• Title/Summary/Keyword: 조영제 추적기법

Search Result 8, Processing Time 0.019 seconds

At the time of inspection CT cerebral blood flow in patients with acute ischemic stroke, a comparative study of Bolus Tracking Technique and Fixed Time Technique (급성기 허혈성 뇌졸중 환자의 뇌 관류 CT검사 시 고정시간기법과 조영제 추적기법의 비교 연구)

  • Kim, Ki-Jeong;Jeong, Hong-Ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.217-218
    • /
    • 2013
  • 급성기 허혈성 뇌졸중 증상이 있는 뇌 관류 CT검사를 시행한 환자를 대상으로 장비사가 제시한 고정 시간 기법(fixed time technique)과 조영제 추적 기법(bolus tracking technique)을 비교하여 환자의 피폭선량을 분석하고자 하였으며 조영제 추적 기법의 유용성과 최적의 조영증강 구간을 구현하는 Time graph를 알아보기 위한 것이다.

  • PDF

A Study on the Mitigation of the Exposure Dose Applying Bolus Tracking in Brain Perfusion CT Scan (뇌 관류 CT검사에서 BolusTracking기법을 적용한 피폭선량 저감화에 관한 연구)

  • Kim, Ki-Jeong;Jung, Hong-Ryang;Lim, Cheong-Hwan;Hong, Dong-Hee;Shim, Jae-Goo;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.353-358
    • /
    • 2014
  • This study was conducted to analyze the patient's exposed dose targeting the patients who had acute ischemic stroke symptoms and CT brain perfusion scan, by comparing fixed time technique and bolus tracking technique which was provided by the manufacturer and to identify the Time graph to implement the usability of contrast medium's tracking technique the best contrast enhancement intervals. $CTDI_{VOL}$ of PCT in patient appeared to be 431.72mGy in fixed scan delay protocol, whereas 323.61mGy in Bolus tracking technique. The value of DLP appeared to be $1243.47mGy{\cdot}cm$ in fixed scan delay protocol, whereas $932mGy{\cdot}cm$ in Bolus tracking technique. Time graph appeared to be various in fixed scan delay protocol, whereas the optimal time graph could be obtained in Bolus tracking. The exposure dose could be reduced by 25% applying Bolus tracking technique when taking brain perfusion CT scan.

Three-Dimensional Digital Subtraction Angiography (디지털 혈관 조영술 영상의 3차원적 해석)

  • 이승지;김희찬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.1
    • /
    • pp.63-71
    • /
    • 1983
  • A dye-edge tracking algorithm was used to determine the corresponding points in the two images(anterior-posterior and lateral) of the digital subtraction biplane angiography. This correspondence was used to reconstruct three dimensional images of cerebral artery in a dog experiment. The method was tested by comparing the measured image of oblique view with the computed reconstructed image. For the present study, we have developed three new algorithms. The first algorithm is to determine the corresponding dye-edge points using the fact the dye density at the moving edge avows the same changing pattern in the two projection views. This moving pattern of dye-edge density is computed using a matching method of cross-correlation for the two sequential frames' dye density. The second algorithm is for simplified perspective transformation, and the third one is to identify the specific corresponding points on the small vessels. The present method can be applied to compute the blood velocity using the dye-edge displacement and the three- dimensional distance data.

  • PDF

A Study on the Radiation Exposure Dose of Brain Perfusion CT Examination a Phantom (Phantom을 이용한 뇌 관류 CT검사에서 방사선 피폭선량에 관한 연구)

  • Jung, Hong-Rynag;Kim, Ki-Jeong;Mo, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.287-294
    • /
    • 2015
  • The purpose of this study, was Let's examine the exposure dose at the time of cerebral blood flow CT scan of acute ischemic stroke patients. In particular, long-term high doses of radiation sensitive organs and we Measured using phantom and a glass dosimeter. Apply the existing protocol suggested by the manufacturer (fixed time delay technique) and the proposed new convergence protocol (bolus tracking technique), reporting to measure the dose, dose reduction was to prepare the way. Results up to 39.8% as compared to the existing protocols in a new suggested convergence protocol, a minimum of 5.8% was long-term dose is reduced. Test dose of $CDTI_{vol}$ and DLP values decreased 25%, respectively, were measured at less than recommended dose. Try checking the protocol set out in the existing based on the analysis result of the above, by applying the proposed new convergence protocol by reducing the dose would have to contribute to improved public health. It is believed to be research continues to find the optimum protocol in the other tests.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

Study on Optimum Contrast Medium Quantity during Abdominal CT using Dual Energy Technique (복부 CT 검사 시 이중에너지 기법을 통한 적정한 조영제 양에 관한 연구)

