• Title/Summary/Keyword: 조형크기

Search Result 138, Processing Time 0.037 seconds

Fractionated Stereotactic Radiotherapy (FSRT) Using Gold Markers : A Comparison of the Isocenter between Multiple Arcs and Static Conformal Beams (금속표지자를 이용한 다중호형 정위방사선치료와 입체조형 정위방사선치료의 회전중심점 비교)

  • 장지영;김기환;김재성;김준상;송창준;김선환;조문준
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • The aim of the study was to assess the isocenter deviation between multiple arcs and conformal beams in frameless FSRT. Forty seven patients received single isocenter radiosurgery or therapy (SRS/T) using available framelss FSRT system from Aug. 1997 to Dec. 2m. In choosing multiple arc FSRT or conformal FSRT, we had considered one of two techniques with respect to tumor size and tumor shape. In multiple arc FSRT, the average and standard deviation (SD) of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.2 mm (SD 0.2) and 0.3 mm (SD 0.2 mm)in the lateral (x), anterior-posterior (y) and cranio-caudal directions (z). In conformal FSRT, the average deviation and SD of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.3 mm(0.2 mm) and 0.4 mm (SD 0.2 mm) in the x, y and z directions. The average spacial deviation ($\Delta$r) was 0.41 mm and 0.54 mm in multiple arcs and conformal beams, respectively. The isocenter deviation using frameless FSRT system was similar value between multiple arcs and conformal beams. In practice, we believed we can select the appropriate treatment technique according to tumor shape and size.

  • PDF

A Study on the Analysis of the Trend of installations Using 3D Printing Technique (3D프린팅 조형설치물 경향분석에 관한 연구)

  • Kim, Ji Min;Lee, Tae Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.52-60
    • /
    • 2021
  • The aim of this study was to derive a new trend by analyzing installations using 3D printing that are out of the limits of size and design according to the trends of developing 3D printing technology. This paper classified the types of installations using 3D printing and analyzed them with two trends: the trend of design and the trend of output. The trends of installations using 3D printing derived from this study are as follows. First, as the implementation of design through an algorithm is accomplished, the transformation appears with the atypical design that is prominent in complex expression. Second, Robotics and FDM 3D Printing is fused, which is changing the existing paradigm. Therefore, the production and utilization of installations using 3D printing proceeded at a faster pace through the interaction between the algorithm design method and freeform 3D printing technology. This study was conducted on installations using 3D printing around the world and played a basic role in the research on the production of installations using 3D printing along with domestic 3D printing technology to be developed in the future. Follow-up studies in various aspects, such as materials and combination methods, will be needed.

A Study on Fashion Design Using Geometric Pattern (기하학적 패턴을 활용한 패션디자인 연구)

