• Title/Summary/Keyword: 종양 지표

Search Result 167, Processing Time 0.028 seconds

TNF-α in the Pleural Fluid for the Differential Diagnosis of Tuberculous and Malignant Effusion (결핵성 및 악성흉수의 감별에 있어 흉수 내 TNF-α의 유용성)

  • Kim, Hye Jin;Shin, Kyeong Cheol;Lee, Jae Woong;Kim, Kyu Jin;Hong, Yeong Hoon;Chung, Jin Hong;Lee, Kwan Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.625-630
    • /
    • 2005
  • Background : Determining the cause of an exudative pleural effusion is sometimes quite difficult, especially between malignant and tuberculous effusions. Twenty percent of effusions remain undiagnosed even after a complete diagnostic evaluation, including pleural biopsy. The activity of tumor necrosis factor-alpha (TNF-${\alpha}$), which is the one of proinflammatory cytokines, is increased in both infectious and malignant effusions. The aim of this study was to investigate the diagnostic efficiency of TNF-${\alpha}$ activity in distinguishing tuberculous from malignant effusions. Methods : 46 patients (13 with malignant pleural effusion, 33 with tuberculous pleural effusion) with exudative pleurisy were included. TNF-${\alpha}$ concentrations were measured in the pleural fluid and serum samples using an enzyme-linked immunosorbent assay (ELISA). In addition, TNF-${\alpha}$ ratio (pleural fluid TNF-${\alpha}$ : serum TNF-${\alpha}$) was calculated. Results : TNF-${\alpha}$ concentration and TNF-${\alpha}$ ratio in the pleural fluid were significantly higher in the tuberculous effusions than in the malignant effusions (p<0.05). However, the serum levels of TNF-${\alpha}$ in the malignant and tuberculous pleural effusions were similar (p>0.05). The cut off points for the pleural fluid TNF-${\alpha}$ level and TNF-${\alpha}$ ratio were found to be 136.4 pg/mL and 6.4, respectively. The sensitivity, specificity and area under the curve were 81%, 80% and 0.82 for the pleural fluid TNF-${\alpha}$ level (p<0.005) and 76%, 70% and 0.72 for the TNF-${\alpha}$ ratio (p<0.05). Conclusion : We conclude that pleural fluid TNF-${\alpha}$ level and TNF-${\alpha}$ ratio can distinguish a malignant pleural effusion from a tuberculous effusion, and can be additional markers in a differential diagnosis of tuberculous and malignant pleural effusion. The level of TNF-${\alpha}$ in the pleural fluid could be a more efficient marker than the TNF-${\alpha}$ ratio.

Telomerase Activity in Primary Lung Cancers (원발성 폐암에 있어서 Telomerase 활성도에 대한 연구)

  • Yun, Sang-Myung;Kwak, Kyung-Rok;Hwang, Jee-Yoon;Park, Sam-Seok;Jeon, Doo-Soo;Kim, Cheol-Min;Lee, Min-Ki;Park, Soon-Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.195-203
    • /
    • 1999
  • Background: Telomerase enzyme activity is not detected in most normal cells, a phonomenon believed to be associated with limitations on cellular proliferation. Since this activity is detected in nearly all human tumor, including lung cancers, it has been suggested that telomerase activation may be coupled to acquisition of malignant phenotype. In this study, we determined whether telomerase activity was associated with tumor pathologic stage. Methods: Primary tumor specimens obtained by bronchoscopic biopsies from 33 patients were analyzed. Telomerase activity was measured by means of a modified Telomeric Repeat Amplication Protocol(TRAP) assay. Results: Telomerase activity was detected in 23 of the 27 non-small-cell lung cancer and 5 of 6 small-cell lung cancer. A few primary tumors did not appear to have detectable telomerase activity. Positive associations were found between the telomerase-positive rate and tumor stage(p<0.05). Conclusion: High telomerase activity is detected frequently in primary lung cancers that exhibit high tumor cell proliferation rates and advanced pathologic stage.

