Piping Analysis of Reservoir Embankment due to Leakage of Buried Box Culvert (저수지 제체 내 배수통관의 누수로 인한 파이핑 분석)

  • Kim, Han il;Yang, Hak Young;Kim, Young Muk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.787-799
    • /
    • 2017
  • Although the long-term leakage between the box culvert and the soil contact surface is one of the main causes of the failure in the embankment of the reservoir, there is a little studies on this matter. If a leakage occurs by the structure such as the buried box culvert of reservoir embankment is partially damaged, it is difficult to observe and there is a possibility of damage caused by piping. For these reasons, more research is necessary. In this study, the embankment type of the reservoir is divided into the core type and the homogeneous type when the damaged box culvert passing through the embankment of the reservoir is leaked due to the differential behavior of materials like differential settlement. In view of the condition, the seepage analysis of 2D was performed according to the water level change. The result of the study shows that the possibility of piping increases at the upper part rather than the bottom part of the box culvert when the leakage occurs to the box culvert passing through the embankment of the reservoir. Particularly, it is considered that the presence of the core helps to maintain the seepage stability of the embankment in case where the leakage occurs at the downstream side of the embankment. Also, if there is a drastic decrease on the internal pore water pressure in the embankment of reservoir, it is necessary to consider the possibility of piping.

Safety Index Evaluation from Resistivity Monitoring Data for a Reservoir Dyke (전기비저항 상시관측에 의한 제체 안전도 지수 산출)

  • Cho, In-Ky;Kang, Hyung-Jae;Lee, Byoung-Ho;Kim, Byoung-Ho;Yi, Sang-Sun;Park, Young-Gyu;Lee, Bo-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.2
    • /
    • pp.155-162
    • /
    • 2006
  • An abnormal seepage flow, which is mainly caused by the piping, is one of the major reasons for embankment dam failure. A leakage detection is therefore a vital part of an embankment dam's monitoring. Resistivity method, which is an efficient tool to detect leakage zones, has been used all over the world for an embankment dam's monitoring. Although the resistivity method gives us very useful information about the leakage problem, there is no more quantitative interpretation than the low resistivity zones in the 2-dimensional resistivity section are regraded simply as the anomalous seepage zones. Recently, resistivity monitoring technique is applied for the detection of leakage zones. However, its interpretation still remains in the stage of presenting the resistivity ratio itself. An increased seepage flow increases a porosity and an increasing porosity decreases the dam's stability. Therefore, the porosity is one of the major factors for an embankment dam's stability. Based on Archie's experimental formula, we try to evaluate a porosity distribution from the resistivity data which is obtained on the dam's crest. We also attempt to represent a procedure to evaluate a safety index of the embankment dam from the resistivity monitoring data.

A Study on Levee Infiltration Failure and Design of Countermeasures (하천 제방의 침투 파괴에 대한 대책공 설계방법 고찰)

  • Lee, Nam-Joo;Yu, Kwon-Kyu;Lee, Sang-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1857-1861
    • /
    • 2010
  • 이 연구는 하천 제방의 누수 문제에 대해서, 누수의 실태, 대책공 및 조사 방법에 관한 사례를 수집 정리하는 동시에, 이들 사례에 기반한 누수 특성, 하천 특성에 따른 대책공 및 조사 방법에 대해서 검토하기 위한 목적으로 수행하였다. 제방 누수는 일반적으로는 하천수가 제체 또는 기초 지반에 침투해서 제방의 제내 비탈면, 제내 비탈끝 또는 제내지에서 스며나오는 현상을 총칭하며, 각 누수 형태의 개념과 특징을 정리하였다. 1987년 일본의 건설성 하천국의 토목연구소에서 수행한 약 300건의 누수사례에 관한 검토보고서를 참고하여 일본의 하천 제방의 누수 특징을 요약 정리하였다. 제방의 침투/누수 대책 공법을 4가지로 분류하여 특징을 정리하였다. 하천 제방의 제체 누수에 대한 제방 강화 대책 공법의 선정 과정 및 지침을 제시하고자 한다.

