• Title/Summary/Keyword: 조영계획

Search Result 196, Processing Time 0.026 seconds

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

A Study on the Master Plan of the Temple Site of Baekje Period (백제 사찰 조영계획 고찰)

  • Tahk, Kyung-Baek
    • Journal of architectural history
    • /
    • v.20 no.4
    • /
    • pp.7-28
    • /
    • 2011
  • This study intends to investigate the measuring scales, locations and scales through arrangement plans for a research on construction plans. Through an analysis of the artifacts-measuring scales, the relation of two scales found, which further helped suppose the measuring scales applied during the foundation period. Southern dynasties-scale was still used even after the capital was transferred to Sabi till Tang-scale was introduced. Tang-scale was used for Buddhist temples mostly founded in the 7th century. On the other hand, Goguryo-scale seemed to be used almost at the same period as Southern dynasties-scale used, but it seemed that Goguryo-scale disappeared earlier than Southern dynasties-scale. The locations of Buddhist temples could be classified into mountains, flatlands and mountain valley. Buddhist temples founded in mountains were mostly small-sized, but ones located on flatlands could secure flat fields through mounding operations. In addition, through location conditions of Neungsa and Wangheungsa, it was possible to find out the district setting of Sabi Capital Castle. Finally, the expansion range of Buddhist temples were found to be towards the east and the west. As for the scales of temples according to such conditions of location, it was found a similarity in Temple sites. In general, it was possible to assume that the scales of Buddhist temples tended to be expanded along with spatial expansion and there were regular systems in Buddhist temples related to the Royal family. Through the analysis of arrangement plans between individual buildings, it was found that the basic arrangement of Gate-Pagoda-Main Hall-Lecture Hall was preserved, but the proportion of distances between individual buildings varied depending on cases. As a result, there were differences between scales of entire building sites, construction subjective influences and master plan for each location of a Buddhist temple.

3D MDCT Reformation Findings of the Radiographic Contrast Medium Extravasation (조영제 혈관외유출 현상의 3D MDCT 재구성 영상)

  • Kweon Dae-Cheol;Kim Jeong-Koo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.5
    • /
    • pp.145-152
    • /
    • 2006
  • Radiographic contrast medium may cause tissue injury by extravasation during intravenous automated injection during CT examination. A large - volume extravasation (140 mL) occurred in an adult during contrast-enhanced CT The patient had a swelling and injury on the dorsum right hand of intravenous catheter region. The extravasation injury site was determined by CT scanning. The extavasation compartment syndrome case was examined using four separate display techniques. These 3D MDCT findings might help to determine the best course of treatment for patient with contrast extravasation. 3D image reconstructions provide accurate views of high-resolution and soft-tissue imaging. This paper introduces extravasation with the radiography and 3D MDCT findings.

  • PDF

Characteristics of the Mission Planning for COMS Normal Operation (천리안위성 정규 운영에 대한 임무계획 특성)

  • Cho, Young-Min;Jo, Hye-Young
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.163-172
    • /
    • 2013
  • Communication Ocean Meteorological Satellite (COMS) has the hybrid mission of meteorological observation, ocean monitoring, and telecommunication service. The COMS is located at $128.2^{\circ}$ East longitude on the geostationary orbit and currently under normal operation service since April 2011. For the sake of the executions of the meteorological and the ocean mission as well as the satellite control and management, the satellite mission planning is daily performed. The satellite mission plans are sent to the satellite by the real-time operation and the satellite executes the missions as per the mission plans. In this paper the mission planning for COMS normal operation is discussed in terms of the ground station configuration and the characteristics of daily, weekly, monthly, and seasonal mission planning activities. The successful mission planning is also confirmed with the first one-year normal operation results.