• Title/Summary/Keyword: 조절 용이성 검사

Search Result 21, Processing Time 0.026 seconds

Analysis of Correlation of Visual Function Findings (시기능 검사값의 상관관계 분석)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.381-389
    • /
    • 2005
  • To Analysis of Correlation of Visual Function Findings, by assessing convergence and accommodation, 92 selected objects without any ocular diseases by apperatuses of visual chart(Shinnippon CT30) and phoropter(Shinnippon VT10) at a shan distance(40 cm) were tested upon MEM retinoscopy(Welch Allyn, USA), BELL retinoscopy(Welch Allyn, USA), binocular accommodative facility (${\pm}2.00$ D nipper, Bernell Co., USA), vergence facility(prism nipper, Bernell Co., USA). The results showed as follows. MEM retinoscopy(accommodative lag) showed the same result of a right eye and left eye. Bell retinoscopy(accommodative lag) showed higher correlations between right and left eye than MEM. The lower accommodative lag meant the higher accommodative facility. The binocular accommodative facility(polaroid) was higher than binocular accommodative facility(red-green). Correlations of accommodative facility between right and left eye were higher, and as the higher monocular accommodative facility also meant the higher binocular accommodative facility, monocular and binocular accommodative facilities were relative to vergence facility, These findings can be used as a clinical guide by curing patients' visual function.

  • PDF

The study on relation between ocular function and accommodative facility (시기능과 조절 용이성과의 관계 연구)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.375-380
    • /
    • 2005
  • To assess convergence and accommodation at a short distance, 92 selected subjects without any ocular diseases by apperatuses of visual chart(Shinnippon CT30) and phoropter(Shinnippon VT 10) at a short distance(40 cm) were tested upon MEM retinoscopy(Welch Allyn, USA). BELL retinoscopy(Welch Allyn, USA), binocular accommodative facility (${\pm}2.00$ D flipper. Bernell Co., USA), vergence facility(prism flipper, Bernell Co., USA). There were such test results as MEM retinoscopy(R/L)($+1.05{\pm}0.87/1.02{\pm}0.80$ D). BELL retinoscopy ($17.89{\pm}12.12/17.94{\pm}11.72cm$), binocular accommodative facility (R/G)($7.69{\pm}6.48cpm$). binocular accommodative facility(polaroid)($11.76{\pm}5.22cpm$), monocular accommodative facility(R/L) ($13.9{\pm}6.27/13.8{\pm}5.96cpm$), vergence facility($13.5{\pm}6.40cpm$).

  • PDF

Relationship Between Subjective Symptoms with Near Work and Binocular Function (근업시 자각 증상과 양안시 기능의 관계)

  • Shin, Jin-Ah;Lee, Ok-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.125-130
    • /
    • 2007
  • The aim of this work was to study the relationship between subjective symptoms and binocular function during near work in forty one(12-17yr) schoolchildren. CISS symptom survey, amplitude of accommodation, accommodative facility, neagative relative accommodation(NRA)/positive relative accommodation(PRA) near point of convergence(NPC), heterophoria, AC/A ratios were measured. The results of measurement were compared with normal expected value of each test and classified into normal and abnormal group. Accommodative insufficiency was more general than convergence insufficiency and esophoria was greater than exophoria. NRA/PRA showed very high and AC/A ratios were very low compare with normal expected value. The results of CISS was as follows; most frequent symptom was tired, mean score was $16.63{\pm}7.49$, mean number of symptoms were $10.07{\pm}3.04$, and mean number of serious symptoms were $1.98{\pm}2.13$. After classified into 4 groups according to score of symptoms, number of symptoms, and degree of symptoms and then analyze the correlation compare with binocular vision test results. NRA was most correlated with group comparison, accommodative facility was most correlated with score of symptoms, NRA was most correlated with number of symptoms, and near horizontal phorias were most correlated with serious symptoms. NRA showed most correlative relation with near symptoms.

  • PDF

An Experimental Study of Percutaneously Adjustable Pulmonary Artery Banding Device (가변성 폐동맥 혈류조절기의 실험적 연구)

  • Gang, Gyeong-Hun;Kim, Sang-Hyeon
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.580-584
    • /
    • 1997
  • To overcome the problems of classical pulmonary banding procedure, we developed a percutaneously adjustable pulmonary artery ba ding device. The banding device consists of banding portion of zig-zag shaped self-expandable stainless steel wire, shaft portion made by a polyvinyl catheter and a screw adjuster which includes a bolt and a nut. As the screw moves, the diameter of banding portion changes. Four Mongrel dogs ranging from 15 kg to 20 kg in weight underwent the banding of the mid portion of descending aorta with this devices through the left thoracotomy. One month after operation, we evaluated the pressure changes by controling the banding with the devices and then the dogs were sacrificed to study the microscopic changes in the aorta. The diameter and circumference of the band could be easily and finely adjustable by the screw control. The pressure recordings . revealed a linear increase and decrease in pressure gradient according to percutaneous ad;ustment of the banding device. Since the banding device can be easily placed and simply adjusted percutaneously, we hope the banding device may be applicab e clinically to improving the safety of pulmonary artery banding and debanding procedures in the future.

