• Title/Summary/Keyword: 제어흐름

Search Result 1,033, Processing Time 0.03 seconds

Implementation of a TCP/IP Offload Engine Using High Performance Lightweight TCP/IP (고성능 경량 TCP/IP를 이용한 소프트웨어 기반 TCP/IP 오프로드 엔진 구현)

  • Jun, Yong-Tae;Chung, Sang-Hwa;Yoon, In-Su
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.4
    • /
    • pp.369-377
    • /
    • 2008
  • Today, Ethernet technology is rapidly developing to have a bandwidth of 10Gbps beyond 1Gbps. In such high-speed networks, the existing method that host CPU processes TCP/IP in the operating system causes numerous overheads. As a result of the overheads, user applications cannot get the enough computing power from the host CPU. To solve this problem, the TCP/IP Offload Engine(TOE) technology was emerged. TOE is a specialized NIC which processes the TCP/IP instead of the host CPU. In this paper, we implemented a high-performance, lightweight TCP/IP(HL-TCP) for the TOE and applied it to an embedded system. The HL-TCP supports existing fundamental TCP/IP functions; flow control, congestion control, retransmission, delayed ACK, processing out-of-order packets. And it was implemented to utilize Ethernet MAC's hardware features such as TCP segmentation offload(TSO), checksum offload(CSO) and interrupt coalescing. Also we eliminated the copy overhead from the host memory to the NIC memory when sending data and we implemented an efficient DMA mechanism for the TCP retransmission. The TOE using the HL-TCP has the CPU utilization of less than 6% and the bandwidth of 453Mbps.

A Study on Development of Gas Accident Management System based on GIS (GIS 기반의 가스사고 관리시스템 개발에 대한 연구)

  • Kim, Kye-Hyun;Kim, Tae-Il
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2002.03a
    • /
    • pp.106-112
    • /
    • 2002
  • 최근 급속한 도시의 팽창 및 신도시 건설과 산업의 발전으로 가스시설은 꾸준히 확대되고 있는 실정이다. 그리고 94년 아현동 도시가스사고와 95년 대구 도시가스사고 이후로 도시 가스 시설물의 대한 안전 대책 및 시설물 관리에 대한 국민들의 관심이 증대되었다. 이러한 흐름에 따라 가스회사들은 GIS 기술을 도입하여 기존에 수작업으로 관리되고 있는 가스시설 정보체계를 전산화하여 항상 최신의 현황을 유지하고, 사고 발생시 신속한 대처 방안 및 피해예측을 위한 시스템을 개발하기 위하여 많은 연구를 진행하고 있는 실정이다. 본 연구의 목적은 안전이 중요시되는 가스시설물에 대하여 가스사고 발생시 신속한 대처 및 처리방안을 제시할 수 있는 GIS 기반의 가스사고 관리시스템을 개발하는데 있다. GIS의 가스사고 관리시스템에서는 사고 발생시에 시설물 관리자가 사고 지점을 선택하여 우선적으로 공급을 중단해야 할 관로를 제시하고 사고지점을 검색하여 차단해야 할 밸브에 대한 정보를 신속히 제공하여 대응 방안을 제시 할 수 있도록 하였다. 아울러 가스공급이 중단되는 지역에 대한 정보를 추출하여 피해범위를 산정하여 효율적인 사고 관리를 지원하도록 구성되었으며, 이와 함께 잔존가스량을 구하여 사고후의 대처방안을 마련할 수 있는 기능을 제공하도록 하였다. 향후 연구과제로는 원격으로 가스 시설물을 감시하고 제어할 수 있는 원격감시/제어시스템(SCADA System)과 연계를 통하여 가스사고 후에 신속한 피해예측 및 피해를 최소화 할 수 있는 방안제시 및 GPS를 활용하여 신속한 사고처리를 할 수 있는 활용 방안을 연구하여 체계적이고 종합적인 가스사고의 관리가 필요하다고 사료된다. 또한, 사고 후의 긴급 대처방안 뿐만 아니라 잔존가스량을 이용하여 수용가에 가스의 신속한 재공급을 위한 정보의 제공까지 한 단계 발전된 시스템의 개발이 추진되어야 한다.남산지역에 대해 정사영상과 10m간격의 DEM을 제작하였으며 1:1000 수치지도를 통해 제작된 DEM과 비교한 결과 총 43990개 격자점의 표고 차이는 평균 5.98m였다.여재 높이 100 cm에서 원수를 하향류 및 상향류로 주입하면서 하향류 20, 40, 80, 100 cm, 상향류 20, 40, 60, 80, 100 cm에서 시료를 채취하여 분석한 결과 모두 원수가 주입되는 부근 여재 높이 20 cm에서 가장 많이 제거되었다. 상향류 보다 하향류로 원수를 주입했을 때 제거효율이 높았다. $Fe^{+++}$$Fe^{++}$로 환원하는 $O^{-}_{2}{\cdot}$의 작용을 대신할 수 있음을 증명하며 이와같은 ascorbate 의존적인 $OH{\cdot}$ 의 생성은 ascorbate가 조직손상에 관여할 가능성을 시사하였다.었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin의 작용(作用)에 의(依)한 것이며, 이는 한의학(韓醫學) 방제(方劑) 원리(原理)인 군신좌사(君臣佐使) 이론(理論)에서 군약(君藥)이 주증(主症)에 주(主)로 작용(作用)하는 약물(藥物)이라는 것을 밝혀주는 것이라고 사료(思料)된다.일전 $13.447\;{\mu}g/hr/g$, 섭취 7일중 $8.123\;{\mu}g/hr/g$, 절식 14일후 $10.612

