자기공명 영상장치에서 정형보철금속의 자화(磁化)에 관한 연구 (A Study on the magnetization of metal orthopedic prosthesis in magnetic resonance imaging)

  • 김형균;송득중;최성대
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.34-39
    • /
    • 2013
  • For orthopedic artificial metal stainless steel, the magnetization of the magnetic field due to the presence of the titanium was to observe the change. Magnetic field meter (Tesla meters) a certain distance (ISO Centre) 1.5 Tesla magnetic field, the magnetization in the center with the passage of time were measured. Therefore, these artificial metal clip shape and magnetization of the sample size to produce a ferromagnetic material for comparison is the experimental dependence. For comparison of the experimental dependence of the magnetization, thereby producing a test piece size such as shaping prosthetic metal Clip is a ferromagnetic material. The experimental results, the metal orthopedic implants, there was no change in the magnetization indicated by ferromagnetic material in its natural state. However, in a magnetic field of 1.5T (Tesla), showed a sensitivity that is magnetized rapidly compared to the ferromagnetic material. In conclusion, high in the order of Clip, Stainless, of Titanium, the degree of dependence of the magnetization intensity of magnetization was the order Stainless, Titanium, of Clip in a magnetic field.

정형보철용 금속을 이용한 자기공명영상왜곡의 정량적 평가 (Quantitative evaluation of MRI distortion using orthopedic prosthetic metal)

  • 김형균
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.57-62
    • /
    • 2013
  • 자기공명영상은 많은 장점에도 불구하고 체내에 정형보철이 있는 경우 자화율 차이로 영상왜곡이 발생한다. 스테인리스와 티타늄 시험편을 $65{\times}15{\times}2mm$로 동일하게 제작하여 phantom과 돼지고기에 부착 한 후 자기공명영상과의 관계를 알아보았다. phantom 영상을 통해 영상왜곡의 길이와 돼지 뼈를 통한 신호강도의 변화, 피하조직의 지방억제 정도를 정량적으로 평가 하였다. 스테인리스는 티타늄에 비해 길이 방향으로 4.4배, 높이 방향으로 2.8배 영상왜곡이 크며, 신호강도는 58.5%로 상대적으로 낮았다. 피하조직 지방억제는 Normal의 56.2%에 비해 스테인리스는 16.04%, 티타늄은 54.53%로 나타났다. 실험 결과 자기공명영상의 영상학적 진단가치는 스테인리스 보다 티타늄 금속이 부착 된 경우 더 우수한 것을 알 수 있었다.

정형 보철용 금속이 자기공명영상에 미치는 영향 II (Effect of Metals used in Orthopedic on Magnetic Resonance Imaging II)

  • 김형균;최성대
    • 한국기계가공학회지
    • /
    • 제11권5호
    • /
    • pp.115-120
    • /
    • 2012
  • Metals used orthopedic in human magnetic resonance imaging scan of the metal to be inserted, The information to users about the image distortion is to propose a basis for judgment. Metals used orthopedic on Stainless, Titanium and Clip using ferromagnetic artifacts and distortion of the image were measured. Using Phantom "Effect of Metals used in Orthopedic on Magnetic Resonance ImagingI" pig in a paper subsequently was carried out using the same bone. Experimental results using a pure Titanium is a relatively high diagnostic value was found that.

정형보철용 금속이 자기공명영상에 미치는 영향 I (Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I)

  • 김형균;최성대
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.46-50
    • /
    • 2012
  • Stainless steel and titanium used for orthopedic prosthetic metal, magnetic resonance imaging was measured quantitatively the extent of distortion. Based on reading tests at varying metal magnetic resonance imaging (MRI) were investigated. To two image acquisition conditions for having three metal bodies mutually quantitative it compared analyzed the image of cross direction and the image of lengthwise. As for the distortion of the magnetic resonance image, as for the distortion of image it became small in the order of Clip, Strainless and Titanium. In addition, with T1WI and T2WI which are image acquisition condition T2WI the distortion of image became small. As for the distortion of the image by the metal, you could see the distortion of image in elliptical shape, the metal a bigger image distortion appeared in many parts. If clinical doctor has the condition of the same operation, use the Titanium material, it can, raising the diagnostic value of magnetic resonance image inspection after the operating from Stainless.

