• Title/Summary/Keyword: 조명계통

Search Result 460, Processing Time 0.023 seconds

Development of Black Shank Resistant Burley Tobacco Germplasm, KB 104 and KB 106, and Their Characteristics (버어리종 역병저항성 계통 KB 104와 KB 106의 육성경과 및 특성)

  • 조천준;김대송;정석훈;최상주;조명조
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.17 no.1
    • /
    • pp.57-61
    • /
    • 1995
  • Black shank(Phytophthora parasitira roar. nicotianae) resistant burley tobacco (Nicotiana tabacum L.) germplasms, KB 104 and KB 106, were developed by Korea Ginseng & Tobacco Research Institute. KB 104 was developed from the single cross of Burley 21$\times$Newton 77, using a modified pedigree method. KB 104 was highly resistant to black shank, and its agronomic characteristics and chemical contents were comparable to those of Burley 21, and value per 10a was slightly higher than Burley 21, KB 106 is a maternally derived doubled haploid made by N. africana method from the single cross of Burley 21$\times$ Va 509. KB 106 was also highly resistant to black shank, had two more harvestable leaves per plant and flowered three days later than Burley 21 did. Total alkaloid and nicotine contents of KB 106 were significantly lower than those of Burley 21. But its nornicotine content was higher than Burley 21 5. Key wads : Burley tobacco germplasm, Black shank resistance.

  • PDF

Assessment of Substantial Equivalence and Environmental Risk for Event Selection of Genetically Modified Chrysanthemum (국화의 GM 이벤트 선발을 위한 실질적 동등성 및 환경위해성 평가)

  • Lim, Jin Hee;Shim, Myung Syun;Oh, Kwan Hun;Seo, Ji Yeon;Lee, Su Young;Park, Sang Kun;Shin, Hak Ki;Cho, Myoung Rae
    • Horticultural Science & Technology
    • /
    • v.32 no.4
    • /
    • pp.517-524
    • /
    • 2014
  • As an assessment of substantial equivalence and environmental risks of branchless chrysanthemum GM lines (LeLS69, LeLS76, LeLS80) developed in Korea, we investigated their degree of branchlessness and developmental characteristics including growth and flowering, as well as the stability of populations of insect pests and soil microbes. The GM lines were compared with a control variety, 'Jinba'. LeLS80 showed the highest level of branchlessness among the three GM lines, whereas abnormal axillary buds developed in lines LeLS76 and LeLS69. There were no significant differences between the growth characteristics of 'Jinba' and the GM lines. The branchlessness LeLS80 was increased during the summer season, suggesting that it is a useful germplasm for developing elite branchless cultivars. These GM lines showed no significant differences in the occurrence of five insect pests including aphids, mites, leaf miners, thrips, and whiteflies. Similarly, for soil microbes including bacteria and actinomycetes, there were no significant differences between 'Jinba' and the GM lines. However, there was a higher occurrence of fungi in the GM lines compared to 'Jinba'. Our findings suggest that 'Jinba' and the GM lines are substantially equivalent, although further monitoring studies are needed to confirm this.

Breeding of a Mid-Late Maturing Watermelon Cultivar, 'Hanbit' with Resistant to Anthracnose Race 3 (수박 탄저병 Race 3 저항성 중만생종 수박 '한빛' 육성)

  • Huh, Yun-Chan;Hong, Kue-Hyon;Ko, Ho-Cheol;Park, Kyoung-Sub;Park, Dong-Kum;Lee, Joong-Sup;Cho, Myeoung-Cheoul;Lee, Sok-Young;Ko, Kwan-Dal;Lee, Woo-Moon
    • Korean Journal of Breeding Science
    • /
    • v.42 no.6
    • /
    • pp.699-702
    • /
    • 2010
  • Anthracnose is a major limiting factor of the watermelon production in Korea. A mid-late maturing watermelon line, 'Hanbit' with resistance to anthracnose (Colletotrichum orbiculare) race 1 and 3, was developed by the cross between anthracnose resistant cultivar 'AU-Producer' and high quality inbred line '920533' at the National Institute of Horticultural and Herbal Science, Rural Development Administration (RDA). 'Hanbit' produces 5.4 to 9.5 kg of red flesh fruits with clear stripes on skin. Average soluble solid contents are ranged from 10.4 to 11.2$^{\circ}$Bx. The yield and quality of 'Hanbit' was comparable to or better than those harvested from the popular commercial cultivars. 'Hanbit' can be cultivated in open fields and under the protected green house condition. In addition to the commercial production, it can be used as a resistant material in $F_1$ hybrid breeding program.

A Fuel Cell Generation Modeling and Interconnected Signal Analysis using PSCAD/EMTDC (연료전지 발전시스템의 PSCAD/EMTDC 모델링 및 계통연계에 따른 전력신호 분석에 관한 연구)

  • Choi, Sang-Yule;Park, Jee-Woong;Lee, Jong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.21-30
    • /
    • 2008
  • The fuel cell generation convert fuel source, and gas directly to electricity in an electro-chemical process. Unlike traditional and conventional turbine engines, the process of fuel cell generation do not burn the fuel and run pistons or shafts, and it has not revolutionary machine, so have fewer efficiency losses, low emissions and no noisy moving parts. A high power density allows fuel cells to be relatively compact source of electric power, beneficial in application with space constraints. In this system, the fuel cell itself is nearly small-sized by other components of the system such as the fuel reformer and power inverter. So, the fuel cell energy's stationary fuel cells produce reliable electrical power for commercial and industrial companies as well as utilities. In this paper, a fuel cell system has been modeled using PSCAD/EMTDC to analyze its electric signals and characteristics. Also the power quality of the fuel cell system has been evaluated and the problems which can be occurred during its operation have been studied by modeling it more detailed. Particularly, we have placed great importance on its power quality and signal characteristics when it is connected with a power grid.