  • PDF

Short -term changes of microbial communities after control of Cochlodinium polykrikoides by yellow clay and chemical compound dosing in microcosm experiments (황토와 화학물질 살포에 의한 적조생물Cochlodinium polykrikoides 제어에 따른 미소생물그룹의 단주기변화)

  • Baek, Seung Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2971-2977
    • /
    • 2015
  • This study aimed to understand the changes in microbial community after algicide dosing to control the fish-killing dinoflagellate Cochlodinium polykrikoides in 10L microcosm. Based on our microcosm experiments, the algicidal activity for C. polykrikoides of yellow clay at the concentrations of 4g and 10g per 10 L was < 20%. At $0.8{\mu}M$ concentration of thiazolidinedione(TD49), the population of C. polykrikoides was controlled to be > 85%. In microbial community, a significant increase in heterotrophic bacterial (HB) abundance was observed at day 1 in the TD49 and yellow clay treatments including control. The HB remained high for 2 days and then gradually decreased. In contrast, the abundance of heterotrophic nanoflagellates (HNFs) increased significantly on days 3 and 5 in the TD49 treatments, indicating that the decline in HB was probably a result of predation by the high density of HNFs. In addition, fluctuations in the aloricate ciliate Uronema sp., which feed on bacteria, was clearly correlated with fluctuations in HB abundance, with a lag period of 1-3 days. Therefore, the short-term responses of the HNF and Uronema sp. may have been a result of the rapidly increasing of HB abundance, which is related to degradation of the dense C. polykrikoides bloom, particularly in the TD49 treatment. In addition, large aloricate ciliate Euplotes sp. was significantly increased after reproduction of HNFs and Uronema sp. Consequently, the algicide TD49 had positive effect on the microbial communities, which indicates that the microbial loop was temporarily enhanced in the microcosm by energy flow from HB through HNFs to ciliate.

Low-Power Motion Estimator Architecture for Deep Sub-Micron Multimedia SoC (Deep Submicron 공정의 멀티미디어 SoC를 위한 저전력 움직임 추정기 아키텍쳐)

  • 연규성;전치훈;황태진;이성수;위재경
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.95-104
    • /
    • 2004
  • This paper propose a motion estimator architecture to reduce the power consumption of the most-power-consuming motion estimation method when designing multimedia SoC with deep submicron technologies below 0.13${\mu}{\textrm}{m}$. The proposed architecture considers both dynamic and static power consumption so that it is suitable for large leakage process technologies, while conventional architectures consider only dynamic power consumption. Consequently, it is suitable for mobile information terminals such as mobile videophone where efficient power management is essential. It exploits full search method for simple hardware implementation. It also exploits early break-off method to reduce dynamic power consumption. To reduce static power consumption, megablock shutdown method considering power line noise is also employed. To evaluate the proposed architecture when applied multimedia SoC, system-level control flow and low-power control algorithm are developed and the power consumption was calculated based on thor From the simulation results, power consumption was reduced to about 60%. Considering the line width reduction and increased leakage current due to heat dissipation in chip core, the proposed architecture shows steady power reduction while it goes worse in conventional architectures.

