• Title/Summary/Keyword: 조기 압축강도

Search Result 98, Processing Time 0.027 seconds

Experimental Study on the Fire Resistance of Concrete Filled Steel Tubes according to Concrete Compressive Strengths (콘크리트 압축강도에 따른 강관기둥부재의 내화성능에 관한 실험적 연구)

  • Kwon, In-Kyu
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • Concrete filled steel tubes(CFST) is considered as a column having better structural stability and better performance of fire resistance than that made with H-section and hollow section in itself. To get the fire resistance of the CFST, two kinds of concrete strength were used, 21 MPa, 40 MPa and 4 sorts of the applied loads were calculated and used to the specimens such as 3.5 m long, round and rectangular section. After various fire tests under 4 sorts of load ratios, the fire resistance of the CFST is not possible to get over 1 hour because of the rapid decrease of concrete strength. The below 50% of the applied load is recommended to obtain over 1 hour fire resistance of the CFST.

Characterization of Foamed Concrete Using Calcium sulfaluminate (칼슘설포알루미네이트를 활용한 기포콘크리트의 특성평가)

  • Cho, Yong-Kwang;Kim, Chun-Sik;Nam, Seong-Young;Cho, Sung-Hyun;Lee, Hyoung-Woo;Ahn, Ji-Whan
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.10-16
    • /
    • 2019
  • The purposes of this study is to secure subsidence stability and economical efficiency of lightweight foamed concrete. The composition of lightweight foamed concrete was designed for OPC by substituting with constant contents of calcium sulfaluminate and fly ash. It is found that the flow of lightweight foamed concrete decreased with early ettringite formation by CSA. The initial strength increased with the decrease of drying time of lightweight foamed concrete when CSA was substitution to 10%. The settlement deep of foamed concrete improved the settlement stability by replacing CSA, which prevented shortening of the coagulation time and bubble puffing.

Development of penetration rate model and optimum operational conditions of shield TBM for electricity transmission tunnels (터널식 전력구를 위한 순굴진율 모델 개발 및 이를 활용한 쉴드TBM 최적운전 조건 제안)

  • Kim, Jeong-Ju;Ryu, Hui-Hwan;Kim, Gyeong-Yeol;Hong, Seong-Yeon;Jeong, Ju-Hwan;Bae, Du-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.6
    • /
    • pp.623-641
    • /
    • 2020
  • About 5 km length of tunnels were constructed by mechanized tunnelling method using closed type shield TBM. In order to avoid construction delay problems for ensuring timely electricity transmission, it is necessary to increase the prediction accuracy of the excavation process involving machines according to rock mass types. This is important to corroborate the project duration and optimum operation for various considerations involved in the machine. So, full-scale tunnelling tests were performed for developing the advance rate model to be appropriately used for 3.6 m diameter shield TBM. About 100 test cases were established and performed using various operational parameters such as thrust force and rotational speed of cuttterhead in representative uniaxial compressive strengths. Accordingly, relationships between normal force and penetration depth and, between UCS and torque were suggested which consider UCS and thrust force conditions according to weathered, soft, hard rocks. Capacity analysis of cutterhead was performed and optimum operational conditions were also suggested based on the developed model. Based on this study, it can be expected that the project construction duration can be reduced and users can benefit from the provision of earlier service.

Characterization of Freezing-Thawing on the Artificial Weathering of $TiO_2$ Loaded Granite and Their Physical Property ($TiO_2$가 담지된 화강암의 인공풍화에 미치는 수분의 동결-융해의 평가와 물리적 성질)

  • Shon, Byung-Hyun;Jung, Jong-Hyeon;Kim, Hyun-Gyu;Choung, Young-Hean;Cho, Ki-Chul;Oh, Kwang-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.183-190
    • /
    • 2006
  • An experimental study was conducted to evaluate the effect of freezing-thawing and air pollutants on the weathering of $TiO_2$ loaded granite. And the granite was coated with $TiO_2$ catalyst and tested. After freezing-thawing and air pollutants experiments the mineral compositions of the granite surface were lower then that of the fresh granite. Density of the weathered granite was steadily decreased from $2.60g/cm^3\;to\;2.55{\sim}2.56g/cm^3$, but absorption ratio and porosity were slightly increased. From these results, it was expected that granite could be weathered by freezing-thawing md air pollutants. In the case of $TiO_2$ was coated to the granite, the compressive strength and absorption ratio were slightly enhanced compared to the $TiO_2$ non-coated granite. Therefore, the $TiO_2$ coating method tested in this study considered to be a viable method to assist in the conservation of granite from environmental contaminants.

