• Title/Summary/Keyword: 조직등가 물질

Search Result 64, Processing Time 0.025 seconds

Radiotherapic Valuation of Paraffin Wax for Patients with Oral Cancer (구강암 환자 치료시 치과용 기초상 왁스(Paraffin Wax)의 유용성 평가)

  • Na, Kyoung-Su;Seo, Seuk-Jin;Lee, Je-Hee;Yoo, Sook-Heun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • Purpose: This study is designed to investigate radiotherapic valuation of Paraffin Wax, which is newly formed for this study and generally utilized in dentistry, and Mouth Piece and Putty impression, which are commonly used in radiotherapy, for oral cavity as a compensator. Materials and Methods: Each compensator was formed by $10{\times}10{\times}1cm$ and measured radiation dose attenuation ratio with reference of water phantom which is made of tissue-equivalent materials. Two patients with oral cancer underwent DRR (Digitally Reconstructed Radiogrph) of Offline Review Program of Aria System and Portal vision for 5 times for each material to evaluate reproducibility by each filling materials. Moreover, MU (monitor unit) changes by dose absorption were considered in the case of inevitable implication of an filling materials in the range for radiotherapy. Results: Radiation dose attenuation ratios were shown -0.7~+3.7% for Mouth Piece, +0.21~+0.39% for Paraffin Wax and -2.71~-1.76% for Putty impression. Error ranges of reproducibility of positions were measured ${\pm}3mm$ for Mouth Piece, ${\pm}2mm$ for Paraffin Wax and ${\pm}2mm$ mm for Putty impression. Difference of prescription MU from dose absorption with an filling material increased +7.8% (250 MU) in Putty impression and -0.9% (230 MU) in Paraffin Wax as converted into a percentage from the standard phantom, Water 232 MU. Conclusion: Dose reduction of boundary between cavity and tissue was observed for Mouth Piece. Mouth Piece also had low reproducibility of positions as it had no reflection of anatomy of oral cavity even though it was a proper material to separate Maxilla and Mandible during therapy. On the other hand, Putty impression was a suitable material to correctly re-position oral cavity as before. However, it risked normal tissues getting unnecessary over irradiation and it caused radiation dose decrease by -2.5% for 1cm volume in comparison of it of water phantom. Dose reduction in Paraffin Wax, Fat Tissue-Equivalent Material, was smaller than other impressions and position reproducibility of it was remarkable as it was possible to make an anatomy reflected impression. It was also well fitted to oral cavity to transfer radiation dose planned in radiotherapy. Thus, Paraffin Wax will be an ideal material in radiotherapy for patients with oral cancer.

  • PDF

Interstitial Hyperthermia by Radiofrequency Needle Electrode System : Phantom and Canine Brain Studies (8 MHz 라디오파를 이용한 자입식 온열치료 -조직등가물질을 통한 온도분포 및 개 뇌실질의 조직병리 변화에 관한 연구-)

  • Lee, Hyung-Sik;Chu, Sung-Sil;Sung, Jin-Sil;Suh, Chang-Ok;Kim, Gwi-Eon;Loh-John-Juhn-Kyu;Kim, Young-Soo;Kim, Sun-Ho;Chung, Song-Sup;Han, Eun-Kyung;Kim, Tae-Seung
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.27-35
    • /
    • 1991
  • An interstitial radiofrequency needle electrode system was constructed for interstitial heating of brain tissue. Radiofrequency electrodes with Thermotron RF 8 were tested in an agar phantom and in a normal canine brain to determine how variations in physical factors affected temperature distributions. Temperature distributions were checked after heating with 1 mm diameter needle electrode implants on the corners of 1 and 2 cm squares in a phantom and plot isotherms for various electrodes arrangement. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures ($90\%$ relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature ($90\%$ relative SAR using Tm). We found that radiofrequency electrodes could be selected to match the length of the heating area without affecting its performance. The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50min to generate tissue temperatures of $43^{\circ}C$. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from $7\sim30$days. The acute stage (immediately after heating) was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter and by some polymer-phonuclear leukocytes infiltration. The appearance of lipid-laden macrophages surrounding the area of liquefaction necrosis was demonstrated in all three sacrificed dogs. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (Days 30) canine brain.