Analysis of S/W Test Coverage Automated Tool & Standard in Railway System (철도시스템 소프트웨어 테스트 커버리지 자동화 도구 및 기준 분석)

  • Jo, Hyun-Jeong;Hwang, Jong-Gyu;Shin, Seung-Kwon;Oh, Suk-Mun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4460-4467
    • /
    • 2010
  • Recent advances in computer technology have brought more dependence on software to railway systems and changed to computer systems. Hence, the reliability and safety assurance of the vital software running on the embedded railway system is going to tend toward very critical task. Accordingly, various software test and validation activities are highly recommended in the international standards related railway software. In this paper, we presented an automated analysis tool and standard for software testing coverage in railway system, and presented its result of implementation. We developed the control flow analysis tool estimating test coverage as an important quantitative item for software safety verification in railway software. Also, we proposed judgement standards due to railway S/W Safety Integrity Level(SWSIL) based on analysis of standards in any other field for utilizing developed tool widely at real railway industrial sites. This tool has more advantage of effective measuring various test coverages than other countries, so we can expect railway S/W development and testing technology of real railway industrial sites in Korea.

A Study on the Performance Evaluation Measures of Traffic Signal Operation at Signalized Intersections by Utilizing Historical Data from Advanced Traveller Information System (첨단 교통 정보 시스템 누적 소통정보를 활용한 신호교차로 운영개선 효과평가를 위한 혼잡강도 지표 연구)

  • Cho, Yong-bin;Kim, Jin-tae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.643-654
    • /
    • 2018
  • In order to understand and manage traffic flows in urban areas in the past, a variety of traffic engineering theoretical indicators such as intersection lag and highway speed have been applied. However, these theories and indicators have been developed under the constraints of traffic engineering research before the construction of intelligent transportation system. Since the ATIS system currently exists, it is necessary to introduce a separate traffic engineering technology that utilizes the data. In this paper, it is aimed to confirm whether it is applicable to intermittent flow (approach road, intersection, control group, main road axis) by using 'congestion intensity' which is already used in traffic engineering field. The results of this study are as follows: (1) The traffic signal improvement effect of urban road access road, intersection road, control group, Two verification studies were performed to verify the derived congestion intensity index. (1) verification of congestion intensity threshold value analysis and (2) crossing improvement using the congestion intensity. Through verification, it was confirmed that it is possible to apply the congestion intensity in the inter - city intermittent flow using the 5 - minute unit speed data so as to be able to escape from the existing traffic signal operation management which is past passive and manpower limit.

A Study on the Atmospheric Pressure Control of the VARTM Process for Increasing the Fiber Volume Fraction and Reducing Void (섬유부피분율 증가와 공극 감소를 위한 VARTM 공정의 대기압 제어에 관한 연구)

  • Kwak, Seong-Hun;Kim, Tae-Jun;Tak, Yun-Hak;Kwon, Sung-Il;Lee, Jea-Hyun;Kim, Sang-Yong;Lee, Jong-Cheon
    • Composites Research
    • /
    • v.34 no.2
    • /
    • pp.88-95
    • /
    • 2021
  • VARTM (Vacuum-assisted resin transfer molding) process is a low-cost process technology and affiliated with OoA (Out of Autoclave). Besides, it has been widely used in various fields. However, because of its lower quality than the autoclave process, it isn't easy to apply the VARTM process to the aerospace industry, which requires high reliability. The main problem of the VARTM process is the loss of mechanical properties due to the low fiber volume fraction and high void content in comparison to the autoclave. Therefore, many researchers have studied to reduce void and increase fiber volume fraction. This study examines whether the method of controlling atmospheric pressure could increase the fiber volume fraction and reduce void during the resin impregnation process. Reliability evaluation was confirmed by compressive strength test, fiber volume fraction analysis, and optical microscopy. As a result, it was confirmed that increasing the atmospheric pressure step by step in the VARTM process of impregnating the preform with resin effectively increases the fiber volume fraction and reduces void.