Design and Assessment of DC Traction Power Supply System for Light Rail Transit (직류 전기철도 시스템의 변전소 설계 및 평가)

  • Baek, Byung-San;Moon, Jong-Fil;Choi, Joon-Ho;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.86-97
    • /
    • 2006
  • For the design of DC traction power supply system at new Light Rail Transit(LRT) construction, it is very important to determine system configuration, location and power capacity of substation. However, a LRT system consists of a number of subsystems such as train movement, power supply and traction drives, which inevitably contains many complexities and diversities. The objective of this paper is to clarify and systematize the design procedure and its assessment for the electrification system of a LRT line. This paper discusses in detail our approach to system design and its assessment. The whole DC-feeding network configuration, characteristics of a train, and design method of substation arrangements is thoroughly investigated for the design. As a result of the investigations, the design procedure is clarified and systematized and a computer program for the design and evaluation of the system is developed using the most suitable iterative method with nodal equation. To verify the proposed design and its assessment procedure, case studies for the DC traction power supply system of a planed Korean LRT line are performed.

The Research for the Change of Load Demand in Wintertime by the Influence of a Climate (기후의 영향에 따른 동절기 전력수요 변화에 대한 연구)

  • Ahn, Dae-Hoon;Song, Kwang-Heon;Choi, Eun-Jae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.47-54
    • /
    • 2009
  • These clays, because of world economy recession, exports decreased rapidly and manufacturing industry growth fell into negative. Industrial power consumption has been reduced about 7[%] that forms 53[%] of total load demand in Korea. And also, daily load pattern has been changed in several ways because of power consumption decrease influenced by domestic demand recession and heating power load decreased by the rise in temperature. This research analyzes, by analyzing maximum load demand, average load demand, load pattern based on relative factor, and load sensitiveness in accordance with temperature, that maximum load demand is more sensitive to atmospheric temperature than GDP growth rate and average load demand tends to be reduced according to GDP growth rate. I suppose KPX could operate the network system economically and safely by forecasting load demand in winter and summer seasons based on the results.

Power Factor Correction of Single-phase PWM Converter using Third Harmonic Injection (3차 고조파 주입에 의한 단상 PWM컨버터의 고역률 제어)

  • 손진근;유성식;김병진;박종찬;전희종
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.25-33
    • /
    • 1999
  • In this paper, the method of reducing hanmnics and correcting of power factor in single PWM converter associated with diode rectifier and boost converter is studied. In the general diode rectifier there are sorre problems that discontinuous current of reducing power factor and including distortion of hanmnics at the input current affects other sources. To solve the problems of performance degradation due to pulse wavefonn in the input current, the ac-dc converter in which the hanmnic distortion in the input current is reduced using a third-hanmnic-injected PWM is proposed. A lower power loss of switching and easy configuration of circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total hanmnic distortion was established.lished.

  • PDF

Diagnosis of Insulation Deterioration in Cast-Resin Power Transformer using Acoustic Emission Techniques (음향방출법에 의한 몰드형 전력변압기의 절연열화 진단)

  • 이상우;김인식;이동인;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, AE(Acoustic Emission) signals detected from the growth of the electrical tree in an epoxy resin under ac high-voltage application were analysed to diagnose the insulation deterioration of cast-resin power transformer. Frequency spectra of AE signals generated from the magnetizing and the load currents in the actual operating cast-resin power transformer of 500[kVA] under distribution system of 22.9[kV] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in the core of the transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals. The frequency spectra of AE signals generated from the cast-resin power transformer in operation due to both the magnetizing and the load currents appeared in the range of 40-120[kHz], but the frequency band of AE signals emitted from the void discharges in an epoxy resin sample was about 50[kHz] to 230[kHz].

  • PDF

Electromagnetic Force Calculation of Internet Winding Fault in A Distribution Power Transformer by using A Numerical Program (수치해석을 이용한 배전용 변압기 권선 고장시의 전자력 계산방법 연구)

  • Shin, Pan-Seok;Ha, Jung-Woo;Chung, Hee-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.60-67
    • /
    • 2007
  • In this paper, a simulation method of the internal winding fault is proposed to calculate winding current and electromagnetic force in a distribution power transformer by suing FEM program. The model of the transformer is a single phase, 60[Hz], 1[MVA], 22.9[kV]/220[V], cable-type winding. The short-circuit current and electromagnetic force are calculated by FEM(Finite Element Method) program(Flux2D) and the results we verified with theoretical formula and PSPICE program. The simulation results are fairly good agreement with the other verified methods within 5[%] error rate. The turn-to-turn short-circuit current is 500 times of the rated current and the electromagnetic force is about $20{\sim}200times$. The method presented in this study may serve as one of the useful tools in the electromagnetic force analysis of the transformer winding behavior under the short circuit condition for design of the structure.

A Study on Over Current Protection Method of Unified Power Quality Conditioners (통합 전력품질 제어기의 과전류 보호방법에 관한 연구)

  • 이우철;김한정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.22-28
    • /
    • 2002
  • A protection scheme for Unified Power Quality Conditioner (UPQC) is presented and analyzed in this paper. The proposed UPQC has the series active power filter operated as a high impedance k($\Omega$) to the fundamentals when the over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory,[1] the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the UPQC without additional protection circuits. The validity of proposed protection scheme is investigated through simulation results.