  • PDF

Growth of Li2B4O7 Single Crystal and Its Thermoluminescent Properties (Li2B4O7 단결정 성장과 열형광 특성)

  • Park, Kang-Soo;Ahn, Jung-Keun;Kim, Dong-Jin;Hwang, Yoon-Hwae;Kim, Hyung-Kook;Park, Myeong-Hwan;Kang, Hee-Dong;Kim, Do-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.16-23
    • /
    • 2003
  • Thermoluminescent properties of $Li_2B_4O_7$ single crystal grown by Czochralski method have been investigated. The high quality $Li_2B_4O_7$ single crystal without core was obtained at rotation speed of 10 rpm for seed crystal and pulling speed below $0.18\;mm{\cdot}h^{-1}$. The structure of $Li_2B_4O_7$ single crystal was classified as tetragonal by XRD analysis. The TL glow curve was composed with three overlapped peaks which can be easily deconvoluted and the TL response of $Li_2B_4O_7$ single crystal TLD to X-ray radiation is linear within the range of $50\;mGy{\sim}1.5\;Gy$. Activation energies of three TL glow peaks analyzed by the various heating rates method and PL spectrum were 0.93, 1.78 and 2.25 eV, respectively.

Monte Carlo Study of MOSFET Dosimeter Dose Correction Factors Considering Energy Spectrum of Radiation Field in a Steam Generator Channel Head (원전 증기발생기 수실 내 에너지 스펙트럼을 고려한 MOSFET 방사선검출기 선량보정인자 결정에 관한 몬테칼로 전산모사 연구)

  • Cho, Sung-Koo;Choi, Sang-Hyoun;Kim, Chan-Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • In Korea, a real-time effective dose measurement system is in development. The system uses 32 high-sensitivity MOSFET dosimeters to measure radiation doses at various organ locations in an anthropomorphic physical phantom. The MOSFET dosimeters are, however, mainly made of silicon and shows some degree of energy and angular dependence especially for low energy photons. This study determines the correction factors to correct for these dependences of the MOSFET dosimeters for accurate measurement of radiation doses at organ locations in the phantom. For this, first, the dose correction factors of MOSFET dosimeters were determined for the energy spectrum in the steam generator channel of the Kori Nuclear Power Plant Unit #1 by Monte Carlo simulations. Then, the results were compared with the dose correction factors from 0.652 MeV and 1.25 MeV mono-energetic photons. The difference of the dose correction factors were found very negligible $(\leq1.5%)$, which in general shows that the dose corrections factors determined from 0.662 MeV and 1.25 MeV can be in a steam general channel head of a nuclear power plant. The measured effective dose was generally found to decrease bit $\sim7%$ when we apply the dose correction factors.

A study on the Effectivness of Hand-made Paraffin Thyroid Phantom (Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구)

  • Park, Soung-Ock;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.237-243
    • /
    • 2007
  • Phantoms are very necessary for quality assurance of radio nuclides imaging systems to maintain standards and to ensure reproducibility of test. General quality assurance and instrument quality control are essential in every hospital. The human tissue equivalent materials are aluminum, areryl, water and epoxy..etc. It is very important to select optimum equivalant materials for a phantoms in QC. Especially, paraffin is very similar with human soft tissue in X or Gamma-ray physical characteristics and easy to buy with economically. We made a paraffin thyroid phantom and compare with thyroid areryl phantom, also used commercially in practice. Two small size cold spots(3 and 6 mm diameter) and a hot spot(3 mm diameter) embeded in paraffin phantom. And imaged with $^{99m}TcO_4$ by camera for analysis about spatial resolution and noise at the hot and cold spots. We got some results as below : 1. No difference in counting rate and noise between both arcryl and paraffin thyroid phantoms. 2. The best spatial resolution can be seen 6 cm distance between pinhole collimator and thyroid phantoms(arcryl and paraffin). 3. More optimal spatial resolution could acquired in paraffin thyroid phantom. Paraffin is very similar with human soft tissue in atomic number, density and relative absorbtion function, and can be shaped easily what we wanted. So we can recommendation paraffin as quality assurance phantom because its usefulness, economical benefit and purchasability.