  • 김신우;금기숙
    • Journal of the Korean Society of Costume
    • /
    • v.52 no.1
    • /
    • pp.53-67
    • /
    • 2002
  • 자연을 분석함으로써, 얻어진 기하학적 패턴은 이미 자연의 질서를 포함하고 있는 논리적이고 합리적인 기본형이기 때문에 간결하며 시각적으로 명쾌감을 준다. 이러한 기하학적 패턴은 복식 디자인에 있어서 20 세기 이후 여러 디자이너의 작품을 통해 재구성되어 현대적 이미지를 나타내는 중요한 모티브가 되고 있으며, 다양한 기법과 재료로 형성화하여 도입되고 있다. 이에 본 연구는 복식의 문양, 실루엣, 디테일에 사용되고 있는 기하학적 패턴을 연구함으로써 기하학적 패턴의 새로운 조형가치를 고찰하였다. 먼저 기하학의 용어 정의를 하였고 기하학적 패턴의 유형과 표현 기법을 분석하고 정리하여 현대 패션에 나타난 기하학적 패턴의 조형미와 그것을 바탕으로 패션 이미지를 추론해 보았다. 현대 패션에 나타난 기하학 패턴을 분석해 보면 유형으로는 첫째, 기하하적 문양으로 복식디자인에 있어서 주로 평면적인 형태로 많이 나타나지만, 크기가 다르고 동일한 기하학적 패턴을 조합시킴으로서 평면적인 형태에 공간감을 부여하기도 하며, 같은 기하학적 패턴의 표면이라도 배치구조에 의해 직선 혹은 사선으로 지각되므로 전혀 다른 이미지를 주었다. 또한 현대 패션에 나타난 기하학적 패턴이 종류는 세로 스트라이프, 가로 스트라이프, 격자 문양, 원, 사선 스트라이프, 마름모, 사각형, 삼각형 등의 순서로 많이 나타났다. 둘째, 색채는 단색의 복식에 강한 대비가 이루어지는 색상으로 표현되어 역동감과 유연한 운동감을 나타났다. 셋째, 기하학적 실루엣으로 단순한 라인의 형태를 나타내거나 입체적이고 부조적인 형태로 구성되어 전체적인 실루엣으로 사용되어 강한 조형감각을 보여주는데 원형을 이용한 실루엣이 가장 많았으며 사각형을 이용한 실루엣, 삼각형을 이용한 실루엣 순서로 나타났다. 넷째, 기하학적인 디테일로 복식의 어느 한 부분에 장식적으로 사용되거나 입체적 형태로 부출 되어 부조적인 느낌을 주는데 소매에 가장 많이 나타났으며 앞여밈, 칼라, 밑단, 주머니 순서로 장식되었다. 다섯째, 현대 패션에 표현된 기하학적 패턴의 표현기법으로는 프린팅, 퀼팅, piece기법, 패치워크, 엮기, 꼴라쥬, 아플리케 순서로 많이 나타났다. 위의 분석을 토대로 기하학 패턴을 활용한 디자인에 내재된 조형의지는 다음과 같이 정리되었다. 첫째, 기하학적 패턴이 지닌 단순성과 경직성을 완화하기 위하여 여러 가지 패브릭을 조합시켜 입체적인 표면효과로 시각적인 착시효과를 극대화하였다. 둘째, 표현기법은 입체파적 표현주의의 특성의 하나로 복시에 사용되는 소재의 왜곡으로 설명할 수 있으며, 새롭고 실험적인 소재의 도입으로 인해 의외성과 부조화를 유발시키는 통시에 유희직인 일면도 지니는 일종의 그로테스크를 나타냈다. 이상에서 정립된 조형의지를 바탕으로 현대 패션에 나타란 기하학 패턴은 절제된 단순함과 명확성으로 단순미가 유추되었고 강한 색상대비로 인한 시각적 집중효과로 주목성을 가지며 재현이 가능하므로 반복성이 유추되었다. 그리고 표준영역이 없는 창의적 표현으로 풍부한 독창성을 보여주고 있다. 또한 내재된 패션 이미지를 분석해 보면 정확함과 차가움의 의미를 지닌 이지적 이미지와 우주의 질서를 반영하는 상징적 이미지, 복잡한 자연으로부터 간결한 형태로의 경향성이 이루어낸 인공적 이미지를 느낄 수 있었으며, 미래적 이미지와 전통적 이미지의 상반된 개념의 이미지를 같이 내포하고 있음을 추론할 수 있었다. 이와 같이 현대 패션에 표현된 기하학적 패턴은 복식을 조형예술 분야로 확실히 인식시키고 발전시키는 데 중요한 촉매제 역할을 담당하고 있으며 또한 많은 디자이너들에게 창조적 욕구를 불러일으키고 영감을 주는데 중요한 모티브를 제공하고 있다.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Positional Change of the Uterus during Definitive Radiotherapy for Cervix Cancer (자궁경부암의 방사선치료 시 자궁의 크기와 위치 변화)

  • Park, Won;Huh, Seung-Jae;Lee, Jeung-Eun
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.135-142
    • /
    • 2003
  • Purpose: The purpose of this study was to investigate the positional change of the uterus during radiotherapy. Materials and Methods: Between 1997 and 2001, 47 patients received definitive radiotherapy for cervical cancer at the Samsung Medical Center. For each patient, two MRI scans were taken; one before and the other 3$\~$4 weeks after the radiotherapy treatment. In T2 weighted MRI images, the positional change of the uterine was quantified by measuring six quantities; the distance from the cervix os to the isthmus of the uterus (Dcx), the maximum length from the isthmus of the uterus to the uterine fundus (Dco), the maximum vertical distance of the uterine body (Dco-per), the angle between the vertical line and the cervical canal in the sagittal images (Acx), the angle of the uterine corpus from the vertical line in the sagittal plan (Aco-ap), and the relative angle of the uterine corpus from a fixed anatomical landmark in the axial images (Aco-axi). Results: The mean Dcx values, before and during the treatment, were 36.7 and 27.8 mm, respectively. The Dco deviated by more than 10 mm in 14 cases (29.8$\%$). The change in the Acx ranged from 0.1 to 67.8$^{\circ}$ (mean 13.2$^{\circ}$). The Aco-ap changed by a maximum of 84.8$^{\circ}$ (mean 16.9$^{\circ}$). The differences in the Dcx plus the Dco in the smaller (<4 cm) and larger ($geq$4 cm) tumors were 5.3 and 19.4 mm, respectively. With patients less than 60 years old, or with a tumor size larger than 4 cm, the difference in the Acx was statistically significant. Conclusion: The positional changes of the uterus, during radiation treatment, should be considered in the 3DCRT or IMRT treatment planning, particularly in patients under 60 years of age or in those with a tumor size greater than 4 cm in maximum diameter.

