• Title/Summary/Keyword: 제염

Search Result 553, Processing Time 0.026 seconds

Removal and Decomposition of Impurities in Wastewater From the HyBRID Decontamination Process of the Primary System in a Nuclear Power Plant (원전 일차계통 HyBRID 제염공정 발생 폐액 내 불순물 제거 및 분해)

  • Eun, Hee-Chul;Jung, Jun-Young;Park, Sang-Yoon;Park, Jeong-Sun;Chang, Na-On;Won, Hui-Jun;Sim, Ji-Hyoung;Kim, Seon-Byeong;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.4
    • /
    • pp.429-435
    • /
    • 2019
  • Decontamination wastewater generated from the HyBRID decontamination process of the primary system in a nuclear power plant contains impurities such as sulfate ions, metal ions containing radioactive nuclides, and hydrazine (carcinogenic agent). For this reason, it is necessary to develop a technology to remove these impurities from the wastewater to a safe level. In this study, it has been conducted to remove the impurities using a decontamination wastewater surrogate, and a treatment process of the HyBRID decontamination wastewater has been established. The performance and applicability of the treatment process have been verified through 1 L scale of replicates and a pilot scale (300 L/batch) test.

플라즈마트론을 이용한 금속 방사성 폐기물 제염처리연구

  • Yang, Ik-Jun;Yang, Jong-Geun;Kim, Seung-Hyeon;SURESH, RAI;Ahmed, M.W.;Shaislamov, Ulugbek;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.116.1-116.1
    • /
    • 2015
  • 원자력 발전소 고리 1호기의 해체가 결정됨에 따라 발전소를 구성한 금속기기의 제염처리가 대두되고 있다. 금속 방사성폐기물 중 상당수는 그 자체가 방사성 오염 물질이라기보다는 오염 핵종이 표면에 부착하고 있는 경우가 많아 제염 공정을 거쳐 폐기한다면 보관해야 하는 양을 획기적으로 줄일 수 있을 것이다. 이에 따라 본 연구실에서는 플라즈마트론을 이용한 방사성 폐기물 건식제염처리에 대하여 연구하였다. 본 실험에서는 방사성을 띄지 않는 동위원소 Co sheet와 DC 플라즈마트론을 사용하였다. Ar 1000 sccm을 고정으로 비율(10:0, 9:1, 8:2, 7:3, 6:4), 거리(20 mm, 30 mm 40 mm), 시간(60 sec, 120 sec, 180 sec)을 변수로 두어 실험하였다. 결과적으로 기체의 혼합비가 4:1일 때 최대 식각율 $9.24{\mu}m/min$을 확인했다.

  • PDF

LOMI 제염제의 전기화학적 제조시 PICOLINIC ACID 첨가의 영향

  • 박상윤;문제권;심준보;최왕규;정종헌;오원진
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.929-936
    • /
    • 1995
  • LOMI 제염제의 전기화학적 제조공정 중 전하운반체의 역할 및 V$^{3+}$ 이온의 침전현상을 방지하기 위하여 첨가되는 과량의 formic acid 는 제염제 제조시에는 중요한 역할을 하지만 제염 폐기물의 양을 증가시키는 요인이 되기도 한다. EPRI 공정에서는 formate : V 의 비율(FVR)이 10:1 인 조건에서 V$^{2+}$-formate 를 제조한 후 음이온 교환 수지를 이용하여 과량의 formate 를 제거하는 공정을 사용한다. 이러한 방법으로 줄일 수 있는 FVR의 한계가 약 2.5 : 1 이다. 본 연구에서는 제염제 중 formate 의 양을 더욱 줄일 수 있는 방법으로써 V$^{2+}$-formate 제조시 용액 중에 picolinic acid를 미리 첨가하는 영향을 조사하였다. V$^{2+}$ 이온의 농도가 0.1 M 일 때 FVR 를 1.5:1 까지도 줄일 수 있음을 확인하였다.

  • PDF

수지충전식 전기투석 재생조를 이용한 LOMI 제염폐액의 전기화학적 재생연구

  • 심준보;박상윤;문제권;오원진;김종득
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.207-212
    • /
    • 1996
  • 실증규모의 수지충전식 전기투석 재생조를 사용하여 농축음극액내 바나듐의 전기화학적 환원 방법에 의한 재생거동을 조사하였다. 전기투석 분리재생 종료후 남아있는 개미산용액을 전해액으로 사용한 농축음극액내 전기투석된 철 및 코발트는 음극액의 pH를 약 4.3내외로 조절하면 전해환원에 의해 전착.제거된다. 또한 농축음극액내 바나듐은 +2가로 전해환원 되어 착화물을 이루고 있는 Vanadous picolinate 형태로 존재하기 때문에 음극액은 농축된 LOMI 제염제로 재생된다. 이 전해환원에 의한 농축음극액의 재생방법은 제염폐액의 전기투석 분리재생 후 피콜리네이트 착화제만을 재사용하는 기존의 재생개념보다 더욱 효과적으로 제염폐액을 재생시켜 재활용할 순 있는 방사성폐기물의 감용효율이 큰 향상된 제염폐액 재생공정이다.