  • PDF

Dose Evaluation of Three-Dimensional Small Animal Phantom with Film Dosimetry (필름계측을 이용한 3차원 소동물 팬텀의 선량평가)

  • Han, Su Chul;Park, Seungwoo
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.87-92
    • /
    • 2017
  • The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom.

The Changes in the Electrical Properties of $\textrm{BaTiO}_3$-based PTCR Materials due to the addition of (Ca, Sr)$\textrm{TiO}_3$ ($\textrm{TiO}_3$첨가에 의한 $\textrm{BaTiO}_3$계 PTCR 물질의 전기적 특성변화에 대한 연구)

  • Joo, Ji-Won;Kim, Jong-Hwan;Kim, Hwan;Park, Soon-Ja
    • Korean Journal of Materials Research
    • /
    • v.7 no.4
    • /
    • pp.347-353
    • /
    • 1997
  • BaTiO$_{3}$물질은 뛰어난 유전체로 널리 알려져 왔으며 특히 Heywang등이 제안한 PTCR특성은 이 물질의 응용범위를 세라믹 필터, 회로보호소자, 온도감지소자 및 저항가열장치 등으로 확대시켰다. 이러한 특성의 발현기구는 아직까지 밝혀지지 않은 상태이지만 제 특성을 향상시키기 위한 노력은 계속되어왔다. 특히 개발목적에 맞게 온도에 따른 정저항 특성(PTCR; Positive temperature constnat of resistivity phenomena)을 설계하려는 시도가 계속되어 왔으며 그 중에서도 페로브스카아트계의 2가와 4가의 양이온 자리를 등가나 원자가가 다른 양이온으로 치환하여 특성을 개선하려는 시도가 계속되어 왔다. 특히 $Ca^{2+}$나 Sr$^{2+}$$Ba^{2+}$자리를 치환할 수 있는 물질로 개별적인 첨가에 대한 연구는 많은 연구자들에 의해 진행된 상태이지만 최종적인 영향이나 해석에 대해서는 연구자들간에 이견이 많은 상태이다. 이번 실험에서는 BaTiO$_{3}$계에 합성한 (Ca, Sr)TiO$_{3}$를 Ca와 Sr의 상대적인 비를 변화시키면서 전체적인 첨가량을 변화시켜 그에 따른 전기적 특성 및 미세구조를 살펴보았다. (Ca, Sr)TiO$_{3}$의 첨가로 상온저항 및 PTCR특성을 변화시킬 수 있었으며 이를 통해 PTCR물질의 활용범위를 넓힐 수 있는 발판을 마련할 계기가 되었다. 특히 기존의 연구가 주로 개별적인 Ca나 Sr의 첨가에 의한 미세구조와 전기적 특성변화의 연구에 치중해 있었던 것과는 달리 Sr과 Ca을 함께 치환하여 상대적인 비가 특성에 더 중요한 영향을 끼치는 것을 확인하였으며 적절한 합성비를 선택하면 퀴리온도에서의 저항변화폭을 유지하면서 상온저항을 낮출 수 있음을 확인하였다.문했던 연구소인 Shanghai Research Center of Biotechnology, Shanghai Institute of Industrial Microbiology 및 Scientific Research Institute of Food and Fermentation Industry을 소개하고저 한다. 짧은 기간의 방문이라 주로 해당연구소의 자체소개 자료를 중심으로 방문하면서 느낀점을 기술하고저 한다.초염기성암 기원의 사문암이 열수변질작용을 받아 생성되었음을 명확하게 지시하며, 따라서 활석 광석내에 존재하는 녹니석은 활석의 근원 광물로서 녹니석편암 및 녹니석 편마암 매의 녹니석이 활석화되고 남은 잔존광물이 아니라, 주변암에 의해 성분상의 영향을 받은 열수와 사문암과의 변질교대작용에 의한 활석화과정 중에 주로 생성된 것으로 추정된다. 이러한 결과는 연구지역의 활석광상이 초염기성암의 사문암화 작용과 활석화 작용의 두 가지 변질작용에 의해 형성되어졌음을 알려준다.농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한 경우와 이차성 자연기흉에 대해서는 흉막유착술에 더 세심한 주의가 필요하다는 것을 확인하였다. 비디오흉강경수술은 통증이 적고, 입원기간이 짧고, 사회로의 복귀가 빠르며, 고위험군에 적용할 수 있고, 무엇보다도 미용상의 이점이 크다는 면에서 자연기흉에 대해 유용한 치료방법임에는 틀림이 없으나 개흉술에 비해 재발율이 높고 비용이 비싸다는 문제가 제기되고 있는 만큼 더 세심한 주의와 장기 추적관찰이 필요하리라 사료된다.

