Intercomparison Tests of National Standard Measuring System for Switching Impulse Voltage rated 500 kV (500 kV 개폐충격전압시스템의 비교시험)

  • Kim, I.S.;Kim, M.K.;Jeong, J.Y.;Moon, I.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.261-263
    • /
    • 2003
  • This paper represents the development of national standard(NS) for switching impulse(SI) voltage measuring system rated 500 kV. A traceability of the NS to the international standard could be achieved by the intercomparison test with CSIRO of Australia. According to the IEC 60060-2, a measurement uncertainty was assessed. As a result of the tests, a measurement uncertainty and step response characteristics were satisfied with the requisite for NS.

  • PDF

Fabrication of Copper Electrode Array and Test of Electrochemical Discharge Machining for Glass Drilling (유리의 미세 구멍 가공을 위한 구리 전극군 제작 및 전기 화학 방전 가공 시험)

  • Jung, Ju-Myoung;Sim, Woo-Young;Jeong, Ok-Chan;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.297-299
    • /
    • 2003
  • In this paper, we present the fabrication of copper electrode array and test of electrochemical discharge machining for the fabrication of microholes on Borofloat33 glass. Copper electrode array is fabricated by the bonding of silicon upper substrate and lower substrate and copper electroplate. The silicon upper electrode having microholes fabricated by ICP-RIE is the mold of copper electroplate. The lower substrate is used as the seed layer for copper electroplate after Au - Au thermocompression bonding with the upper substrate.

  • PDF

Insulation Gas to characterize the rise-time of an Utra-fast Marx generator (절연 가스에 따른 초고속 Marx generator의 상승 시간 특성)

  • Doo, Jin-Suk;Bang, Jung-Ju;Kim, Kwang-Yong;Hwang, Sun-Mook;Seo, Yu-Jin;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1396_1397
    • /
    • 2009
  • Recently, there has been considerable interest in electromagnetic pulse (EMP) source for no lethal directed energy weaponry applications. The compactness of the Marx generator, coupled with its ability to be powered by battery technology, makes it a viable handled impulse source. The marx generator has 2 stages. Each stage was constructed one charging capacitor, two electrodes and one charging resistor. A inductance structure is used in order to improve the switching performances fo the whole generator. The experiments of rise time in pure gas and mixtures of gases were described. The experimental results show that the rise time characteristics of the marx generator can be controlled through varying insulation gas.

  • PDF

An Architectural Study on the Healing Environment Design through the Analysis of Sensory Stimulation in the General Hospitals' Patient-Room (감각자극 분석을 통한 종합병원 다인 병실의 치유 환경에 관한 건축 계획적 연구)

  • Chung, Joo-Hyun;Yang, Nae-Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.2
    • /
    • pp.7-15
    • /
    • 2006
  • Patients use the senses all the time, mostly simultaneously. Senses are never turned off even patients in serious condition use some of the senses. Space is the inexhaustible source of stimuli. So far we have thought that it is impossible to come up with a set of rules and guidelines that cover all the possible situations involving senses and when there have been usually no conscious coordination between different sensorial stimuli and the comprehensive perception of space always results from the engagement of combination of senses and other inputs based on knowledge and experience. This study concerns about patients' demand analysis through senses. The reflection of patients' demand to the ward planning can develope the healing environment.

  • PDF

The Current and Power Waveform Improvement of an AC Motor with Low Pass LC Filter Driven by a Digital Bridge Inverter(I) (디지탈 브리지형 인버터로 구동되는 저역통과 LC 필터를 가진 교류전동기의 전류 및 전력의 파형 개선 (I))

  • 정주윤;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.107-118
    • /
    • 1995
  • The characteristics of the current waveforms and 3$\Phi$ power waveforms of the variable speed 3$\Phi$ AC motor system driven by the single-pulse PWM investigated in this paper. The system is composed of a digital bridge inverter and low pass LC filter. It is confirmed that current waveforms and 3$\Phi$ power waveforms can be improved by utilizing the high order low pass LC filter than that of lower order through computer simulation. Also, we propose the low pass LC filter revised from the conventional LC filter.

