• Title/Summary/Keyword: 젤

Search Result 525, Processing Time 0.035 seconds

Effect of Glycolysis Rate in Porcine Muscle Postmortem on Gel Property of Pork Surimi (돼지 근육의 사후 해당속도가 돈육 수리미의 젤 특성에 미치는 영향)

  • Kang Guen-Ho;Yang Han-Sul;Jeong Jin-Yeon;Joo Seon-Tea;Park Gu-Boo
    • Food Science of Animal Resources
    • /
    • v.25 no.4
    • /
    • pp.423-429
    • /
    • 2005
  • Properties of pant surimi derived from porcine longissimus muscle were investigated Rapid glycolysis of muscle reduced yield $\%$ of water-washed pork and moisture $\%$ of pent surimi because of ie lower ultimate pH. Gel Hardness was significantly (p<0.05) higher in pork surimi from rapid glycolysis muscle, but springiness was higher (p<0.05) in pork surimi from normal glycolysis muscle. SDS-PAGE pattern showed denaturation of sarcoplasmic proteins onto myofibrillar proteins in rapid glycolysis muscle, resulted in dark color and hard texture of pork surimi. Color and texture of gels were related with water-holding capacity of muscle proteins and moisture $\%$ in gel matrix. Results imply that glycolysis rate of porcine muscle at postmortem could affect gel properties of pork surimi, and muscle with rapid glycolysis muscle could produce a hard texture of pork surimi and dark color.

Characterization of electrochemical behaviour for supercapacitor based on porous activated carbon composite with various contents of metal-organic framework(MOF) (금속유기골격체(Metal-organic Framework)의 함량에 따른 다공성 활성탄소 복합재료 기반 슈퍼커패시터의 전기화학적 거동 분석)

  • Jeong, Hyeon Taek;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1200-1207
    • /
    • 2020
  • We have fabricated the supercapacitor composed of porous activated carbon, metal-organic framework (MOF) with polymer based solid state electrolyte as a "ion gel" and characterized its electrochemical behaviour as a function of the MOF contents. The electrochemical properties of the supercapacitor were analyzed via cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS) and galvanostatic charge/discharge test. As a results, the supercapacitor based on porous activated carbon/MOF composite showed the highest capacitance value at 0.5 wt% of MOF contents and decreased capacitance with increase MOF contents over the 0.5 wt%. Consequently, the porous activated carbon/MOF composite based supercapacitor is applicable to various aspect for energy storage device.

Plasma Catalytic Methane Conversion over Sol-gel Derived Pt/TiO2 Catalyst in a Dielectric-barrier Discharge Reactor (DBD 반응기에서 솔-젤 법으로 제조된 Pt/TiO2 촉매를 이용한 메탄의 플라즈마 전환반응)

  • Kim, Seung-Soo
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.455-459
    • /
    • 2007
  • Plasma catalytic methane conversion was carried out in the presence of sol-gel derived $Pt/TiO_2$ catalysts within a dielectric-barrier discharge (DBD) reactor. Plasma-assisted reduction (PAR) was applied to reduce the prepared $Pt/TiO_2$ catalysts in DBD reactor, and prepared catalysts were successively reduced by PAR within 20 min irrespective of the Pt loading and the calcination temperature. The highest methane conversion was 40% when 3 wt% $Pt/TiO_2$ and 5 wt% $Pt/TiO_2$ catalysts were used after calcination at $600^{\circ}C$. The selectivities of light alkanes ($C_2H_6$, $C_3H_8$, $C_4H_{10}$) were highly increased when $Pt/TiO_2$ catalysts were used in DBD reactor.