  • PDF

Inhomogeneity correction in on-line dosimetry using transmission dose (투과선량을 이용한 온라인 선량측정에서 불균질조직에 대한 선량 보정)

  • Wu, Hong-Gyun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.139-147
    • /
    • 1998
  • Purpose: Tissue inhomogeneity such as lung affects tumor dose as well as transmission dose in new concept of on-line dosimetry which estimates tumor dose from transmission dose using the new algorithm. This study was carried out to confirm accuracy of correction by tissue density in tumor dose estimation utilizing transmission dose. Methods: Cork phantom (CP, density $0.202\;gm/cm^3$) having similar density with lung parenchyme and polystyrene phantom (PP, density $1.040\;gm/cm^3$) having similar density with soft tissue were used. Dose measurement was carried out under condition simulating human chest. On simulating AP-PA irradiation, PPs with 3 cm thickness were placed above and below CP, which had thickness of 5, 10, and 20 cm. On simulating lateral irradiation, 6 cm thickness of PP was placed between two 10 cm thickness CPs additional 3 cm thick PP was placed to both lateral sides. 4, 6, and 10 MV x-ray were used. Field size was in the range of $3{\times}3$ cm through $20{\times}20$ cm, and phantom-chamber distance (PCD) was 10 to 50 cm. Above result was compared with another sets of data with equivalent thickness of PP which was corrected by density. Result: When transmission dose of PP was compared with equivalent thickness of CP which was corrected with density, the average error was 0.18 (${\pm}0.27$) % for 4 MV, 0.10 (${\pm}0.43$) % for 6 MV, and 0.33 (${\pm}0.30$) % for 10 MV with CP having thickness of 5 cm. When CP was 10 cm thick, the error was 0.23 (${\pm}0.73$) %, 0.05 (${\pm}0.57$) %, and 0.04 (${\pm}0.40$) %, while for 20 cm, error was 0.55 (${\pm}0.36$) %, 0.34 (${\pm}0.27$) %, and 0.34 (${\pm}0.18$) % for corresponding energy. With lateral irradiation model, difference was 1.15 (${\pm}1.86$) %, 0.90 (${\pm}1.43$) %, and 0.86 (${\pm}1.01$) % for corresponding energy. Relatively large difference was found in case of PCD having value of 10 cm. Omitting PCD with 10 cm, the difference was reduced to 0.47 (${\pm}$1.17) %, 0.42 (${\pm}$0.96) %, and 0.55 (${\pm}$0.77) % for corresponding energy. Conclusion When tissue inhomogeneity such as lung is in tract of x-ray beam, tumor dose could be calculated from transmission dose after correction utilizing tissue density.

  • PDF

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

Bolus Effect to Reduce Skin Dose of the Contralateral Breast During Breast Cancer Radiation Therapy (유방암 방사선치료 시 반대편 유방의 피부선량 감소를 위한 볼루스 효과)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.289-295
    • /
    • 2017
  • The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge $15^{\circ}$ were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.