  • PDF

Microcomputer-Based Constant Frequency Control of Generating System Driven by Hydraulic Power -Pump Displacement Control Type - (마이크로컴퓨터에 의한 유압구동식 발전장치의 정주파수 제어)

  • 정용길;이일영;김상봉;양주호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.53-63
    • /
    • 1991
  • This study suggests a new type shaft generator driven by hydraulic power suitable for small size vessels. Since the shaft generator system is very easy to be affected by disturbances such as speed variation of main engine and load variation of the generator, a robust servo control must be implemented to obtain stable electric power with constant frequency. Thus, in this study two types of controller design method-the reference following optimal control method and robust servo control method-are adopted to the controller design. In the experiment, static and dynamic characteristics of the shaft generator system according to the variation of input frequency setting, the speed variation of the pump and the load variation of the generator are investigated. From the considerations on the computer simulation results and experimental results, it is ascertained that the shaft generator system proposed in this study has good control performances.

  • PDF

Development of Heat Control Valve Using SMA and Remote Controller for House Heating System (형상기억합금을 이용한 난방용 온도조절 밸브 및 원격 제어장치 개발)

  • Choi, Jeongju;Yeom, Jeongkuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.6-11
    • /
    • 2010
  • For the purpose of reducing the energy consumption in the house heating, the various devices have been developed. One of these is to control the flow in the heat pipe and the flow control valve using shape memory alloy(SMA) spring is proposed in our study. The proposed house heating system is to save the gas consumption and the remote control system is designed for the convenience of using the proposed valve. The developed valve consists of SMA spring, disk, return spring, and regulation handle. The regulation handle is for supplying the additional hot water and is controlled by remote-control-motor. In order to design the remote control system, the Zigbee wireless communication protocol is used. The performance of the proposed valve structure is shown through the experimental result.

Surgical Management of Petus Excavatum with Using Pectus Bar (Pectus Bar를 이용한 누두흉에서 수술적 치료)

  • 황정주;신화균;김도형;이두연
    • Journal of Chest Surgery
    • /
    • v.34 no.2
    • /
    • pp.167-172
    • /
    • 2001
  • 배경: 누두흉은 앞가슴 기형 중 가장 흔하며 Meyer 등이 1911년 수술적 교정을 시행한 이래로 많은 술식들이 개발되어 왔다. 이들의 대부분은 전흉벽에 상처를 내고 늑연골을 자르는 과정이 필요하였다. 그러나 Nuss 등에 의해서 상기 과정없이 작은 옆가슴의 상처와 stainless steel bar로 흉골의 기형을 교정하는 국소침습적 방법이 개발되었다. 대상 및 방법: 1999년 11월부터 2000년 7월까지 누두흉의 교정을 원하는 환자 14예를 대상으로 하였다. 수술은 15세미만에서는 pectus bar를 1개를 사용하였고 그 이상에서는 2개를 사용하여 교정하였다. 결과: 남자는 11예, 여자는 3예 였으며 나이는 2세에서 52세 사이였다. 누두흉 지표는 5.3$\pm$1.84였고 비대칭지표는 1.06$\pm$0.03이였다. 수술 후 2일째 모두 일반병실로 올라갔다. 평균 재원기간은 4.2일이였다. 술후 합병증으로 성인에서 기흉 1예, 혈흉 1예, 그리고 나중에 발생한 흉막액 1예가 있었다. 결론: 누두흉에서 Nuss 술식으로 좋은 결과를 얻었다. 성인에서도 bar 2개를 이용하여 교정이 가능하였으나 소아에 비하여 합병증이 많이 발생하였는데 이는 성인에서 근육이 발달되어 있고, 뼈의 골화가 다 진행되었기 때문이다.

  • PDF

A Case of Intractable Hiccups Associated with High Dose Intravenous Methylprednisolone in a Patient with Third Nerve Palsy (동안신경마비 환자에서 고용량 메칠프레드니솔론 정주 후 발생한 난치성 딸꾹질 1예)

  • Na, Sang-Jun;Yum, Kyu Sun;Lee, Kee Ook
    • Annals of Clinical Neurophysiology
    • /
    • v.10 no.1
    • /
    • pp.79-82
    • /
    • 2008
  • The etiology of intractable hiccups is most commonly idiopathic. However, they are occasionally associated with some underlying disorders including gastro-esophageal reflux disease. There are a few previous reports describing the association of intractable hiccups with high dose corticosteroid. We experienced an unusual case of intractable hiccups following a high dose intravenous methylprednisolone therapy in a patient with right third nerve palsy. Since methylprednisolone is commonly used in various neurological problems, physicians should be aware of its possible side effect including intractable hiccups.

  • PDF