  • PDF

Usefulness of the Pleural Fluid Adenosine Deaminase with Lymphocyte/Neutrophil Ratio in the Diagnosis of Tuberculous Pleurisy for a Region of Intermediate Prevalence of Tuberculosis (중등도 결핵 유병률 지역에서 결핵성흉막염 진단에 있어 흉수 아데노신 탈아미노효소와 림프구/호중구 비의 유용성)

  • Kim, Chang Hwan;Mo, Eun Kyung;Park, Sung Hoon;Hwang, Yong Il;Jang, Seung Hun;Park, Yong Bum;Kim, Cheol Hong;Kim, Dong-Gyu;Lee, Myung Goo;Hyun, In Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.6
    • /
    • pp.437-443
    • /
    • 2009
  • Background: The aim of this study was to consider the significance of pleural fluid adenosine deaminase (ADA) activity combined with lymphocyte/neutrophil (L/N) ratio in the diagnosis of tuberculous pleurisy (TBpl) in a region of intermediate prevalence of tuberculosis (TB). Methods: We collected data from 388 patients with exudative pleural effusions. The final diagnoses were compared to the results from our diagnostic method using pleural fluid ADA and L/N ratio. Results: 108 patients had a final diagnosis of TBpl; 102 cases had high levels of ADA ($\geq$40 IU/L). When we considered ADA $\geq$40 IU/L as a diagnostic criterion, the sensitivity was 94.4%, specificity 87.5%, and posttest posttest probability 74.5%. However, when we considered ADA $\geq$40 IU/L combined with the L/N ratio $\geq$0.75 as a diagnostic criterion, the specificity and post-test probability were rose to 97.5% and 93%, respectively. The other causes of high ADA and L/N ratios were lymphoma and metastatic carcinoma, but mass-like lesions were found on the chest radiographs or CT scans. Conclusion: To evaluate the causes of exudative pleural effusions in a region of intermediate prevalence of tuberculosis, we recommend measuring the pleural fluid ADA and L/N ratio first. If the result is high and malignancies are not suspected, it may be diagnostic of TBpl.

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

Evaluation of the Accuracy for Respiratory-gated RapidArc (RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The position of the internal organs can change continually and periodically inside the body due to the respiration. To reduce the respiration induced uncertainty of dose localization, one can use a respiratory gated radiotherapy where a radiation beam is exposed during the specific time of period. The main disadvantage of this method is that it usually requests a long treatment time, the massive effort during the treatment and the limitation of the patient selection. In this sense, the combination of the real-time position management (RPM) system and the volumetric intensity modulated radiotherapy (RapidArc) is promising since it provides a short treatment time compared with the conventional respiratory gated treatments. In this study, we evaluated the accuracy of the respiratory gated RapidArc treatment. Total sic patient cases were used for this study and each case was planned by RapidArc technique using varian ECLIPSE v8.6 planning machine. For the Quality Assurance (QA), a MatriXX detector and I'mRT software were used. The results show that more than 97% of area gives the gamma value less than one with 3% dose and 3 mm distance to agreement condition, which indicates the measured dose is well matched with the treatment plan's dose distribution for the gated RapidArc treatment cases.

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Predictability of Impending Events for Death within 48 Hours in Terminal Cancer Patients (말기암환자에서 임박사건 간 48시간 임종예측도 비교)

  • Hwang, In-Cheol;Choi, Chung-Hyun;Kim, Kyoung-Kon;Lee, Kyoung-Shik;Suh, Heuy-Sun;Shim, Jae-Yong
    • Journal of Hospice and Palliative Care
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2011
  • Purpose: Recognition of impending death is crucial not only for efficient communication with the caregiver of the patient, but also determination of the time to refer to a separate room. Current studies simply list the events 'that have already occurred' around 48 hours before the death. This study is to analyze the predictability of each event by comparing the time length from 'change' to death. Methods: Subjects included 160 patients who passed away in a palliative care unit in Incheon. The analysis was limited to 80 patients who had medical records for the last week of their lives. We determined 9 symptoms and 8 signs, and established the standard of 'significant change' of each event before death. Results: The most common symptom was increased sleeping (53.8%) and the most common sign was decreased blood pressure (BP) (87.5%). The mean time to death within 48 hours was 46.8% in the case of resting dyspnea, 13.6% in the ease of low oxygen saturation, and 36.9% in the case of decreased BP. The symptom(s) which had the highest positive predictive value (PV) for death within 48 hours was shown to be resting dyspnea (83%), whereas the combination of resting dyspnea and confusion/delirium (65%) had the highest negative PV. As for the most common signs before death within 48 hours, the positive PVs were more than 95%, and the negative PV was the highest when decreased BP and low oxygen saturation were combined. The difference in survival patterns between symptoms and signs was significant. Conclusion: The most reliable symptoms to predict the impending death are resting dyspnea and confusion/delirium, and decline of oxygen saturation and BP are the reliable signs to predict the event.