A Study for Failure Examples Including with Engine Oil Leakage, Poor Contact by Fin Damage and Vaporizer Inferiority on LPG Automotive (LPG 자동차의 엔진오일누설, 핀 손상에 의한 접촉불량, 베이퍼라이저 내부불량으로 인한 고장사례연구)

  • IL Kwon, Lee;Chang Ho, Kook;Sung Hoon, Ham;Seung Yong, Lee;Jae Gang, Lee;Seung Min, Han; Woo Chan, Hwang;Dae Cheon, Jang;Chang Bae, You;Jeong Ho, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.24-29
    • /
    • 2022
  • This paper is a purpose to Analyze and study the failure examples for a engine oil leakage of camshaft bearing seal, poor contact by computer connector fin damage and vaporizer inferiority on LPG automotive. The first example, when the researcher disassembled the cylinder head of engine to establish the cause for oil leakage, he confirmed the engine oil leakage by damaged between the engine intake camshaft bearing and seal part. The second example, the connector fin of power source line that control the starting of a car supplied with engine computer. As a result, it found the fact that the engine operation stopped because of cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phe cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phenomenon as thd gas didn't flow the vaporizer by foreign substance deposit. Finally, it supplied a small quantity gas from vaporizer to mix. As the computer controlling mix opening condition supplied a air as opening signal, the air and fuel became rarefied state. it knew that the engine didn't produce prpper power. Therefore, a car have to throughtly inspect not in order to arise the failure symptoms.

Electrochemical Mass Transport Control in Biomimetic Solid-State Nanopores (생체모사형 나노포어를 활용한 전기화학 기반 물질전달 조절 시스템)

  • Soongyu Han;Yerin Bang;Joon-Hwa Lee;Seung-Ryong Kwon
    • Journal of the Korean Electrochemical Society
    • /
    • v.26 no.4
    • /
    • pp.43-55
    • /
    • 2023
  • Mass transport through nanoporous structures such as nanopores or nanochannels has fundamental electrochemical implications and many potential applications as well. These structures can be particularly useful for water treatment, energy conversion, biosensing, and controlled delivery of substances. Earlier research focused on creating nanopores with diameters ranging from tens to hundreds of nanometers that can selectively transport cationic or anionic charged species. However, recent studies have shown that nanopores with diameters of a few nanometers or even less can achieve more complex and versatile transport control. For example, nanopores that mimic biological channels can be functionalized with specific receptors to detect viruses, small molecules, and even ions, or can be made hydrophobic and responsive to external stimuli, such as light and electric field, to act as efficient valves. This review summarizes the latest developments in nanopore-based systems that can control mass transport based on the size of the nanopores (e.g., length, diameter, and shape) and the physical/chemical properties of their inner surfaces. It also provides some examples of practical applications of these systems.

A Dynamic Queue Manager for Optimizing the Resource and Performance of Mass-call based IN Services in Joint Wired and Wireless Networks (유무선 통합 망에서 대량호 지능망 서비스의 성능 및 자원 최적화를 위한 동적 큐 관리자)

  • 최한옥;안순신
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5B
    • /
    • pp.942-955
    • /
    • 2000
  • This paper proposes enhanced designs of global service logic and information flow for the mass-call based IN service, which increase call completion rates and optimize the resource in joint wired and wireless networks. In order to hanve this logic implemented, we design a Dynamic Queue Manager(DQM) applied to the call queuing service feature in the Service Control Point(SCP). In order to apply this logic to wireless service subscribers as well as wired service subscribers, the service registration flags between the Home Location Register(HLR) and the SCP are managed to notify the DQM of the corresponding service subscribers’ mobility. Hence, we present a dynamic queue management mechanism, which dynamically manages the service group and the queue size based on M/M/c/K queueing model as the wireless subscribers roam the service groups due to their mobility characteristics. In order to determine the queue size allocated by the DQM, we simulator and analyze the relationship between the number of the subscriber’s terminals and the drop rate by considering the service increment rate. The appropriate waiting time in the queue as required is simulated according to the above relationship. Moreover, we design and implement the DQM that includes internal service logic interacting with SIBs(Service Independent building Blocks) and its data structure.

  • PDF