  • PDF

Dam seepage investigation using two- and three-dimensional resistivity surveys (2차원 및 3차원 전기비저항 탐사를 이용한 제당 누수 조사)

  • Yi Myeong-Jong;Kim Jung-Ho;Song Yoonho;Chung Seung-Hwan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.41-53
    • /
    • 2000
  • Electrical resistivity survey is widely applied to the dam seepage problems. Main purpose of the resistivity survey is to delineate the inhomogeneity in the dam. In this study, two- (2-D) and three-dimensional (3-D) resistivity survey methodology and corresponding interpretations of the data have been analyzed using 3-D resistivity modeling results. Since resistivity structures beneath the dam and its shape are 3-D in nature, we could get more accurate image of the dam structures using 3-D survey compared to 2-D survey even though we cannot employ the grid-shape survey layout.

  • PDF

Physical Model Experiment on the Seepage Characteristics through a Dam by using FDR Sensor (FDR 센서를 활용한 제체 누수특성의 실내 모형 실험 연구)

  • Kim, Gyoo-Bum;Im, Eunsang;Ryu, Ho-Cheol;Hwang, Chan-ik;Kim, Hyeong-Jong
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.715-726
    • /
    • 2018
  • Various methods, such as geophysical exploration, temperature measurement, and fiber optics, have been developed for detecting the seepage at a dam. In this study, in order to investigate the possibility of leakage detection using dielectric constant of FDR sensor, a physical model consisting of weak and no-weak zones is fabricated and the sensors for dielectric constant, temperature and pore water pressure measurements are installed. As a leakage happens, the dielectric constant changes more rapidly through a weak zone than no-weak zone. In addition, comparing three factors (dielectric constant, temperature, and pore water pressure), the response of dielectric constant to seepage is fast and it is easily recognized even at the end measurement point. Considering these features, it is concluded that it could be possible to cope with the leakage detection quickly and efficiently if the dielectric constant is measured at the downstream slope of a dam.

Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments (저수지의 유지관리를 위한 전기비저항모니터링 기법 응용)

  • Park Sam Gyu;Kim Jung-Ho;Seo Goo Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The subject of this paper is research into the application of electrical resistivity monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity measurement, inclinometer, piezometer, and water gauge at an embankment. Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variant images of electrical resistivity at the embankment were provided from the monitoring data and we could accurately locate the portion of which resistivities have sharply changed. Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity data and hydrological data would be much more preferable to performing the just one-time measurements.

A Study on Seepage Control of Levee with Pervious Toe Drain (본배수공을 이용한 하천제방의 침윤조절에 관한 연구)

  • Lee, Sang-Ho;Kong, Young-San;Lee, Nam-Joo;Yu, Kwon-Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.162-166
    • /
    • 2011
  • 하천제방은 가장 치수효과가 높은 홍수방어시설로서 홍수 시 유수를 원활하게 소통시키고 제내지를 보호하기 위해 하천을 따라 축조한 시설이다. 누수에 의한 제방파괴는 제내지 제체에 드러난 포화표면이 결정적인 요인이 되므로 침윤선을 낮추어 제체하부에 위치하도록 해야 하며 누수가 발생한 제방에 대해서는 적절한 보강기법을 적용해야 한다. 본 연구에서는 하천제방 축조 또는 보강 시 누수에 의한 파괴를 방지하기 위한 방법으로 미국 공병단과 일본 국토기술연구센터에서 사용하는 기법 중 하나인 배수공을 두어 침윤선을 조절하는 방법을 적용하였다. 구체적으로 공병단과 일본 국토기술연구센터에서 제시하는 배수공을 가지는 경우의 제방 실험 및 수치 모형 보정 결과를 비교하였다. 침투 수치 모의는 SEEP/W 프로그램으로 검토하였다. 실험에 적용한 제방의 규격은 제방폭 2.6 m, 둑마루폭 0.4 m, 사면경사 1:2, 제방 높이 0.55 m, 수위 0.5 m이다. 배수공이 없는 제방은 사면에서 누수가 발생하였으며, 배수공 바닥폭이 0.4 m인 공병단과 일본 국토기술연구센터에서 제시하는 배수공을 설치하였을 때는 누수가 발생하지 않았다. 같은 배수공 바닥폭을 가지는 공병단과 일본 국토기술연구센터식 배수공을 설치한 제방의 실험을 비교한 결과, 일본국토기술연구센터식 배수공을 설치한 제방의 침윤선이 공병단식 배수공을 설치한 제방보다 낮았다. 즉, 일본 국토기술연구센터식 사각형 배수공이 다소 안정한 것으로 분석되었다.