Analysis of Attenuation Differences According to Radiolucent and Radiopague Materials : Based on DECT (Dual Energy Computed Tomography) (방사선 투과 및 불투과성 물질에 따른 감약 차이의 분석 : DECT 검사 중심으로)

  • Jang, Hyon-Chol;Kim, Yoon-Shin;Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1584-1589
    • /
    • 2014
  • This study analyzed CT values of radiolucent and radiopaque materials by energy region after selecting radiolucent and radiopaque materials at random using GE's DECT((Dual Energy Com-puted Tomography) at S University Hospital located in Gyeonggi-province from July through August in 2013. Besides, it drew out the most analogous energy region to the value of 120kVp CT, which is applied to existing SECT(Single Energy Computed Tomography), by utilizing the analysis method of CT values and tried to find out the most useful and appropriate materials when contrast was applied within visible area in clinical application. As a result, there was little decrease of CT value after 90KeV in the case of materials with low density and high moisture content such as normal saline, methyl-cellulose and gels used in ultra-sonic waves test; energy does not influence much on materials with extremely low or high density such as air and contrast medium; methyl-cellulose and gels used in ultra-sonic waves test are considered to be the most useful materials for clinical applications.

Development of a Portable Digital Electrocardiograph(ECG) measurable with Gel-less Metal Electrodes (젤리스 금속 전극으로 측정가능한 휴대용 디지털 심전도계의 개발)

  • Nam, Young-Jin;Park, Kwang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1903-1907
    • /
    • 2013
  • Heart condition should be observed for long periods of time because it does not appear abnormal all the time. However, there are many difficulties checking our health for a long time due to its size, operation of equipment, and cost. To solve these problems, an electrocardiograms(ECG), specially interfacing three gel-less metal electrodes for low cost portable applications, is designed and implemented. Gel-less metal electrodes are used for ECG monitoring system instead of gel-type electrodes that can cause skin rashes and itching problem. The whole ECG system consists of two parts-analog and digital circuits. The analog measurement circuit that has a 18*25mm size is made up of op-amps maintaining a sufficiently high common-mode noise rejection and passive elements of SMD type. Analog heart signal is converted to digital stream suitable for display on a TFT-LCD by an 8-bit microcontroller. The size of the completed ECG system is 25*80*50mm and its weighing is about 150g, which is small enough to be easily used. Therefore, the implemented ECG system can be used as a portable one.

Quality Comparison of Gelatins Manufactured from Raw and Scalded Pigskins (생박 및 탕박 돈피에서 생산된 젤라틴 품질비교)

  • Lee, Moo-Ha;Kim, Yang-Ha;Chung, Myung-Sub
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.102-106
    • /
    • 1987
  • In order to examine the appropriateness of types of pigskin as a raw material for gelatin production, comparison was made on the quality of gelatins made from raw and scalded pigskins. Raw and scalded pigskins were acidified in 1.7% HCl solution for 15-18 hr and then washed by tap water for 10 hr. After washing, pigskins were extracted at $60^{\circ}C$, $70^{\circ}C$ and $80^{\circ}C$ to produce gelatins. Gelatins from raw pigskins appeared to be better in gel strength than those from scalded ones at all extraction temperatures. Gelatin yield was higher with raw than with scalded pigskins. With the increase of extraction temperature, the decrease in gel strength and viscosity was resulted in. More colored gelatins were produced with increasing extraction temperature in both raw materials. Electrophoretic pattern of gelatins showed that higher molecular weight fractions decreased with the increase of extraction temperature and pigskin gelatin had more complicated molecular composition than that of type B gelatin (alkali-treated gelatin).

  • PDF

Numerical Investgation of the Effect of Turbulent Flow on Fish Passing through Hydroturbine Draft Tube (수력터빈 드래프트관을 통과하는 물고기에 미치는 난류의 영향 수치모의)

  • Paik, Joong-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.5 s.154
    • /
    • pp.365-377
    • /
    • 2005
  • This paper presents numerical works carried out for developing an advanced computational framework for understanding injury- and mortality-inducing flow phenomena in hydropower facilities. Large-eddy simulation (LES) of a circular jet flow is carried out to help interpret the results of recent experiments that exposed live fish to the shear zone of a turbulent jet. The instantaneous flow field of LES is characterized by intense velocity, pressure, and vorticity fluctuations, which could exert forces and moments on a fish considerably larger than those exerted by the same fish exposed to the corresponding steady, time-averaged flow. In this study, also, unsteady modeling of flow in a hydroturbine draft tubewas carried out using a hybrid unsteady RANS/LES, so-called detached-eddy simulation (DES). Results from DES show that the potential for disorientation and excessive residence times of fish within the draft tube is certainly considerable.

