• Title/Summary/Keyword: 제어계측

Search Result 1,006, Processing Time 0.031 seconds

The Communication protocol proposal at Ad-hoc for Water-Treatment (수처리 계측제어망 Ad-hoc 적용시 데이터 신뢰성 확보를 위한 통신 프로토콜 제안)

  • Yu, Chool;Seo, Gang do;Choi, Hong yeol;Hong, Sung taek;Ji, Yu chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.984-987
    • /
    • 2013
  • In concept, such as the backup of wired network and disaster prevention network of water treatment measurement and control system, reliability and security of high level of sending and receiving data between the nodes must be ensured in Ad-hoc network construction. Rather than apply the common communication protocols of Ad-hoc network construction during the FA network of closed water treatment facility with the facility of a certain scale is concentrated contrast, and high characteristics of the water treatment system infrastructure, public facilities We have developed a specific protocol another that applies the OTP of communication frame of process control commands and H-ARQ with ZRP by applying the flexibility to time constraints such as precision industrial plants to ensure the safety and property of facility operation.

  • PDF

Recent Research Works on Chemiluminescence as Measures of Combustion Characteristics (화학발광을 활용한 연소계측 연구동향)

  • Seo, Seonghyeon;Moon, Insang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.73-84
    • /
    • 2014
  • The present paper includes recent research works on the estimation of physical properties like equivalence ratio and heat release rate of flame through chemiluminescence measurement. Modern combustion devices require a precise control to increase combustion stability as well as to suppress pollutant emissions. The determination of combustion characteristics from chemiluminescence provides practical advantages over other techniques. However, the technique is dependent on equivalence ratio, combustion pressure, inlet temperature, turbulent intensity and fuel type. The intensity ratio of $OH^*$ and $CH^*$ has a strong relation with an equivalence ratio for methane/air premixed flames. The global measurement of chemiluminescence is accepted as a good indicator for a global heat release rate.

Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network (수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발)

  • Yang, Seungyoun;Kim, Jintae;Oh, Hwanjin;Lee, Minwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.83-86
    • /
    • 2015
  • In this paper, we propose a real-tim measurement management system UI development linked the Water treatment facilities broadband Convergence Network. The sensor and the image data received by the server develop a program to interact with Web through water treatment facilities broadband convergence network. So, Separately develop UI capable of independently operating. Building a web server for remote monitoring of the transmission sensor and the image data. And Monitoring and control is possible the sensor data and image data through the Web-based UI. We can grasp the current state such as measurement time, concentration and depth of interface through the proposed real-time measurement management system UI development liked the water treatment facilities broadband convergence network. So, we can check in whether the normal operation of water treatment facilities and whether the casualties such as fire and security. As well as real time to see the information at a glance due to UI development can be raal-time monitoring of real-time measurement management system.

The Efficiency Evaluation of One Person Non-Prism Surveying System for Tunnel Measurement (터널계측을 위한 1인 무프리즘 측량시스템의 효율성 평가)

  • Park, Kyeong-Sik;Hahm, Chang-Hahk;Lee, Jae-Kee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.4
    • /
    • pp.89-96
    • /
    • 2007
  • The tunnel measurement data such as deficiency quantity, outbreak quantity, inner displacement and crown settlement are very important elements in tunnel sites under construction and obtained mostly by displacement gauge and total station. However, it is difficult and dangerous to install targets or measurement equipments on the points in tunnel construction site and also we need several persons to work in the tunnel. Non-prism total station with remote control system which is developed recently has various efficient functions for tunnel measurement. Therefore, for efficient tunnel measurement, this study suggested one person surveying system which consisted of non-prism total station and notebook PC to control total station remotely, and we evaluated the suggested tunnel measurement system. In this study, the tunnel site under construction was chosen as the test field and tunnel surveying was done by existing surveying method and suggested method separately. As result of the test, we analyzed processing time and accuracy to demonstrate the superiority of suggested one person non-prism surveying system.