Controlled Low Strength Material for Emergency Restoration Using Bottom Ash and Gypsum (저회와 석고를 활용한 지반함몰 긴급복구용 고유동성 채움재 연구)

  • Lee, So-Yeon;Yoon, Hwan-Hee;Son, Min;Kong, Jin-Young;Jung, Hyuk-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.2
    • /
    • pp.19-31
    • /
    • 2018
  • Recently the ground subsidence which seriously weakens the safety of cities tends to increase. The purpose of this paper is to develop the materials by using industrial by-products for the application to emergency restoration process in case of ground subsidence. In this paper the laboratory tests including pH test, initial setting test, unconfined compressive strength test, and flow test were performed in order to evaluate the design properties of Controlled Low Strength Material (CLSM). The field test was carried out for evaluating the performance for the early strength of CLSM and the workability for emergency restoration. Test results showed that the strength will be too high to re-excavate the ground when the cement ratio is more than 4%. The optimum mixing ratio appears to be most effective when the mixing ratio of the bottom ash and the gypsum is approximately 50:50 and the cement content is 2%.

Research on the Surface Improvement of High Soft Ground Using Calibration Chamber Test (모형토조실험에 의한 초연약지반의 표층개량에 관한 연구)

  • Bang, Seongtaek;Yeon, Yongheum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.5
    • /
    • pp.39-46
    • /
    • 2019
  • Most of the soil used for reclamation is marine clay generated from dredging construction.The soft ground made of dredged clay has high water content and high compressibility, so the bearing capacity of the ground is very weak and it is difficult to enter the ground improvement equipment. Therefore, surface hardening treatment method is used to enter equipment prior to full-scale civil engineering work, and stabilizer is mainly used for cement series. Cement-based stabilizers have the advantage of improving the ground in a short period of time and have excellent economic efficiency, but they are disadvantageous in that they cause environmental problems due to leaching of heavy metals such as hexavalent chromium. In this study, environmental effects evaluation of dredged clay mixed with normal portland cement and environmentally friendly stabilizer was evaluated, and uniaxial compressive strength test and indoor model test were conducted to confirm the bearing capacity characteristics of the solidified layer.

A Experimental Study on the Strength Improvement of Ground Granulated Blast Furnace Slag Concrete Using Recycled Aggregate Powder as Alkali-activator (순환골재 미분말을 알칼리 자극제로 활용한 고로슬래그 미분말 혼입 콘크리트의 강도증진에 관한 실험적 연구)

  • Jeon, Chan-Soo;Ryu, Dong-Wo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.6
    • /
    • pp.527-534
    • /
    • 2017
  • Accordingly, this study, in order to use powder of recycled aggregate from production of recycled aggregate as an activator of ground granulated blast furnace slag, the influence of added recycled aggregate powder on physical properties of concrete induced ground granulated blast furnace slag were analyzed by hydration stages. The results of the study are summarized as follows: Except for samples eluted powder of recycled aggregate 1%, all the samples were high alkali suspensions with higher than pH 12.0. In particular, when eluted time was 5 hours, the sample eluted powder of recycled aggregate 3% showed about 15 mg/l of calcium hydroxide that was not different from the amount of calcium hydroxide in the mixing water eluted powder of recycled aggregate 5%. Hence, from this results, it can be considered that optimal eluted powder of recycled aggregate was 3% in this study. When using mixing water eluted with powder of recycled aggregate, compared to use of ordinary mixing water, it showed greater compressive strength in the entire ages, and in the sample replaced with ground granulated blast furnace slag by 50%, its compressive strength was greater than that of the OPC. As use of mixing water eluted with powder of recycled aggregate in concrete used with large amount of ground granulated blast furnace slag was more effective for improving compressive strength than ordinary mixing water, it is verified that powder of recycled aggregate had an effect of activator.

