• Title/Summary/Keyword: 제로에너지하우스

Search Result 34, Processing Time 0.025 seconds

ZeSH-II에 적용된 태양열+지열하이브리드시스템 사례

  • Kim, Yong-Gyeong;Im, Hyeong-Chan;Hong, Seong-Geun;Baek, Nam-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.40 no.5
    • /
    • pp.50-55
    • /
    • 2011
  • 에너지의 85% 이상이 자립형 주택인 제로에너지솔라하우스에 적용된 신재생에너지 기술 중 태양열+지열 하이브리드 시스템을 소개한다.

  • PDF

A Study on the Energy Self-Sufficiency of KIER Zero Energy Solar House II (제로에너지 솔라하우스(KIER ZESH-II)의 에너지 자립도에 대한 연구)

  • Jeong, Seonyeong;Baek, Namchoon;Yoo, Changkyoon;Yoon, Jongho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.199.1-199.1
    • /
    • 2010
  • The purpose of this study is on the thermal performance evaluation of KIER Zero Energy Solar House-II, called ZeSH-II which can be sustained with the support of a very few energy. This ZeSH-II was designed and constructed in the end of 2009 to develop for the goal of 70% self-sufficiency. Several key technologies like as the super insulation, high performance window, wast heat recovery system as well as solar power and thermal system and geo-source heat pump wear used for this ZeSH-II. The monitering of ZeSH-II was conducted for six months from November 2009 to April 2010. The monthly energy consumption was calculated based on the monitering results. As a result, the ZeSH-II shows that the energy self-sufficiency during six months(from oct. to apr.) is about 80% which is higher than that of the target.

  • PDF

Development of Complex USN Sensor for Zero Energy House with Blind System (블라인더가 설치된 제로에너지 하우스를 위한 복합 USN 센서 개발)

  • Kim, Kee-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.221-227
    • /
    • 2013
  • In this paper, zero-energy house in order to monitor the energy savings come with Zigbee communication temperature humidity, smoke detection, illumination and CO2 to develop complex sensor board a protocol for handling about it dealt. In particular, indoor space to mount the sensor based on the location of the control algorithm, so it varies through the Zigbee wireless sensor mounting position is free, and the advantage of being able to change. Also, the energy loss that occurs through the window can be reduced to the room lighting can play an important role in the control system.

Study on the Recognition Analysis of Zero Energy House and Associated Policy Suggestion (에너지제로하우스 인식분석 및 정책 추진방향 제안에 관한 연구)

  • Lee, Chung-Kook;Lee, Jeong-Cheol;Kim, Sang-Su;Suh, Seung-Jik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.16-26
    • /
    • 2012
  • The consultation with building energy experts working at domestic government-funded research institutes and enterprises on performance set, element technology, and policy for the realization of low-energy and the survey with construction workers on the relevance of climate change in building construction, government support policy, and methodologies for the construction of low-energy house were carried in the study. In addition the public element preference survey on the low-energy house and awareness research on the low-carbonization of building were carried and presented for the development of affordable low-energy house. There was a big difference in the recognition of building energy performance setting and setting for the construction cost to realize it between experts and ordinary citizens in the study. To fill this gap education and promotion of zero energy house and securing economic feasibility through the commercialization of element technology will be needed. The satisfaction in government's zero energy house policy was normally low. To improve this low satisfaction administrative and technical support are considered to be expanded. Common high cost of construction was the top priority to resolve the problem, and enhancing renewable energy grants, tax relief, and substantial cost support could be as detailed solutions.

Active Solar Heating System Design and Analysis for the Zero Energy Solar House (제로에너지 솔라하우스의 난방/급탕용 태양열 시스템 설계 및 분석)

  • Baek, N.C.;Yoo, C.K.;Yoon, E.S.;Yoo, J.Y.;Yoon, J.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • This study is on the design and evaluation of Zero Energy Solar House(ZeSH) including active solar heating system. Various innovative technologies such as super insulation, passive solar systems, super window, ventilation heat recovery system...etc were analyzed by individual and combination for the success of ZeSH. The ESP-r simulation program was used for this. Simulation results shows that almost 77% of heating load can be reduced with the following configuration of 200mm super insulation, super windows, passive solar system and 0.3 ventilation rate per hour. Active solar heating system (ASHS) was designed for the rest of the heating load including hot water heating load. The solar assisted heat pump is used for the auxiliary heating device in order to use air conditioner but not included in this study. The yearly solar fraction is 87% with a solar collector area of $28m^2$. The parametric studies as the influence of storage volume and collector area on the solar fraction was analyzed.

A Study on the Optimization of Photovoltaic System for the ZEB Certification in Detached Housing (단독 주택의 제로에너지건축물 인증을 위한 태양광시스템 최적화에 관한 연구)

  • Shin, Jee-Woong;Yun, Jae-Hyun;Ko, Jeong-Lim
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • As part of the government's energy policy, Zero Energy Building certification was launched on January of 2017. However, the three passive-housing rental housing projects are the only ZEB-certified detached housing since the certification's launch. The reason is that, in order for a detached housing to earn ZEB certification, it has to secure self-reliance in energy, and a photovoltaic system is the only viable renewable energy system. Therefore, conducting an analysis to optimize the photovoltaic system in an early design stage is strongly recommended. This study aimed to propose an optimal photovoltaic system design for a detached housing after analyzing through the ECO2 energy simulation of 44 cases, varying in a module type and efficiency, inclination and azimuth. As a result, 15 cases out of 44 cases were analyzed to satisfy ZEB evaluation criteria, and it is thought that these data could contribute greatly to the expansion of ZEB certification dissemination.