• Title/Summary/Keyword: 종이 열교환기

Search Result 47, Processing Time 0.025 seconds

Analysis of flow and heat transfer in internally finned tube (내부 핀이 부착된 열교환기의 유동장해석)

  • Jeong Ho-Eyoul;Jeong Jae-Tack;Ko Hyung-Jong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.11a
    • /
    • pp.139-144
    • /
    • 1999
  • There have been many studies for heat transfer enhancement. Particularly, the study of flow in heat exchangers which have fin device has been main theme in heat transfer area. Practically, the circular tube which has internal fins is widely used for developing heat transfer rate. In this study, flow and heat transfer analysis of the circular tube with fins are investigated. The height and the number of fins are arbitrary. The flow field is assumed to be laminar. The conformal mapping is used for analytic solution of the laminar flow field. Discretization of governing equation, namely, FDM was used for numerical analysis. The velocity field, flow rate and shear stress are calculated for some numbers of fins in circular tube and for some heights of fin. Temperature fields are plotted along the tube length. It can be shown that the numerical solution agrees with the analytical solution.

  • PDF

Development of Tube Quality Trend Analysis System using Non-Destructive Testing Information (비파괴검사정보를 활용한 Tube 건전성 추이분석 시스템 개발)

  • Shin, Jin-Ho;Song, Jae-Ju;Jang, Mun-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.224-226
    • /
    • 2001
  • 원자력발전소에서는 수많은 Tube로 구성된 증기발생기와 열교환기를 정기적으로 와전류를 이용하여 비파괴검사를 수행한다. 와전류는 재료의 재질, 결함, 이종금속, 형상변화 등에 의해 그 발생상태가 다르기 때문에 검출용 코일에서 얻어진 신호성분을 해석함으로써 재료의 비파괴검사가 가능하다. 본 논문에서는 비파괴검사정보를 추출하고 변환 처리하는 과정과 비파괴검사정보를 Tubesheet에 Mapping 처리하는 기능, 검사주기 및 기기별로 비파괴검사정보를 비교 분석할 수 있는 기능, 하나의 Tube에 대한 결함깊이별, 결함진폭별 결함성장률 현황 등 Tube의 건전성을 평가할 수 있는 추이분석 자료를 제공하는 시스템의 설계와 구현에 대한 개발 결과를 소개한다.

  • PDF

Performance Characteristics of Type II LiBr-H2O Absorption Heat Pump in Accordance with the Refrigerant Heat Exchanger Configuration (냉매 열교환기 구성방법에 따른 제 2종 흡수식 히트펌프의 성능 특성 변화에 관한 연구)

  • Lee, Chang Hyun;Yoon, Jun Seong;Kim, In Gwan;Kwon, Oh Kyung;Cha, Dong An;Bae, Kyung Jin;Kim, Min Su;Park, Chan Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.373-384
    • /
    • 2017
  • The objective of this study was to determine the effect of refrigerant heat exchanger on the performance of type II absorption heat pump performance using numerical analysis. Two heat exchange installation methods were used: solution to refrigerant and waste hot water to refrigerant. These methods were compared to the standard model of hot water flow without using refrigerant heat exchanger. When waste hot waters were bypassed to refrigerant heat exchanger, COP was not affected. However, steam mass generation rates were increased compared to those of the standard model. When solutions were bypassed to the refrigerant heat exchanger, results were different depending on the place where the solution rejoined. COP and steam mass generation rates were lower compared to those when waste heat water was passed to refrigerant heat exchanger. Thus, it is possible to obtain higher steam mass generation rates by using waste water and installing refrigerant heat exchanger.

Experimental Study on Coating Corrosion Characteristics of Heat Exchanger for Sea Water (해수용 열교환기의 코팅 부식특성 실험연구)

  • Kwon, Young-Chul;Kim, Ki-Young;Huh, Cheol;Cho, Meang-Ik;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4117-4123
    • /
    • 2013
  • In the present study, coating corrosion characteristics of the heat exchanger for sea water are experimentally investigated. Coating types by a teflon, an electrodeposition and a ceramic+silicon were tested and compared with the corrosion characteristics of an aluminum. For the acceleration of corrosion by sea water, the temperature of sea water $70^{\circ}C$ and the concentration of salt 3.5% were considered. And the specimens were immersed in sea water during 9 weeks. Coating corrosion characteristics were measured by using the impedance method and SEM. Experimental results showed that polarization resistances obtained from Bode plot were related to the corrosion resistance of coating types, and the corrosion resistance of double coating were maintained during 4 weeks. From SEM photograph, we saw that blisters was generated on the interface between metal and coating.