A Study on the Properties of Recycled Concrete Using Recycled Fine Aggregates with different Removal formulas of Powder In Aggregate (미분 제거방식이 다른 2종의 재생 잔골재가 콘크리트외 특성에 미치는 영향)

  • Lee Mun-Hwan;Lee Sea-Hyun;Shim Jong-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.95-104
    • /
    • 2005
  • The research conducted to study the potential practicability of recycled aggregate concrete by analyzing the characteristics of concretes made of recycled quality aggregates produced by wet and dry process has found the following results. The air content of recycled aggregate concrete increased with increase of the substitut on rate due to mortar included while producing recycled aggregates. However, the concretes with aggregate produced by dry process had relatively low rate of increase in air content. The slump showed generally decreasing trend as the substitution rate of recycled aggregate increased regardless of the wet or dry process. It was assumed that the mortar particles remained in recycled aggregate absorbed the surplus hydration in concrete and decreased fluidity The compressive strength generally decreased as the substitution rate of recycled aggregate increased, however there was an increasing trend as well due to decreasing effect of water-cement ratio when the substitution rate of recycled aggregate reached 25, 50% after mix. This phenomena also appeared in early age, which meant that recycled aggregate concrete should not be retarded in setting when applied in the field. The tensile strength also reached the maximum when wet or dry recycled aggregate replaced with 25%. To conclude, recycled aggregates for concrete produced by wet or dry process are expected to demonstrate essential characteristics of concrete without significant decline in physical or dynamic quality when the substitution rate is below 25% although there are variations subject to water-cement ratio. However, slight differences are expected due to types of recycled aggregate and physical quality.

A Study on the Development of Non-PC High-Early-Strength Concrete Without Steam Curing (증기양생이 불필요한 PC부재용 조강형 콘크리트 개발에 관한 연구)

  • Jun, Woo-Chul;Lee, Ji-Hwan;Park, Hee-Gon;Lee, Jae-Sam;Kim, Kyung-Min;Cho, In-Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.156-162
    • /
    • 2014
  • This study aims to develop a rapidly hardening type of concrete to achieve the removal of form intensity (more than 10MPa) using the method of curing at room temperature in order to solve some economic environmental problems by omitting the steam curing process involved in producing PC (Precast Concrete). Therefore, this study evaluated a rapidly hardening cement containing a high amunt of C3S, which is very responsive in expressing early intensity, and a rapidly hardening type of concrete which uses some hardening accelerator to increase thehydration reaction of $C_3S$. The results of the experiment on concrete using some hardening accelerator are asfollows. In the slump flow experiment for identifying the liquidity and the air test, the desired values were met. The compression strength showed rapid expression response by 12 hours, and met the desired value within 6~9 hours. Its drying shrinkage value and Autogenous shrinkage value were measured as below ($-754.5{\times}10^{-6}$),and satisfied the requirements. In addition, in the Semi-Adiabatic Temperature Test, it was found that the concrete rose to its peak temperature within 24 hours and then its temperature dropped.

A Study on Seepage Cutoff Effect of the Environmentally Friendly SCM (SCM 친환경주입공법에 의한 차수 효과에 관한 연구)

  • Chun, Byung-Sik;Roh, Jong-Ryun;Jooi, Tae-Seong;Do, Jong-Nam
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.4
    • /
    • pp.65-71
    • /
    • 2005
  • Recently, difficulties in soft ground improvement that caused by effectiveness of the ground improvement, the durability and environmentally friendliness of the injection material come to the fore. This paper studies the field applicability of the SCM in reinforcement and seepage cutoff of the back of an existing continuous wall. SCM uses double rod which imposes heavy pressure($10-100kgf/cm^2$) to disturbed, cut, discharge, and mix the ground. It is observed that a bulb is formed by using cement paste and environmentally friendly injection materials with minimal alkali leaching. Unconfined compression test and fish poison tests are performed. Test results indicate that the method results in higher durability, less leaching through use of the environmentally friendly injection material, and faster mobilization of the strength. In addition, field tests confirm the formation of the bulb and the seepage cutoff wall.

  • PDF