  • Kang, Min;Choi, Namgil;Han, Jaebok;Kim, Wook;Jang, Yeongill;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2015
  • The purpose of this study is finding optimum contrast medium quantity during abdominal CT using dual energy technique. The study subjects are 30 patients who had received general single energy abdominal CT and received double energy technique follow-up abdominal CT. dual energy technique abdominal CT images were obtained after setting contrast medium quantities at 30%, 40%, 50%, 60% and 70% of contrast medium quantity at the time of single energy technique. Then the contrast enhancement (Hounsfield Unit; HU) was estimated by setting-up the regions of interest at aorta, inferior vena cava, hepatic portal vein and hepatic parenchymal. The obtained values were compared to the values of the same parts measured during single energy technique abdominal CT. The results of the study were as following. The 60% set up group had HU in aorta : $210.80{\pm}13.609$, IVC : $190.40{\pm}25.215$, hepatic portal vein : $198.40{\pm}21.232$ and hepatic parenchymal : $119.20{\pm}7.98$, The single energy abdomianl CT images had HU in aorta : $205.40{\pm}16.426$, IVC : $188.20{\pm}21.476$, hepatic portal vein : $195.40{\pm}22.744$ and hepatic parenchymal : $121.00{\pm}6.595$. Therefore, it is possible to obtain contrast enhancement by dual energy technique abdominal CT similar to the same by single energy technique abdominal CT by setting-up the quantity of contrast medium at 60% of contrast medium at the time of single energy technique abdominal CT. Based on the result of this study, it is possible to decrease existing quantity of contrast medium by _% and the injection velocity can be also decreased. Accordingly, it is believed that the result of study would be quite useful for patients who have renal function disorder, weak vein or side effect of contrast medium in the past.

Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique (X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

A Study on the Landscape Philosophy of Hageohwon Garden (별업 하거원(何去園) 원림에 투영된 조영사상 연구)

  • Shin, Sang-Sup;Kim, Hyun-Wuk;Kang, Hyun-Min
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.46-56
    • /
    • 2012
  • The research results of tracing the Landscape Philosophy of Hageowon garden(何去園) in Musu-dong, Daejon of Youhwadang, Kwon, Iijin(權以鎭, 1668-1734) is as below. The ideological background of the protagonist reflected in Hageowon is the Hyoje Ideology(filial piety and brotherly love, 孝弟) of Sinjongchuwon(painstakingly caring for one's ancestors), Musil ideology(pursuing ethical diligence and truthful mind, 務實) based on sadistic tradition and ethical rationalism, Confucionist Eunil Ideology(ideology on seclusion, 隱逸) of Cheonghanjiyeon(quiet relaxation, 淸閒之燕), and the Pungryu ideology(appreciation for the arts, 風流) of Taoism in the Taoist style. Thus, by substituting these ideological values into a space called Hageowon, the Byulup gardens(別業) such as the Symbolic garden(象徵園), meaning gaeden(意園), and miniascape garden(縮景園) were able to be constructed. 2) The space organization system of Hageowon is generally classified into three phases considering the hierarchy. The first territory is the transitional space having residential features, which is an area to reach peach tree - road(Taoist world 桃經) from Youhwadang(有懷堂). The second territory is a monumental memorial space where the Yocheondae(繞千臺), Jangwoodam(丈藕潭), Hwagae(花階), and the ancestral graves take place, centering on the yards of Sumanheon(收漫軒), and the third territory is the secluded space in the eastern outer garden where the mountain stream flows from the north to south and which is the vein of the left-hand blue dragon(靑龍) of the guardian mountain of Hageowon. 3) Symbolically, the first phase has symbolized the space as a meaningful scenery by overlapping the Confucionist place of Youhwadang - Gosudae(孤秀臺) - Odeokdae(五德臺), and the mystic world of Jukcheondang(竹遷堂) - peach tree - road(桃徑). The second phase, which is the space of Sumanheon(收漫軒), Yocheondae, and Jangwoodam, the symbolical value of Sinjongchuwon(愼終追遠) and the remembrance and longing for one's parents are reflected. The third phase, which is the eastern outer garden of Hageowon and where the mountain stream flows from the north to south, is composed of the east valley(東溪) - Hwalsudam(活水潭) - Sumi Waterfall(修眉瀑布). More specifically, (1) Mongjeong symbolizes the life of gaining knowledge through studying to realize one's foolishness, (2) Hwalsudam symbolizes a transcending attitude in life refusing to pursue wealth and fame, and (3) Jangwoodam symbolizes the gateway to the fairyland to enter the world of mystic gods. 4) The rationale behind Hageowon is that the two algorithms of Confucionism and Taoist Theory appear repeatedly and in an overlapping way. The Napoji(納汚池) and Hwalsudam, which pertains to the prelude of space development, has symbolized Susimyangseong(修心養成, meditating one's mind and improving one's nature), which is based on ethical rationalism. Moreover, if the Monjeong sphere pertaining to the eastern outer garden of Hageowon takes the Confucionist value system as its theme, including moral training, studying, and researching, Jangwudam, Sumi Waterfalls, and Unwa can be understood as a taste of Cheokbyeon(滌煩, eliminating troubles) for the arts where the mystic world is substituted as a meaningful scenery. 5) The miniascape technique called artificial mountain was substituted to Hageowon to construct a mystic world like the 12 peaks of Mt. Mu(巫山). By borrowing the symbolic meaning expressed in old poems, it has been named 'Habang(1/何放), Hwabong(2, 3/和峯), Chulgun(4, 5, 6/出群), Sinwan(7/神浣), Chwhigyu(8, 9, 10/聚糾), Cheomyo(11/處杳), Giyung(12/氣融).' The representative poet reciting artificial mountain were Wangeui(汪醫), Nosamgang(魯三江), Dubo(杜甫), Hanyou(韓愈), Jeonheaseong(錢希聖), and Beomseokho(范石湖). They related themselves with literature by transcending time and space and attempted to sing about the richness of the mental world by putting the mystic world and culture of appreciating the arts they pursued in the vacation home called Hageowon.