  • PDF

Radiant Energy Filtering to Enhance High Temperature Measurement by a Thermography System (고온 계측 열화상 시스템 구현을 위한 복사에너지 필터링 연구)

  • Yoon, Seok Tae;Cho, Yong Jin;Jung, Ho Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.466-473
    • /
    • 2016
  • In a shipbuilding process, thermal damage to the ship structure at the rear end results from an excessive heat input and conduction during welding process. To prevent such damage, appropriate control of the heat input, based on welding temperature measurement, is required. For temperature measurement, contact and non-contact methods are available; the thermography system is a popular non-contact temperature measurement. When the intensity of radiation from a high-temperature object is excessive, however, detecting the sensors of ordinary thermography systems leads to an inability in measuring the temperature due to saturation. Hence, this study suggests use of a neutral density filter that prevents an excessive amount of radiation from being accumulated in a thermography system, and thus makes it possible to quantitatively measure an object's temperature as high as $3000^{\circ}C$.

TECHNICAL PAPERS : An Investigation on the Propellant Consumption Rate Gauged from the Low-Earth-Orbit Spacecraft (기술논문 : 저궤도 위성의 추진제 소모율 계측에 관한 고찰)

  • Kim,In-Tae;Heo,Hwan-Il;Kim,Jeong-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.1
    • /
    • pp.113-119
    • /
    • 2003
  • During the mission operation time, it is very important to estimate the spacecraft propellant remaining as accurately as possible. This is because the quantity of propellant is related directly to how long the satellite can be operated ín orbit. There are two different methods for spacecraft propellant gauging; the PVT method and the book-keeping method. This paper describes the characteristics and applications of these methods using the flight operation data of KOMPSAT-1. Additionally, propellant consumption rates in delta-V maneuvering and each attitude control submode are analyzed according to spacecraft operation modes. The earth search submode shows the highest propellant consumption rate.

Reproducing water flow using 3D game engine (3D게임엔진을 이용한 물 흐름 재현)

  • Woochul Kang;Eun-kyung Jang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.432-432
    • /
    • 2023
  • 한국건설기술연구원(Korea Institute of Civil Engineering and Building Technology, KICT)의 안동하천연구센터(Andong River Experiment Center, REC)는 다양한 하천 관련 실규모 실험을 수행하기 위해 3개의 수로를 보유하고 있다. 본 연구의 주목적인 실증 실험 계측 결과를 기반으로 3D 게임엔진을 이용하여 물 흐름을 재현하기 위해 A1 수로를 대상구간으로 설정하였다. 실증 실험의 경우 2개의 수문 개도율 조건에서 ADV와 ADCP를 활용하여 계측된 유량 및 유속 결과들을 비교하였으며, 추가적으로 영상 데이터로 부터 표면유속(LS-PIV)을 산정하였다. 3D 게임 엔진은 렌더링 엔진, 물리 엔진, 오디오 엔진, UI 시스템, 게임플레이 프레임워크 등이 잘 융합된 소스코드들과 개발자들이 이용하기 쉬운 방식으로 변환된 툴(tool)로 제공하여 현실 세계를 가상 세계에 시각화하여 구현하는데 큰 장점을 가지고 있다. 또한 기존의 흐름 재현이 가능한 수리/수문 모델링의 경우 특정한 목적으로만 이용가능하고 연산에 소용되는 시간 때문에 실시간 흐름재현이 어렵지만, 3D 게임엔진을 이용하는 경우 다양한 목적과 여러 분야와의 고려가 동시에 가능하며 연산의 단순화를 통해 실시간 흐름 재현이 가능하다는 장점이 있다. 본 연구에서는 언리얼 엔진의 Niagara Fluids와 Fluid flux 툴들을 활용하여 하천실증실험 시설 일부 구간에 대해 물 흐름을 재현하였다. 먼저 하천실험실증시설을 드론과 RTK-GPS를 이용하여 촬영된 결과를 정합하여 3D 게임엔진 기반 흐름 재현을 위한 지형 기초 자료를 구축하였다. 지형 계측 결과를 기반으로 A1 수로 전체 구간을 대상구간으로 설정한 이후 수문 조절을 통해 흐름 조건을 제어할 수 있도록 제작하였으며, 실제 흐름에 대한 계측 결과를 기반으로 재현된 흐름을 대상으로 material 값의 조정(방향 X, Y값을 RGB값으로 변환한 뒤 벡터 길이 값으로 환산)을 통해 0~100 사이 값을 이용하여 유속을 표현하였다. 최근 가상공간 (i.e. 디지털트윈) 관련 시장 성장이 매우 빠르고 다양한 사업에서 해당 기술의 수요가 증가하고 있으며, 본 연구를 통해 물 흐름의 디지털 트윈화를 위한 수단으로서 3D 게임 엔진의 활용 가능성을 확인하였다. 다만 실제 하천의 적용과 하천관리를 위한 실용화를 위해서는 추가적인 연구와 분석이 이루어져야 할 것이다.