Preparation and Characterization of Nano-sized Hydrogels (nanogels) Using Inverse-miniemulsion Polymerization Method for Protein Drug Delivery (단백질 약물 전달을 위한 Inverse-miniemulsion Polymerization 방법으로 제조하는 나노크기의 수화젤(나노젤)의 제조 및 특성평가)

  • Kang, Soo-Yong;Munkhjargal, Odonchimeg;Kim, Seong-Cheol;Park, Ah-Reum;Shim, Young-Key;Lee, Woo-Kyoung
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.73-78
    • /
    • 2010
  • Hydrogels are thought to be a promising delivery carrier for protein drugs because of their favorable aqueous environment compared with nano/micro-particles of hydrophobic polymer such as PLGA. In this study, nano-sized hydrogels (nanogels) were fabricated using inverse-miniemulsion polymerization method. The mean size of nanogels in range of 90-160nm and affected by the preparation parameters such as sonication time and concentration of monomer. While longer sonication time and lower concentration of acrylamide monomer showed a tendency to produce smaller nanogels and to have lower lysozyme activity, variation of bis-methylene acrylamide concentration made no difference. Although both longer soncaton time and lower acrylamide concentration increased in vitro release rate, acrylamide concentration was more effectively affected to the control of protein release rate, which indicated that the release rate of protein from nanogels affected by not only their size but also internal structure. In conclusion, nanogels prepared by inverse-miniemulsion can be a useful carrier for application of protein drug, because of simple process, minimum contact of organic solvent and high protein activity.

Study on Preparation and Quality of Jellies using Mushrooms (버섯을 이용한 젤리 제조 및 품질특성에 관한 연구)

  • 정기태;주인옥;최정식;최영근
    • The Korean Journal of Food And Nutrition
    • /
    • v.14 no.5
    • /
    • pp.405-410
    • /
    • 2001
  • Mushroom jellies using extracts of Garnoderma lucidum, Lentinus edodes, Pacilomyces ten tenuipes and Cordyceps militaris were prepared, and Investigated the colors, texture and sensory characteristics of mushroom jellies. G. lucidum jelly mixed 85% mushroom, 10% jujube(Zizyphus jujuba Miller) and 5% hwanggi (Astragaslus membranaceus) extract, L. edodes jelly mixed 80% mushroom, 10% jujube, 5% gamcho( Glycyrrhiza uralensis) and 5% omija (Schizandrae chinensis Ruprecht) extract. and P. tenuipes and C. militaris jelly mixed 85% mushroom. 10% jujube and 5% gamcho extract were most effective in overall acceptability. The Jellying ability of carrageenan was better than other jelling agents. According to increase carrageenan content, color of mushroom Jellies were not effect. however hardness, gumminess and chewiness were increased. Sensory evaluation of mushroom Jellies were most preferable at the 0.6% carrageenan content.

  • PDF

Isolation and Identification of Proteins Increasingly Expressed in Beef Loin on Maturation (성장기 소의 등심에 발현되는 단백질들의 분리 및 동정)

  • Hwang, Sun-Il;Lim, Jin-Kyu
    • Applied Biological Chemistry
    • /
    • v.42 no.1
    • /
    • pp.39-44
    • /
    • 1999
  • Protein profiles of beef loin were constructed by comparing two-dimensional gel electrophoresis patterns of the proteins from different growth stages of Hanwoo, Korean cattle. Proteins from the lean muscle of 0, 6, 12 and 24 months old Hanwoo were separated by isoelectric focusing (IEF) on 16 cm tube gels, and further processed second dimensionally by 12% SDS-polyacrylamide gel electrophoresis (PAGE) using $18{\times}20$ cm gel. Proteins with pI values ranging 3.0 to 9.0 and molecular weight of 15 to 100 kDa could be clearly detected on gel by silver staining. Interestingly, many of the proteins significantly increased and decreased during growth happened to be low molecular ones. To isolate the increased proteins, the soluble proteins were obtained from the tissue by 1% Triton X-100 extraction, then, fractionated by 30% and 50% ammonium sulfate. The isolation condition of each particular protein was determined. According to the conditions, two of the increased proteins were isolated, and transferred to PVDF membrane and microsequenced.

  • PDF