  • PDF

Seepage Behaviors of Enlargement Levee Containing Box Culvert Constructed on Soft Ground (연약지반에 설치된 배수통문을 포함하는 하천 보축제체의 수문 위치에 따른 침투 거동)

  • Yang, Hak-Young;Kim, Young-Muk
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.3
    • /
    • pp.29-41
    • /
    • 2018
  • In the case of the enlargement levee on the soft foundation, the existing levee and the enlargement levee connection can be damaged due to heterogeneous subsidence such as differential settlement at the joint of the box culvert passing through the levee. This study selected the downstream region of the Geum River and then confirmed the influence of the piping possibility on the levee by performing a 2D seepage analysis and analyzing the seepage tendency according to the position of the box culvert's gate. As a result, the flow velocity and the hydraulic gradient are larger in the upper breakage than the lower breakage, and the upper leak was more vulnerable to the piping than the lower leak. If leaks occur in the gate located on the riverside land, the risk of piping is increased when the water level rises and is maintained highly. In the case of the gate located on the inland, it could be predicted that the leakage could damage the stability of levee by increasing the water pressure inside the levee. As a result, if leakage occurs at any position in the box culvert, the pore water pressure is increased or decreased compared with the case when no leakage occurs. Therefore, if the pore water pressure is drastically reduced or increased compared with the normal case, leakage may occur. However, the result of this study is based on a 2D seepage analysis, and it is likely to be different from actual cases. Therefore, more detailed analysis by 3D analysis is recommended.

Safety Assessment of Embankment by Analysis of Electrical Properties (전기비저항 물성 분석을 통한 제체의 안정성 검토)

  • Oh, Seok-Hoon;Suh, Baik-Soo
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.245-255
    • /
    • 2008
  • The variation of the electrical property of embankment material was analyzed from laboratory experiments and the result of field survey, in order to enhance the interpretation of electrical resistivity survey frequently used for safety assessment of embankment. At first, the kaolinite, showing similar physical property with core material of embankment, was used to examine the variation of the resistivity value according to degree of consolidation. The test showed that a drop of shear strength induces increase of resistivity value regardless of degree of water content. This result means that porous zones of weak core material in embankment may be appeared as highly resistive part in the electrical resistivity survey. This observation implies that it may fail to detect weak core material by electrical method, if we only try to and zones showing low resistivity value. And, we performed Standard Penetration Test (SPT) to analyze the correlation between electrical property and ground stiffness. Finally, a mechanism to describe the variation of electrical resistivity due to grouting effect was proposed and real field data were analyzed.

Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities (수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구)

  • Park, Sam-Gyu;Kim, Jung-Ho;Seo, Goo-Won;Won, Jong-Geun;Kim, Byung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.71-76
    • /
    • 2005
  • The subject of this paper is research into the application of resistivity/SP monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity/SP measurement, inclinometer, piezometer, and water gauge at an embankment, Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and SP variations that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variations of resistivity and SP at the embankment were provided from the monitoring data and we could accurately locate the portions of which resistivities and SP have sharply changed, Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity and SP, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity and SP data would be much more preferable to performing the just one-time measurements.

  • PDF