  • PDF

Monitoring and Control System for Efficient Operating and Management of Photovoltaic Power Generation System (태양광발전시스템의 효율적 운용과 관리를 위한 모니터링 및 제어 시스템)

  • Bin, Jae-Gu;Kang, Feel-Soon;Kim, Cheul-U
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.532-539
    • /
    • 2007
  • Photovoltaic power generation system is one of new renewable energy sources. Such distributed power generation system has important issues for the system management ad operating after its installation. To solve the problem, remote monitoring and control systems can be employed. In this paper, LabVBEW based monitoring and control system is proposed for efficient management and operation of the photovoltaic power generation system. Interface method between monitoring part and DSP controller is given in detail. The proposed system is verified through experiments using a grid-connected photovoltaic power generation system.

Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System (스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선)

  • Jung, Hyung-Jo;Jung, Chan-Kuk;Choi, Kang-Min;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.37-46
    • /
    • 2006
  • In this study, the efficacy of the newly developed smart passive control system to improve seismic performance of base isolated building structures is numerically verified. The smart passive control system consists of a magnetorheological (MR) damper and an electromagnetic induction (EMI) part. The damping characteristics of an MR damper can be controlled by the current generated in an EMI part according to the Faraday's law of electromagnetic induction. An EMI part consisting of a permanent magnet and a solenoid coil could substitute a control system including sensors, a controller and an external power supply in a conventional smart control system. The benchmark control problem for a base isolated building presented by the american society of civil engineers is considered for numerical simulation. The control performance of the smart passive control system is compared to that of the conventional smart control system using MR dampers. It is demonstrated from the numerical simulation results that the smart passive control system is useful to improve the seismic performance of base isolated buildings.

Development of Control Method for Improving Energy Efficiency of Unmanned Underwater Gliders (무인 수중글라이더의 에너지 효율 개선을 위한 제어방법 개발)

  • La, Seung-kyu;Ko, Sung-hyup;Ji, Dae-hyeong;Chon, Seung-jae;Jeong, Seong-hoon;Choi, Hyeung-sik;Kim, Joon-young
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.2
    • /
    • pp.105-112
    • /
    • 2022
  • In this paper, unmanned underwater glider was designed for high-depth operation and adopted a bladder-type buoyancy controller for improving battery efficiency, and the motion controller controls the pitch angle by moving the internal mass battery. To improve the energy efficiency of the unmanned underwater glider, a layered PID controller that performs control by section was designed. Simulation program including 6-DOF motion equations and hydrodynamics coefficients of an unmanned underwater glider is constructed using Matlab/Simulink program. Control methods such as PID controller, sliding mode controller and layered PID controller were applied to the simulator to compare the dynamics performance and energy efficiency. As a result, the layered PID controller showed improved control performance compared to other controllers and improved energy efficiency of approximately 7.2% compared to PID controller.