• Title/Summary/Keyword: 존의(存宜)

Search Result 56, Processing Time 0.021 seconds

Evaluation of the Smear Zone by Numerical Analysis Method (수치해석에 의한 스미어 존 평가)

  • Kang, Yun;Nam, Yelwoo;Lee, Seombeom;Kim, Hongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • The vertical drain method recently being used in Korea is divided into the sand drain method, the pack drain method, the paper drain method, and the PBD method according to the drainage. However, these methods generate the disturbed zone called the smear zone when the drainage is penetrated into the in-situ ground. The characteristics of the smear zone generated cause the problems that the coefficient of permeability decreases and the consolidation time becomes longer than expected in the design. Although the size of the smear zone is a very important factor directly influencing the degree of consolidation, in the existing studies, the general value for the size of the smear zone proposed has been used in the design. However, the size of the smear zone proposed by the existing studies cause a loss of economical efficiency because of the inaccuracy of the design. Hence, in this study, the characteristics on the size of the smear zone were analyzed by carrying out the three dimensional numerical analysis and the method to determine the conversion size of the smear zone considering the change of the coefficient of permeability was proposed in order to consider the change of the coefficient of permeability in the actual design.

  • PDF

An Evaluation of Smeared Zone Due to Mandrel Penetration (맨드렐 관입에 기인하는 스미어 존의 평가)

  • 박영목
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.217-225
    • /
    • 2003
  • An experimental study was conducted to evaluate the smeared effect due to mandrel penetration into soft ground for a vertical drain installation. Laboratory tests were performed to investigate the formation of a smear zone, the variations of strength, and the consolidation characteristics in the disturbed zone using two types(CL at Yangsan site and OH at Pohang site) of soft clayey soils. The smear zone effect was evaluated focusing on mandrel shape, mandrel size, penetration speed, and ground condition. Based on laboratory test results, the diameter of the smear zone$(d_s)$ ranged from 3.08 and 3.92 times that of mandrel$(d_m)$. It was also found that the $(d_s/d_m)$ value of the circular shape of the mandrel is smaller than those of square and rectangular shapes. The value of $(d_s/d_m)$ decreased with larger mandrel size, lower penetration speed in the CL soil, and higher penetration speed in the OH soil. However, natural water content was minimally affected by $(d_s/d_m)$. Respectively, the coefficients of horizontal consolidation$(C_{hs})$ and horizontal Permeability$(K_s)$ of smear zone ranged from 0.81 to 0.87 times, and 0.73 to 0.83 times those of the undisturbed zone. Based on this study, the values of $C_{hs}, K_s$ and unconfined compressive strength$(q_{us})$ in the smear zone were the lowest at close vicinity of the mandrel and increased linearly with distance from the mandrel. Further, the $(q_{us})$ varied from 0.5 to 0.9 times that of the undisturbed zone strength.

An Experimental Study on the Evaluation of Smear Effect Considering In-situ Conditions (현장여건을 고려한 스미어 영향 평가에 관한 실험적 연구)

  • Park, Yeong-Mog
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.85-94
    • /
    • 2012
  • Evaluation of the smear effect caused by mandrel penetration into soft ground for a vertical drain installation is very important to predict the consolidation time of soft ground improvement. 30 kinds of laboratory model tests considering in situ conditions were conducted to investigate the formation of a smear zone and the decrease of coefficient of permeability in the disturbed zone. Three types(C(clay):M(silt)=1:1, 0.5:0.5, and 0:1) of reconstituted samples were used for 3 dimensional smear zone test. An experimental study was performed focusing on length of mandrel penetration, mandrel shape and size, earth pressure, and ground condition(unit weight and grain size distributions). Laboratory test results show that the length of mandrel penetration is the most critical factor for the formation of smear zone. As a result, the ratio between diameter of the smear zone($d_s$) and that of mandrel($d_m$) at field using long mandrel becomes larger than conventional $d_s/d_m$. The ratio between $d_s$ and $d_m$ ranges from 1.89 and 2.48 with the sample at C:M=1:0. It was also found that the $d_s/d_m$ value with the round shape of the mandrel is smaller than that of diamond one. The value of $d_s/d_m$ decreased with larger mandrel size, lower unit weight, and higher earth pressure. However, higher silt content led to increase of $d_s/d_m$. The ratio between coefficient of horizontal permeability in the smear zone($k_{hs}$) and that of undisturbed zone($k_{ho}$) ranged from 0.70 to 0.85. The test results imply that factors and values affecting $k_{hs}/k_{ho}$ show similar tendency with $d_s/d_m$.

A Burn-in Test System with Dynamic Bone Allocation (동적 존 할당이 가능한 번인 시험 시스템)

  • Oh, Sam-Kweon;Shin, Joong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.75-80
    • /
    • 2009
  • Bum-in test is one for eliminating semiconductor devices that are subject to early failures and other operational problems; it is usually carried out on the devices by imposing severe test conditions such as elevated voltages, temperatures, and time. In order for such a test to be performed, each burn-in board having devices to be tested, needs to be inserted into a corresponding slot. A set of such slots is called a zone. The slots comprising a zone can only have the burn-in boards with the devices of the same type. In order to test many different types of semiconductor devices, it is desirable to build a burn-in test system to have as many zones as possible. A zone controller controlling a zone, is a device that performs a burn-in test and collects test results. In case of existing systems, each zone controller takes care of a zone that consists of a fixed number of slots. Since a zone controller is, in most cases, embedded into a workstation that controls the overall testing process, adding new zone controllers is restricted by the spaces for them. As a way to solve or alleviate these problems, a dynamic zone system in which the number of slots in a zone can be dynamically allocated, is presented. This system maximizes the efficiency of system utilization, by altering the number of slots and hence minimizing the idle slots of a zone. In addition, all the test operations being performed must be aborted for maintenance in existing systems. In dynamic zone systems, however, a separate and independent maintenance is allowed for each slot, as long as the main power supply system has no problem.