Performance analysis of an organic Rankine cycle for ocean thermal energy conversion system according to pinch point temperature difference (핀치포인트온도차에 따른 해양온도차발전용 유기랭킨사이클의 성능분석)

  • Kim, Jun-Seong;Kim, Do-Yeop;Kang, Ho-Keun;Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.476-483
    • /
    • 2016
  • An organic Rankine cycle for ocean thermal energy conversion system is a generating cycle using the temperature difference between surface water and deep water of the ocean. The working fluid is an important factor in the thermodynamic performance of an organic Rankine cycle. There is pinch point analysis as thermodynamic analysis of an organic Rankine cycle. This study performed a thermodynamic performance analysis according to variation in the pinch point temperature difference in heat exchangers and variation of outlet temperature of heat source and heat sink. It analyzed the thermodynamic performance by applying seven types of simple working fluids in a simple Rankine cycle for ocean thermal energy conversion that was designed according to pinch point analysis. As a result of the performance analysis, cycle irreversibility and total exergy destruction factor more decreased, and second law efficiency more increased in the lower pinch point temperature difference and temperature variation of heat source and heat sink in heat exchangers. In addition, the irreversibility changed greatly at a point that occurred in the thermodynamic variation. Among the selected working fluids, RE245fa2 showed the best thermodynamic performance, and the performance of all working fluids was observed to be similar. It needs a strict theoretical basis about diverse factors with thermodynamic performances in selecting heat exchangers and working fluids.

A Study on the Physical Characteristics of Grout Material for Backfilling Ground Heat Exchanger (지중 열교환기용 뒤채움재의 물리적 특성 연구)

  • Choi, Hang-Seok;Lee, Chul-Ho;Choi, Hyo-Pum;Woo, Sang-Baik
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.1
    • /
    • pp.37-49
    • /
    • 2008
  • A geothermal heat pump system is a preferable alternative energy system in Korea because it uses the heat energy of the earth, which is environmentally friendly and inexhaustible. In order to characterize the thermal conductivity and viscosity of grout materials used for backfilling ground heat exchangers, nine bentonite grouts, one marine clay from Boryung, and cement grouts adapted in the United State have been considered in this study. The bentonite grouts indicate that the thermal conductivity and viscosity increase with the content of bentonite or filler (silica sand). In addition, material segregation can be observed when the viscosity of grout is relatively low. The marine clay turns out to be unsuitable for backfilling the ground heat exchanger due to its insufficient swelling potential. The saturated cement grouts appear to possess much higher thermal conductivity than the saturated bentonite grouts, and the reduction of thermal conductivity in the cement grouts after drying specimens is less than that in the case of the bentonite grouts. Maintaining the moisture content of grouts is a crucial factor in enhancing the efficiency of ground heat exchangers.

Construction and Tests of the 0.4 MW Class Enhanced Huels Type Plasma System

  • Kim, Min-Ho;Lee, Mi-Yeon;Choe, Chae-Hong;Kim, Jeong-Su;Seo, Jun-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.150-150
    • /
    • 2012
  • 본 연구에서 개발된 Enhanced huels형 플라즈마 발생장치는 초음속 공기 플라즈마 환경에 대한 열 보호 물질의 개발과 시험평가를 위한 지상 시뮬레이션 시험을 목적으로 개발되었다. Enhanced Huel형 플라즈마 토치는 고출력에도 불구하고 전극 부식에 의한 오염도를 최소화할 수 있고, 일반적인 직류 토치로는 얻을 수 없는 초고엔탈피 플라즈마 열유동을 얻을 수 있는 특징이 있다. 구축된 장치는 최대 직류 전력 1,200 kW까지의 출력 제공이 가능한 DC 전원과 플라즈마 토치, 플라즈마의 진단계측 및 재료 시험 수행이 가능한 진공쳄버, 플라즈마를 기체로 회복시켜주기 위한 디퓨저, 디퓨저를 빠져나오는 초고온 열 유동으로부터 열을 제거하기 위한 열교환기, 쳄버 전체의 압력을 제어하기 위한 진공 장치, 후처리 시스템, 가스 공급부 시스템, 냉각수 공급 시스템으로 구성되어 있다. 또한 플라즈마 진단계측장비로는 enthalphy 측정시스템과 각 종 열유속 측정 탐침기, pyrometers, 분광계, 적외선 카메라, 고속 카메라를 갖추고 있다. 시운전 결과 토치 공급전력 412 kW, 공기공급 12.31 g/s , 토치 내부압력 4.14 bar의 운전조건에서 62%의 효율로 플라즈마 엔탈피 16.7 MJ/kg의 성능을 얻었다.