Adaptive control of the back bead width in gas metal arc welding process (아크용접에서 이면비드 크기의 적응제어)

  • 부광석;조형석;오준호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.289-294
    • /
    • 1988
  • This paper describes tbe design and implementation of the adaptive controller to maintain the glood weld quality in gas metal arc welding process. The weld torch travel speed and the surface temperature are taken, respectively, as an input and an output of the welding control system. Because of the very complex phenomena of the process, the input-output dynamic model was experimentally identified by AIC (Akiake Information Criterion). Based on the model structure, the explicit model reference adaptive controller is simulated in order to regulate the output tempernture to the desired level.

  • PDF

Estimation of weld pool sizes in GMA welding processes using a multi-layer neural net (다층 신경회로망을 이용한 GMA 용접 공정에서의 용융지 크기의 예측)

  • 임태균;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1028-1033
    • /
    • 1991
  • This paper describes the design of a neural network estimator to estimate weld pool sizes for on-line use of quality monitoring and control in GMA welding processes. The estimator utilizes surface temperatures measured at various points on the top surface of the weldment as its input. The main task of the neural net is to realize the mapping characteristics from the point temperatures to the weld pool sizes through training, A series of bead-on plate welding experiments were performed to assess the performance of the neural estimator.

  • PDF

Throughput Approximation Method for Assembly/Disassembly Production Systems with Finite Buffer (유한용량을 갖는 조립/분해 생산시스템의 산출율 근사적 방법)

  • 백천현;김호균;조형수
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2000.04a
    • /
    • pp.257-260
    • /
    • 2000
  • 본 연구에서는 유한용량을 갖는 조립/분해 생산시스템의 산출율분석을 위한 근사적 방법을 제시한다. 유한용량을 갖는 조립/분해 생산시스템은 상태공간이 매우 크기 때문에 효율적으로 분석하기가 어렵다. 따라서 근사적 방법에서는 조립/분해 생산시스템을 비교적 작은 규모의 상태공간을 갖도록 단순 조런/분해 시스템과 단일 직렬시스템을 갖는 각각의 부분시스템으로 분해한다. 각 부분시스템은 2차 모멘트가 고려된 PH/Ph/1/C 시스템으로 기술되고 수리적 방법에 의해 분석되어진다. 실험결과는 시뮬레이션과 비교되고, 제시된 근사적 방법이 효과적이라는 것을 보여준다.

  • PDF

Control of weld pool sizes in GMA welding processes using neural networks (신경회로를 이용한 GMA 용접 공정에서의 용융지의 크기 제어)

  • 임태근;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.531-536
    • /
    • 1992
  • In GMA welding processes, monitoring and control of weld quality are extremely difficult problems. This paper describes a neural network-based method for monitoring and control of weld pool sizes. First, weld pool sizes are estimated via a neural estimator using multi-point surface temperatures, which are strongly related to the formation of weld pool, and then controlled using the estimated pool sizes. Two types of controllers using the pool size estimator are designed and tested. To evaluate the performance of the designed controllers, a series of simulation studies was performed.

  • PDF

Generation of Running Motion on Complex Terrain (복합 지형에서의 달리기 동작 생성에 대한 연구)

  • Song, Mi-Young;Cho, Hyung-Je
    • Annual Conference of KIPS
    • /
    • 2004.05a
    • /
    • pp.153-156
    • /
    • 2004
  • 이 연구에서는 동작 포착 데이터에서 최적의 동작을 얻기 위한 비용과 시간을 줄이고, 캐릭터의 체형 크기에 무관하게 복합 지형에서 적응적인 이동 동작을 빠르고 효율적으로 생성하는 방법을 제안한다. 즉 캐릭터의 신장이나 걷는 속도, 걸음폭 등의 매개변수들을 사용하여 평지면, 경사면, 계단면 그리고 굴곡면 등 다양한 지형에서의 달리기 동작을 생성하며 역운동학(Inverse Kinematics) 개념을 적용하여 관절들의 위치나 각도를 산출하고 관절의 이동 궤적을 계산하기 위해 큐빅 스플라인 곡선을 활용한다.

  • PDF