자기공명영상에서 정형보철 금속이 신호강도와 영상왜곡에 미치는 영향 (The Impact of Signal Intensity and Image Distortion Magnetic Resonance Imaging in the Orthopedic Prosthetic Metal)

  • 김형균;최성대
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.321-326
    • /
    • 2012
  • 병원에서 정형보철용 재료로 사용하는 스테인리스와 티타늄 금속을 같은 크기로 제작하여 자기공명영상에 미치는 영상학적 진단가치를 비교하였다. 영상의중심(Center), 영상이외부분(Background), 고 신호부분(High band)에 대한 신호강도 값을 가중치로 변환하여 금속시험편 없는(Norma)영상과 비교하였다. 또한 시상면영상과 횡단면영상의 왜곡범위를 정량적으로 수치화하여 금속시험편 없는 영상면적과 비교하였다. 그 결과 고 신호영상의 신호강도 값은 스테인리스의 경우 팬텀(Phantom) 2, 돼지 뼈(Bone) 1.8, 티타늄의 경우 팬텀 1.7, 돼지 뼈 1.3 만큼 금속시험편 없는 신호강도가중치 값보다 높은 것을 알 수 있었다. 또한 자기공명영상의 왜곡형태와 왜곡 범위는 금속시험편이 없는 영상의 단면적대비 스테인리스의 경우 팬텀 65.8 %, 돼지 뼈 61.5 %, 티타늄은 팬텀 23.1 %, 돼지 뼈 38.5 % 의 왜곡범위를 나타냈다. 결론적으로 본 실험에서는 신호강도가중치값과 왜곡범위가 낮게 변화를 보인 티타늄이 스테인리스 시험편보다 더 진단적 가치가 높은 자기공명영상임을 알 수 있었다.

VAT-SEMAC을 이용한 보철물에 의한 허상 감소 (Reduction of Metal Artifact by Using VAT-SEMAC in MRI)

  • 김형태;임종남;천권수
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.227-232
    • /
    • 2019
  • 자기공명영상에서 금속 물질이 삽입된 환자에서 자기감수성에 의한 허상이 발생하여 영상의 진단적 가치가 저하되는 문제가 발생하고 있다. 여러 가지 인공물 감소기법 중 VAT-SEMAC 기법을 적용하여 영상의 왜곡에 대해 연구 하였다. 정형외과 수술시 사용되는 금속 임플란트를 팬텀에 부착하여 T1WI, T2WI를 스캔 시 허상으로 인한 왜곡을 측정하였다. 감소기법의 미적용, VAT 적용, VAT-SEMAC을 호환 적용하여 검사를 실시한 후 허상을 비교 분석 하였다. 허상은 VAT-SEMAC에서 최소 8%에서 최대 26%의 감소를 보였다. VAT-SEMAC 기법을 적용하면 정형 보철물이 삽입된 환자에게도 영상의 질을 향상시켜 진단적 가치가 향상된 영상을 획득할 수 있다. 적절한 스캔시간과 영상의 질을 동시에 고려한다면 실제 임상에서 VAT-SEMAC의 적용하여 허상 감소효과를 얻을 수 있을 것이다.

정형 보철용 금속이 자기공명영상에 미치는 영향 III (Effect of Metals used in Orthopedic on Magnetic Resonance Imaging III)

  • 김형균;최성대
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.42-47
    • /
    • 2012
  • Followed by a paper on the Pig and Bone orthopedic prosthetic, this experiment using Phantom and Bone MRI imaging I, II of orthopedic prosthetic metal effect combines magnetic resonance imaging on metal signal-to-noise ratio(Signal to noise : SNR) and CNR(Contrast to noise: CNR), fat signal suppression(Fat-suppression) images was compared. Specimen trees to measure the reliability of the experimental reproducibility tests and statistical analysis using the SPSS statistical package was applied program SPSS(IBM SPSS Statistice 19) by * P = 0.000 < significance level $({\alpha})$ = 0.01 as a significant there was a correlation(** P < 0.01). SNR and CNR results did not directly proportional to the Titanium, Stainless, Clip CNR and fat signal suppression of the order of images of blood specimens was found to be close to the image. The impact of orthopedic prosthetic metals on magnetic resonance imaging in the diagnostic value of Titanium is relatively high and are meant more.