  • PDF

Relationships between Reading Ability and Binocular Vision (읽기능력과 양안시기능의 관계성)

  • Kim, Young Ji;Lee, Min-A;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.171-177
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the relationships between reading ability and binocular functions, based on self tests through surveys. The possibility of the reading ability tests used in this study as a tool on the determination about vision efficiency was also evaluated. Methods: Through reading ability tests about 138 university students, 72 students (52.2%) of them were first selected. Through self tests about dyslexia and light sensitivity, 38 students (52.7%) of the first selected students were secondly selected, whose extents are more than 3. Binocular tests were carried out about three groups (high, middle, low) of these secondly selected students. Tests about NPCs, distance and near phoria, amplitude of accommodation, fusional vergence, AC/A ratio, accommodative facility, and vergence facility were performed as binocular tests. Results: NPCs were closest to eyes at high groups. Fusional vergence, AC/A ratio, accommodative facility, and vergence facility of high group showed higher than other groups. The phoria at middle group showed higher than other groups. Conclusions: We found that reading ability and some of binocular functions were closely related. Therefore, vision training, associated with insufficiencies of binocular functions, is expected to improve reading ability.

Near Visual Performance of Multifocal Contact Lenses in University Students (대학생에서 멀티포컬 소프트콘택트렌즈의 근거리 시기능 유용성)

  • Jong, Woo-Cheol;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: This study was to investigate visual performance and subjective satisfaction with multifocal soft contact lenses at near works in university students. Methods: In a cross-over study design, 26 students (6 male, 20 female) who did not have any ocular disorder with at least 20/20(1.0) binocular vision were fitted with singlevision lenses (SofLens$^{TM}59$, Bausch + Lomb Co. USA) or multifocal lenses (SofLens Multifocal, Bausch + Lomb Co. USA). After 2 weeks, visual performance assessments included visual acuity, stereoacuity and contrast sensitivity function at distance and near. Near point of accommodation, accommodative facility, near point of convergence, vergence facility and near range of clear vision at near were examined. Students' satisfaction and preference were measured using survey questionaries. Results: Subjects maintained at least 20/20 binocular vision with multifocal and single-vision lenses at distance and near. There was no difference between multifocal and single-vision lenses in stereoacuity, contrast sensitivity function and vergence facility at far and near. The near point of accommodation, accommodative facility, near point of convergence and the near range of clear vision with multifocal lenses were better than single-vision lenses. On the survey questionaries, subjects reported that they preferred and satisfied with multifocal lenses with near works, and single-vision lenses with distance works. Conclusions: The majority of university students preferred multifocal to single vision lenses because multifocal lenses provided better visual performance at near works. This study suggests that multifocal lens is helpful for young adult in prolonged near works.

Study on Signal Processing in Eddy Current Testing for Defects in Spline Gear (스플라인 기어부 결함의 와전류검사 신호처리에 관한 연구)

  • Lee, Jae Ho;Park, Tae Sung;Park, Ik Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.195-201
    • /
    • 2016
  • Eddy current testing (ECT) is commonly applied for the inspection of automated production lines of metallic products, because it has a high inspection speed and a reasonable price. When ECT is applied for the inspection of a metallic object having an uneven target surface, such as the spline gear of a spline shaft, it is difficult to distinguish between the original signal obtained from the sensor and the signal generated by a defect because of the relatively large surface signals having similar frequency distributions. To facilitate the detection of defect signals from the spline gear, implementation of high-order filters is essential, so that the fault signals can be distinguished from the surrounding noise signals, and simultaneously, the pass-band of the filter can be adjusted according to the status of each production line and the object to be inspected. We will examine the infinite impulse filters (IIR filters) available for implementing an advanced filter for ECT, and attempt to detect the flaw signals through optimization of system design parameters for detecting the signals at the system level.

Changes in Accommodative Function of Young Adults in their Twenties following Smartphone Use (스마트폰 사용에 따른 20대 성인의 조절기능 변화)

  • Park, Mijung;Ahn, Young Joo;Kim, Soo Jung;You, Jiyoung;Park, Kyung Eun;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: The present study was conducted to investigate whether near work with smartphone could induce the change of accommodative function. Methods: Total 63 subjects(26 male and 37 female) in their 20s were firstly examined their visual functions related to accommodation and uncorrected spherical equivalent power as the control. After that, the subjects were asked to read a book for 30 min and sequentially watch a movie on smartphone for the same time after 30 min-break under the indoor light or as it was in the reverse order to avoid time-ordered effect. Their accommodative functions, 1) accommodative amplitude, 2) accommodative facility, 3) relative positive/negative accommodation, and 4) accommodative lag and their uncorrected spherical equivalent power were examined again following each task and compared with the control values. Results: The monocular accommodative amplitude was significantly decreased after smartphone watching compared with it after reading. The monocular and binocular accommodative facilities were tended to reduce after smartphone watching and book reading but were not significantly different. Neither significant change in positive relative accommodation was determined after smartphone watching nor book reading. Negative relative accommodation after smartphone watching was almost unchanged unlike reading a book. The accommodative lag after smartphone work was significantly higher than after book reading. Conclusions: The near work with a smartphone for 30 min induced the change of some accommodative functions, which was significantly greater than when reading under the same working environment.

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

DENTAL TREATMENTS OF THE CHILD WITH LOWE SYNDROME : A CASE REPORT (Lowe syndrome 환아의 치과적 치료 : 증례보고)

  • Ju, Chan-Hee;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.161-165
    • /
    • 2012
  • Lowe syndrome, also known as oculocerebrorenal syndrome, is a rare genetic disorder involving eyes, kidney, brain and musculoskeletal system, and occurs predominantly in males. The patient with Lowe syndrome is characterized with congenital cataracts, glaucoma, prominent forehead, thin and sparse hair, mental and growth retardation, muscular hypotonia, renal dysfunction, and metabolic bone disease. We have experienced a 10-year-old boy with Lowe syndrome who had poor oral hygiene and trouble for teeth brushing. To manage his behavior and systemic metabolic disorder, sedation was performed during dental care. Excessive calculus formation in this patient is caused by both medication and lack of ability to maintain oral hygiene. The dental management of those patients has to be focused on prevention due to difficulties in dental treatment and dangers of general anesthesia for the Lowe syndrome.