Characteristics of the Smear Zone by Vertical Drain of Low Plasticity on Soft Ground (저소성 연약지반에서의 스미어 존 특성 평가)

  • Kang, Yun;Baek, Sungchul;Kim, Hongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.27-33
    • /
    • 2007
  • The vertical drain method recently being used in Korea is one of the popular soft ground improvement methods, and it is divided into the sand drain method, the pack drain method, the paper drain method, and the PBD method according to the drainage. However, these methods generate the disturbed zone called the smear zone when the drainage is penetrated into the in-situ ground. The characteristics of the smear zone generated cause the problems that the coefficient of permeability decreases, and then the consolidation time in the design becomes longer than expected. Even though the coefficient of horizontal consolidation and the coefficient of permeability in the smear zone are very important design factors directly influencing the degree of consolidation, in the existing studies, these coefficients have been empirically derived by the coefficient of vertical consolidation and used for the design. However, in case that these coefficients derived by the coefficient of vertical consolidation are applied to the actual design, a loss of the duration of construction and a loss of economical efficiency can be happened because of the inaccuracy of the coefficient of horizontal consolidation and the coefficient of permeability. Hence, in this study, in order to understand such influence, the laboratory test was carried out so as to reasonably determine the coefficient of permeability and the coefficient of consolidation in diverse ground conditions. Then, the range of smear effect on clay and silt was estimated with monitoring data through the laboratory test.

  • PDF

이중파장 광섬유 브래그 격자센서(FBG)를 이용한 고해상도 광대역 측정

  • Ali, Mumtaz;Sin, Seo-Yong;Jeong, Tae-Gyeong;Lee, Sang-Hyeon;Kim, Eun;Ju, Gwan-Sik
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.221-222
    • /
    • 2009
  • 이 논문에서는 기존의 FBG 광센서와는 달리 이중파장 구조를 갖는 FBG 센서를 제안하여 기 존의 FBG 센서가 측정할 수 있는 범위를 획기적 으로 증대시킴을 보이고자 한다. 고해상도의 광범 위한 지역 측정은 두 가지의 광대역 광원을 이용 하는 매트릭스 구조의 FBG를 이용해 구성하였으며, 두 광원을 사용하는 통합시스템은 도파로 열격자(AWG)로 구성되어 있다.

  • PDF

Endpoint Detection in the Car Noise Environment for Speech Recognition (음성인식을 위한 자동차 소음환경에서의 끝점 검출)

  • 서동권;신원호;양태영;김원구;윤대희
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.76-79
    • /
    • 1998
  • 소음이 존재하지 않는 환경에서는 에너지 파라메터만으로도 정확한 끝점 검출을 수 행할 수 있으나 신호대 잡음비가 0dB에 가까운 자동차 환경에서는 끝점 검출이 거의 불가 능하다. 본 논문에서는 자동차 소음 환경에서 음성 구간 검출을 위하여 단구간 영교차율과 2∼4kHz의 주파수 영역 에너지를 사용한 끝점 검출 방법을 제안하였다. 제안된 방법과 기 존의 방법의 성능을 DTW를 이용한 단독음 인식 시스템에 적용하여 인식률로 비교하였으 며 제안된 음성 구간 검출 방법을 적용한 경우가 보다 좋은 인식률을 나타내었다.

  • PDF

Design of Neuro Controller for Improving Velocity Control of AC Motor (AC MOTOR의 속도제어 개선을 위한 신경망제어기의 설계)

  • 설재훈;임영도
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1995.10b
    • /
    • pp.243-248
    • /
    • 1995
  • 본 논문에서는 신경회로망의 학습능력을 이용하여 AC 모터의 속도제어에 이용된 기 존의 PI제어기의 문제점을 보완하고자 한다. 기존의 아날로그 PI제어기에서는 각 비례, 적분 파라메타를 개발자가 조정하여 고정하면 부하가 변동될 경우 적응성이 떨어지는 문제점을 안고 있었다. 본 논문에서 제시된 디지털 신경망제어기는 학습을 통해 새로운 환경에 적응 가능하다는 점에 가정하여 설계하고 성능을 비교 평가하였다. 본 논문에서 사용된 신경회로 망의 구조는 신경망중에서 가장 범용적으로 사용되는 다층 퍼셉트론 모델구조를 선택하였 다. 신경망 제어기장치로는 인텔 8097 마이크로 콘트롤러를 이용하였다.

  • PDF

Inelastic Behavior and Design Strength of Panel Zones (패널 존의 비탄성거동과 설계강도)

  • Kim, Dong-Sung;Kim, Kee-Dong;Ko, Man-Gi
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.49-52
    • /
    • 2008
  • The design strength of panel zones, which was based on Krawinkler model, was investigated by comparing it with existing test and FEM results. The design strength overestimates of the strength of panel zones with thick column flange while it matches well with the strength of panel zones with thin column flange. More extensive studies are needed to develop a mathematical model which can properly define the inelastic behavior of panel zones with various column flange thicknesses and to determine a more rational design strength.

  • PDF