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Clinical Observation of Pleural Effusion (늑막염의 임상적 고찰)

  • Kim, Choon-Sup;Ju, Kee-Joong;Lee, Chang-Hwan;Park, Sung-Min;Shim, Young-Woong;Song, Kap-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.584-594
    • /
    • 1993
  • Background: Among the respiratory diseases, there are a lot of cases of pleural effusion. The most common cause is tuberculosis. But the other cause such as lung malignancy is in an increasing tendency because of the development of diagnostic procedure, the decrease of the prevalence of the tuberculosis and the increase of the longevity. We need to know the accurate diagnosis as soon as possible for the correct therapy. Method: A clinical observation was made on 315 cases of pleural effusion seen at Pusan Adventist Hospital, from Jan, 1989 to Dec, 1992. For diagnostic procedure, thoracentesis, lymph node biopsy, bronchoscopy and percutaneous biopsy of the parietal pleura with Cope needle were performed. The following are parameters used in seperating the exudate from the transudate: pleural protein 3.0 g/dl, pleural protein/serum protein ratio 0.5, pleural LDH 200 IU, pleural LDH/serum LDH ratio 0.6, pleural cholesterol 60 mg/dl and pleural cholesterol/serum cholesterol ratio 0.3. Each parameters were compared, and misclassified rate and diagnostic efficiency were calculated. Results: The most common cause of exudate pleurisy was tuberculosis (82.3%) and malignancy was next (12.2%). The chief complaints of pleural effusion were noted as dyspnea (58.7%), chest pain (54.9%), coughing (50.2%) and fever (36.2%). Location of pleural effusion was noted as right side (51.4%), left side (41.3%) and both sides (7.3%). Amount of pleural effusion of the chest X-ray was minimum (46.8%), moderate (40.5%) and maximum (12.7%). Misclassified rates for each parameters in seperating the exudates from the transudates were as follows; protein: 5.2%, pleural protein/serum protein:7.6%, LDH: 13.9%, pleural LDH/serum LDH: 6.9%, cholesterol: 8.0%, pleural cholesterol/serum cholesterol: 5.6%. On the pleural biopsy, the tuberculosis granuloma was 60.8%, malignancy was 13.6%, infection was 2.3% and nonspecific inflammatory reaction was 23.3%. Conclusion: on the basis of the above results, the most common cause of exudative pleurisy was tuberculosis. We think that the plerual cholesterol/serum cholesterol ratio is the most useful supportive parameter in separating the exudates from the transudates. For accurate diagnosis, the pleural biopsy is the first procedure and repeated pleural biopsy of nonspedcific inflammatory reaction is required.

  • PDF

Postirradiation Changes of White Blood Cells and Lymphocyte Subpopulations in Cancer Patients (암환자의 방사선치료에서 흉부 및 전골반강 조사직후 백혈구 및 림프구아헝 변화에 대한 연구)

  • Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun;Nah, Byung-Sik;Noh, Young-Hee
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.53-59
    • /
    • 1996
  • Purpose : Radiation-induced alteration in the immune function is well known phenomenon in cancer patients. Our purpose is to evaluate the extent of immune suppression immediately after mediastinal or pelvic irradiation, which include significant volume of active bone marrow in adults. Materials and Methods'48 cancer patients with mediastinal(N=29) and pelvic irradiation(N=19) were the basis of this analysis. Age ranged from 36 to 76 and mean and median value was 57 years, respectively Sex ratio was 1.3(M: F=27/21). The immunological parameters were the complete blood cell(CBC) with differential cell(D/C) count, T cell subset(CD3, CD4, CD8 CDl9), NK cell test(CDl6, CD56), and serum immunoglobulin(IgG, IgA, IgM) level. Results : The mean value of white blood cell(WBC) was reduced from 7017 to 4470 after irradiation(p=0.0000). In the differential count, the number of lymphocyte, neutrophil, and basophil was markedly reduced with statistical significance(p<0.01) and the number of monocyte was not changed and, on the contrary, that of eosinophil was increased by irradiation. In the lymphocyte subpopulation analysis, the number of all subpopulations, CD3(T cell), CD4(helper T cell), CD8(suppressor T cell), CDl6(NK cell), CDl9(B, cell) was reduced with statistical significance. The mean ratio of CD4 to CD8 in all patients was 1.09 initially and reduced to 0.99 after radiotherapy(p=0.34) , but the proportional percentage of all subpopulations was not changed except CD19(B cell) after irradiation. In the immunoglobulin study, initial values of Ig G, Ig A, and Ig M were relatively above the normal range and the only Ig M was statistically significantly reduced after radiotherapy(p=0.02). Conclusion : Mediastinal and pelvic irradiation resulted in remarkable suppression of lymphocyte count in contrast to the relatively good preservation of other components of white blood cells. But the further study on the functional changes of lymphocyte after radiotherapy may be necessary to conclude the effects of the radiation on the immunity of the cancer Patients.

  • PDF