방족 폴리에스테르에 관한 연구(V) : Copolyesterethylene/LDPE 블렌드의 열적 성질 및 기계적 성질)

  • Park, Tae-Wook;Kang, Bye-Jung;Kim, Yong-Joo;Lee, Chi-Giu
    • Applied Chemistry for Engineering
    • /
    • v.5 no.6
    • /
    • pp.1068-1077
    • /
    • 1994
  • Blend samples of biodegradable copolyesterethylene(CPEE) with LDPE were prepared by melt-mixing through 0 to 100% per 10% interval for studying of common use of biodegradable polymer. Miscibility behavior of blend samples has been studied by observing the melting temperature change, melting enthalpy, cold crystallization temperature and crystallization enthalpy using differential scanning calorimetry. It was shown that 10~30% blend composition of CPEE had the partial miscibility from the results of thermal analysis. Valuable compatibility has been observed in all blend composition except the samples of 30~80% CPEE component from results of mechanical properties. Morphology of blends has been observed with scanning electron microscopy. Biodegrability of CPEE/LDPE blends has been evaluated by measuring the change of weight after the inoculation with specific microorganism.

  • PDF

Inhibitory effects of Cervi Pantotrichum Cornu herbal acupuncture on type II collagen-induced arthritis (Type II Collagen으로 유발된 관절염에 대한 녹용약침의 억제효과에 관한 연구)

  • Kim, Jin-gyu;Kim, Kap-sung
    • Journal of Acupuncture Research
    • /
    • v.19 no.6
    • /
    • pp.155-170
    • /
    • 2002
  • 면역억제와 면역항진의 작용을 지닌 녹용(鹿茸)약침의 실험쥐에서의 type II collagen(CII)으로 유발된 관절염(CIA)에 대한 효과를 연구하였다. 본 실험에서 녹용(鹿茸)약침군과 생리식염수군을 대조군으로 하여 실험쥐에게 약침시술을 하였다. 녹용(鹿茸)약침이 CII에 작용하는 세포반응에 대한 효과를 검정하였는데, 대조군에서는 CII 유발주사 후 24일에 관절염이 관찰되었고, CIA의 정도가 점차적으로 심해졌다. 생리식염수 처리군과 비교해 24일 동안 하루에 한번 $50{\mu}g/kg$ 이상 용량의 녹용(鹿茸)약침은 CII 처리 T cell의 interleukin 2(IL-2)와 interferon-${\gamma}$($IFN-{\gamma}$) 생산능력을 억제했다. 또한 녹용(鹿茸)약침은 CII처리 임파절과 대식세포의 tumor necrosis facter ${\alpha}$($TNF-{\alpha}$)의 생산을 억제했다. 한편 CIA에 대한 약침효능의 지표는 녹용(鹿茸)약침을 14일간 하루에 한번씩 처리하면서, 소의 CII로 3주 간격으로 2번 유발접종을 실시하여 검정하였다. 첫 CII 유발접종과 동시에 일일 투여량 $100{\mu}g/kg$으로 14일간의 녹용(鹿茸)약침이 항체형성과 CII에 대한 지연형 과민성 뿐만 아니라 관절염의 증가도 막아주었다. 녹용(鹿茸)약침을 관절염 유발성 CII의 2차 접종과 동시에 시술한 결과, 관절염과 CII에 대한 면역반응을 억제하였다. 이에 저자는 CII로 유발된 관절염에 대한 녹용(鹿茸)약침의 억제효과에 대하여 보고하는 바이다.

  • PDF

Development of Precision Measuring Systems for Structural Deformation Measurements (구조물 변형관측을 위한 정밀측량시스템의 개발)

  • 김병국;최정민
    • Spatial Information Research
    • /
    • v.7 no.1
    • /
    • pp.63-79
    • /
    • 1999
  • In this research, the operational principle and the internal algorithm of theodolite measuring systems are studied and coded for a new software, and the feasibility of the laser system for the above mentioned usage is studied by simulation set-up of the system in the laboratory environment, and for the theodolite system modules for the communication between theodolite and computer is implemented, the data collection and storage, the simultaneous photogrammetric ' bundle ' adjustment for the theodolite position and the target points are coded, compiled and tested. for the simulation set-up of the laser system extensive studies on laser sources and laser detectors are performed, the system composition for the system simulation in the laboratory environment is studied and implemented, and the beam fluctuation due to the environmental changes in the course of the laser beam, such as changes in current of wind or in temperature is experimented. According to Experiment on the Source of 17 meters interval and the Detector, Laser beam is almost doesn't depend on air How, but it is effected by variations of temperature and light. Selecting cloudy day and time without change of temperature, it was realized that it is possible to perform deformation measurement more than approximately 2mm precision.precision.

  • PDF