  • PDF

Heat Transfer Characteristics and Pressure Drop in Straight Microchannel of the Printed Circuit Heat Exchangers (직관 마이크로채널 PCHE의 열전달특성 및 압력강하)

  • Kim, Yoon-Ho;Seo, Jung-Eun;Choi, Young-Jong;Lee, Kyu-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.12
    • /
    • pp.915-923
    • /
    • 2008
  • The performance experiments for a microchannel printed circuit heat exchanger (PCHE) of high-performance and high-efficiency on the two technologies of micro photo-etching and diffusion bonding were performed in this study. The microchannel PCHE were experimentally investigated for Reynolds number in ranges of 100 $\sim$ 700 under various flow conditions in the hot side and the cold side. The inlet temperatures of the hot side were conducted in range of $40^{\circ}C\;{\sim}\;50^{\circ}C$ while that of the cold-side were fixed at $20^{\circ}C$. In the flow pattern, the counter flow was provided 6.8% and 10 $\sim$ 15% higher average heat transfer rate and heat transfer performance than the parallel flow, respectively. The average heat transfer rate, heat transfer performance and pressure drop increases with increasing Reynolds number in all the experiment. The increasing of inlet temperature in the experiment range has not an effect on the heat transfer performance while the pressure drop decrease slightly with that of inlet temperature. The experimental correlations to the heat transfer coefficient and pressure drop factor as a function of the Reynolds number have been suggested for the microchannel PCHE.

Development of heat exchanger by the utilization of underground water. I - Design for plat fin tube - (지하수 이용을 위한 열교환기 개발. I - 냉각핀의 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.119-127
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger, parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. of The registration design : 0247164, by Korean Intellectual property Office). The fin of exchanger was design of the granulated surface for minimizing fouling factor and dew forms, and also placed parallel to the tube in order to minimized the resistance of flows. 1. Aloo-heat was designed to have 0.03m for inside diameter, 0.036m for outside diameter of tube, 0.0012m for thickness of fin and 0.032m for length of plat fin. 2. t was also designed to have 1.5248m2/m for outside area of heat transfer, 0.0942m2/m for inside area contacting hot liquid, and the ratio (Ra) was 16.1869. 3. Efficiency of the fin was 93 percentage when fin length was 0.032m, and the fin thickness satisfied equation $\frac{h{\rho}}{k}$< 0.2 when it was 0.0012m. 4. According to the performance test of Aloo-heat, as the temperature and rate increased, the heating value also increased, heating value was 504kJ/h·m and 6,048kJ/h·m when it was 60℃, 10 𝑙/min and 80℃, 40 𝑙/min respectively. 5. The test of heating value was confident, because correlation value(R2) was 0.9898 for the temperature and 0.9721 for flow rate of hot liquid, respectively.

BGK 수치기법을 이용한 로켓 노즐 내의 유동장 해석

  • 신동신;이재성
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.16-16
    • /
    • 2000
  • 충격파를 포함하는 초음속 유동을 해석하는 수치해법 중에서 많이 사용되어진 것은 엄밀 및 근사 리만 해법과 플럭스 분할 기법들로서 이들은 Euler 방정식에 기반을 두고 선형 또는 비선형파의 상호작용을 풍상 차분법으로 기술하는 방법들이다. 이러한 수치기법들은 과거 광범위하게 사용되어 왔으나 최근 여러 가지 단점이 발견되었다. 이와 같은 문제점을 극복하고자 입자의 통계적인 운동을 기술하는 기체 운동론에 근거하여 BGK 수치기법이 제시되었다. 이는 비충돌 볼츠만 방정식으로부터 입자의 수준에서 플럭스 분할 기법 형태의 풍상차분법을 구현하는 것으로 볼츠만 방정식의 충돌항을 BGK 모델로 대치하고 이것의 적분해로부터 수치 플럭스를 구한다. 이 수치기법은 기존의 리만해법에 비하여 수치적으로나 물리적으로 매우 타당한 성질인 강건성, 정확성, 엔트로피 조건, 양수보존성 등을 가지고 있음이 밝혀졌다. 이와 같은 수치기법을 사용하여 로켓 노즐 내의 아음속, 천이음속, 초음속에서의 유동장 해석을 위한 프로그램을 작성하였다. 시간 적분에 대하여는 정상 상태의 계산을 위하여 내재적 시간 적분 방법을 사용하였으며, 공간 이산화 방법으로는 임의의 제어체적에 대하여 적분형 보존 방정식을 적용하는 유한 체적법을 사용하였다. 초음속 입구 유동과 출구에서 초음속과 저음속 유동의 두가지 경우를 고려하여 얻은 결과를 기존의 연구 결과와 비교하여 본 결과 잘 일치하였다. 입구 유동이 저음속이고 출구 유동이 초음속인 경우에 대하여도 해석결과가 실험결과와 잘 일치하였다. 상대적으로 낮은 온도, 압력 조건과 높은 온도, 압력 조건을 가지는 고체 로켓 모터 노즐 내의 유동을 해석하였다. 이들 해석 결과를 전압, 전온도로 표준화시킨 결과 서로 일치하였으며, 파라서 저온, 저압에서 얻은 결과도 표준화시킬 경우, 고온, 고압에서도 사용될 수 있음을 알 수 있었다.의 영향에 초점을 맞추었다.다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14) 식도경 시행회수는 1회가 17례(54.8%), 2회가 9례(29.0%), 3회 이상이 5례(16.1%)였다.EX>$IC_{50}$/ 값이 210 $\mu\textrm{g}$<

  • PDF