  • PDF

원자력시설의 제염해체 공정중 분진처리 성능평가

  • 이기원;최병선;이후근;오원진;이병직;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.307-312
    • /
    • 1997
  • 원자력시설의 콘크리트 표면제염 및 절단을 효과적으로 수행하기 위해서는 먼저 방사성물질이 제염구역의 외부로 누출되지 않도록 작업구역을 비방사성 구역과 분리하고, 국부적으로 오염된 콘크리트 표면을 제염하는 기술, 해체 절단하는 기술 및 경제적인 방법으로 방사성물질의 확산을 최소화하는 분진제거 기술 등이 개발되어야 한다. 따라서 본 논문에서는 원자력시설의 콘크리트 표면제염 및 절단시 발생되는 콘크리트 분진처리 필터시스템을 개발하기 위하여, 중량 및 고밀도 콘크리트 내부로의 세슘 및 스트론튬 핵종의 침투깊이 실험을 수행하였으며, 다중 사이클론을 이용하여 DOP 에어로졸 및 콘크리트 표면절단 장비인 scabbier에 의해 발생한 중량 및 고밀도 콘크리트 분진의 특성을 분석하고 포집효율 성능시험을 수행하였다. 또한 사이클론 성능평가 프로그램을 작성하여 사이클론의 포집효율을 예상하였으며 이를 실험값과 비교하였다.

  • PDF

Decontamination Performance Assessment for the Plasma Arc Vitrification pilot plant on the basis of Trial Burn Results(I) - Decontamination Characteristics for Hazardous Metal, Radioactive surrogate and Radioactive Tracer in Off-gas (시험연소결과에 근거한 플라즈바 아크방식 유리화 시험 설비의 제염성능 평가(I) - 배기가스중의 유해중금속, 방사성핵종 모의물질 및 방사성핵종 제염특성 -)

  • Chae, Gyung-Sun;Park, Youn-Hwan;Min, Byong-Yun;Chang, Jae-Ock;Park, Jun-Yong;Jeong, Weon-Ik;Moon, Byung-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.99-107
    • /
    • 2000
  • Through the results of off-gas analysis at 3 sampling points in Plasma Arc Melting vitrification pilot plant, it was evaluated the partitioning of spiked materials in off-gas and the decontamination characteristic of off-gas treatment system. Spiked materials are hazard_us heavy metals(Pb, Cd, Hg), radioactive surrogate(Co, Cs) and radioactive materials($^{60}Co,\;^{137}Cs$). Through the Trial burn tests, Decontamination factor of spiked materials in off-gas treatment system is calculated.

  • PDF

Increase of Electrokinetic Soil Remediation Efficiency using Ethanoic Buffer (초산완충액에 의한 동전기적 토양복원 효과 증진 연구)

  • Kim, Gye-Nam;Oh, Won-Zin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2007-2016
    • /
    • 2000
  • After kaolin clay was compulsorily contaminated with $Sr^{2+}$ ion. the remediation characteristics by electrokinetic method were analyzed. In the first experiment. NaCl solution was used as an electrolyte to raise the electric field strength. After remediation for 0.8 days. the pH of the cathode side of the soil column was elevated from 4.0 to 11.7. and thereby precipitation $Sr(OH)_2$, started to be formed in the side. Therefore. efficiency of soil remediation was reduced significantly and the 32% of total $Sr^{2+}$ ion in the column was decontaminated in 6.7 days. In the second experiment. ethanoic buffer was injected in the soil column and $CH_3COOH$ was continuously inputted in cathode reservoir to restrain the pH elevation. The pH of the cathode side of the soil column was only ascended from 4.0 to 6.0 in 3.8 days and $Sr(OH)_2$ was not formed. The 21% of total $Sr^{2+}$ in the soil column was decontaminated in 0.6 days. and the 33% of total $Sr^{2+}$ in 0.9 days. and the 84% of total $Sr^{2+}$ in 1.6 days. and the 92% of total $Sr^{2+}$ in 2.5 days. and the 97% of total $Sr^{2+}$ in 3.8 days. Meanwhile. the residual concentrations in the column calculated by the developed model were similar to those by experiment.

  • PDF

Flow Characteristics Evaluation in Reactor Coolant System for Full System Decontamination of Kori-1 Nuclear Power Plant (고리1호기 계통제염을 위한 원자로냉각재내 유동 특성 평가)

  • Kim, Hak Soo;Kim, Cho-Rong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.389-396
    • /
    • 2018
  • The Kori-1 Nuclear Power Plant (NPP), WH 2-Loop Pressurized Water Reactor (PWR) operated for approximately 40 years in Korea, was permanently ceased on June 18, 2017. To reduce worker exposure to radiation by reducing the dose rate in the system before starting main decommissioning activities, the permanently ceased Kori-1 NPP will be subjected to full system decontamination. Generally, the range of system decontamination includes Reactor Pressure Vessels (RPV), Pressurizer (PZR), Steam Generators (SG), Chemical & Volume Control System (CVCS), Residual Heat Removal System (RHRS), and Reactor Coolant System (RCS) piping. In order to decontaminate these systems and equipment in an effective manner, it is necessary to evaluate the influence of the flow characteristics in the RCS during the decontamination period. There are various methods of providing circulating flow rate to the system decontamination. In this paper, the flow characteristics in Kori-1 NPP reactor coolant according to RHR pump operation were evaluated. The evaluation results showed that system decontamination using an RHR pump was not effective at decontamination due first to impurities deposited in piping and equipment, and second to the extreme flow unbalance in the RCS caused deposition of impurities.